• Title/Summary/Keyword: NAL1

Search Result 85, Processing Time 0.098 seconds

A New High Efficient Bi-directional DC/DC Converter in the Dual Voltage System

  • Lee Su-Won;Lee Seong-Ryong;Jeon Chil-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.343-350
    • /
    • 2006
  • This paper introduces a new high efficient bi-directional, non-isolated DC/DC converter. Through variations of the topology of the conventional Cuk converter, an optimum bi-directional DC/DC converter is proposed. Voltage and current in the proposed DC/DC converter are continuous. Furthermore, the efficiency in both step-up and step-down mode is improved over that of the conventional bi-directional converter. To prove the validation for the proposed converter, simulations and experiments are executed with a 300W bi-directional converter.

Determination of Impurities in Aluminum by Neutron Activation Analysis

  • Kim, Nak-Bae;Bak, Hae-ill;Lee, Chul
    • Nuclear Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.29-38
    • /
    • 1980
  • A radiochemical separation scheme for the neutron activation analysis is developed for the determination of 28 elements in aluminum. The scheme is based on a group separation using ion-exchange resin and mineral exchanger. Present work has employed mineral acids and their partly organic mixture excluding HF as the media as well as common glass wares. For the determination, gamma-ray spectroscopy using $3"\times3"\;Nal(TI)$ detector and a single comparator method are used.

  • PDF

추력 30톤급 연소기의 냉각 성능

  • Cho, Won-Kook;Lee, Soo-Yong;Cho, Gwang-Rae
    • Aerospace Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.197-204
    • /
    • 2004
  • A design of regenerative cooling system of 30 ton level thrust combustion chamber for ground test has been performed. The 1-D design code has been validated by comparing with the heat flux of the NAL calorimeter for high chamber pressure and water-cooling performance of the ECC engine of MOBIS. The present design code has been confirmed to predict accurately the heat flux and water-cooling performance for high chamber pressure condition. The maximum hot-gas-side wall temperature is predicted to be about 720 K without thermal barrier coating and the coolant-side wall temperature is less than the coking temperature of RP-1. The coolant temperature rises nearly 100 K with thermal barrier coating when Jet-A1 is used as coolant.

  • PDF

Design and Analysis of a Controlled Diffusion Aerofoil Section for an Axial Compressor Stator and Effect of Incidence Angle and Mach No. on Performance of CDA

  • Salunke, Nilesh P.;Channiwala, S.A.
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.1
    • /
    • pp.20-28
    • /
    • 2010
  • This paper deals with the Design and Analysis of a Controlled Diffusion Aerofoil (CDA) Blade Section for an Axial Compressor Stator and Effect of incidence angle and Mach No. on Performance of CDA. CD blade section has been designed at Axial Flow Compressor Research Lab, Propulsion Division of National Aerospace Laboratories (NAL), Bangalore, as per geometric procedure specified in the U.S. patent (4). The CFD analysis has been performed by a 2-D Euler code (Denton's code), which gives surface Mach No. distribution on the profiles. Boundary layer computations were performed by a 2-D boundary layer code (NALSOF0801) available in the SOFFTS library of NAL. The effect of variation of Mach no. was performed using fluent. The surface Mach no. distribution on the CD profile clearly indicates lower peak Mach no. than MCA profile. Further, boundary layer parameters on CD aerofoil at respective incidences have lower values than corresponding MCA blade profile. Total pressure loss on CD aerofoil for the same incidence range is lower than MCA blade profile.

Improvement of Plants by Biotechnology (세포공학을 이용한 식물개량)

  • 윤의수
    • Korean Journal of Plant Resources
    • /
    • v.3 no.1
    • /
    • pp.1-30
    • /
    • 1990
  • The traditional plant imprownent methods consisted of pure line selection, cross breeding, heterosis breeding, polyploid breeding, mutati-onbreeding, ect.Biotechmoiogy is divided into gene spliclng , monocle-nal antibodies , protein engineering , agricultural research, and microbiological engineering. Of these , high plants deal with agricultural research, and the importent part of which is tissue culture and celLculture , Tissue .culture and cell culture are again divided into embryoculture, test tube fertilization, anther and pollen culture, somatichybridization , transformation, recombination, recombinant DNA moleculehybrid plasmid, ect For these haploid production, protoplast culture,protoplast fusion, selection and propagation, ect. , the technical sett-lement is needed.

