• Title/Summary/Keyword: N release rate

Search Result 245, Processing Time 0.026 seconds

Controlled Release of Oxyfluorfen from the Variously Complexed Formulations - II. Selection of Promising Formulations (수종(數種) 결합제형(結合劑型)으로부터 Oxyfluorfen의 방출제어(放出制御) 연구(硏究) - II. 유용(有用)한 방출제어형(放出制御型의) 선발(選拔))

  • Guh, J.O.;Im, W.H.;Lim, K.P.;Cho, C.S.;Chung, I.W.
    • Korean Journal of Weed Science
    • /
    • v.10 no.3
    • /
    • pp.207-213
    • /
    • 1990
  • Thirty formulations of oxyfluorfen(2-chloro-2,2,2-trifluoro-p-toyl 3-ethoxy-4-nitrophenyl ether were manufactured by adsorption and substitation. Of them 16 formulations n-ere selected because they showed rekatuvely high activity and long durability in the bioassay with (Brassica campestris V.L.) Then, the formulations selected and 4 commercial formulations were tested using Monochoria in pots. As the result, the formulations of polyer 11, elvan 7/40, coal-slag 7/40, zeolite(A), and bentonite(A) were selected because they showed almost complete inhibition of Monochoria even up the 73 days after treatment.

  • PDF

Effects of Monensin Administation on Mammary Function in Late Lactating Crossbred Holstein Cattle

  • Thammacharoen, S.;Chanpongsang, S.;Chaiyabutr, N.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.12
    • /
    • pp.1712-1718
    • /
    • 2001
  • An experiment was carried out to study the effect of monensin administration on mammary functions in crossbred Holstein cattle. Fourteen non-pregnant late lactating crossbred Holstein cattle, approximately 270 days postpartum, were selected for the experiment. They were divided into two groups of 7 animals each. Seven animals in the treated group were given sodium monensin orally in a slow-release capsule. Animals in both control and treated groups were fed the similar diet to maintain milk production and body score at 2.5. Rice straw was fed as a source of dietary fiber throughout the experimental period. After monensin administration, a significant increase in the molar percent of ruminal propionate (p<0.05) and a significant decrease in the molar percent of ruminal acetate (p<0.05) were apparent in comparison to the pretreated period. The ratio of acetate to propionate concentration decreased significantly after monensin administration (p<0.05), while it was maintained at the similar level throughout the period of experiment in the control group. Monensin did not affect the molar percent of ruminal butyrate and valerate. The concentration of milk allantoin between the control group and monensin treated group was not different. An excretion rate of allantoin in milk decreased in animals treated with monensin (p<0.05). Mammary blood flow did not show significant difference between control and monensin treated groups. The plasma glucose concentration, arteriovenous concentration difference and mammary gland uptake of glucose remained constant in both groups. Milk yield of the later stage of lactation in the control group declined during lactation advance while a tendency to increase in the milk yield was apparent after 21 days monensin administration. Milk compositions for concentration of lactose, fat and protein in both control group and monensin treated group did not change throughout the experimental periods. From these results, it can be concluded that the action of monensin could affect the ruminal fermentation pattern. Monensin could not increase milk yield in the late lactating period.

The Relationship between the Distance and Kinematical Parameters of Javelin in Korean Male Javelin Throwers (한국 남자 창던지기 선수들의 창의 운동학적 요인과 기록과의 관계)

  • Kim, Woo-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.3
    • /
    • pp.217-227
    • /
    • 2014
  • The purpose of this study was to investigate the relationship between distance and factors of javelin in korean male's javelin throwing. To accomplish this purpose, the analyzed trail selected total 29 trails (subjects 9) recorded more than 65 m in the 93rd National Sports Festival. The Kwon3D 3.1 version was used to obtain the three dimensional coordinates about the top, grip, end of javelin. And the kinematic data such as projection factors and direction angle of javelin calculated using Matlab2009a program. The statical analysis on the records (n=29) were used to Pearson's product moment correlation coefficient. There was a statistically positive relationship between the records and horizontal velocity (r=.866, ${\rho}$<.01), height (r=.541, ${\rho}$ <.001), height rate (r=.373, ${\rho}$ <.05) and horizontal displacement of javelin (r=.749, ${\rho}$ <.01), but the medial/lateral velocity showed a negative relationship to r=-.663 (${\rho}$ <.01). The attack and yaw angle showed not a significant relationship between the records, but the medial-lateral tilt (E1:r =-.557 [p<.01)] E2:r=-.629 [${\rho}$<.01], E3:r=-.528 [${\rho}$ <.01]) and attitude angle (E2:r=-.629 [[${\rho}$<.01], E3:r=-.619 [${\rho}$ <.01]) of javelin showed a negative relationship between the records, as well as the projection angle of javelin (r=-.419, ${\rho}$ <.05) showed a negative relationship between the records.

