• 제목/요약/키워드: NIOSH

검색결과 271건 처리시간 0.022초

컴프레서 제조공정의 인간공학적 개선에 관한 연구 (Ergonomic Evaluation and Improvement of the Manufacturing Lines of Compressors)

  • 배동철;장성록
    • 한국안전학회지
    • /
    • 제20권1호
    • /
    • pp.148-152
    • /
    • 2005
  • The purpose of this paper is to investigate risk factors and ergonomically improve the manufacturing lines of compressors for prevention of work-related musculoskeletal disorders, enhancement of productivity, and workers satisfaction We executed questionnaire survey, ergonomic risk factors investigation of manufacturing lines and ergonomic intervention of work methods, workplace and hand tools. The results of the questionnaire showed that $7.9\%$ of respondents were positive in WMSDs symptom survey. In ergonomic evaluation, the analysis methods such as RULA and NIOSH lifting equation were used and 28 processes in the lines were evaluated to be potentially hazardous. We ergonomically improved the processes to reduce potential WMSDs hazards : manual material handling, carts, work tables, transport methods, working posture and hand tools.

병원 환자 운반 업무의 작업 부하 분석 및 개선 방안 (Workload of Patients Transferring and its Improving Methods)

  • 기도형
    • 한국안전학회지
    • /
    • 제21권2호
    • /
    • pp.121-127
    • /
    • 2006
  • Nursing often requires heavy physical work activities such as lifting heavy loads, working in awkward postures, transferring patients, operating hazardous equipment, etc. Among various nursing tasks, patients transferring is one of the most physically demanding tasks. This study aims to investigate workload of the patients transferring, and to propose its improving methods for reducing high workload. The results showed that irrespective of methods for patients transferring and the number of workers involved, workload for most patients transferring tasks exceeded the action limit represented in terms of L5/SI compressive force of 3,400N or LI of 1.0 by NIOSH. The loads for some tasks were far larger than the maximum permissible limit of 6,400N. It is recommended that the mechanical devices for transferring patients such as ceiling crane, sling lift etc. should be introduced rather than simply increasing the number of workers in the tasks.

대한산업보건협회 산업보건연구소의 미국 정도관리 참여결과

  • 이선주;최호춘;박찬우;오미순;이준승;전수경;박화미;정규철
    • 월간산업보건
    • /
    • 통권88호
    • /
    • pp.57-60
    • /
    • 1995
  • PAT program(The Proficiency Analytical Testing Program)은 미국산업위생협회(American Industrial Hygiene Association AIHA)와 미국산업안전보건연구원(National Institute for Occupational Safety and Health NIOSH)에서 공동주관하는 정도관리로서 일년에 4회 실시하고 있다. 실시항목은 금속(납, 카드뮴, 크롬, 아연), 유리규산, 석면, 유기,용제(Benzen, O-Xylene, Toluene, Carbon Tetrachloride, 1, 1, 1-Trichloroethane, Chloroform, Tetrachloroethylene, 1, 2-Dichloroethane, methanol, p-Dioxane)이다. 대한산업보건협회 산업보건연구소에서는 위의 4가지 항목을 모두 신청하여 1995년 1월에 실시된 120회 부터 참여하였는데 다음은 본 연구소의 120화에 대한 분석방법과 NIOSH로 부터 받은 결과이다.

