• 제목/요약/키워드: N and P Removal

검색결과 998건 처리시간 0.027초

인공하수 조성 성분에 따른 SBR 처리 공정의 효율에 관한 연구 (A Study on Efficiency of SBR Process by Composition of Artificially Wastewater)

  • 이장훈;장승철;권혁구;김동욱
    • 한국환경보건학회지
    • /
    • 제31권2호
    • /
    • pp.99-106
    • /
    • 2005
  • The removals of organic matter, nitrogen and phosphate in wastewater were investigated with Sequencing Batch Reactor (SBR). Glucose and sodium acetate were Used for organic carbon source so as to know nutrient removal efficiency in proportion to MLSS concentration. In the case of glucose, the COD removal rate was $74\%,\;41\%\;and\;66\%$ in MLSS 5000, 3000 and 1000, respectively. On equal terms, the BOD was $57\%,\;21\%\;and\;38\%$, the T-N was $24\%,\;13\%\;and\;44\%$, and the T-P was $12\%,\;21\%\;and\;33\%$. As a result, the removal rate of organic materials showed the finest remove when MLSS was 5000, but the nutrient removal rate appeared as was best when MLSS was 1000. In the case of sodium acetate, the COD removal rate was $83\%,\;81\%\;and\;86\%$ in MLSS 5000, 3000 and 1000, respectively. On equal terms, the BOD was appeared by $76\%,\;82\%\;and\;92\%$, the T-N $57\%,\;42\%\;and\;78\%$, and the T-P $48\%,\;52\%\;and\;38\%$. As a result, organic and T-N removal rates were best when MLSS was 1000. But, the T-P removal rates were best when MLSS was 3000. Glucose was shown fast removal in reaction beginning, but screened by more efficient thing though sodium acetate removes organic matter, nitrogen and phosphate. Form of floc was ideal in all reactors regardless of carbon source and MLSS concentration. And its diameter was about $200\~500{\mu}m$.

막결합 연속회분식 반응기를 이용한 농촌마을 하수의 고도처리 (Membrane-Coupled Sequencing Batch Reactor System for the Advanced Treatment of Rural Village Sewage)

  • 김승건;이호원
    • 멤브레인
    • /
    • 제24권1호
    • /
    • pp.20-30
    • /
    • 2014
  • C/N 비가 낮은 농촌마을 하수의 고도처리를 위하여 $0.4{\mu}m$의 세공크기를 갖고 있는 평막이 침지된 연속회분식 반응기를 사용하였다. 분말활성탄의 투입, 폭기량 및 유입 유기물 농도가 처리효율과 여과 성능에 미치는 영향을 조사하였다. 54일 이내의 조업 초기에서는 C/N 비가 증가할수록 COD, T-N 및 T-P의 제거율과 MLSS 농도는 증가하였다. 조업 89일 후의 COD, T-N 및 T-P의 제거율은 각각 97.1%, 75.0% 및 48.3%이었다. 막여과에 의해 처리수에서 SS는 검출되지 않았으며, T-P의 제거율이 낮게 나온 이유는 과잉의 슬러지를 배출하지 않았기 때문이다. 분말활성탄을 투여한 경우 조업이 진행됨에 따라 분말활성탄의 혼합강도와 충돌빈도가 증가하여 슬러지의 입자크기가 감소하였으며, 이로 인해 분말활성탄을 투여하지 않은 경우에 비해 TMP 상승이 크게 나타났다.

충전탑형 무산소/호기 공정에서 반송비에 따른 유기물 및 질소 제거 특성 (Characteristics of Organics and Nitrogen Removal with the Recycle Ratio in Anoxic / Oxic Packed Bed Process)

  • 선용호
    • 한국환경과학회지
    • /
    • 제11권12호
    • /
    • pp.1261-1265
    • /
    • 2002
  • This study was focused on the investigation of the characteristics of organics and nitrogen removal with the recycle ratio in anoxic/oxic(A/O) packed bed process that consisted of the anoxic reactor and the aerobic reactor. As increasing the recycle ratio by 0.5, 1.0, 2.0, the COD removal efficiency increased by 94.0%, 98.5%, 98.8% respectively. The aerobic reactor showed the perfect nitrification efficiency by 98.5%, 99.2%, 98.0% respectively. The T-N removal efficiency with the recycle ratio, increased by 56%, 67%, 70% respectively. As increasing the recycle ratio by 0.5, 1.0, 2.0, T-P removal efficiency decreased by 62.1%, 57.4%, 51.3% respectively. The process by releasing the stored phosphorus in the anoxic reactor and uptaking the excess phosphorus in the aerobic reactor, occurred well comparatively when recycle ratio is 0.5. But this process did not occur when the recycle ratio is 1.0 and 2.0. And optimum pH of nitrification was about 6~7 and alkalinity decreased as nitrification rate increased. As increasing the recycle ratio in the anoxic reactor, DO concentration and ORP increased.

