• 제목/요약/키워드: N-current

검색결과 5,107건 처리시간 0.035초

경사 외부자장에 대한 600 kJ급 SMES용 HTS도체의 DC V-I 특성 (DC V-I Characteristics of a High Temperature Superconductor for a 600 kJ Superconducting Magnetic Energy Storage Device in an Oblique External Magnetic Field)

  • 이주영;마용호;류경우;최세용;김해종
    • 한국전기전자재료학회논문지
    • /
    • 제21권1호
    • /
    • pp.79-84
    • /
    • 2008
  • We are developing a small-sized high temperature superconducting magnetic energy storage (HTS-SMES) magnet with the nominal storage capacity of 600 kJ, which provides electric power with high quality to sensitive electric loads. Critical current and N-value of a high temperature superconductor with large current, which was selected for the development of the 600 kJ HTS-SMES magnet, were investigated in various oblique external magnetic fields. Based on the critical current and N-value measured for the short sample conductor, we discussed the DC V - I characteristic of a model coil fabricated with the same conductor of 500 m. The results show that the measured critical current and N-value of the conductor for parallel field are constant in external magnetic fields less than about 0.2 T. However, for oblique fields, its critical current and N -value abruptly decrease in all external magnetic fields. Moreover, the measured critical current of the model coil well agrees with the numerically calculated one based on the DC V - I characteristic measured for the short sample conductor. This suggest that losses and critical currents for an HTS-SMES magnet made up of a high temperature superconductor with anisotropic characteristic are predictable from the data of a short sample conductor.

Characteristics of the Polar Ionosphere Based on the Chatanika and Sondrestrom Incoherent Scatter Radars

  • Kwak, Young-Sil;Ahn, Byung-Ho
    • Ocean and Polar Research
    • /
    • 제26권3호
    • /
    • pp.489-499
    • /
    • 2004
  • The climatological characteristics of the polar ionospheric currents obtained from the simultaneous observations of the ionospheric electric field and conductivity are examined. For this purpose, 43 and 109 days of measurements from the Chatanika and Sondrestrom incoherent scatter radars are utilized respectively. The ionospheric current density is compared with the corresponding ground magnetic disturbance. Several interesting characteristics about the polar ionosphere are apparent from this study: (1) The sun determines largely the conductance over the Sondrestrom radar, while the nighttime conductance distribution over the Chatanika radar is significantly affected by auroral precipitation. (2) The regions of the maximum N-S electric field over the Chatanika radar are located approximately at the dawn and dusk sectors, while they tend to shift towards dayside over the Sondrestrom radar. The N-S component over Son-drestrom is slightly stronger than Chatanika. However, the E-W component over Chatanika is negligible compared to that of Sondrestrom. (3) The E-W ionospheric current flows dominantly in the night hemisphere over Chatanika, while it flows in the sunlit hemisphere over Sondrestrom. The N-S current over Chatanika flows prominently in the dawn and dusk sectors, while a strong southward current flows in the prenoon sector over Sondrestrom. (4) The assumption of infinite sheet current approximation is far from realistic, underestimating the current density by a factor of 2 or more. It is particularly serious for the higher latitude region. (5) The correlation between ${\Delta}H\;and\;J_E$ is higher than the one between ${\Delta}D\;and\;J_N$, indicating that field-aligned current affects ${\Delta}D$significantly.

LCD 소자 최적화의 실험적 고찰 (An Experimental Investigation of LDD Device Optimization)

  • 강대관;김달수;김현철;송낙운
    • 대한전자공학회논문지
    • /
    • 제27권3호
    • /
    • pp.72-78
    • /
    • 1990
  • 본 논문에서는 LDD 소자의 최적화의 물리적 의미를 수치 씨뮬레이션을 통해 다루었으며 관련 실험을 통하여 최적화된 LDD 구조를 해석해 보았다. 첫째, 수치해석에 의하면 최적화 조건시에 드레인 n-영역에서의 전계는 고르며 낮은 분포를 보이고 있고, 전류는 이 영역에서 넓게 퍼져 흘렀다. 아울러 이때 최적점은 모든 공정 및 전기조건을 고려하여 총체적으로 최적화하여 얻어져야함이 발견되었다. 둘째, 실험에 의하면 최적 조건의 경우 기판전류와 드레인 전류비에 의해 n-영역의 최대전계는 극소화되었다. 이때 소자의 수명은 최대가 되었으며 n-영역의 저항은 channel 저항에서 $n^+$ 접합 저항으로 유연하게 변환이 되었다.

