• Title/Summary/Keyword: NEMA

Search Result 155, Processing Time 0.031 seconds

Standard Performance Measurements of GE $Advance^{TM}$ Positron Emission Tomography (GE $Advance^{TM}$ 양전자방출단층촬영기의 표준 성능평가)

  • Jeong, Ha-Kyu;Kim, Hee-Joung;Son, Hye-Kyung;Bong, Jung-Kyun;Jung, Hai-Jo;Jeon, Tae-Joo;Kim, Jae-Sam;Lee, Jong-Doo;Yoo, Hyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.2
    • /
    • pp.100-112
    • /
    • 2001
  • Purpose: The purpose of this study was to establish optimal imaging acquisition conditions for the GE $Advance^{TM}$ PET imaging system by performing the acceptance tests designed by National Electrical Manufacturers Association (NEMA) protocol and General Electric Medical Systems (GEMS) test procedures. Materials and Methods: Performance tests were carried out with $^{18}FDG$ radioactivity source and phantoms by using a standard acquisition mode. Transaxial resolution and scatter traction tests were performed with a line source and axial resolution with a point source, respectively. A cylindrical phantom made of polymethylmethacrylate (PMMA) was used to measure sensitivity, count rate losses and randoms, uniformity correction, and attenuation inserts were added to measure remaining tests. The test results were acquired in a diagnostic acquisition mode and analyzed mainly on high sensitivity mode. Results: Transaxial resolution and axial resolution were measured as average of 4.65 mm and 3.98 mm at 0 cm, and 6.02 mm and 6.71 mm at 20 cm on high sensitivity mode, respectively. Average scatter fraction was 9.87%, and sensitivity was $225.8kcps/{\mu}Ci/cc$ of trues. Activity at 50% deadtime was $4.6{\mu}Ci/cc$, and the error of count rate correction at that activity was from 1.49% to 3.83%. Average nonuniformity for total slice w3s 8.37%. The accuracy of scatter correction was -0.95%. The accuracies of attenuation correction were 5.68% for air, 0.04% for water and -6.51% for polytetrafluoroethylene (PTFE). Conclusion: The results satisfied most acceptance criteria, indicating that the GE $Advance^{TM}$ PET system can be optimally used for clinical applications.

  • PDF

Fire Occurrence Pattern Analysis and Fire Risk Calculation of Jinju City (진주시 화재발생 패턴분석과 위험등급 산출)

  • Bae, Gyu Han;Yoo, Hwan Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.4
    • /
    • pp.151-157
    • /
    • 2014
  • Diverse and complex facilities have been on the increase in urban areas in accordance with rapid urbanization. Along the lines of the increase in facilities, the risk of fire has increased. In particular, fire accidents as well as traffic accidents accounted for the highest rate in artificial disasters. Therefore, the National Fire Information Systems managed by the National Emergency Management Agency (NEMA) appeared for the effective fire management. The NEMA has provided the public with the Internet services regarding information about fire outbreak since 2007. This study acquired data from both NEMA and the Jinju City Fire Department. It constructed the fire data of Jinju City and calculated the change in spatial density targeting fire, occurred in Jinju city with a view to examining the fire risk of facilities by conducting a time series analysis on the trends of fire outbreak over a span of periods between 2007 and 2013. It also conducted an analysis of Moran's I, Getis-Ord Gi. Therefore, it came to select higher hot spots in terms of fire location and fire density. In addition, it attempted to calculate the levels of fire hazard by drawing up the matrix of personal injury and property damage, depending on facilities to present the methods, which can predict the risk of fire occurrence in urban areas.

