• 제목/요약/키워드: N defect

검색결과 637건 처리시간 0.029초

6H-SiC wafer의 결정성 및 전기적 특성 (Crystallinity and electrical properties of 6H-SiC wafers)

  • 김화목;임창성;오근호
    • 한국결정성장학회지
    • /
    • 제7권3호
    • /
    • pp.393-399
    • /
    • 1997
  • 승화법에 의한 6H-SiC 단결정의 최적 성장조건을 설정하여 고품질의 6H-Sic 단결정을 성장하였다. 성장된 결정의 직경은 약 33 mm, 길이는 약 11 mm였다. 성장된 결정을 절단하여 연마한 후 광학현미경을 이용하여 연마된 SiC wafer의 micropipe density와 planar defect density를 측정한 결과, micropipe density는 400개/$ \textrm{cm}^2$이었고 planar defect density는 50개/$\textrm{cm}^2$이었다. 이 6H-SiC wafer와 기판으로 사용된 Acheson 결정의 결정성을 비교하기 위하여 Raman 분광법과 double crystal X-ray diffraction 분석법이 사용되었다. 이 분석에 의해 승화법에 의해 성장된 6H-SiC wafer가 Acheson seed보다 결정성이 우수하였다. Hall effect 측정법에 의해 불순물이 첨가되지 않은 6H-SiC wafer의 전기적인 특성을 측정하였으며 그 결과 캐리어 농도는 $3.91{\times}10^{15}/\textrm {cm}^3$이었고, n-type이었다.

  • PDF

Outcome of inflammatory response after normothermia during cardiopulmonary bypass surgery in infants with isolated ventricular septal defect

  • Kim, Dong Sub;Lee, Sang In;Lee, Sang Bum;Hyun, Myung Chul;Cho, Joon Yong;Lee, Young Ok
    • Clinical and Experimental Pediatrics
    • /
    • 제57권5호
    • /
    • pp.222-225
    • /
    • 2014
  • Purpose: A recent study analyzing several cytokines reported that long cardiopulmonary bypass (CPB) time and long aortic cross clamp (ACC) time were accompanied by enhanced postoperative inflammation, which contrasted with the modest influence of the degree of hypothermia. In this present study, we aimed to examine the effect of CPB temperature on the clinical outcome in infants undergoing repair of isolated ventricular septal defect (VSD). Methods: Of the 212 infants with isolated VSD who underwent open heart surgery (OHS) between January 2001 and December 2010, 43 infants were enrolled. They were classified into 2 groups: group 1, infants undergoing hypothermic CPB ($26^{\circ}C-28^{\circ}C$; n=19) and group 2, infants undergoing near-normothermic CPB ($34^{\circ}C-36^{\circ}C$; n=24). Results: The age at the time of the OHS, and number of infants aged<3 months showed no significant differences between the groups. The CPB time and ACC time in group 1 were longer than those in group 2 (88 minutes vs. 59 minutes, P =0.002, and 54 minutes vs. 37 minutes, P =0.006 respectively). The duration of postoperative mechanical ventilation was 1.6 days in group 1 and 1.8 days in group 2. None of the infants showed postoperative neurological and developmental abnormalities. Moreover, no postoperative differences in the white blood cell count and C-reactive protein levels were noted between two groups. Conclusion: This study revealed that hypothermic and near-normothermic CPB were associated with similar clinical outcomes and inflammatory reactions in neonates and infants treated for simple congenital heart disease.

Cranioplasty with the Porous Polyethylene Implant(Medpor) for Large Cranial Defect

  • Hong, Ki-Sun;Kang, Shin-Hyuk;Lee, Jang-Bo;Chung, Yong-Gu;Lee, Hoon-Kap;Chung, Heung-Seob
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권2호
    • /
    • pp.96-101
    • /
    • 2005
  • Objective : This paper describes our experience and implant technique for cranioplasty of a large cranial defects using a porous polyethylene implant[Medpor] and compares the results with polymethylmethacrylate[PMMA]. Methods : Sixteen cranioplasties were performed using Medpor[n= 10] and PMMA[n=6] implants between June 2003 and January 2005. The criterion for patient enrollment was a defect larger than 10cm in diameter. This study compared the operation times and complications. Results : The operation times ranged from 105 to 250minutes[Mean $180^{\circ}{\pm}44minutes$) in Medpor and from 185 to 460minutes [mean 128minutes] in PMMA. The absolute operation times were shorter using the Medpor implant and the differences were statistically significant[P=0.030]. Satisfactory cosmetic results were obtained in all cases using the Medpor implant and with no implant-related complications. Bone ingrowth to the medpor implant was presumed to be the result on an increase in Houndsfield units of the implant, particularly at the marginal areas in the serial follow-up brain computed tomography images. Conclusion : It is believed that the properties of a Medpor implant make this implant an good alternative to the existing methods of a cranial contour correction. However, a further follow-up study will be needed.

