• Title/Summary/Keyword: ND:YAG laser

Search Result 1,019, Processing Time 0.024 seconds

Measurements of the Cylinder Wake with a Hybrid-Fitness Function based 3D-PTV (적합함수 기반의 3D-PTV에 의한 원주후류 측정 해석)

  • Doh, Deog-Hee;Jo, Hyo-Jae;Baek, Tae-Sil
    • Journal of the Korean Society of Visualization
    • /
    • v.6 no.2
    • /
    • pp.3-8
    • /
    • 2008
  • A new 3D-PTV algorithm(a Volume PTV) based upon a hybrid fitness function has been constructed. A coherency fitness function is introduced using the information of space and time to sort out the correct particle pairs between the two camera images. The measurement system consists of two-high-definition-cameras($1k{\times}1k$), a Nd-Yag laser and a host computer. The developed algorithm has been employed to investigate the flow features of the cylinder wake. The Reynolds numbers with the cylinder diameter(d=10 mm) are 360, 540, 720, 900, 1080 and 1260. Two-dimensional displacements of the particles of each camera's image and neighbouring constraints were introduced to reduce the calculation loads. More than 10,000 instantaneous 3D vectors have been obtained by the constructed algorithm. The constructed algorithm could recover more than $80{\sim}90%$ of the particle numbers in the image condition.

Angiodysplasia in a Child with Chronic Renal Failure: Endoscopic Hemostatic Therapy (소아 만성 신부전 환자에서 발생한 위혈관 이형성증의 Hemoclipping에 의한 지혈 치료 1례)

  • Lee, Yun-Jin;Kim, Young-Mi;Kim, Su-Young;Park, Jae-Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.6 no.2
    • /
    • pp.192-196
    • /
    • 2003
  • Angiodysplasia is the most common vascular abnormality of the gastrointestinal tract and probably the most frequent cause of recurrent lower intestinal bleeding in otherwise healthy elderly patients. Also, it is an important cause of hemorrhage in chronic renal failure observed in up to 19~32% of patients. Bleeding due to gastric angiodysplasia is treated by various endoscopic approaches, including argon and Nd : YAG laser photocoagulation, monopolar or bipolar electrocoagulation, heater probe, injection sclerotherapy, band ligation or hemoclipping. A 15-year-old boy, who had undergone hemodialysis for chronic renal failure for about 10 years, was admitted due to melena and progressive anemia. A gastroduodenoscopy revealed a cherry red and fern-like lesion with oozing on the posterior wall at junction of gastric body and fundus. Endoscopic hemoclipping therapy was performed. However, melena recurred four days later. Argon plasma coagulation and hemoclipping therapy were performed again. Since then, no recurrence of bleeding has been observed.

  • PDF

Charactericstics of Glass-Ceramic having High Efficiency Diffuse Reflectance and Fabrication of Laser Cavity (MAS계 결정화유리를 이용한 레이저 여기용 공진기의 제작 및 특성분석)

  • Park, Yong-Bae;Byun, Woo-Bong;Kim, Yo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1559-1561
    • /
    • 2002
  • 적외선 확산반사형 결정화유리를 응용한 레이저 여기용 공진기를 제작하여 미세구조 분석 및 레이저 여기 효율특성을 조사하였다. 출발물질로는 Cordierite를 주결정상으로 하는 MAS(MgO, $Al_2O_3$, $SiO_2$) 3성분계 조성에 결정화 유도용 조핵제로 $TiO_2$를 첨가하였으며, 형성된 유리 용융물을 흑연제 몰드에 부어 공진기를 제조하였다. 용융물 중 일부를 2단계 열처리를 행하여 상분석을 실시한 결과 Cordierite($2MgO{\cdot}2Al_2O_3{\cdot}5SiO_2$)와 Rutile($TiO_2$)이 주결정상으로 관찰되었으며, 열처리 온도를 변화시켜 생성된 입자의 크기에 따른 확산반사율간의 관계를 조사한 결과, $1100{\sim}1200nm$에서 열처리된 시편의 경우 $500{\sim}2200nm$의 영역에서 95% 이상의 확산반사율을 나타내었다. 대표적인 고체레이저인 Nd:YAG의 경우, $700{\sim}900nm$ 파장이 주흡수대이며, 이를 결정화유리로 제조된 공진기의 레이저 효율특성실험에 이용하였다. 수냉 및 단일 펄스의 조건에서 $1.7{\sim}1.9%$의 효율을 나타내었다.

