• Title/Summary/Keyword: NEC

Search Result 233, Processing Time 0.035 seconds

Effect of Prenatal Antibiotic Exposure on Neonatal Outcomes of Preterm Infants

  • Kim, Hyunjoo;Choe, Young June;Cho, Hannah;Heo, Ju Sun
    • Pediatric Infection and Vaccine
    • /
    • v.28 no.3
    • /
    • pp.149-159
    • /
    • 2021
  • Purpose: Antibiotic exposure during pregnancy may affect the fetus and newborn in many ways. This study investigated the impact of prenatal antibiotic exposure duration on neonatal outcomes in very preterm (VP) or very low birth weight (VLBW) infants. Methods: From September 2015 to December 2020, preterm infants with gestational age less than 32 weeks or with a BW less than 1,500 g who were admitted to the neonatal intensive care unit, and their mothers were enrolled. Prenatal antibiotic exposure was defined as antibiotics received by mothers before delivery, and the patients were categorized into the non-antibiotic group, short-duration (SD; ≤7 days) group, or long-duration (LD; >7 days) groups. Results: A total of 93 of 145 infants were exposed to prenatal antibiotics, among which 35 (37.6%) were in the SD group and 58 (62.4%) were in the LD group. Infants in the LD group had a significantly higher birth weight-for-gestational-age (BW/GA) Z-score than those in the non-antibiotic group, even after the adjustment for confounding factors (beta, 0.258; standard error, 0.149; P<0.001). Multivariate logistic regression analysis showed that prolonged prenatal antibiotic exposure was independently associated with death (adjusted odds ratio [aOR], 8.926; 95% confidence interval [CI], 1.482-53.775) and composite outcomes of death, necrotizing enterocolitis (NEC), and late-onset sepsis (LOS) (aOR, 2.375; 95% CI, 1.027-5.492). Conclusions: Prolonged prenatal antibiotic exposure could increase the BW/GA Z-score and the risk of death and composite outcomes of death, NEC, and LOS in VP or VLBW infants.

Morbidity and Mortality Trends in Preterm Infants of <32 Weeks Gestational Age with Severe Intraventricular Hemorrhage : A 14-Year Single-Center Retrospective Study

  • Eui Kyung Choi;Hyo-jeong Kim;Bo-Kyung Je;Byung Min Choi;Sang-Dae Kim
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.3
    • /
    • pp.316-323
    • /
    • 2023
  • Objective : Owing to advances in critical care treatment, the overall survival rate of preterm infants born at a gestational age (GA) <32 weeks has consistently improved. However, the incidence of severe intraventricular hemorrhage (IVH) has persisted, and there are few reports on in-hospital morbidity and mortality. Therefore, the aim of the present study was to investigate trends surrounding in-hospital morbidity and mortality of preterm infants with severe IVH over a 14-year period. Methods : This single-center retrospective study included 620 infants born at a GA <32 weeks, admitted between January 2007 and December 2020. After applying exclusion criteria, 596 patients were included in this study. Infants were grouped based on the most severe IVH grade documented on brain ultrasonography during their admission, with grades 3 and 4 defined as severe. We compared in-hospital mortality and clinical outcomes of preterm infants with severe IVH for two time periods : 2007-2013 (phase I) and 2014-2020 (phase II). Baseline characteristics of infants who died and survived during hospitalization were analyzed. Results : A total of 54 infants (9.0%) were diagnosed with severe IVH over a 14-year period; overall in-hospital mortality rate was 29.6%. Late in-hospital mortality rate (>7 days after birth) for infants with severe IVH significantly improved over time, decreasing from 39.1% in phase I to 14.3% in phase II (p=0.043). A history of hypotension treated with vasoactive medication within 1 week after birth (adjusted odds ratio, 7.39; p=0.025) was found to be an independent risk factor for mortality. When comparing major morbidities of surviving infants, those in phase II were significantly more likely to have undergone surgery for necrotizing enterocolitis (NEC) (29.2% vs. 0.0%; p=0.027). Additionally, rates of late-onset sepsis (45.8% vs. 14.3%; p=0.049) and central nervous system infection (25.0% vs. 0.0%; p=0.049) were significantly higher in phase II survivors than in phase I survivors. Conclusion : In-hospital mortality in preterm infants with severe IVH decreased over the last decade, whereas major neonatal morbidities increased, particularly surgical NEC and sepsis. This study suggests the importance of multidisciplinary specialized medical and surgical neonatal intensive care in preterm infants with severe IVH.

