• 제목/요약/키워드: Myoelectric hand prosthesis

검색결과 19건 처리시간 0.027초

Development of Surface Myoelectric Sensor for Myoelectric Hand Prosthesis

  • Choi, Gi-Won;Moon, In-Hyuk;Sung, So-Young;Lee, Mynug-Joon;Chu, Jun-Uk;Mun, Mu-Seong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1268-1271
    • /
    • 2005
  • This paper proposes a compact-sized surface myoelectric sensor for myoelectric hand prosthesis. To fit the surface myoelectric sensor in the socket of the myoelectric hand prosthesis, the sensor should be a compact size. The surface myoelectric sensor is composed of a skin interface and a single processing circuit that are mounted on a single package. Since the skin interface has one reference and two input electrodes, and the reference electrode is located in middle of two input electrodes, we propose two types of sensors with the circle- and bar-shaped reference electrode, but all input electrodes are the bar-shaped. The metal material used for the electrodes is the stainless steel (SUS440) that endures sweat and wet conditions. Considering conduction velocity and median frequency of the myoelectric signal, we select the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22 mm. The signal processing circuit consists of a differential amplifier with band pass filter, a band rejection filter for rejecting 60Hz power-line noise, amplifiers, and a mean absolute value circuit. We evaluate the proposed sensor from the output characteristics according to the IED and the shape of the reference electrode. From the experimental results we show the surface myoelectric sensor with the 18mm IED and the bar-shaped reference electrode is suitable for the myoelectric hand prosthesis.

  • PDF

근전의수의 성능시험방법에 대한 연구 (Study on a test method for the performance of myoelectric hand prosthesis)

  • 최기원;최규하;신우석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.265-266
    • /
    • 2010
  • This paper propose the test method for performance of myoelectric hand prosthesis(MHP) according to myoelectric signal generated in the human muscle. The MHP consists of a mechanical hand, a surface myoelectric sensor(SMES) for measuring myoelectric signal, a control system and a charging battery. The propose test method is proved the reliability of MHP.

  • PDF

근전의수의 내구성 시험방법에 대한 연구 (Study on a test method for the endurance of myoelectric hand prosthesis)

  • 최기원;문무성
    • 재활복지공학회논문지
    • /
    • 제5권1호
    • /
    • pp.11-15
    • /
    • 2011
  • 본 논문은 사함의 근육에서 발생하는 근전위 신호에 의해서 제어되는 근전의수의 성능에 대한 시험방법을 제안한 것이다. 근전의수는 기계적인 의수, 근전위 신호를 측정하는 표면 근전위 센서, 제어시스템, 그리고 충전용 배터리로 구성되어 있다. 상용화 된 근전의수를 가지고 파지 내구성을 시험한 결과 소음과 파지력은 큰 차이가 없었다. 제안된 시험방법은 내구성 시험을 통하여 근전의수의 신뢰성을 검증하였다.

근전의수의 제어시스템에 관한 연구 (A Study on the Control System of Myoelectric Hand Prosthesis)

  • 최기원;추준욱;최규하
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.214-221
    • /
    • 2007
  • This paper presents a myoelectric hand prosthesis(MHP) with two degree of freedom(2-DOF), which consists of a mechanical hand, a surface myoelectric sensor(SMES) for measuring myoelectric signal, a control system and a charging battery. The actuation for the 2-DOF hand functions such as grasping and wrist rotation was performed by two DC-motors, and controlled by myoelectric signal measured from the residual forearm muscle. The grip force of the MHP was automatically changed by a mechanical automatic speed reducer mounted on the hand. The skin interface of SMES was composed of the electrodes using the SUS440 metal in order to endure a wet condition due to the sweat. The sensor was embedded with a amplifier and a filter circuit for rejecting the offset voltage caused by power line noises. The control system was composed of the grip force sensor, the slip sensor, and the two controllers. The two controllers were made of a RISC-type microprocessor, and its software was executed on a real-time kernel. The control system used Force Sensing Resistors, FSR, as slip pick-ups at the fingertip of a thumb and the grip force information was obtained from a strain-gauge on the lever of the MHP. The experimental results were showed that the proposed control system is feasible for the MHP.

전동의수 훈련시스템 설계 (Design of training system for Myoelectric Hand Prosthesis)

  • 최기원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.437-439
    • /
    • 2008
  • This paper presents the training system of myoelectric hand prosthesis controlling according to myoelectric signal generated in the human muscle. The training system consist of a trainer, a program for training. The experimental results proved the reliability of proposed training system.