  • PDF

A Computer Simulation for Small Animal Iodine-125 SPECT Development (소동물 Iodine-125 SPECT 개발을 위한 컴퓨터 시뮬레이션)

  • Jung, Jin-Ho;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jeong, Myung-Hwan;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.74-84
    • /
    • 2004
  • Purpose: Since I-125 emits low energy (27-35 keV) radiation, thinner crystal and collimator could be employed and, hence, it is favorable to obtain high quality images. The purpose of this study was to derive the optimized parameters of I-125 SPECT using a new simulation tool, GATE (Geant4 Application for Tomographic Emission). Materials and Methods: To validate the simulation method, gamma camera developed by Weisenberger et al. was modeled. Nal(T1) plate crystal was used and its thickness was determined by calculating detection efficiency. Spatial resolution and sensitivity curves were estimated by changing variable parameters for parallel-hole and pinhole collimator. Peformances of I-125 SPECT equipped with the optimal collimator were also estimated. Results: in the validation study, simulations were found to agree well with experimental measurements in spatial resolution (4%) and sensitivity (3%). In order to acquire 98% gamma ray detection efficiency, Nal(T1) thickness was determined to be 1 mm. Hole diameter (mm), length (mm) and shape were chosen to be 0.2:5:square and 0.5:10:hexagonal for high resolution (HR) and general purpose (GP) parallel-hole collimator, respectively. Hole diameter, channel height and acceptance angle of pinhole (PH) collimator were determined to be 0.25 mm, 0.1 mm and 90 degree. The spatial resolutions of reconstructed image of the I-125 SPECT employing HR:GP:PH were 1.2:1.7:0.8 mm. The sensitivities of HR:GP:PH were 39.7:71.9:5.5 cps/MBq. Conclusion: The optimal crystal and collimator parameters for I-125 Imaging were derived by simulation using GATE. The results indicate that excellent resolution and sensitivity imaging is feasible using I-125 SPECT.

Transdermal Permeation-enhancing Activities of some Inorganic Anions

  • Ko, Young-Il;Kim, Sung-Su;Han, Suk-Kyu
    • Archives of Pharmacal Research
    • /
    • v.18 no.4
    • /
    • pp.231-236
    • /
    • 1995
  • Effects of sodium salts of various monovalent inorganic anions on transdermal permeation of salicylic acid were investigated. In in-vitro experiment using a Franz-type diffusion cell and excisicylic acid were investigated. In-vitro experiment using a Franze-type diffusion cell and excised mouse skin, the permeation-enhancing activities of the sodium salts of inoraganic anions were rougly proportional to lyotropic Hofmeister serlling abilities of the anions l F/sup -/

  • PDF

Development of Smart Phone Application with User Fitting for Hearing Impaired in Various Environment (환경별 사용자 피팅이 가능한 스마트폰 보청기 어플리케이션 개발)

  • Lee, K.;Kang, S.-I.;Park, G.S.;Lee, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.2
    • /
    • pp.121-128
    • /
    • 2015
  • In this paper, we introduce our smart phone application for hearing impaired people. Unlike previous hearing aids application, our application has both functions of self hearing tests and sound amplification. We provide user with two types of self hearing test, those are standard hearing test and detail hearing test. Each test has different advantages like short test time and accurate test result, however both tests provide reliable result. Our hearing test allows that user can measure their hearing loss level according to the frequency. Sound amplification function provide proper fitting formula by using NAL-NL1, and it guarantees high speech intelligibility. Our application can also memorize user's fitting data at specific test condition. Therefore those who using our hearing aids application can easily reset their hearing aids / earphone properties periodically. Our application is advanced at the aspect of self fitting function that no other previous application did. So we are expecting these comfortable processes about fitting lead the number of hearing aids user to be increased.

  • PDF

Measuring Library User Satisfaction using the Public-service Customer Satisfaction Index (PCSI) (공공기관 고객만족지수(PCSI) 모형을 적용한 도서관 고객만족도 측정)

  • Kwon, Nahyun;Pyo, Soon Hee;Lee, Jungyeoun
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.52 no.1
    • /
    • pp.313-340
    • /
    • 2018
  • The purpose of this study was to design a PCSI model that can be applicable to measurement of library user satisfactions, which can be used in evaluating organizational performance. The National Assembly Library (NAL) was selected as a case to design a PCSI-based model and to test the model by conducting a self-administered survey of 341 internal and external library users. The model was validated to have a satisfactory model fit. Fitting the model, the study confirms that the service qualities of the NAL affect user satisfactions, which in turn affects organizational performances. The PCSI score of the library was 80.4, which can be used as a useful index that can compare the library's performance with other organizations in the similar public domain. Major contributions of this study are two-fold: the PCSI-based model proposed in this study provides a theoretical basis that assesses organizational performance of libraries via user satisfaction; and libraries can utilize the model as a management tool to assess the organizational performance from the user perspective.