• Title/Summary/Keyword: NDT

Search Result 441, Processing Time 0.036 seconds

Evaluation of Non Destructive Inspection Interval for Running Safety of Railway Axle (철도차량 안전성을 위한 주행 차축의 비파괴 검사주기 평가)

  • Kwon, Seok Jin;Lee, Dong Hyung;Seo, Jung Won;Kim, Jae Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.9
    • /
    • pp.777-782
    • /
    • 2014
  • Usually, railway axles are designed for infinite life based on endurance limit of the material and the axle is not fractured immediately when a surface crack initiated. The railway axles have been inspected regularly by NDT such as ultrasonic testing, magnetic testing and eddy current testing and so on. Because the axle failure is profoundly influenced by the probability of missing a fatigue crack during an NDT inspection, it is necessary to evaluate the Non Destructive Interval of railway axle. In the present paper, the Non Destructive Interval of railway axle based on fracture mechanics and finite element analysis was investigated. It was shown that the Non Destructive Interval of railway axle can be evaluated using fracture mechanics approach and extended using NDT which a crack can detect clearly.

Analysis of Error Rate in the Variations of Shearing Amount in Measuring the Internal Defect using a Shearography (전단간섭계를 이용한 압력용기 내부 결함 측정시 전단량 변화에 따른 오차분석)

  • Hong, Kyung-Min;Kang, Young-June;Choi, In-Young;Ahn, Yong-Jin;Yoon, Suk-Bum
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.726-732
    • /
    • 2012
  • Pipe and Pressure Vessels that is used in power plant and chemical industry have many Internal Defects that is corrosion caused by the flow of fluid. These Internal Defects that have possibility of explosion are very dangerous because it can not see from the outside. This days many companys using NDT method to find an Internal Defect. Most of the NDT methods have limitations that are constraint of shape and materials. But Sheargoraphy have many advantages compared conventional NDT method. It has very fast measuring speed, non-destructive and non contacting measurement. As well as it hasn't constraint of shape and materials. As a paper on the analysis of measurement of error, the important factors were the Shearing Amount and pressure, and discovered measurement of the Internal Defect of the object by using shearography. The optimal Shearing Amount and pressure was discovered and utilized.

Serially multiplexed FBG accelerometer for structural health monitoring of bridges

  • Talebinejad, I.;Fischer, C.;Ansari, F.
    • Smart Structures and Systems
    • /
    • v.5 no.4
    • /
    • pp.345-355
    • /
    • 2009
  • This article describes the development of a fiber optic accelerometer based on Fiber Bragg Gratings (FBG). The accelerometer utilizes the stiffness of the optical fiber and a lumped mass in the design. Acceleration is measured by the FBG in response to the vibration of the fiber optic mass system. The wavelength shift of FBG is proportional to the change in acceleration, and the gauge factor pertains to the shift in wavelength as a function of acceleration. Low frequency version of the accelerometer was developed for applications in monitoring bridges. The accelerometer was first evaluated in laboratory settings and then employed in a demonstration project for condition assessment of a bridge. Laboratory experiments involved evaluation of the sensitivity and resolution of measurements under a series of low frequency low amplitude conditions. The main feature of this accelerometer is single channel multiplexing capability rendering the system highly practical for application in condition assessment of bridges. This feature of the accelerometer was evaluated by using the system during ambient vibration tests of a bridge. The Frequency Domain Decomposition method was employed to identify the mode shapes and natural frequencies of the bridge. Results were compared with the data acquired from the conventional accelerometers.

Improved Georeferencing of a Wearable Indoor Mapping System Using NDT and Sensor Integration

  • Do, Linh Giang;Kim, Changjae;Kim, Han Sae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.5
    • /
    • pp.425-433
    • /
    • 2020
  • Three-dimensional data has been used for different applications such as robotics, building reconstruction, and so on. 3D data can be generated from an optical camera or a laser scanner. Especially, a wearable multi-sensor system including the above-mentioned sensors is an optimized structure that can overcome the drawbacks of each sensor. After finding the geometric relationships between sensors, georeferencing of the datasets acquired from the moving system, should be carried out. Especially, in an indoor environment, error propagation always causes problem in the georeferencing process. To improve the accuracy of this process, other sources of data were used to combine with LiDAR (Light Detection and Ranging) data, and various registration methods were also tested to find the most suitable way. More specifically, this paper proposed a new process of NDT (Normal Distribution Transform) to register the LiDAR point cloud, with additional information from other sensors. For real experiment, a wearable mapping system was used to acquire datasets in an indoor environment. The results showed that applying the new process of NDT and combining LiDAR data with IMU (Inertial Measurement Unit) information achieved the best result with the RMSE 0.063 m.

