• Title/Summary/Keyword: NExT

Search Result 71, Processing Time 0.02 seconds

Inductor-less 6~18 GHz 7-Bit 28 dB Variable Attenuator Using 0.18 μm CMOS Technology (0.18 μm CMOS 기반 인덕터를 사용하지 않는 6~18 GHz 7-Bit 28 dB 가변 신호 감쇠기)

  • Na, Yun-Sik;Lee, Sanghoon;Kim, Jaeduk;Lee, Wangyoung;Lee, Changhoon;Lee, Sungho;Seo, Munkyo;Lee, Sung Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.1
    • /
    • pp.60-68
    • /
    • 2016
  • This paper presents a 6~18 GHz 7-bit digital-controlled attenuator. The proposed attenuator is based on switched-T architecture, but no inductor is used for minimum chip size. The designed attenuator was fabricated using $0.18{\mu}m$ CMOS process, and characterized using on-wafer testing setup. The resolution(minimum attenuation step) and the maximum attenuation range of the attenuator were measured to be 0.22 dB and 28 dB, respectively. The measured RMS attenuation error and the RMS phase error for 6~18 GHz were less than 0.26 dB and $3.2^{\circ}$, respectively. The reference state insertion loss was less than 12.4 dB at 6~18 GHz. The measured input and output return losses were better than 9.4 dB over all frequencies and attenuation states. The chip size is $0.11mm^2$ excluding pads.

Operational modal analysis for Canton Tower

  • Niu, Yan;Kraemer, Peter;Fritzen, Claus-Peter
    • Smart Structures and Systems
    • /
    • v.10 no.4_5
    • /
    • pp.393-410
    • /
    • 2012
  • The 610 m high Canton Tower (formerly named Guangzhou New Television Tower) is currently considered as a benchmark problem for structural health monitoring (SHM) of high-rise slender structures. In the benchmark study task I, a set of 24-hour ambient vibration measurement data has been available for the output-only system identification study. In this paper, the vector autoregressive models (ARV) method is adopted in the operational modal analysis (OMA) for this TV tower. The identified natural frequencies, damping ratios and mode shapes are presented and compared with the available results from some other research groups which used different methods, e.g., the data-driven stochastic subspace identification (SSI-DATA) method, the enhanced frequency domain decomposition (EFDD) algorithm, and an improved modal identification method based on NExT-ERA technique. Furthermore, the environmental effects on the estimated modal parameters are also discussed.

악성뇌종양 주변부위의 역동자기공명영상의 시간신호강도곡선 양상과 예후와의 관계

  • 최순섭;김기욱;허기영;이영일
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.21-21
    • /
    • 2003
  • 목적: 악성뇌종양 주변부위의 역동자기공명영상에서의 시간신호강도곡선 양상으로 종양의 성장 양상이나 예후를 판단할 수 있는지를 알고자 한다. 대상 및 방법: Anaplastic oligodendroglioma 3예, Anaplastic astrocytoma 1예, Glioblastoma multiforme 1예, Malignant ependymoma 2예, Medulloblastorna 1예로서, 총 8예의 종양절제전, 혹은 후의 잔류 종양을 대상으로 하였다. Routine MRI에 추가하여 종양부위에서 Turbo spin echo T1 강조 역동자기공명영상을 하였으며, Gd-DTPA 0.1 mmol/kg를 급속 주사 한 후, TR/TE, 350/15, slice thickness 6 mm, slice number 3, NEX 2회, scan time은 15 초로 하여 5 분 동안 20회 영상을 얻었다. 가시적으로 조영증강이 없는 종양의 주변부위나 수술경계부위에 관심영역을 그려서 시간신호강도곡선을 얻었으며, 첫 회 조영제 통과시의 peak 이후에 신호가 감소하는 경우를 Normal pattern으로, peak 이후에 신호가 계속 유지되거나 증가하는 경우를 Tumor pattern으로 하였으며, Normal pattern과 Tumor pattern을 보인 예들을 구분하여 종양의 재성장 상태와 환자의 생존 기간을 비교 관찰하였다.