부처꽃, 물상추, 미나리, 달뿌리풀의 수질정화효과에 관한 연구 (A study on the effect of the water purification by Lythrum anceps, Pistia straiotes, Oenanthe javanica, and Phragmites japonica)

  • 조해용
    • 한국산학기술학회논문지
    • /
    • 제8권2호
    • /
    • pp.380-384
    • /
    • 2007
  • COD 제거효율은 각 조의 부처꽃을 제외한 대조군의 경우 물상추 56%, 달뿌리풀 48%, 미나리 41%의 효율을 보이고, 발포유리가 첨가된 조의 경우는 물상추 69%, 달뿌리풀 68% 미나리 62%의 제거효율을 보임으로써 발포유리를 첨가한 조의 COD 제거효율이 대조군 보다 높았다. T-N의 제거효율은 발포유리를 첨가한 조의 경우 부처꽃 91%, 달뿌리풀 93%와 발포유리를 첨가한 혼합조가 94%의 높은 T-N 제거효율 보임으로써 모든 질소성분이 제거된 것으로 사료된다. T-P의 제거효율은 대조군의 부처꽃 35%, 달뿌리풀 8%이며, 발포유리를 첨가한 조의 부처꽃 78%, 달뿌리풀 43%로 발포유리를 첨가한조의 T-P 제거효율이 대조군 보다 높았다.

  • PDF

Investigation on Trend Removal in Time Domain Analysis of Electrochemical Noise Data Using Polynomial Fitting and Moving Average Removal Methods

  • Havashinejadian, E.;Danaee, I.;Eskandari, H.;Nikmanesh, S.
    • Journal of Electrochemical Science and Technology
    • /
    • 제8권2호
    • /
    • pp.115-123
    • /
    • 2017
  • Electrochemical noise signals in many cases exhibit a DC drift that should be removed prior to further data analysis. Polynomial fitting and moving average removal method have been used to remove trends of electrochemical noise (EN) in time domain. The corrosion inhibition of synthesized schiff base N,N'-bis(3,5-dihydroxyacetophenone)-2,2-dimethylpropandiimine on API-5L-X70 steel in hydrochloric acid solutions were used to study the effects of drifts removal methods on noise resistance calculation. Also, electrochemical impedance spectroscopy (EIS) was used to study the corrosion inhibition property of the inhibitor. The results showed that for the calculation of $R_n$, both methods were effective in trend removal and the polynomial with m=4 and MAR with p=40 were in agreement.

Fundamental Structure in Simultaneous Removal for Phytoplankton and Nutrient Salt in Lakes

  • SEKI, Tatsuhiro;ISHII, Yuuichi;ISHII, Toshio;TAKI, Kazuo
    • Environmental Engineering Research
    • /
    • 제14권4호
    • /
    • pp.220-225
    • /
    • 2009
  • The water quality in eutrophic lakes is affected by serious problems, such as abnormal increasing of Cyanobacteria. The purpose of this study was to investigate the possibility of a modified flotation system using a hybrid technique formed by chemical compounds and an electrostatic bridge. Therefore, experiments using the hybrid technique were performed to measure the zeta potential value on the phytoplankton surface and the removal efficiencies of phytoplankton, ammonia nitrogen, nitrate nitrogen and phosphoric acid. The results were as follows: Firstly, the zeta potential of M.aeruginosa was observed to approach charge neutralization due to adhesion of magnesium hydroxide precipitate on the phytoplankton surface in the pH range 10.5 to 11. Secondly, the concentration of chlorophyll-a decreased from about 150 to 20${\mu}g$g/L, with a maximum removal efficiency of 84% due to coagulation with pH values higher than 10. Thirdly, the N$H_4$-N concentration was observed to decrease from 0.62 to 0.54mg-N/L (13%), and the P$O_4$-P concentration, which is a limiting factor to the formation of algae blooms, decreased from 0.27 to 0.02mg-P/L (92%). These findings suggest that the modified flotation system can be applied for the purification of the raw water of numerous lakes containing high phytoplankton populations and elevated pH.

수직 흐름 제올라이트 갈대 여과상의 간헐적 주입에 의한 인공하수 처리 (Vertical Flow Zeolite-Filled Reed Bed for Treatment of Artificial Sewage with Intermittent Feeding)

  • 서정윤;김태형;최민수
    • KSBB Journal
    • /
    • 제18권2호
    • /
    • pp.140-144
    • /
    • 2003
  • 제올라이트로 충진된 수직 흐름 갈대 여과상에 인공하수를 주입하면서 처리효율을 조사하였다. 여과상 표면적 $m^2$당 1일 314 L의 인공하수가 6시간마다 10분 동안 간헐적으로 주입되었다 각 항목별 연중 평균 처리효율은 CO $D_{Cr}$ , 95.1%, T-N 49.5%, N $H_4$$^{+}$-N 99.4%, T-P 56.4%이었다. T-N의 처리효율은 가동 시간이 경과함에 따라 현저하게 감소하였다. 여과상의 상층에서 많은 인이 흡착되었으며 흡착된 인 중 대부분은 Fe-p, Ca-P와 환원가용성 Fe-P이었다.