음향방출법을 이용한 굽힘피로 손상된 소켓용접배관의 진단 및 감시 (Diagnosis and Monitoring of Socket Welded Pipe Damaged by Bending Fatigue Using Acoustic Emission Technique)

  • 김정석;오세웅;박익근
    • 비파괴검사학회지
    • /
    • 제28권4호
    • /
    • pp.323-330
    • /
    • 2008
  • 소구경 배관 소켓 용접부의 고주기 피로특성윽 평가하고 피로 균열의 발생을 음향방출법을 이용하여 실시간 모니터링 하였다. 스테인리스 316L강 시험편은 가스텅스텐아크용접 공정으로 루트부에 결함이 없는 시험편과 용입불량 결함이 있는 시험편으로 준비하였다. 피로파단은 고응력 일때는 토우부, 상대적으로 저응력일 때는 루트부에서 일어났다. 피로시험동안 음향방출 카운트가 급격히 증가하는 시점을 균열의 발생 싸이클 ($N_i$)로 정의하였고 방사선투과법과 전자현미경을 이용하여 피로균열 생성 싸이클 전과 후에서 균열을 확인하였다. 소켓용접배관의 굽힘피로 손상 진단 및 감시를 위해 균열의 존재와 파괴모드 그리고 균열의 발생 싸이클에 관한 연구를 수행하였다.

Dentinal defects induced by 6 different endodontic files when used for oval root canals: an in vitro comparative study

  • Pawar, Ajinkya M;Thakur, Bhagyashree;Kfir, Anda;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제44권3호
    • /
    • pp.31.1-31.9
    • /
    • 2019
  • Objectives: To compare the formation of dentinal defects using stainless-steel hand K-files (HFs), rotary files, reciprocating files, and Self-Adjusting File (SAF), when used for oval root canals. Materials and Methods: One hundred and forty extracted human mandibular premolar with single root and oval canal were selected for this study. Oval canals were confirmed by exposing to mesio-distal and bucco-lingual radiographs. Teeth with open apices or anatomic irregularities were excluded. All selected teeth were de-coronated perpendicular to the long axis of the tooth, leaving roots segments approximately of 16 mm in length. Twenty teeth were left unprepared (control), and the remaining 120 teeth were divided into 6 groups (n = 20) and instrumented using HF (size 40/0.02), Revo-S (RS; size 40/0.06), ProTaper NEXT (PTN; size 40/0.06), WaveOne (WO; size 40/0.09), RECIPROC (RC; size 40/0.06), and the SAF (2 mm). Roots were then sectioned 3, 6, and 9 mm from the apex, and observed under stereomicroscope, for presence of dentinal defects. "No defect" was defined as root dentin that presented with no visible microcracks or fractures. "Defect" was defined by microcracks or fractures in the root dentin. Results: The control, HF, and SAF did not exhibit any dentinal defects. In roots instrumented by RS, PTN, WO, and RC files exhibited microcracks (incomplete or complete) in 40%, 30%, 55%, and 50%, respectively. Conclusions: The motor-driven root canal instrumentation with rotary and reciprocating files may create microcracks in radicular dentine, whereas the stainless-steel hand file instrumentation, and the SAF produce minimal or less cracks.

Decellularized Non-cross-linked Collagen Membranes for Guided Bone Regeneration in Rabbit Calvarial Defects

  • Jeon, Su-Hee;Lee, Da-Na;Seo, Young-Wook;Park, Jin-Young;Paik, Jeong-Won;Cha, Jae-Kook;Choi, Seong-Ho
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.51-60
    • /
    • 2022
  • Purpose: The aim of this study was to evaluate the bio-durability and bone regeneration capacity of the non-cross-linked collagen membrane in rabbit calvarial defect models. Materials and Methods: Four circular defects with 8 mm diameter were made in each of calvarium of 10 male rabbits. The following groups was randomly assigned to each defect - 1) Control, 2) membrane group containing non-cross-linked collagen membrane only (M), 3) bone graft group (B), 4) bone graft with membrane group (B+M). Animals were sacrificed and samples were harvested at 2 weeks (n=5) and 8 weeks (n=5). Histologic sections were prepared and histomorphometric analysis was performed. Result: Histologic results showed well adaptation of the non-cross-linked membrane on each defect and normal healing response at 2 weeks. At 8 weeks, the membranes were partially biodegraded. Histomorphometrically, B and B+M group showed the significantly greater total augmented area (B+M group, 10.44±1.49, P=0.016; B group, 9.13±0.53, P=0.032) and new bone formation (B+M group, 2.89±0.93, P=0.008; B group, 2.85±1.15, P=0.008) compared to control group. Collapsing of the central portion of the membrane, membrane group showed greater value in new bone formation at 8 weeks (1.78±0.68, P=0.032). Conclusion: Within the limitations of this study, the non-cross-linked collagen membrane fabricated using the improved decellularized method was shown to be effective for the regeneration of calvarial bone defects. In addition, prolonged barrier function might be provided using this collagen membrane.