  • PDF

확산텐서영상에서 확산경사자장의 방향수에 따른 FA값 및 FA의 표준편차와의 상관 관계

  • 이영주;황문정;배성진;장용민;우성구;서수지
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.33-33
    • /
    • 2003
  • 목적: 확산텐서영상 획득시 확산경사자장의 방향수와 FA값, 그리고 FA값의 표준편차와의 상관관계를 조사해 보고자 하였다. 대상 및 방법: 3T MR scanner에서 정상성인 10명(남자 5명, 여자 5명)을 대상으로 걸어주는 확산강조 경사자장의 수(N = 6, 11, 23, 35, 47)를 증가시키며 확산텐서영상을 획득하였다. 획득된 영상들로부터 FA map을 만들고 주요 뇌구조물(frontal GM, putamen, posterior limb of internal capsule, thalamus 등)에 관심영역을 설정하여 FA값을 측정하였으며 그 FA값의 표준편차(sd) 를 계산하였다. 이때 사용한 펄스열은 Stejskal-Tanner type의 확산강조 경사자장이 포함된 single-shot SE EPI를 사용하였으며 영상획득시 사용한 피라미터는 다음과 같다. TR/TE=8000ms/71ms, Thickness/spacing=5/2mm, FOV=240mm, Matrix=$128{\times}128$, NEX= 1, b value=1000s/$\textrm{mm}^2$.

  • PDF

Design of a Multi-Stripline Loaded On-Glass Antenna for T-DMB Applications (다중 선로가 로딩된 T-DMB 수신용 차량 글래스 안테나 설계)

  • Kang, Woo-Joong;Kay, Young-Chul;Park, Seul-Gi;Oh, Jung-Hun;Choo, Ho-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.7
    • /
    • pp.664-672
    • /
    • 2009
  • In this paper we propose an on-glass antenna which consists of conducting dual center striplines and multi-loaded striplines. Multi-loaded striplines and dual center lines were employed for achieving a broad matching bandwidth and improving a vertical radiation gain, respectively. The detail design parameters were determined using the Pareto genetic algorithm with an full wave EM simulator. The optimized design was built and installed on a commercial vehicle, and the antenna performances such as the return loss and the radiation gain were measured in a semi-anechoic chamber. The measurement results showed the matching bandwidth($S_{11}$<-3 dB) of about 49 % in the T-DMB frequency band, the vertical gain of about -3 dBi along the bore-sight direction, and the average gain of about -10 dBi along the azimuth direction.

A Study on Comparative Analysis of Diffusion Weighted Image Examination before and after Contrast Injection (조영제 사용 전 후 확산강조영상 검사의 비교 분석에 대한 연구)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.51-57
    • /
    • 2009
  • The purpose of this study would evaluate if having clinical effects on diffusion image with quantitative analysis through ADC values of brain's normal tissue and lesions before and after contrast injections using a 3.0T. From November in 2007 until December in 2008, a total of 32 patient was performed on 3.0T(Signa Excite, GE Medical System, USA) with the normal or lesions in the patient who requests diffusion weighted image with 8channel head coil. The pulse sequence was used with spin echo EPI(TR: 10000msec, TE: 72.2 msec, Matrix: 128*128, FOV: 240 mm, NEX: 1, diffusion direction: 3, b-value: 1000). Measurement results of ADC values on lesions, CSF, white matter, gray matter, lesions after contrast injection were measured less 75% than before contrast injection, infarction: 100%, CSF: 78%(high), white matter: 71.4%(low), gray matter: 50%(high, low). The results of paired t-test on the deference of ADC values which statically is significant in three(lesions, CSF, white matter)regions except for white matter(p<0.05). Quantitative analysis of lesions, CSF, white matter, gray matter have difference on all regions. ADC values were low in lesions and white matter, normal CSF after contrast injection commonly is high than before contrast injection, ADC values which white matter were high and low (50:50) after contrast injection. 3.0T diffusion weighted image clinically supposed that performing DWI examination after contrast injection was not desirable because of having effects on brain tissue.

  • PDF

Development of Smart Wireless Measurement System for Monitoring of Bridges (교량 모니터링을 위한 스마트 무선 계측 시스템 개발)

