• Title/Summary/Keyword: NDIR Gas Sensor

검색결과 34건 처리시간 0.02초

비침습적 방법에 의한 광학식 Transcutaneous pCo2 가스센서 및 분석장치 개발을 위한 기초연구 (Basic Research of Non-Invasive Optical Transcutaneous pCo2 Gas Sensor & Analytic Equipment)

  • 김도억;이승하;차은종;강신원
    • 센서학회지
    • /
    • 제13권4호
    • /
    • pp.258-263
    • /
    • 2004
  • In this study, we carried out a basic study for the development of optical transcutaneous $pCO_{2}$ gas sensor and analyzer using non-invasive method. The basic principle of $pCO_{2}$ measurement is adapted Beer lambert's law and embodied the system using NDIR method. This measuring system was composed of a IR lamp, a optical filter, a optical reaction chamber, pyroelectric sensor and a signal process. We measured $EtCO_{2}'s$ concentration in basis step instead of $pCO_{2}$ gas that can collect by inflicting heat in outer skin. We minimize the size of optical reaction chamber which takes up the largest volume, to make the portable sensor. We made optical reaction chamber in Si wafer using MEMS technology and the optical reaction chamber was shortened to 2 mm and we carried out an experiment. When we injected the $EtCO_{2}$ to the inside of the optical reaction chamber, we could confirm change of 4.6 mV. The system response time was within 2 second that is fairly fast.

두 개의 동일한 타원형 구조를 지닌 광 도파관의 특성 (Characteristics of an Optical Waveguide with Two Identical Elliptical Structures)

  • 장성호;정상호;이승환
    • 한국가스학회지
    • /
    • 제18권2호
    • /
    • pp.48-54
    • /
    • 2014
  • 본 논문에서는 알코올 측정용 센서의 광학적 특성 향상을 위한 고유한 광학적 구조를 제안하였으며, 모의해석을 실시하였다. 광 도파관은 한쪽에 공통초점을 갖는 두 개의 타원형 광 도파관으로 구성되었으며, 각 광 도파관의 서로 다른 초점에 적외선 광원과 적외선 센서를 갖는다. 두 타원형 광 도파관의 각도가 30도에서 90도로 증가시켰을 때, 단위면적당 최대 입사광량은 $2.23{\times}10^6W/m^2$에서 $5.74{\times}10^5W/m^2$로 감소하였다. 그러나 조사 빔의 반지름은 1.86 mm로 최소값을 나타내었고, 전체 입사 에너지는 90도 각도를 갖는 구조와 비교하여 약 10 % 작은 값을 보였다. 모의해석 결과로부터 본 논문에 제안한 구조는 긴 흡수파장을 갖는 광학적 가스센서의 감도향상에 기여할 것으로 판단된다.

가스분석을 이용한 석탄 종류별 $CO_2$ 가스화 반응특성 연구 (Characteristics of Various Ranks of Coal Gasification with $CO_2$ by Gas Analysis)

  • 김용택;서동균;황정호
    • 한국연소학회지
    • /
    • 제15권2호
    • /
    • pp.41-49
    • /
    • 2010
  • Various coals from many countries around the world have been used for pulverized coal boiler in power plants in Korea. In this study, the gasification reactivities of various coal chars with $CO_2$ were investigated. Carbon conversion was measured using a real time gas analyzer with NDIR CO/$CO_2$ sensor. In a lab scale furnace, each coal sample was devolatilized at $950^{\circ}C$ in nitrogen atmosphere and became coal char and then further heated up to reach to a desired temperature. Each char was then gasified with $CO_2$ under isothermal conditions. The reactivities of coal chars were investigated at different temperatures. The shrinking core model (SCM) and volume reaction model(VRM) were used to interpret the experiment data. It was found that the SCM and VRM could describe well the experimental results within the carbon conversion of 0-0.98. The gasification rates for various coals were very different. The gasification rate for any coal increased as the volatile matter content increased.

가스분석을 이용한 석탄 입자크기가 촤-$CO_{2}$ 가스화 반응성에 미치는 영향 연구 (The Effect of Coal Particle Size on Char-$CO_{2}$ Gasification Reactivity by Gas Analysis)

  • 김용택;서동균;황정호
    • Korean Chemical Engineering Research
    • /
    • 제49권3호
    • /
    • pp.372-380
    • /
    • 2011
  • 촤-가스화 반응은 반응온도, 반응가스 부분압력, 시스템 총 압력, 입자크기 등 운전조건뿐만 아니라 촤의 화학적 조성 및 물리적 구조의 영향을 받는다. 본 연구에서는 두 종류의 역청탄 촤를 이용하여 반응온도 1,000-$1,400{^{\circ}C}$에서 $CO_{2}$ 가스화시 입자크기의 영향을 관찰하였다. 실험실 규모의 고정식 반응기를 이용하여 대기압 하에서 실험을 수행하였으며 반응가스인 $CO_{2}$(40 vol%)가 반응기에 공급되면 촤와 반응하여 CO를 생성하였다. 촤의 탄소 전환율을 측정하기 위하여 비분산적외선 방식의 CO/$CO_{2}$ 센서가 장착된 실시간 가스분석기를 이용하였다. 실험결과 동일한 온도에서 입자크기가 감소할수록 가스화 반응성은 증가하였으며 온도가 증가할수록 반응성에 미치는 입자크기의 영향은 더욱더 크게 증가하였다. 또한 반응성이 낮은 촤에서 입자크기의 영향은 다소 적게 나타났다. 입자크기와 석탄 종류는 반응모델에도 영향을 주었다. Shrinking core model은 반응성이 낮은 석탄을 잘 묘사했으며 반대로 Volume reaction model은 반응성이 높은 석탄을 잘 묘사하였다.