Features Extraction and Mechanism Analysis of Partial Discharge Development under Protrusion Defect

  • Dong, Yu-Lin;Tang, Ju;Zeng, Fu-Ping;Liu, Min
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.344-354
    • /
    • 2015
  • In order to study the development of partial discharge (PD) under typical protrusion defects in gas-insulated switchgear, we applied step voltages on the defect and obtained the ${\varphi}-u$ and ${\varphi}-n$ spectrograms of ultra-high frequency (UHF) PD signals in various PD stages. Furthermore, we extracted seven kinds of features to characterize the degree of deterioration of insulation and analyzed their values, variation trends, and change rates. These characteristics were inconsistent with the development of PD. Hence, the differences of these features could describe the severity of PD. In addition, these characteristics could provide integrated characteristics regarding PD development and improve the reliability of PD severity assessment because these characteristics were extracted from different angles. To explain the variation laws of these seven kinds of parameters, we analyzed the relevant physical mechanism by considering the microphysical process of PD formation and development as well as the distortion effect generated by the space charges on the initial field. The relevant physical mechanism effectively allocated PD severity among these features for assessment, and the effectiveness and reliability of using these features to assess PD severity were proved by testing a large number of PD samples.

RF-Magnetron sputtering법을 이용한 ZnO buffer layer가 ZnO:(Al,P) 박막의 미세구조에 미치는 영향

  • 신승학;김종기;이준형;허영우;김정주
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.266.2-266.2
    • /
    • 2016
  • 최근 디스플레이 산업의 확대에 따라 투명 전도 산화물(Transparent Conducting Oxides:TCOs)의 수요가 급증하고 있다. 이 중 ZnO는 wide bandgap (3.37eV)와 large exciton binding energy (60meV)의 값을 가져 차세대 투명 전도 산화물, LED와 LD 등의 소자 소재로 각광받고 있다. ZnO는 electron을 내어놓는 native defect 때문에 기본적으로 n-type 물성을 띈다. 그래서 dopant를 이용해 p-type ZnO를 제작할 때 native defect를 줄이는 것이 중요한 요점이 된다. 이 때 buffer layer를 사용하여 native defect를 줄이는 방법이 사용되고 있다. 본연구에서는 RF-magnetron sputtering법을 이용하여 c-plane sapphire 기판 위에 다양한 조건의 ZnO buffer layer를 증착하고, 그 위에 ZnO:(Al,P) co-doping한 APZO를 증착하였다. ZnO buffer layer 증착조건의 변수는 증착온도와 Ar:O2의 비율을 변수로 두었다. 이러한 박막을 FE-SEM, XRD, Hall effect measurement, AFM을 통하여 미세구조와 물성을 관찰하였다. 이 때 APZO보다 낮은 증착온도에서 ZnO buffer layer가 증착되면 APZO를 증착하는 동안 chamber 내부에서 열처리하는 효과를 얻게 되고, UHV(Ultra High Vaccum)에서 열처리 될 때 ZnO buffer layer의 mophology와 결정성이 변하게 되는 모습을 관찰아혔다. 또한 본 실험을 통해 ZnO buffer layer의 증착 온도가 APZO의 증착온도보다 높을 때 제어 가능한 실험이 됨을 확인 할 수 있었다.

  • PDF

Automatic Detection of Texture-defects using Texture-periodicity and Jensen-Shannon Divergence

  • Asha, V.;Bhajantri, N.U.;Nagabhushan, P.
    • Journal of Information Processing Systems
    • /
    • 제8권2호
    • /
    • pp.359-374
    • /
    • 2012
  • In this paper, we propose a new machine vision algorithm for automatic defect detection on patterned textures with the help of texture-periodicity and the Jensen-Shannon Divergence, which is a symmetrized and smoothed version of the Kullback-Leibler Divergence. Input defective images are split into several blocks of the same size as the size of the periodic unit of the image. Based on histograms of the periodic blocks, Jensen-Shannon Divergence measures are calculated for each periodic block with respect to itself and all other periodic blocks and a dissimilarity matrix is obtained. This dissimilarity matrix is utilized to get a matrix of true-metrics, which is later subjected to Ward's hierarchical clustering to automatically identify defective and defect-free blocks. Results from experiments on real fabric images belonging to 3 major wallpaper groups, namely, pmm, p2, and p4m with defects, show that the proposed method is robust in finding fabric defects with a very high success rates without any human intervention.

전력케이블 절연재료의 내부결함에 따른 전기적 특성 (Electrical Characteristics due to Inner Defect of Insulating Materials for Power Cable.)

  • 최상기;김탁용;김왕곤;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.27-30
    • /
    • 2003
  • Recently, on power system, it is used to high voltage of transmission and distribution due to safe power supply and have high quality and insulation in order to satisfy excellent insulator. Thus, according to underground of high voltage cable, is occurred break down by ground short. Therefore, it is used to high quality XLPE power cable to interrupt instantaneous voltage drop. If it appear inner defect for cable whose have high quality and insulation, it is reduced rapidly due to concentration of electrical field. After assemble to manufacture, in order to inspect cable condition, it is decided much inspection standard. In this paper, In inner defect of assembling cable at manufacture, for measure the variation of insulation condition by void. it tested the variation of insulating characteristics, using $\phi$-q-n distribution variation in partial discharge experiment.

  • PDF