  • PDF

NIOSH Guideline의 국내 산업 적용 적합성에 관한 연구

  • 이관석;전영호;박희석;김윤철
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1994년도 춘계학술대회논문집
    • /
    • pp.105-105
    • /
    • 1994
  • 신체 부위를 이용한 Manual Materials handling(MMH) 작업시 무리한 작업하중의 취급으로 인하 여 많은 사고 또는 요통이 발생하기 때문에 작업자의 능력에 맞는 적정 하중에 대한 연구가 필요 하다. MMH작업의 적정하중에관한 연구는 미국 등의 나라에서는 많이 이루어져 왔으나 우리나라에서 는 연구되어 있지 않다. 미국의 경우 NIOSH Guideline을 만들어 MMH시 작업지침으로 활용하고 있으 나 이 지침을 그대로 우리나라에 적용하기에는 신체조건이 달라 우리나라 고유의 연구가 필요하겠다. 적정하중의 연구에는 많은 시간과 경비가 필요하기 때문에 외국의 경우 심리 육체적방법(Psychophysical Method)을 사용하여 시간과 경비를 줄이고도 실제 8시간 작업시의 결과와 비슷한 결과를 얻었다. 본 연구에서는 MMH작업의 적정 하중결정에 있어서 심리육체적 방법을 사용하여 한국인 작업자에 대한 하중과 HIOSH Guideline의 RWL값과의 비교를 하였다. 학생군과 실제 작업자군의 피실험자에 대하여 심리육체적 방법을 적용하여 들기작업을 실험하였다. 6가지 들기 작업을 20분 동안 실시하여 피실험자들이 자신에게 적합하다고 생각하는 적정하중을 측정하였다. 그 결과, 학생군은 RWL값보다 평균 2.5배를, 작업자군은 3.4 배를 적정하중으로 정하였다. 따라서 HIOSH Guideline을 적용한 RWL값은 우리나라 작업자에게는 많은 여유가 있는 하중임을 보여 주었다.

  • PDF

초음파 전처리에 의한 용접 흄 중 6가 크롬의 분석 (Sonication in the Analysis of Hexavalent Chromium in Welding Fume)

  • 윤충식;백남원;김정한;박동욱;최상준;김신범;채현병
    • 분석과학
    • /
    • 제12권5호
    • /
    • pp.447-459
    • /
    • 1999
  • 용접 흄에 존재하는 6가 크롬의 분석방법을 평가하기 위하여 깨끗한 PVC여과지와 용접 흄 매트릭스의 여과지에 일정량의 6가 크롬과 3가 크롬을 첨가한 후 NIOSH 7600 및 7604의 알카리 추출방법, 마그네슘 첨가방법, 아세트산 나트륨 완충액 추출로 전처리를 하여 분광광도계(DPC), 유도결합플라스마-광학발광분석법(ICP-OES), 이온크로마토그래피(IC)로 분석하였다. 위 전처리 방법은 모두 부적절하여 새로운 방법으로 알카리 용액상에서 초음파 추출하는 방법을 제안하였다. NIOSH에서 추천하는 2% NaOH/3% $Na_2CO_3$ 추출방법은 6가 크롬만 있을 때 적합하고 3가 크롬이 있으면 일부가 6가 크롬으로 산화된다. 산화 경향은 용접 흄이 있을 때 크게 나타났다. 분광광도계를 이용한 diphenylcarbazide방법은 저농도와 고농도의 6가 크롬이 있을 때 부적합하고 알카리 추출을 하면 ICP-OES분석방법이나 IC분석방법이 적합하다. 용접 흄 중 6가 크롬을 전처리하는 방법으로 NIOSH 방법의 $135^{\circ}C$로 가열하는 대신 초음파처리를 하면 3가의 6가로의 산화를 훨씬 억제할 수 있다. 즉, 2% NaOH/3% $Na_2CO_3$로 초음파처리를 60분 이내에 실시하여 IC 또는 ICP-OES(또는 AAS)로 측정하면 된다.

  • PDF

호텔업종사자의 근골격계부담작업 특성과 근골격계유병률 (Job Characteristic and Musculoskeletal Symptom Prevalence in Hotel Employee)