폐수내 질소 및 인 제거를 위한 struvite 결정화 최적조건 도출 (Estimation of the Optimum Factor of the Struvite Crystalization for the Nitrogen and Phosphorus Removal in WWTP)

  • 김지연;문용택;서인석;김병군
    • 상하수도학회지
    • /
    • 제21권6호
    • /
    • pp.745-753
    • /
    • 2007
  • By struvite and hydroxyapatite crystallization, was high concentration of nitrogen and phosphorus in wastewater simultaneously. Particularly, removal of nitrogen and phosphate for crystallization have been applied to landfill leachates and animal wastewater. The purpose of this study is to decide the optimum struvite crystallization factors, sequence of $Mg^{2+}$ addition, pH control and the molar ratio of $Mg^{2+}$ over $PO_4^{3-}$. In conclusion, dosage of the magnesium followed by pH control formed magnesium hydroxide, so pH was decreased. Therefore, pH adjustment should followed by after magnesium dosage and then pH should be adjusted to 11. Over pH 10, it was not good for struvite crystallization efficiency by side reaction. Following of the $Mg^{2+}$ and the $PO_4^{3-}$ are dosed excessively, the removal efficiency of the $NH_4^+$ increased. A molar ratio of $Mg^{2+}:NH_4^+:PO_4^{3-}$, 1.3:1:1.3 was the most on effective for $NH_4^+$ removal at pH 9.5. But for the perfect removal $NH_4^+$, it is thought to be that molar ratio should be 2:1:2.

빛의 조사기간으로 본 호기성 고율 안정조 프로세스의 영양물질 제거 (The Nutrients Removal in Aerobic High Rate Ponds Through the Lighting Period)

  • 공석기
    • 환경위생공학
    • /
    • 제11권1호
    • /
    • pp.83-91
    • /
    • 1996
  • It is not too much to say that the territorial inhabitants' concerns are wholly c concentrated on the environmental preservation-problem and development-problem in Korea given effect to the local self-government system. At a time like this I was studied the effect on nutrients removal through lighting period in aerobic high rate pond and we know that waste stabilization pond method is the most economical and energy saving wastewater treatment technology than others. At the results which was studied through operating the reactor-l artifically main-tained at a temperature, $25^{\circ}C$, a light intensity, 3000lux, and a lighting period, 24hrs and the reactor-2 artifically maintained at a tern야rature, $25^{\circ}C$ and a light intensity 3000lux, and a lighting period period, 12hrs, It has appeared for 24hrs.-lighting period -reactor-1 to be prior to the reactor-2. The attained results are that 1. reactor-1 is prior to reactor-2 on oxygen-generation 2. reactor-1 is prior to reactor-2 on algal production 3. COD removal efficiency, 90.76%, T-N removal efficiency, 80%, T-P removal e efficiency, 74.47 % in reactor-2, in reactor-1 COD removal efficiency, 94.85 %, T-N removal efficiency, 98.07%, T-P removal efficiency, 72.13% are, so the treatment efficiency of reactor-1 is more excellent than things of reactor-2 4. it appeared that the detention time is 8, 9days.

  • PDF

生物膜 電極反應機를 이용한 廚房廢水 처리 효과 (Effects of Domestic Wastewater Treatment used Biofilm-Electrode Reactor(BER))

  • Noh, Hyun-Woong;Yoon, Oh-Sub
    • 한국환경보건학회지
    • /
    • 제23권1호
    • /
    • pp.43-49
    • /
    • 1997
  • This study was aimed to estimate removal efficiency(%) of BER(Biofilm-Electrode Reactor) and A.S(Activated Sludge) treatments. When were analyzed COD$_{Cr}$, NH$_3$-N and T-P by current density and reaction time, the results were as follows : 1) In BER treatment, the removal efficiency of COD$_{Cr}$ in domestic wastewater was 79-86% when current density was 2.39 mA/dm$2$(15mA)-3.98 mA/dm$^2$(25mA) and reaction time was 48 hr. 2) Removal efficiency of NH$_3$-N was 71-73% when current density was 2.39-3.98 mA/dm$^2$ and reaction time 48 hr. 3) When the reaction time was 48 hr removal efficiency(%) of BER treatment for COD$_{Cr}$, NH$_3$-N and T-P were more excellent than A.S. treatment. And then we prospect that was because activated microorganism colonies attached in biofilm on surface of electrode pannel. Therefore, In order to derive BER treatment efficiency(%) should establish optimum conditions of pH, temp., reaction time, current density and biochemical and electrochemical states.

  • PDF