  • Heo, Gwang Hee;Lee, Woo Sang;Lee, Chin Ok;Jeon, Joon Ryong;Sohn, Dong Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.2
    • /
    • pp.170-178
    • /
    • 2011
  • In this paper, a research was performed to develop a wireless measurement system for bridge monitoring using MEMS sensor and bluetooth wireless communication module. First, in order to prove the suitability of MEMS sensor for the bridge measurement, its ranges of measuring acceleration and of frequency response were experimented. Also, the quality of wireless communication was tested by an experiment on long-distance communication for the knowledge of maximum communication distance, and also by an experiment on the data transmit-receive capability both inside and outside of a steel box bridge. Later, placing the wireless acceleration sensor system that had been developed in our lab on a bridge in public service, we acquired vibration data from the bridge under traffic load and analyzed its dynamic characteristics in realtime. For the analysis of the data, NExT & ERA algorithm were employed. The result of analysis was compared to the FE analysis of the same bridge, and the comparison made it possible to evaluate the performance of wireless acceleration sensor system. As a result, it was proven that the wireless acceleration sensor system developed with the use of MEMS sensor and bluetooth wireless communication module could be effectively applied to the measurement of structure whose vibration feature was low frequency like a bridge.

Modal identification of Canton Tower under uncertain environmental conditions

  • Ye, Xijun;Yan, Quansheng;Wang, Weifeng;Yu, Xiaolin
    • Smart Structures and Systems
    • /
    • v.10 no.4_5
    • /
    • pp.353-373
    • /
    • 2012
  • The instrumented Canton Tower is a 610 m high-rise structure, which has been considered as a benchmark problem for structural health monitoring (SHM) research. In this paper, an improved automatic modal identification method is presented based on a natural excitation technique in conjunction with the eigensystem realization algorithm (NExT/ERA). In the proposed modal identification method, damping ratio, consistent mode indicator from observability matrices (CMI_O) and modal amplitude coherence (MAC) are used as criteria to distinguish the physically true modes from spurious modes. Enhanced frequency domain decomposition (EFDD), the data-driven stochastic subspace identification method (SSI-DATA) and the proposed method are respectively applied to extract the modal parameters of the Canton Tower under different environmental conditions. Results of modal parameter identification based on output-only measurements are presented and discussed. User-selected parameters used in those methods are suggested and discussed. Furthermore, the effect of environmental conditions on the dynamic characteristics of Canton tower is investigated.

Comparison of Fractional Anisotropy Values of Corticospinal Tract and Corpus Callosum between 6- and 25-Direction Diffusion Tensor Images in Normal Subjects

  • Lee, Jeong-Hyun;Lee, Sun-Young;Kim, Hyun-Jeong;Park, Choong-Gon;Lee, Deok-Hee;Lee, Ho-Kyu;Kim, Sang-Joon;Suh, Dae-Chul
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.20-20
    • /
    • 2003
  • Purpose: To investigate the difference of fractional anisotropy (FA) values between 6- and 25-direction diffusion tensor images (DTI) in normal adult brain. Materials and Methods: DTI was peformed in 28 normal subjects (15 subjects with 6-direction, 13 subjects with 25-direction) in a 1.5 T MR system. DTI was done with SE-EPI sequence with TR/TE/NEX 10000/84/1, 5mm slice thickness and b=1000 s/mm2. FA values were measured from 8 different anatomical locations which included both cerebral peduncles, both posterior limbs of the internal capsules, both corona radiata, genu and splenium of the corpus callosum. Statistical difference of FA was tested between 6-and 25-direction DTI.

  • PDF

Comparison between Field Test and Numerical Analysis for a Jacket Platform in Bohai Bay, China

  • Yang He-Zhen;Park Han-Il;Choi Kyung-Sik;Li Hua-Jun
    • Journal of Ocean Engineering and Technology
    • /
    • v.20 no.2 s.69
    • /
    • pp.1-7
    • /
    • 2006
  • This paper, presents a comparison between numerical analysis and field test on a real offshore platform in Bohai Bay, China. This platform is a steel jacket offshore platform with vertical piles. The field testing under wave-induced force and wind force etc. was conducted, in order to obtain the dynamic parameters of the structure, including the frequencies of the jacket platform, as well as the corresponding damping ratios and mode shapes. The natural excitation technology (NexT) combined with eigensystem realization algorithm (ERA) and the peak picking (PP) method in frequency domain are carried out for modal parameter indentification under operational conditions. The three-dimeansional finite element model (FEM) is constructed by ANSYS and analytical modal analysis is performed to generate modal parameters. The analytical results were compared with experimental results. A good agreement was achieved between the finite element and analysis and field test results. It is further demonstrated that the numerical and experimental modal analysis provide a comprehensive study on the dynamic properties of the jacket platform. According to the analysis results, the modal parameters identification under ambient excitation can calibrate finite element model of the jacket platform structures, or can be used for the structural health monitoring system.