Design of LNA and Mixer for Ku-band Receiver (Ku 밴드 수신단을 위한 저잡음 증폭기 및 주파수 혼합기 설계)

  • Choi, Hyuk-Jae;Ko, Jae-Hyeong;Kim, Koon-Tae;Lee, Je-Kwang;Kim, Hyeong-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.257-262
    • /
    • 2012
  • The Ministry of Information-Communication assigned 18~19GHz frequency band for communication of cabins and platform to link between subway/train and it's station. In this paper, we propose wireless transmission devices which are 2 stage hybrid low noise amplifier of 18GHz band and mixer for 18GHz as well to apply for RF receiver. We designed LNA to be noise matched its 1st stage and gain matched for 2nd stage and mixer using $180^{\circ}$ hybrid coupler to suppress the spurious signal. The transistors of 18 GHz LNA and mixer are NE3210S01 of NEC and KMB-N51-1, respectively. As the result of simulation, we get 19.92dB gain and 2.06dB noise figure with LNA and 8.61dB conversion loss with mixer.

Recognition of the 3-D motion of a human arm with HIGIPS

  • Yao, Feng-Hui;Tamaki, Akikazu;Kato, Kiyoshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1724-1729
    • /
    • 1991
  • This paper gives an overview of HIGIPS design concepts and prototype HIGIPS configuration, and discusses its application to recognition of the 3-D motion of a human arm. HIGIPS which employs the combination of pipeline architecture and multiprocessor architecture, is a high-speed, high-performance and low cost N * M multimicroprocessor parallel machine, where N is the number of pipeline stages and M is the number of processors in each stage. The algorithm to recognize the motion of a human arm with a single TV camera was developed on personal computer (NEC PC9801 series). As a constraint condition, some simple ring marks are used. Each joint of the arm is attached with a ring mark to obtain its centroid position when the arm moves. These centroid positions in the three-dimensional space are linked at each of the successive pictures of the moving arm to recover its overall motion. This algorithm takes about 2 seconds to process one image frame on the general-purpose personal computer. This paper mainly discuses how to partition this algorithm and execute on HIGIPS, and shows the speed up. From this application, it is clear that HIGIPS is an efficient machine for image processing and recognizing.

  • PDF

Characterization of Potato Scab Pathogens (Streptomyces Species) in Korea

  • Park, Duck-Hwan;Shrestha, Rosemary;Hur, Jang-Hyun;Lim, Chun-Keun
    • Proceedings of the Microbiological Society of Korea Conference
    • /
    • 2005.05a
    • /
    • pp.162-165
    • /
    • 2005
  • Potato scab, an important disease that affects developing tubers, causes a major problem in potato cultivation. The major potato cultivation areas in Korea are located in two Northern provinces, Gangwon and Gyeonggi, and two Southern provinces, Jeju island, and South Jeolla. In these areas, potato scab is widely distributed and has caused severe problem in potato cultivation. Therefore, potato-growing areas were surveyed for identification and distribution of potato scab pathogens from 1996 to 1999. Pathogenic Streptomyces strains were isolated from potato scab lesions and six representative Streptomyces species were characterized based on their phenotypic and molecular characteristics including, pathogenicity, physiological and morphological properties, analyses of 16SrRNA genes and 16S-23S ITS region, DNA relatedness, production of thaxtomin A, and the presence of nec1 and ORFtnp gene homologs. Three species were identified as previously described Streptomyces scabies, S. turgidiscabies, and S. acidiscabies, while other three species having distinct phenotypics properties were identified as novel S. luridiscabiei, S. puniciscabiei, and S. niveiscabiei.

  • PDF

The Effect of Hydride Phase on the Hydrogen Sorption Properties of the Non-Evaporable Ti0.3Zr0.2V0.5 Getter Alloy (Ti0.3Zr0.2V0.5 합금의 수소흡수 특성에 미치는 수소화물의 영향)

  • Lee Dongjin;Park Jeshin;Suh Changyoul;Lee Jaechun;Kim Wonbaek
    • Korean Journal of Materials Research
    • /
    • v.15 no.5
    • /
    • pp.306-312
    • /
    • 2005
  • The hydrogen sorption properties of $Ti_{0.3}Zr_{0.2}V_{0.5}$ NEC(non-evaporable getter) alloy and its hydrides were evaluated at room temperature. The alloy and hydride powders were prepared by the Hydride-DeHydride(HDH) method. The hydrogen sorption speed of $Ti_{0.3}Zr_{0.2}V_{0.5}$ alloy was measured to increase with the amounts of hydride phase in the getter. The hydrogen sorption speeds of $Ti_{0.3}Zr_{0.2}V_{0.5},\;(Ti_{0.3}Zr_{0.2}V_{0.5})H_{1.52},\;and\;(Ti_{0.3}Zr_{0.2}V_{0.5})H_{1.94}$ were 2.22, 3.14 and 5.08 liter/sec, respectively. The unexpected enhancement of hydrogen sorption speed with the presence of the hydride phase is considered to be due to the pre-saturation of hydrogen trap sites which can retard the diffusion of hydrogen in the alloy.