Performance Prediction according to Equivalence Ratio Change in Simulated-EGR Compression Ignition Engine Containing CO2 (CO2를 포함한 Simulated-EGR 압축착화엔진에서 당량비 변화에 따른 성능 예측)

  • Suh, Hyun Kyu
    • Journal of ILASS-Korea
    • /
    • v.25 no.1
    • /
    • pp.21-26
    • /
    • 2020
  • The objective of this work is to numerically reveal the effect of equivalence ratio change on the simultaneous reduction of NOX and soot emissions from the simulated-EGR compression ignition engine containing CO2. An experiment was conducted by using a single-cylinder common-rail injection system engine, an intake control system, and exhaust emissions analyzers. The numerical analysis results were validated under the same experimental conditions. To investigate the effect of equivalence ratio by simulated-EGR containing CO2, the O2, N2, and CO2 mole fraction were changed in the initial air conditions to the cylinder. The results were analyzed in terms of peak cylinder pressure, indicated mean effective pressure, indicated specific nitrogen oxide, and indicated specific soot. It was revealed that ignition delay characteristics and heat release rate (ROHR) characteristics were not significantly different according to the equivalence ratio. However, as the equivalence ratio increased from 0.68 to 0.83, the maximum combustion pressure and IMEP decreased by about 6.5% and 9.4%, respectively. In the case of ISFC, as is well known, the trend is opposite of IMEP. In the case of ISNO, as the equivalence ratio increased, less NO was generated, and as the equivalence ratio increased by 0.05, the ISSoot value of about 10% increased.

Study on Water quality and Release Rate of Sediment in Gul-po Stream (굴포천 유역의 수질 및 퇴적물 용출 특성에 관한 연구)

  • Jung, Jae-Hoon;Ahn, Tae-Woong;Choi, I-Song;Oh, Jong-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.966-970
    • /
    • 2010
  • 본 연구의 대상지인 인천광역시, 부천시, 서울특별시, 김포시를 걸쳐서 흐르는 굴포천은 산업화와 도시화로 인한 생활하수 및 공장폐수의 유입, 느린 유속과 하천 복개 등과 같은 유입오염원과 하천 구조적 문제로 인하여 수질이 악화되어 왔다. 특히 하천변의 소규모 영세 공장, 중 상류에 형성된 대규모 공업단지, 지역개발에 따른 인구증가로 인한 생활하수 등은 굴포천의 주 오염원이다. 또한 직강화된 하도와 느린 유속 등 하천의 구조적인 문제점 등은 하천의 자정능력을 저하시키고 있어 현재 굴포천의 수질수준은 전국 최하위에 머물러 있다. 더욱이 입자상 오염물질의 퇴적으로 인하여 굴포천의 하상은 대부분 퇴적오니가 형성되어 있다. 이러한 퇴적오니는 다량의 유기 물질 및 중금속 등을 흡착하고 있고, 재용출에 의한 내부오염 가능성을 내포하고 있기 때문에 오염원이 제거된 후에도 계속적인 수질오염을 일으킬 수 있다(Alloway et al, 1988). 따라서 본 연구에서는 굴포천 본류 전 구간 및 유입지천에 대하여 수질 오염도와 오염부하량을 산정하였으며, 본류 하상 퇴적물의 오염도 및 퇴적물의 용출특성에 관한 조사를 수행하였다. 본 연구는 굴포천 본류 구간을 최상류(GP-1)부터 최하류(GP-7)구간까지 총 7개 구간으로 구분하여 실시하였으며 각 지점별 수질 및 퇴적물 오염도를 조사하였다. 또한 3개의 유입지천에 대하여 수질 오염도 및 오염부하량을 산정하였다. 굴포천 하상의 경우 최상류의 GP-1지점을 제외하고는 전 구간이 대부분 오염된 오니가 퇴적되어 있으며, 이러한 퇴적오니의 퇴적물 오염도를 분석해본 결과 상류부인 GP-1, GP-2와 유속이 비교적 빠른 GP-7지점에 비하여 나머지 지점들의 오염도가 매우 높은 것으로 나타났다. 이러한 하상퇴적물의 영양염류 용출특성을 알아보기 위하여 호기 및 혐기조건에서 용출실험을 실시한 결과 호기와 혐기 조건에서 T-N은 각각 34.84 $mg/m^2/day$, 66.93 $mg/m^2/day$의 용출속도를 보였고, T-P의 경우 호기 조건 시 5.33 $mg/m^2/day$, 혐기 조건 시 6.84 $mg/m^2/day$의 용출속도를 보임으로서 퇴적물 용출에 의한 내부오염의 가능성이 있음을 보였다.