  • PDF

A Study on Friction Behavior of Textured Surface in Unlubricated State (무윤활 상태에서 미세공이 가공된 표면의 마찰거동에 관한 연구)

  • Oh, Seok-Ju;Kim, Sung-Gi;Kim, Kyung-Woong
    • Tribology and Lubricants
    • /
    • v.25 no.4
    • /
    • pp.217-224
    • /
    • 2009
  • In this study, friction tests were carried out in order to investigate the friction behavior of textured surface in unlubricated state using ball-on-disk type apparatus. Test specimens were SUJ2 bearing steel ball and SM45C steel disk. Square arrays of circular micro-dimples were created on the surface of disk specimen by Nd:YAG Laser. Friction tests were performed for the disk specimen with various micro-dimple parameters and was also conducted for the variation of normal loads and relative velocities. The results showed that fiction coefficient of textured surface was lower than that of non-textured surface and the deeper depth of micro-dimple was, the lower friction coefficient obtained at the same diameter of micro-dimple in unlubricated state. Area density of micro-dimple had an effect on the friction coefficient. It was also found that friction coefficient generally decreased with the increase of normal load and relative velocity.

Measurement of Turbulent Intensity Distributions of a Cylinder Wake

  • Doh, Deog Hee;Cho, Gyeong Rae;Moon, Kyeong Rok;Cho, Yong Beom
    • Journal of the Korean Society of Visualization
    • /
    • v.11 no.1
    • /
    • pp.41-47
    • /
    • 2013
  • Turbulence properties of a cylinder wake (d=10 mm) have been investigated with a new volume PTV algorithm. The measurement system consists of two-high-cameras(1 $k{\times}1$ k), a Nd-Yag laser and a host computer. A fitness function representing three-dimensional coherency has been adopted to sort out spurious vectors. A hybrid fitness function representing the relations between the fitness and the three-dimensional shortest distances constructed by the two collinears of the two cameras has been also adopted. The constructed algorithm has been employed for the measurements of the cylinder wakes. The Reynolds numbers tested in this paper are 360, 540, 720, 900, 1080 and 1260. More than 10,000 instantaneous 3D vectors have been obtained by the constructed system. The volumetric distributions of the turbulence intensities (for u', v', w') indicate that clearly different patterns for all Reynolds numbers and imply that a regular pattern (like a similarity rule) for the turbulent properties exists.

Effect of Particle Migration of the Characteristics of Microchannel Flow

  • Kim Y. W.;Jin S. W.;Kim S. W.;Yoo J. Y.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.119-124
    • /
    • 2004
  • Experimental study was conducted to characterize the flow effect of particle migration in a microchannel which can be used to deliver small amount of liquids, drugs, biological agents and particles in microfluidic devices. Fluorescent particles of $1\{mu}m$ diameter were used to obtain velocity profiles of the fluid in which large particles of $10\{mu}m$ diameter were suspended at different volume fraction of 0.6 and $0.8\%$. Measurements were obtained by using micro-PIV system which contains a Nd:YAG laser with a light of 532-nm wavelength, an inverted epi-fluorescent microscope and a cooled CCD camera to record particle images. The volume fraction of $\phi$ and the particle Reynolds number $Re_p$Rep were used as a parameter to assess the influence of the velocity profile of the suspensions. To expect the slip velocity between the particle and fluids, experiments were carried out at low volume fraction. It was shown that the velocity profile was not influenced by Rep but influenced by the volume fraction, which is in similar trend with the previous study.

  • PDF

Effect of Injector-driven Type on Spray Behavior and Fuel Atomization Characteristics (인젝터 구동 방식에 따른 분무 거동 및 분무 미립화 특성)

  • Park, Ji-Hong;Suh, Hyun-Kyu;Park, Sung-Wook;Kim, Jae-Wook;Lee, Chang-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.17-24
    • /
    • 2006
  • This study was performed to figure out spray behavior and fuel atomization characteristics of a piezo-driven injector and a solenoid-driven injector in the common-rail injection system under the same design parameters and test conditions. The process of spray injection was visualized by using the spray visualization system composed of a Nd:YAG laser and an ICCD camera. The atomization characteristics were investigated in terms of axial mean velocity, Sauter mean diameter(SMD) and droplet distributions obtained from a phase Doppler particle analyzer system. Compared with solenoid-driven injector, the piezo-driven injector has short injection delay and reaches quickly to the maximum injection value. Spray tip penetration shows some difference, however, spray angle of piezo-driven injector is wider than that of solenoid-driven injector. Sauter mean diameter of piezo-driven type injector is smaller than that of solenoid-driven type.