  • 김지은;문덕환
    • 한국직업건강간호학회지
    • /
    • 제19권2호
    • /
    • pp.190-204
    • /
    • 2010
  • Purpose: This study was conducted to obtain the fundamental data on prevention and management of musculoskeletal symptoms, and to assess the prevalence, risk factors and job characteristics of musculoskeletal symptoms in hotel employees. Methods: The work sampling analysis was carried out by OWAS, and the prevalence was surveyed in term of NIOSH diagnostic criteria and work related risk factors on 263 hotel employees in Busan, Korea, using structured self-administered questionnaire from Jan. 20 to Feb. 26, 2010. The collected data were analysed by the SPSS 18.0. Results: 1) The prevailing rate of musculoskeletal symptoms by NIOSH diagnostic criteria was 43.80% for total subjects and 27.91% for shoulders, 12.79% for neck, and 11.24% for back/waist, respectively. 2) Factors affecting the prevalence of musculoskeletal symptoms were examined and multivariate logistic regression analysis was performed. As a result, women, having a burden of musculoskeletal work, increased work time in case of a higher risk of the prevalence of musculoskeletal symptoms (P<0.1). 3) The body parts and the department with the prevalence of musculoskeletal symptoms showed a significant difference (P<0.05) compared with symptoms on shoulders, arms/elbows, and ankles/feet. Conclusion: The prevalence of musculoskeletal symptoms by NIOSH diagnostic criteria in hotel employees was relatively high showing 43.80% for total subjects and higher in departments of laundry, reservations, cooking, food&beverage, dishwashing, and room cleaning than others.

작업환경 중 MWF 미스트와 증기에 대한 측정방법의 개발 - PVC 필터에 채취된 비수용성 MWF손실에 대한 보정 - (The Recommendation of Sampling Method for Airborne MWF in Workplace - Correction for MWF Lost on PVC Filter -)

  • 박동욱;김신범;신철임
    • 한국산업보건학회지
    • /
    • 제8권2호
    • /
    • pp.186-195
    • /
    • 1998
  • The objective of this study was to determine if MWF(metalworking fluids) mass sampled on PVC filter lose during flowing airstream and desiccating and to present direction to correct the underestimated MWF mass. Flowing airstream caused MWF sampled on PVC filter to be breakthrough and lost. Loss of MWF on PVC filter increased in proportion to time of flowing airstream. Meanwhile, loss of MWF was observed during desiccating without flowing airstream. Vapor pressure of MWF is so low that it would not normally be thought to evaporate. However, MWF mist sampled on PVC filter has so great a surface area that loss by flowing airstream and evaporation can be appreciable. Loss between fresh and used MWF was also different. Those study results mean that NIOSH method(#0500 method) to take airborne MWF mist with PVC filter is not valid. Media to sample airborne MWF accurately still have not been introduced. It seems to be needed to estimate how much MWF on PVC filter may be lost during sampling. Regression model between sampling time including 1 day desiccating and total loss of MWF was "Total loss(%)=18.4%+0.06 sampling time(p=0.000, r2=49.6%)". This model help correct MWF lost when one measures airborne MWF using NIOSH # 0500 method.