  • PDF

Analysis of Organic Matter and Nutrient Leaching Characteristics of Agricultural Land Soils in Reservoir Area (저수구역 경작지 토양의 유기물 및 영양염류 용출특성 분석)

  • Yu, Nayeong;Shin, Minhwan;Lim, Jungha;Kum, Donghyuk;Nam, Changdong;Lim, Kyoungjae;Kim, Jonggun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.1
    • /
    • pp.89-102
    • /
    • 2021
  • Soils in agricultural lands contain large amount of organic matter and nutrients due to the injected fertilizers and manure. During heavy rain, surface water and base runoff pollutants flows into a nearby stream or lake with eroded soil from agricultural lands. On the other hands, agricultural lands near the lake are inundated due to the increase of the water level in the lake, leading to organic matter and nutrient release from the inundated soil. In this study, releasing rates of nutrient salts and organic substances were analyzed for the soil in the agricultural land, where cultivation activities has been carried out and periodically flooded, to account for the possibility of contamination from the inundated agricultural land in reservoir areas The experiment results have shown that COD was released from the soil in anaerobic conditions, and T-P was released in both anaerobic and aerobic conditions. However, in the case of T-N, it was found that the runoff by soil was not made before the rainfall occurred, and when the soil was impound due to rainfall, the elution occurred under the aerobic conditions. Through the results of this study, it was possible to account for the effect of flooded agricultural lands on the water quality in the lake, and this could be reflected in an efficient agricultural non-point pollution management policy. In order to determine the precise releasing rate for each agricultural land, it is believed that the leaching experiment for paddy fields and grasslands are needed.

Nitrification of the Soil Applied Urea for Winter Barley as Basal Dressing and Following Nitrate Release to the Environment (추파대맥(秋播大麥) 재배시 기비(基肥)로 시용(施用)한 요소(尿素)의 질산화(窒酸化)및 그에 따른 질산태질소(窒酸態窒素)의 환경(環境)에의 방출(放出))

  • Kim, Sok-Dong;Soh, Chang-Ho;Kwon, Yong-Woong;Lim, Ung-Kyu
    • Korean Journal of Environmental Agriculture
    • /
    • v.12 no.2
    • /
    • pp.112-120
    • /
    • 1993
  • The use of fertilizer N is essential for maximum economic yield of crops. Meanwhile, enrichment of $NO_3^-$in the environment has to be avoided. Winter barley crop has a short duration of growth before winter, but is used to receive N greater than 60 kg/ha at seeding. Experiments were performed to determine the quantitative aspect of the fate of soil applied urea N among the residual, leached, and uptaken by winter barley (cv. Olbori), and to evaluate the effect of soil temperature on nitrification. Four levels of urea (0, 40, 80, and 120 kg N/ha) was basal-dressed to Olbori. $NH_4^+$ appeared dominant in the soil until 40 days after seeding, whereas $NO_3^-$ did thereafter. Nitrification rate at $5^{\circ}C$ of soil temperature was 40 to 50% of that at $15^{\circ}C. Linear increases in the number of ammonia oxidizing and nitrite oxidizing bacteria of the soil was present as the level of urea fertilization was higher. Less than 60% of N applied at seeding was uptaken by winter barley until mid-March but 50% was lost from death of older barley leaves during overwintering. Thereby only 10% of the applied N remained in the barley in spring. Only 15% of the applied N was present in the rhizosphere. The 17 to 20% of the soil applied N leached out as $NO_3^-$ the rhizosphere. Nitrogen leaching during winter was estimated to be 16 and 20 kg/ha when the basal application level of urea fertilization was 80 and 120 kg/ha, respectively.