Development of a truncation artifact reduction method in stationary inverse-geometry X-ray laminography for non-destructive testing

  • Kim, Burnyoung;Yim, Dobin;Lee, Seungwan
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1626-1633
    • /
    • 2021
  • In an industrial field, non-destructive testing (NDT) is commonly used to inspect industrial products. Among NDT methods using radiation sources, X-ray laminography has several advantages, such as high depth resolution and low computational costs. Moreover, an X-ray laminography system with stationary source array and compact detector is able to reduce mechanical motion artifacts and improve inspection efficiency. However, this system, called stationary inverse-geometry X-ray laminography (s-IGXL), causes truncation artifacts in reconstructed images due to limited fields-of-view (FOVs). In this study, we proposed a projection data correction (PDC) method to reduce the truncation artifacts arisen in s-IGXL images, and the performance of the proposed method was evaluated with the different number of focal spots in terms of quantitative accuracy. Comparing with conventional techniques, the PDC method showed superior performance in reducing truncation artifacts and improved the quantitative accuracy of s-IGXL images for all the number of focal spots. In conclusion, the PDC method can improve the accuracy of s-IGXL images and allow precise NDT measurements.

Effect of Neonatal Developmental Intervention Program (NDT) on Motor Development and Growth in Premature Infants

  • Park, Geun-Hwa;Choi, Sang-Youn;Kim, Sung-Mi;Kim, Mi-Ae;Lee, Eun-Ju
    • Neonatal Medicine
    • /
    • v.17 no.2
    • /
    • pp.207-216
    • /
    • 2010
  • Purpose: The aim of this study was to identify the effects of neonatal developmental intervention program (NDT) in promoting motor development and growth and to determine the usefulness of Hammersmith Neonatal Neurological Examination (HNNE) and Neonatal Behavioral Assessment Scale (NBAS) in premature infants. Methods: We performed NDT on selected premature infants (PI, n=42) and compared them with the full term control group (FC, n=20). NDT protocol and development assessment (HNNE, NBAS) were manipulated by the physical therapist in the neonatal intensive care unit. The data of this study were collected prospectively. Results: The PI with GA <34 weeks (VPI) subgroup showed a more use of mechanical ventilator and surfactant, severe bronchopulmonary dysplasia and intraventricular hemorrhage, and patent ductus arteriosus treated surgically than the PI with GA $\geq$34 weeks but less than 37 weeks (LPI) subgroup. The average scores improved significantly in the PI group between the 1st, 2nd, and 3rd assessment by repeated measure (P=0.000). Also, the PI group showed significantly higher total scores and average score at 40 weeks postmenstrual age, P=0.000, respectively than in the FC group. The LPI subgroup showed more weight gain and change in the head circumference between the 1st and 3rd assessment by repeated measure, respectively, P<0.05. The PI group showed no apnea, bradycardia and late sepsis associated with intervention and assessment. Conclusion: The NDT might be a safe and useful intervention to promote motor and growth outcomes in premature infants. Also, the HNNE and NBAS might be safe and useful tools for assessing neurodevelopment in premature infants.

Reliability Evaluation for Prediction of Concrete Compressive Strength through Impact Resonance Method and Ultra Pulse Velocity Method (충격공진법과 초음파속도법을 통한 콘크리트 압축강도 예측의 신뢰성 평가)

  • Lee, Han-Kyul;Lee, Byung-Jae;Oh, Kwang-Chin;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.18-24
    • /
    • 2015
  • Non-destructive testing (NDT) methods are widely used in the construction industry to diagnose the defects/strength of the concrete structure. However, it has been reported that the results obtained from NDT are having low reliability. In order to resolve this issue, four kinds of NDT test (ultrasonic velocity measurements by P-wave and S-wave and the impact resonance methods by longitudinal vibration and deformation vibration) were carried out on 180 concrete cylinders made with two kinds of mix proportions. The reliability of the NDT results was analyzed and compared through the measurement of the actual compressive strength of the concrete cylinders. The statistical analysis of the results was revealed that the ultrasonic velocity method by S-wave is having lowest coefficient of variation and also most capable of stable observation. Analytical equations were established to estimate the compressive strength of the concrete from the obtained NDT results by relating the actual compressive strength. Moreover the equation established by the ultrasonic velocity method by S-wave had the highest coefficient of determination. Further studies on the stability of non-destructive testing depending on various mixing conditions will be necessary in the future.