  • PDF

100 ns급 대용량 자기펄스 압축시스템의 최적화 (Optimization of the Large Scale Magnetic Pulse Compression System of 100 ns-order)

  • 이용우;이영우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 추계종합학술대회
    • /
    • pp.442-445
    • /
    • 2003
  • 본 연구에서는 엑시머 레이저 여기용으로 40 J급 자기펄스압축시스템(WC : magnetic pulse compression system)을 개발하고, MPC의 각단에서 최적조건을 구하였다. MPC 시스템은 DC 전원 공급기, 펄스 트랜스, 네 단의 포화인덕터로 이루어져 있다. MPC 각 단에서 포화인덕터의 회전수는 140회, 26회, 5회와 1회이며, 각단에서의 최적 용량는 각각 34 nF, 28.9 nF, 22.1 nF, 22.1 nF이다. MPC 시스템의 개선으로 우리는 43 kV의 전압, 8.25 kA의 전류와 360 ns의 펄스폭을 얻을 수 있었으며, 이때 최대 펄스 압축율은 77.7, 전류 이득은 71.7이었다.

  • PDF

Transparent Phosphorus Doped ZnO Ohmic Contact to GaN Based LED

  • Lim, Jae-Hong;Park, Seong-Ju
    • 한국재료학회지
    • /
    • 제19권8호
    • /
    • pp.417-420
    • /
    • 2009
  • This study develops a highly transparent ohmic contact using phosphorus doped ZnO with current spreading for p-GaN to increase the optical output power of nitride-based light-emitting diodes (LEDs). The phosphorus doped ZnO transparent ohmic contact layer was prepared by radio frequency magnetron sputtering with post-deposition annealing. The transmittance of the phosphorus doped ZnO exceeds 90% in the region of 440 nm to 500 nm. The specific contact resistance of the phosphorus doped ZnO on p-GaN was determined to be $7.82{\times}10^{-3}{\Omega}{\cdot}cm^2$ after annealing at $700^{\circ}C$. GaN LED chips with dimensions of $300\times300{\mu}m$ fabricated with the phosphorus doped ZnO transparent ohmic contact were developed and produced a 2.7 V increase in forward voltage under a nominal forward current of 20 mA compared to GaN LED with Ni/Au Ohmic contact. However, the output power increased by 25% at the injection current of 20 mA compared to GaN LED with the Ni/Au contact scheme.

Enhancement of the Corrosion Resistance of CrN Film Deposited by Inductively Coupled Plasma Magnetron Sputtering

  • Chun, Sung-Yong;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • 제20권3호
    • /
    • pp.112-117
    • /
    • 2021
  • Inductively coupled plasma magnetron sputtering (ICPMS) has the advantage of being able to dramatically improve coating properties by increasing the plasma ionization rate and the ion bombardment effect during deposition. Thus, this paper presents the comparative results of CrN films deposited by direct current magnetron sputtering (dcMS) and ICPMS systems. The structure, microstructure, and mechanical and corrosive properties of the CrN coatings were investigated by X-ray diffractometry, scanning electron microscopy, nanoindentation, and corrosion-resistance measurements. The as-deposited CrN films by ICPMS grew preferentially on a 200 plane compared to dcMS on a 111 plane. As a result, the films deposited by ICPMS had a very compact microstructure with high hardness. The nanoindentation hardness reached 19.8 GPa, and 13.5 GPa by dcMS. The corrosion current density of CrN film prepared by ICPMS was about 9.8 × 10-6 mA/cm2, which was 1/470 of 4.6 × 10-3 mA/cm2, the corrosion current density of CrN film prepared by dcMS.