  • PDF

상지절단자용 전동의수 증례연구 (A Case Study of Myoelectric Hand Prosthesis for Upper Extremity Amputee)

  • 강주호;김명회;이정원
    • 한국전문물리치료학회지
    • /
    • 제2권1호
    • /
    • pp.80-87
    • /
    • 1995
  • The purpose of this case study was to introduce a myoelectric hand prosthesis for upper extremity amputee and prosthetic training program. Limb loss can result from disease, injury, or congenital causes. Trauma has been increasingly important role as the cause of amputaion in young, vigorous, and otherwise healthy individuals. The higher the level of amputation the greater the functional loss of the part, and the more the amputee must depend on the prostheis for fuction and cosmesis. Myoelectrical control of prostheses is a recent development and has been steadily gaining in clinical use over the past 20 years. Such a prosthesis uses signals from muscle contraction within the stump to activate a battery driven moter that operates specific component fuctions of the prosthesis. This twenty years old male case was operated a right above-elbow amputation due to tracffic accident and admitted to Yonsei Rehabilitaion hospital for the preprosthetic and prosthetic training. The case was able to successfully complete his myoelectric hand prosthesis training in the February of 1995.

  • PDF

근전위 신호구동형 전동의수의 제어시스템 설계 (Design of Control System for Myoelectric Signal Driving Type Myoelectric Hand Prosthesis)

  • 최기원;이명언;라순길;최규하
    • 전력전자학회논문지
    • /
    • 제12권3호
    • /
    • pp.248-257
    • /
    • 2007
  • 본 논문은 사람의 근육에서 발생하는 근전위 신호를 사용하여 2 자유도를 갖는 전동의수를 구동하기 위한 제어시스템을 제안한다. 근전위 신호를 측정하기 위한 표면 근전위 센서는 근전위 신호의 출력 특성을 이용하여 근전위 센서의 입력부와 회로부를 설계한다. 제어시스템은 전동의수를 구동하기 위하여 두 개의 제어기와 전동의수의 파지력을 측정하기 위한 파지력 센서와 파지한 물체의 미끌림을 감지하기 위한 미끌림 센서로 구성되어 있다. 가상의 근전위 신호를 이용한 실험과 정상인의 실험을 통하여 제안된 제어시스템의 신뢰성을 검증하였다.

근전위 신호구동형 전동의수의 파지력 제어 (Grip Force Control of Myoelectric Signal Driving Type Myoelectric Hand Prosthesis)

  • 최기원;최규하;신우석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.340-342
    • /
    • 2007
  • This paper presents the grip force control of myoelectric hand prosthesis according to myoelectric signal generated in the human muscle. The control system consist of a controller for driving DC motor, torque sensor for measuring out torque of motor, slip sensor for detecting slip of torque. The experimental results proved the reliability of proposed control system.

  • PDF

Clinical outcomes of a low-cost single-channel myoelectric-interface three-dimensional hand prosthesis

  • Ku, Inhoe;Lee, Gordon K.;Park, Chan Yong;Lee, Janghyuk;Jeong, Euicheol
    • Archives of Plastic Surgery
    • /
    • 제46권4호
    • /
    • pp.303-310
    • /
    • 2019
  • Background Prosthetic hands with a myoelectric interface have recently received interest within the broader category of hand prostheses, but their high cost is a major barrier to use. Modern three-dimensional (3D) printing technology has enabled more widespread development and cost-effectiveness in the field of prostheses. The objective of the present study was to evaluate the clinical impact of a low-cost 3D-printed myoelectric-interface prosthetic hand on patients' daily life. Methods A prospective review of all upper-arm transradial amputation amputees who used 3D-printed myoelectric interface prostheses (Mark V) between January 2016 and August 2017 was conducted. The functional outcomes of prosthesis usage over a 3-month follow-up period were measured using a validated method (Orthotics Prosthetics User Survey-Upper Extremity Functional Status [OPUS-UEFS]). In addition, the correlation between the length of the amputated radius and changes in OPUS-UEFS scores was analyzed. Results Ten patients were included in the study. After use of the 3D-printed myoelectric single electromyography channel prosthesis for 3 months, the average OPUS-UEFS score significantly increased from 45.50 to 60.10. The Spearman correlation coefficient (r) of the correlation between radius length and OPUS-UEFS at the 3rd month of prosthetic use was 0.815. Conclusions This low-cost 3D-printed myoelectric-interface prosthetic hand with a single reliable myoelectrical signal shows the potential to positively impact amputees' quality of life through daily usage. The emergence of a low-cost 3D-printed myoelectric prosthesis could lead to new market trends, with such a device gaining popularity via reduced production costs and increased market demand.

2자유도 전동의수의 제어알고리즘 설계 (Design of control algorism for 2 DOF myoelectric hand prosthesis)

  • 최기원;최규하;김홍성;신우석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.250-252
    • /
    • 2007
  • In this paper presents a control algorism for myoelectric hand prosthesis(MHP) with 2 degree of freedom(DOF), which consists of a mechanical hand, a surface myoelectric sensor(SMES) for measuring myoelectric signal, a control system and a charging battery. The actuation for the 2-DOF hand functions such as grasping and wrist rotation was performed by two DC-motors, and controlled by myoelectric signal measured from the residual forearm muscle. The two controllers were made of a RISC-type microprocessor, and its software was executed on a real-time kernel. The experimental results were showed that the proposed a control algorism is feasible for the MHP.

  • PDF