A Study on Reduction Factor in Allowable Current of IEC Low-Voltage Wire (IEC 저압간선의 허용전류 감소계수에 관한 연구)

  • Song, Young-Joo;Lim, Myung-Hwan;Choi, Dae-Won;Kim, Do-Hyung;Yeum, Sung-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.100-108
    • /
    • 2010
  • A low voltage wire should be used considering that a load used in the end is a low voltage. In regard to these wires, there are needs for research about the wire thickness calculation in accordance with IEC standard because the standardization process for IEC (KS standard) was completed on June 30, 2005, and they stopped producing NEC-standard products by the order from Korean Agency for Technology and Standards under Ministry of Knowledge Economy (former Ministry of Commerce, Industry and Energy) since July 1, 2006. This study compared, in terms of the thickness calculation of low voltage wire, a reduction factor application by IEC standard about allowed current and an application for calculation of voltage drop. It also proposed the formula for IEC standard to decrease errors and resolve the difficulty of standardized calculation by analyzing the difference between simplified formula and standardized formula that are the most frequently used calculation method of voltage drop.

A Study on the EMFG Representation of Timing Diagrams (타이밍도의 EMFG 표현에 관한 연구)

  • 김영운;여정모
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.05a
    • /
    • pp.179-184
    • /
    • 1999
  • A Timing Diagram is almost used to represent the various signals such as an address bus, a data bus, and the control signals during design and analysis of a digital system. But if so, its representation is somewhat complicated and also it is difficult to analyze the operation of the system. In this paper, we proposed the representation method of timing diagrams with the EMFG(Extended Mark Flow Graph). In the EMFG representation of the system operation, the logical states due to the various signals of the system is graphically represented. Therefore the proposal method allows that it is easy to design as well as analyze the system. As examples applied, we represented the memory read cycle of $\mu$PD70320 CPU and the read cycle of MCM60256A memory with the EMFG.

  • PDF

Observation on Neck Form of Young Japanese Women for Clothing DesignII-Analysis of Horizontal Sectional Neck Serface & Draft of Neck Serface Using 3-D Data- (의복설계를 위한 성인여성의 유형형태의 관찰II-3차원 계측법에 의한 유형의 횡단면도 및 체표면전개도의 분석 ,일본 여자대학생을 중심으로-)

  • 김희숙
    • Journal of the Korean Society of Costume
    • /
    • v.36
    • /
    • pp.139-148
    • /
    • 1998
  • In order to know what sorts of features of neck form may be required to make plans for tight collars, the neck form of young japanese women were measured three demension-ally using GRASP(Grating Projection System for Profiling) and plaster torso. By the BASIC language in NEC computer and EXCEL program in MACINTOSHI computer, it became possible to draft a number of neck surface auomatically, therefore, we got analysis of a mass of subjects. Thed following results were obtained: 1. There was a large individual difference in the shape of neck, in particular, on the front and side curves of the neck base line, where the undulation of clavicular part of neck and inclination of shoulder are refracted. 2. When designing a stand collar, from the viewpoint of clothing strcture, it is important to grasp exactly the shapes of the neck, such as the line of the neck base, the neck gradient, back neck length, back neck width & girth. 3. According to the somatotypes(turing-over, standard, bending type), there were different the method of the basic collar pattern making.

  • PDF

Overview of recent developments of Korea Electrical Code of lightning protection system (한국전기규정(Korea Electrical Code) 피뢰시스템 제정(안) 해설)

  • Lee, Hyo-Jin;Lee, Kang-Hee;Lee, Geum-Hwan;Kim, Jun-Taek;Shin, Ki-Hyun;Kim, Han-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1631-1632
    • /
    • 2015
  • 기술의 발전과 사회/환경변화, WTO/TBT 및 FTA 협정 이행을 위한 국제표준 도입 등 대내 외적 환경에 능동적/선제적으로 대처하기 위하여 국제표준 수준의 규정인 한국전기규정(KEC) 제정(안)을 개발하고 있다. 한국전기규정(KEC)은 국제표준인 IEC를 근간으로 하고, 상세사항은 DIN, BS, NEC 등의 선진표준을 참조, 국내외 표준들의 비교/조사를 통한 개발을 목적으로 제정 중에 있다. 한국전기규정(KEC)은 제1편 공통분야와 제2편 저압전기설비분야, 제3편 고압전기설비분야, 제4편 지능형전력망분야 등 총 4편으로 구성되며 이 중 피뢰시스템은 IEC 62305를 기초로 하여 제정되었다. 본 논문에서 한국전기규정(KEC) 제1편 제5부 피뢰시스템분야에 대한 중요사항에 대해 제시하였다.

  • PDF