  • PDF

Effect of xylazine hydrochloride on histamine release (Xylazine이 histamine 유리에 미치는 영향)

  • 김영환;박준형
    • Korean Journal of Veterinary Service
    • /
    • v.25 no.1
    • /
    • pp.53-73
    • /
    • 2002
  • It has been reported that degranulation of mast cells in rats, rabbits and dog was observed after dosing xylazine hydrochloride(Xh) which has been widely used as sedative, analgesic and muscular relaxant. Therefore, this experiment was conducted to examine the relations between Xh and histamine release and to identify the action of ${\alpha}$-adrenoceptors which exists on the suface of mast cells. 1. The content of histamine within serum was measured with HPLC by performing the O-phthalaldehyde(OPA) fluorescent derivation. The pretreatment method had a little modification from the conventional method. The pretreament was carried out in the following method. 0.2$m\ell$ of serum and 1$m\ell$ of butanol were added to mixed together and then the liquid was centrifugally separated at 4$^{\circ}C$ and 2,000 rpm for 3 minutes. 0.4$m\ell$ of 0.1N HCl and 1.6$m\ell$ of heptane were added to 0.8$m\ell$ of supernatant taken from the liquid, and they were mixed together. This mixture was also centrifugally separated at 4$^{\circ}C$ and 2,000 rpm for 5 minutes. The supernatant was thrown away and the OPA fluorescent derivation was carried out with 0.2$m\ell$ of the lower liquid then, 5 minutes after mixing 400${\mu}\ell$ of 0.1N HCl, 120${\mu}\ell$ of 1N NaOH and 40${\mu}\ell$ of 0.1% OPA in the 0.2$m\ell$ of the lower liquid,120${\mu}\ell$ of 3.57N H$_3$PO$_4$ was added to the mixed liquid, and the liquid, was mixed again and syringe-filtered. Then, the measurement was done with HPLC in the 30 : 70(ν/ν) ratio of 0.004M KH$_2$PO$_4$: CH$_3$CN, flow rate of 1.0$m\ell$/min., and a wavelength of λex= 350nm and λem=444nm at the column temperature of 27$^{\circ}C$, using the fluorescence detector. 2. The content of histamine in each laboratory animal appeared to be higher in such an order as rabbit, rat, guinea pig, dog, Korean indigenous goat, swine, Korean indigenous cattle, Holstein, and mouse, of which the individual mean values${\pm}$standard deviation were 2.0668 ${\pm}$ 0.6049. 0.4999 ${\pm}$ 0.2278, 0.4241 ${\pm}$ 0.1974, 0.1054 ${\pm}$ 0.0556, 0.1028 ${\pm}$ 0.0276, 0.0972 ${\pm}$ 0.0513, 0.0872 ${\pm}$ 0.0373, 0.0717 ${\pm}$ 0.0379, and 0.0706 ${\pm}$ 0.0366, respectively. 3. The content of histamine was measured at the moments of 15-, 30-, 60-, 120-minutes after inoamuscular injection of 20mg/100kg Xh into two to 4 years old Holstein weighing 600∼700kg. The result showed that there was a significant increase at the times of 30- and 90-minutes after injection(p<0.05). 4. Intramuscular injection of 3mg/10kg Xh was given to crossbred pug dogs weighing 2.5∼4.3kg. The content of histamine was measured at the times of 30-, 60-, 90- and 120-minutes after injection. The result revealed that there was a significant increase at the times of 60-and 90-minutes after injection(p<0.05). 5. Intramuscular injection of 10mg/$m\ell$∼25mg/$m\ell$ Xh in concentration of 0.1$m\ell$ was applied to Korean indigenous goat over 5 months old. Then, the content of histamine was measured at the times of 15-, 30-, 60- and 90-minutes after injection. A significant increase was shown at the times of 30- and 60-minutes after injection(p<0.05). 6. The content of histamine was measured at the moments of 30- and 60-minutes after intramuscular injection of 0.1-0.2$m\ell$ Xh (20mg/$m\ell$) into male rabbits weighting 2.5-4kg. A significant increase was found at the moment of 60 minutes after injection(p<0.001). 7. After administering Xh to the mast cell taken from the abdominal cavity of mouse, the content of histamine was measured. The result showed that the higher the concentration, the more significantly the content of histamine was increased(p<0.05). 8. Compound 48/80 was administered in concentration of 5$\mu\textrm{g}$/$m\ell$ and 10$\mu\textrm{g}$/$m\ell$ to the mast cell picked from the abdominal cavity of mouse. The result showed that there was a significant increase in the content of histamine in case of the concentration of 10$\mu\textrm{g}$/$m\ell$(p<0.05). It was found to be about 10,000 to 500,000 times stronger than the Xh. 9. After premedication of 1mg/kg of yohimbine hydrochloride as ${\alpha}$$_2$-adrenergic antagonist to rabbits, the Xh was administered to them. The result was that the value of histamine within serum was decreased significantly(p<0.001). 10. After premeditation of 1mg/kg of prazosin hydrochloride as ${\alpha}$$_1$-adrenergic antagonist to rabbits, the Xh was administered to them. It was found that the value of histamine within serum was decreased significantly(p<0.005). 11, Prazosin hydrochloride and yohimbine hydrochloride as ${\alpha}$$_1$-adrenergic antagonist, respectively, and ${\alpha}$$_2$-adrenergic antagonist were administerd. In this case, the value of histamine within serum was decreased significantly(p<0.0001). As the results, when the Xh is administered to various kinds of animals, the amount of histamine release within serum is increased. In view of the results so far achieved, it is concluded that Xh acted on both a$_1$-adrenoreceptor and ${\alpha}$$_2$-adrenoreceptor induces the degranulation of mast cell.