  • PDF

한국 작업자의 요통예방을 위한 작업하중 설계지침

  • 이관석;박희석;서치원
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1995년도 춘계학술대회논문집
    • /
    • pp.97-105
    • /
    • 1995
  • 본 연구의 목적은 드는 작업에 있어서 한국 작업자의 적정하중을 구하여 중량물 안전기준을 정하는 것이다. 본 연구에서는 주어진 작업조건하에서 피실험자가 들어올릴 수 있는 적정하중을 결정하기 위 한 기준으로서 피실험자 자신에 의해서 인지되는 스트레스 정도를 이용하는 심리육체적 방법(Psychophysical method), 주어진 작업조건하에서 요추에 가해지는 압력을 이용하는 생체역학적 방법(Biomechanical method), 주어진 작업조건하에서 피실험자의 에너지 소모량을 이용하는 생리학적 접근법등이 이용되었다. 피실험자는 학생(n=3) 두개의 군으로 나뉘어진다. 실험에 들어가기 전에 피실험자에 대한 인체측정과 근력측정을 수행 하였다. 실험은 수직면에서 드는 빈도(1,2, 와 4회/분)와 드는 높이(0-8cm 와 47-102cm)를 조합한 6가지의 작업을 무작위로 선택하여 심리육체적 방법으로 각 작업에 대한 적정하중을 구하였다. 연구결과로서 피실험 자의 신체자료와 근력의 비교로부터 신체조건은 학생이 우수하였으나, 근력은 작업자가 우수하였다. 본 연구 에서 채택된 들기의 빈도가 변함에 따라 최대허용 하중은 변하였다. 작업자군에 대하여는 빈도가 증가할수록 최대허용 하중은 감소하였으며, 학생군에 대하여는 분당 1회와 분당 4회간의 유의한 차이가 있었다. 들기의 시작-종점의 변화에따른 최대허용 하중은 통계적으로 유의하지 않았다. 위의 두 결과는 들기의 빈도가 들기의 시작-종점보다 민감한 변수임을 가리키며 이는 미국 NIOSH의 결과와 일치한다. 심리육체적 방법을 사용하여 우리나라의 젊고 건강한 남성의 대부분(99%)을 고려하여 산출된 최대허용 하중은 미국 NIOSH 안전기준과 큰 차 이가 없음을 발견하였다. 또한 이 최대허용 하중은 인체역학적방법과 생리학적 방법을 사용하여 검토한 결과, 무리가 없는 수준임이 입증되었다. 본 연구의 결과를 토대로우리나라 젊고 건강한 남성에게 적합한 무게상수는 작업자군에 대하여 25.05kg, 학생군에 대하여 20.24kg 으로 나타나 이는 미국 NIOSH 안전기준과 대체로 일치함을 발견하였다.

  • PDF

공기중 6가 크롬 측정 방법 비교 -검출한계, 정확도 및 정밀도- (Comparison of Sampling and Analytical Methods for Determining Airborne Hexavalent Chromium -Limit of Detection, Accuracy and Precision of Analytical Procedures)

  • 신용철;이병규;이지태
    • 한국대기환경학회지
    • /
    • 제18권1호
    • /
    • pp.39-49
    • /
    • 2002
  • In this study, limits of detection (LOD), accuracy and precision of four sampling/ analytical methods were evaluated and compared for the determination of airborne hexavalent chromium, Cr (VI). The methods include : (1) a combination of the National Institute for Occupational Safety and Health (NIOSH) Method 7600/U. S. Environmental Protection Agency (EPA) Method 218.6 (NIOSH/EPA Method) proposed by Shin and Paik, 2) two impinger methods using 2% NaOH/3% Na$_2$CO$_3$. (3) same as (2) but with 0.02 N NaHCO$_3$absorbing solution, and (4) the Occupational Safety and Health (OSHA) Method ID-215. An ion chromatograph/visible absorbance detector was used for the analysis of Cr (VI) in sample solution. Limit of detection (LOD) , analytical accuracy, and precision were also tested using Cr (VI) spike samples. Recoveries (as index of accuracy) and coefficient of variation (CV) (as a index of precision) were determined. Two-way ANOVA and Turkey's test were performed to test the significance in differences among recoveries and CVs of the methods. In all the methods, the peaks of Cr (VI) were separated sharply on chromatograms and exhibited a strong linearity with Cr (VI) concentrations in solution. The correlation coefficients of calibration curves typically ranged from 0.9997 to 0.9999, and the analytical LODs from 0.025 to 0.1$\mu\textrm{g}$/sample. All the method had good sensitivities and linearities between Cr (VI) levels and peak areas. The accuracies (% mean recoveries) of the methods ranged from 80.1 to 104.2%, while the precisions (pooled coefficient of variation) ranged from 3.16 to 4.43%. The impinger methods showed higher recoveries ( > 95%) than those of the PVC filter methods (the OSHA Method and the NIOSH/EPA Method). It was assumed that Cr (VI) on PVC filter was exposed to air and reduced to trivalent chromium, Cr (III), whereas it was stabilized in alkali solution contained in impinger. Thus, a special treatment of Cr (VI) samples collected on PVC filters may be required.