Establishment of Quality Control System for Angiographic Unit (IVR장치의 성능 평가 기준 개발)

  • Kang, Byung-Sam;Son, Jin-Hyun;Kim, Seung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.236-244
    • /
    • 2011
  • Recently, the number of interventional procedures has increased dramatically as an alternative of invasive surgical procedure. The need for the quality control program of the angiographic units has also increased, because of concerns about the increased patient dose and the importance of image quality of angiographic units for the successful procedures. The purpose of this study was to propose an optimal guideline for the quality control program of the angiographic units. We reviewed domestic and international standards about medical imaging system and we evaluated the quality of 61 angiographic units in Korea with the use of NEMA 21 phantom. According to the results of our study, we propose a guideline for the quality control program of the angiographic units. Quality control program includes tube voltage test, tube current test, HVL test, image-field geometry test, spatial resolution test, low-contrast iodine detectability test, wire resolution test, phantom entrance dose test. Proposed reference levels are as follows: PAE < $\pm$ 10% in tube voltage test, PAE < $\pm$ 15% in tube current test, minimum 2.3 mmAl at 80 kVp in HVL test, minimum 'acceptable' level at image-field geometry test, 0.8 lp/mm for detector size of 34-40cm, 1.0 lp/mm for detector size of 28-33cm, 1.2 lp/mm for detector size of 22-27cm in spatial resolution test, minimum 200mg/cc in low contrast iodine detectability test, phantom entrance dose should be under 10R/min, 0.012 inch wire should be seen at static wire resolution test, and 0.022 inch wire should be seen at moving wire resolution test.

Development of Bladder Phantom and Image Evaluation of Lesion in the Vicinity according to Filling and Empty Bladder (방광 팬텀 제작을 통한 충만여부에 따른 방광 주변 병변에 대한 영상 평가)

  • Park, Chan-Rok;Kim, Jae-Il;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.24-27
    • /
    • 2016
  • Purpose In this study, we evaluated image quality of lesion in the vicinity according filling and empty bladder developing bladder phantom. Materials and Methods Bladder phantom was developed by modifying NEMA IEC body phantom. Air-balloon was described as bladder and 6 insert were set as lesion in the vicinity bladder according to distance. The images were evaluated in terms of % BV, comparison of SUV and peak count rate (Single, Random and True count). Results % BV was decreased far away from bladder. There were different for SUV about $7.8{\pm}3.8%$ between filling and empty bladder. True count rate was decreased about 38 %. Single and random count were increased about 44, 61%. Conclusion When the lesion is close to bladder, noise is increased. That's why prior to PET-CT scan, It is important to urinate. and It helps patient to get the accurate result.

  • PDF

Dose Reduction According to the Exposure Condition in Intervention Procedure : Focus on the Change of Dose Area and Image Quality (인터벤션 시 방사선조사 조건에 따른 선량감소 : 면적선량과 영상화질 변화를 중심으로)

  • Hwang, Jun-Ho;Jung, Ku-Min;Kim, Hyun-Soo;Kang, Byung-Sam;Lee, Kyung-Bae
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.393-400
    • /
    • 2017
  • The purpose of this study is to suggest a method to reduce the dose by Analyzing the dose area product (DAP) and image quality according to the change of tube current using NEMA Phantom. The spatial resolution and low contrast resolution were used as evaluation criteria in addition to signal to noise ratio (SNR) and contrast to noise ratio (CNR), which are important image quality parameters of intervention. Tube voltage was fixed at 80 kVp and the amount of tube current was changed to 20, 30, 40, and 50 mAs, and the dose area product and image quality were compared and analyzed. As a result, the dose area product increased from $1066mGycm^2$ to $6160mGycm^2$ to 6 times as the condition increased, while the spatial resolution and low contrast resolution were higher than 20 mAs and 30 mAs, Spatial resolution and low contrast resolution were observed below the evaluation criteria. In addition, the SNR and CNR increased up to 30 mAs, slightly increased at 40 mAs, but not significantly different from the previous one, and decreased at 50 mAs. As a result, the exposure dose significantly increased due to overexposure of the test conditions and the image quality deteriorated in all areas of spatial resolution, low contrast resolution, SNR and CNR.