A Nucleotide Exchange Factor, BAP, dissociated Protein-Molecular Chaperone Complex in vitro (In vitro에서 핵산치환인자 BAP이 단백질-분자 샤페론 복합체 해리에 미치는 영향)

  • Lee Myoung-Joo;Kim Dong-Eun;Lee Tae-Ho;Jeong Yong-Kee;Kim Young-Hee;Chung Kyung-Tae
    • Journal of Life Science
    • /
    • v.16 no.3 s.76
    • /
    • pp.409-414
    • /
    • 2006
  • Molecular chaperones and folding enzymes in the endoplasmic reticulum (ER) associate with the newly synthesized proteins to prevent their aggregation and help them fold and assemble correctly. Chaperone function of BiP, which is a Hsp70 homologue in ER, is controlled by the N-terminal ATPase domain. The ATPase activity of the ATPase domain is affected by regulatory factors. BAP was identified as a nucleotide exchange factor of BiP (Grp78), which exchanges ADP with ATP in the ATPase domain of BiP This study presents whether BAP can influence folding of a protein, immunoglobulin heavy chain that is bound to BiP tightly. We first examined which nucleotide of ADP and ATP affects on BAP binding to BiP The data showed that endogenous BAP of HEK293 cells prefers ADP for binding to BiP in vitro, suggesting that BAP first releases ADP from the ATPase domain in order to exchange with ATP. Immunoglobulin heavy chain, an unfolded protein substrate, was released from BiP in the presence of BAP but not in the presence of ERdj3, which is another regulatory factor for BiP accelerating the rate of ATP hydrolysis of BiP The ADP-releasing function of BAP was, therefore, believed to be responsible for immunoglobulin heavy chain release from BiP. Grp170, another Hsp70 homologue in ER, did not co-precipited with BAP from $[^{35}S]$-metabolic labeled HEK293 lysate containing both overexpressed Grp170 and BAP. These data suggested that BAP has no specificity to Grp170 although the ATPase domains of Grp170 and BiP are homologous each other.

Experimental Study on the Designed Ventilation System Performance at Rescue Station in Tunnel Fire (터널 내 화재발생시 구난역 내의 설계된 환기 시스템 성능에 대한 실험적 연구)

  • Kim, Dong-Woon;Lee, Seong-Hyeok;Ryou, Hong-Sun;Yoon, Sung-Wook
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • In this study, the l/35 reduced-scale model experiment were conducted to investigate designed ventilation system performance at rescue station in tunnel fire. A model tunnel with 2 mm thick of steel, 10 m long, 0.19 m high and 0.26m was made by using Froude number scaling law. The cross-passages installing escape door at the center. were connected between accident tunnel and rescue tunnel. The n-heptane pool fire, $4cm\times4cm$, with heat release rate 698.97W were used as fire source. The fire source was located in the center and portal of accident tunnel as Worst case.. An operating ventilation system extracted smoke amount of 0.015 cms. The smoke temperature and carbon monoxide. concentration in cross-passage were measured to verify designed ventilation system. The results showed that, in center fire case without ventilation in accident tunnel, smoke did not propagated to rescue station. In portal tire case, smoke spreaded to rescue station without ventilation. But smoke did not propagated to rescue station with designed ventilation.