[$Ca^{2+}-activated\;Cl^-$ Current in Gastric Antral Myocytes

  • Lee, Moo-Yeol;Bang, Hyo-Weon;Uhm, Dae-Yong;Rhee, Sang-Don
    • The Korean Journal of Physiology
    • /
    • 제28권2호
    • /
    • pp.143-150
    • /
    • 1994
  • The whole-cell mode of the patch clamp technique was used to study $Ca^{2+}-activated\;Cl^-\;current$ $(I_{Cl_{Ca}})$ in gastric antral myocytes. Extracellular application of caffeine evoked $Ca^{2+}-activated\;current$. In order to isolate the chloride current from background current, all known systems were blocked with specific blockers. The current-voltage relationship of caffeine-induced current showed outward rectification and it reversed at around $E_{Cl^-}$. The shift of reversal potential upon the alteration of external and internal chloride concentrations was well fitted with results which were calculated by the Nernst equation. Extracellular addition of N-phenylanthranilic acid and niflumic acid which are known anion channel blockers abolished the caffeine induced current. Intracellular application of a high concentration of EGTA also abolished this current. Application of c-AMP, c-GMP, heparin, or $AIF^-_4$ made no remarkable changes to this current. Sodium replacement with the impermeable cation N-methylglucamine or with $Cd^{2+}$ rarely affected this current. From the above results it is suggested that the caffeine induced current was a $Cl^-$ current and it was activated by intracellular $Ca^{2+}$.

  • PDF

열화상 분석을 통한 바리스터의 직렬과 병렬 조합의 안전성 평가 (Stability Evaluation of Series and Parallel Varistor Combination Using Thermal Image Analysis)

  • 엄주홍;조성철;이태형;한후석
    • 조명전기설비학회논문지
    • /
    • 제20권8호
    • /
    • pp.22-29
    • /
    • 2006
  • IEC 규격을 기반으로 최근에 개정된 KS 규격에 따라 등전위 접지시스템이 중요하게 자리매김 하였으며, 전원시스템의 안정성을 위해 서지보호소자의 사용이 급격히 증가하고 있다. 내재된 비선형 저항성분으로 뛰어난 V-I 특성을 가지는 $Z_nO$ 바리스터는 서지전압을 제한하여 서지전류로 환류시키기 위해 전원용 보호기로 주로 사용되고 있다. 이러한 $Z_nO$ 바리스터는 교류 전원선에 접속하기 위해서 몇 가지 회로조합 형태로 구성되어 사용되는데, 사용자는 바리스터를 직렬 혹은 병렬로 조합하여 사용함에 있어서 안전에 직접적으로 관련된 기능이나 열적 안정성을 포함한 많은 것들을 고려하여야 한다. 본 논문에서는 40[kA]의 전류용량을 가지는 단일 바리스터 소자와 직렬 혹은 병렬 회로조합의 바리스터에 대하여 잔류전압, 방전전류, 누설전류, 표면온도를 측정하여 각각의 조합형태에 따라 안정성을 비교하였다.

외상성 말초신경 손상으로 인한 창상 치유 지연 및 근위축이 유발된 소동물에서의 미세전류 자극 효능 평가 (The Effect of Micro-current Electrical Therapy on Muscle Atrophy and Delayed Wound Healing Process Induced Rat Caused by Traumatic Peripheral Nerve Injury)

  • 이한아;김서현;황동현;유리;유지희;김민주;조승관;김한성
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권1호
    • /
    • pp.1-9
    • /
    • 2018
  • This study was carried out to evaluate the effect of micro-current therapy on muscle atrophy and delayed wound healing process caused by traumatic peripheral nerve injury. For this, twenty-five 5-week-old Sprague Dawley rat were used and assigned to five groups including the normal group (NOR, n=5), the wound group (WD, n=5), the wounded and treated with micro-current electrical therapy group (WD+MET, n=5), the sciatic nerve denervated and wounded group (WD+DN, n=5), and the sciatic nerve denervated, wounded and treated with micro-current electrical therapy group (WD+DN+MET, n=5). In order to assess the changes in length of incisional wound for 12 days and the muscle volume for 2 weeks, the ImageJ analysis of macroscopic analysis and micro-CT data were obtained and analyzed. As a result, significant delay in the process in wound healing were observed and micro-current therapy suppress the postponement of healing process. Furthermore, there were significant changes in muscle volume between electrically treated group and non-treated group. These result shows that electrical stimulation may improve the delayed healing process and muscle atrophy at once.