Measurement of behaviour of Cu particles in simulated VCB using laser (레이저에 의한 모의 진공차단기 내 구리입자들의 거동 계측)

  • Choe, Joon-Yeong;Chun, Yong-Woo;Ha, Jang-Ho;Kim, Jung-Bae;Park, Won-Zoo;Lee, Gwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.543-546
    • /
    • 2000
  • 본 논문에서는, 모의 진공차단기 내에서의 구리 증기입자의 공간적 및 시간적 밀도분포를 레이저유기형광법 (LIF)에 의해 계측하였다. 레이저 트리거 방전에 의해 생성된 어블레이션(ablation) 플라즈마에서의 구리입자를 324.75nm의 Nd:YAG 레이저를 이용하여 여기시키고, 이때 여기준위에서 기저준위로 천이할 때의 형광신호(510.55nm)를 분광기 및 광전자증배관을 이용하여 계측하였다. 음극점으로부터 넓은 각도를 가지고 전자가 튀어나오며, 넓은 범위에 걸쳐 전자나 이온이 존재하는 것을 알 수 있었다. 또한 음극으로부터 8mm ( x=0, y=8mm 진 위치에서 가장 강한 신호와, 2mm ( x=0, y=2mm 가장 약한 신호를 얻을 수 있었다.

  • PDF

Internal Structure and Velocity Field of the Impinging Diesel Spray on the Wall (디젤 충돌 분무의 발달 과정 및 내부 유동 특성)

  • Chon, M.S.;Suh, S.K.;Park, S.W.;Lee, C.S.
    • Journal of ILASS-Korea
    • /
    • v.10 no.3
    • /
    • pp.1-8
    • /
    • 2005
  • The purpose of this study is to investigate the internal structure of the impinged diesel spray at various experimental conditions. To examine the effect of various factors on the development of a diesel spray impinging on the wall, experiments were conducted at the various Injection pressures, wall distances from the nozzle tip and angles of wall inclination. The PIV system consists of a double pulsed Nd:YAG laser was utilized to analyze the internal flow structure of impinged diesel sprays. The velocity fields from the PIV system were compared with the results measured by the phase Doppler particle analyzer(PDPA)system. The results show that internal flow pattern of the impinged spray was similar with the results from the PDPA system. The radial velocity of the impinged spray was increased with the increase in the injection pressure and near the nozzle-wall distance. The generation of vortex was also promoted with the Increase in angles of wall inclination.

  • PDF

Study on Macroscopic Spray and Spray Pattern Characteristics of Gasoline Direct Injection Injector for the Variation of Injection Pressure (분사압력 변화에 따른 가솔린 직접분사 인젝터의 거시적 분무와 분무패턴 특성에 관한 연구)

  • Park, Jeonghyun;Park, Suhan
    • Journal of ILASS-Korea
    • /
    • v.23 no.1
    • /
    • pp.22-29
    • /
    • 2018
  • The purpose of this study is to investigate the macroscopic spray characteristics and spray pattern of a gasoline direct injection (GDI) injector according to the increase of injection pressure. The macroscopic spray characteristics, such as a spray tip penetration and spray angle, were measured and analyzed from the frozen spray images, which are obtained from the spray visualization system including the high-speed camera, light-source, long-distance microscope (LDM). The spray pattern was analyzed through the deviation of the center of the spray plum and images were acquired using Nd: YAG Laser and ICCD(Intensified charge coupled device) camera. From the experiment and analysis, it revealed that the injection pressure have a significant influence on the spray tip penetration and spray pattern. However, the injection pressure have little influence on the spray angle. The increase of injection pressure induced the reduction of a closing delay. In addition, the deviation of spray center increase with the increase of injection pressure and the distance from a nozzle tip.