Analysis of Dosimeter Error and Need for Calibration Guideline by Comparing the Dose Area of the Built-in Dose Area Product and the Moving Dose Area Product when using Automatic Exposure Controller in Intervention (인터벤션에서 자동노출제어장치 이용 시 내장형 면적 선량계와 이동형 면적 선량계의 면적선량 비교를 통한 선량계 오차분석과 교정지침 필요성 연구)

  • Choi, Ji-An;Hwang, Jun-Ho;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.11
    • /
    • pp.508-515
    • /
    • 2018
  • The purpose of this study was to analyze the errors of the built - in dose area product and the calibrated moving dose area product when using automatic exposure controller of the interventional equipment. And then, the importance of the dosimeter calibration and the necessity of the calibration guideline were investigated. The experimental method was to assemble the phantom into Thin, Normal, and Heavy Adult according to the NEMA Phantom manual and to measure the dose area with the built-in dose area product and the moving dose area product. As a result, in all thicknesses, the built-in dose area product showed higher doses than the moving dose area product, and the thicker the thickness, the larger the difference. In addition, paired t-test was performed for each item and there was a significant difference in each item between p<0.05. In conclusion, considering the intervention which is highly exposed to the radiation exposure, it is that we have to know the accurate dose when using the AEC of the equipment. And there is no calibration guide for the built-in dose area meter, thus calibration guidelines should be prepared.

양전자방출단층촬영(PET)에서 몬테-칼를로 모사계산에 의한 산란분획 평가

  • 신동휘;최진주;이정림;최창운;임상무;홍성운
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.741-745
    • /
    • 1998
  • 양전자방출단층촬영 영상획득시 수반되는 산란분획의 분포를 Monte-Carlo simulation을 이용하며 평가하고자 하였다. 모사계산에서는 GE Advance PET 스캐너와 NEMA 규정에 의한 팬텀을 모델화하였고 선상선원을 대상으로 평균 산란분획 10.2%와 산란방사선의 축방향 분포를 구하였다. 방사선원 F-18을 사용한 실제 측정의 평균산란 분획 9.16%와 산란방사선 분포를 비교하여 유사한 결과를 얻었다.

  • PDF

Regulation Experience on Harmonics Distortion in Nuclear Power System (원전 전력계통 고조파왜형률 규제 경험)

  • Moon, Su-Cheol;Kim, Bok-Ryul;Kim, Kern-Joong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.290-291
    • /
    • 2011
  • 전력산업이 발전함에 따라 전력품질 요구도 증가하고 있으나 고조파왜형률에 대한 국제기준이 제조사와 운영자의 입장에 따라 계산방법이 상충되는 부분이 현실적으로 존재하고 있는 것으로 검토되었다. 본 논문에서는 원자력발전소에 사용되는 축전지 및 충전기의 시험 및 관리규격인 ANSI/IEEE 519와 NEMA PE-5에 대한 THD 계산방식에 대한 차이점을 설명하고 현장 규제경험 사례를 통해 바람직한 관리 방향을 제시하고자 한다.

  • PDF

DICOM-based Tele-radiology System (DICOM-based 원격 진단 시스템)

  • Lee, S.H.;Ahn, C.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.71-73
    • /
    • 1995
  • In this paper, we reviewed the ACR-NEMA Digital Imaging and Communications in Medicine (DICOM) standard that was developed for medical imaging equipments interconnected on the standard networks. We also built a simple system that can transmit JPEG compressed DICOM file on network environment and display this medical image on remote-machine.

  • PDF

Nalidixic Acid Prodrugs: Amides from amino acid ester and nalidixic acid

  • Taori, Ashish;Nema, Rajesh;Kohli, D.V.;Uppadhyay, R.K.
    • Archives of Pharmacal Research
    • /
    • v.14 no.1
    • /
    • pp.48-51
    • /
    • 1991
  • Amides from amino acid ester and nalidixic acid were synthesized. The solubility characteristics and partition coefficient of the compounds were studied. The hydrolysis of the compounds was studied in the simulated gastric fluid and simulated intestinal fluid. Some compounds showed better antibacterial activity than nalidixic acid.

  • PDF