반도체 검출기의 절연 최적화를 위한 다층 절연막 평가

  • 박정은;명주연;김대국;김진선;신정욱;강상식;남상희
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.372-372
    • /
    • 2014
  • 반도체 검출기는 입사되는 X선 에너지에 의하여 이온화되어 발생하는 전자 전공쌍을 수집함으로 방사선 정보를 확인하는 선량계로써 많은 연구와 활용이 이루어지고 있다. 하지만, X선 에너지에 의하여 반도체 검출기에서 발생하는 전기적 신호량이 높지 않기 때문에 누설 전류의 저감이 필수적이다. 누설 전류를 저감시키기 위한 방안으로 반도체 층과 전극 층의 Schottky Contact 구조의 설계, Insulating Layer의 사용, 높은 비저항의 반도체 물질 연구 등이 이루어지고 있다. 하지만, 기존에 누설 전류 저감을 위하여 Insulating Layer를 전극층과 반도체 층 사이에 형성하는 연구에 있어서 Insulating Layer와 반도체 층의 계면 사이에서 발생하는 Charge Trapping으로 인하여 생성되는 신호의 Reproducibility 저하, 동영상 적용의 제한 등의 문제점을 겪어왔다. 이에 본 논문에서는 누설 전류를 저감시킴과 동시에 Charge Trapping의 최소화를 이루기 위하여 Insulating Layer의 두께 최적화 연구를 수행하였다. 본 연구에서 사용한 Insulating Layer는 검출기 표면에 입사하는 X선 정보 손실을 최소화 시키는 동시에 누설 전류와 Charge Trapping을 최소화 시키는 방법으로써 CVD방법으로 검출기 표면에 균일하게 Insulating Layer를 코팅하였다. Insulating 물질은 Parylene을 사용하였으며, 그 중 온도, 습도 등 외부환경에 영향을 적게 받는 type C를 사용하였다. 증착에 사용한 장비의 진공도는 Torr로 설정하여 증착되는 Parylene의 두께가 약 $0.3{\mu}m$가 되게 하였으며, 실험에는 반도체 물질 PbO를 사용하였다. Parylene의 절연 특성은 Dark Current와 Sensitivity를 측정한 SNR을 이용하여 Parylene코팅이 되지 않은 동일 반도체 검출기와의 신호를 비교하였으며 또한 Parylene를 다층 제작한 검출기의 수집 신호량을 비교하였다. 제작한 검출기의 X선 조사 시의 수집 전하량 측정 결과, 100 kVp, 100mA, 0.03s의 X선 조건에서 $1V/{\mu}m$의 기준 시, Parylene를 코팅하지 않은 PbO 검출기의 Dark current는 0.0501 nA/cm2, Sensitivity는 0.6422 nC/mR-cm2, SNR은 12.184이었으며, Parylene단층의 두께인 $0.3{\mu}m$로 증착된 시편의 Dark current는 0.04097 nA/cm2, Sensitivity는 0.53732 nC/mR-cm2으로 Dark current가 감소되고 sensitivity도 감소하였지만 SNR은 13.1150으로 높아진 것을 확인할 수 있었다. Perylene이 $0.6{\mu}m$로 증착된 시편의 경우, Dark Current는 0.04064 nA/cm2, Sensitivity는 0.31473 nC/mR-cm2, SNR은 7.7443으로써 Insulating Layer가 없는 시편보다 SNR이 약 40% 낮아진 것을 확인할 수 있었다. Parylene이 $0.9{\mu}m$로 증착된 시편의 경우 Dark current는 0.0378 nA/cm2, Sensitivity 0.0461 nC/mR-cm2로 Insulating Layer가 없는 시편에 비해 SNR은 약 1/12배 감소한 1.2196이었고, Parylene이 $1.2{\mu}m$로 증착된 시편의 SNR은 1.1252로서 더 감소하였다. 따라서 Parylene을 다층 코팅한 검출기일수록 절연 효과의 영향이 커짐으로써 SNR 비교 시 수집되는 신호량이 줄어드는 것을 확인하였다. 반도체 검출기의 누설 전류를 저감시킴과 동시에 신호 수집율에 영향을 최소화시키기 위하여 Insulating Layer의 두께를 적절하게 설정하여 적용하면 Insulating Layer가 없는 검출기에 비해 누설전류를 최소한으로 줄일 수 있고 신호 검출효율이 감소하는 것을 방지할 수 있을 것이라 사료된다.

  • PDF