• Title/Summary/Keyword: Myocardial perfusion MRI

Search Result 8, Processing Time 0.013 seconds

Perceived Dark Rim Artifact in First-Pass Myocardial Perfusion Magnetic Resonance Imaging Due to Visual Illusion

  • Taehoon Shin;Krishna S. Nayak
    • Korean Journal of Radiology
    • /
    • v.21 no.4
    • /
    • pp.462-470
    • /
    • 2020
  • Objective: To demonstrate that human visual illusion can contribute to sub-endocardial dark rim artifact in contrast-enhanced myocardial perfusion magnetic resonance images. Materials and Methods: Numerical phantoms were generated to simulate the first-passage of contrast agent in the heart, and rendered in conventional gray scale as well as in color scale with reduced luminance variation. Cardiac perfusion images were acquired from two healthy volunteers, and were displayed by the same gray and color scales used in the numerical study. Before and after k-space windowing, the left ventricle (LV)-myocardium boarders were analyzed visually and quantitatively through intensity profiles perpendicular the boarders. Results: k-space windowing yielded monotonically decreasing signal intensity near the LV-myocardium boarder in the phantom images, as confirmed by negative finite difference values near the board ranging -1.07 to -0.14. However, the dark band still appears, which is perceived by visual illusion. Dark rim is perceived in the in-vivo images after k-space windowing that removed the quantitative signal dip, suggesting that the perceived dark rim is a visual illusion. The perceived dark rim is stronger at peak LV enhancement than the peak myocardial enhancement, due to the larger intensity difference between LV and myocardium. In both numerical phantom and in-vivo images, the illusory dark band is not visible in the color map due to reduced luminance variation. Conclusion: Visual illusion is another potential cause of dark rim artifact in contrast-enhanced myocardial perfusion MRI as demonstrated by illusory rim perceived in the absence of quantitative intensity undershoot.

Cardiac MRI (심장 자기공명영상)

  • Lee, Jong-Min
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • The obstacles for cardiac imaging are motion artifacts due to cardiac motion, respiration, and blood flow, and low signal due to small tissue volume of heart. To overcome these obstacles, fast imaging technique with ECG gating is utilized. Cardiac exam using MRI comprises of morphology, ventricular function, myocardial perfusion, metabolism, and coronary artery morphology. During cardiac morphology evaluation, double and triple inversion recovery techniques are used to depict myocardial fluidity and soft tissue structure such as fat tissue, respectively. By checking the first-pass enhancement of myocardium using contrast-enhanced fast gradient echo technique, myocardial blood flow can be evaluated. In addition, delayed imaging in 10 - 15 minutes can inform myocardial destruction such as chronic myocardial infarction. Ventricular function including regional and global wall motion can be checked by fast gradient echo cine imaging in quantitative way. MRI is acknowledged to be practical for integrated cardiac evaluation technique except coronary angiography. Especially delay imaging is the greatest merit of MRI in myocardial viability evaluation.

  • PDF

Diagnostic Accuracy and Evaluation of Myocardial Viability by Cardiac Magnetic Resonance Imaging in Acute Myocardial Infarction: A Comparison with Thallium-201 Myocardial SPECT (급성심근경색증에서의 심장자기공명영상술의 진단 정확도와 심근 생존력 평가: TI-201 심근관류 SPECT와의 비교)

  • Kim Hye-seon;Park Dong Woo;Kim Yongsoo;Kim Young-sun;Choi Yo Won;Jeon Seok Chul;Seo Heung Suk;Hahm Chang Kok;Kim Soon Kil;Ahn You hern;Choi Yoon Young;Park Choong-Ki
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.100-107
    • /
    • 2003
  • Purpose : To assess the usefulness of cardiac MR imaging (MRI) in the diagnosis of acute myocardial infarction and in the assessment of myocardial viability in comparision with T1-201 SPECT. Materials and Methods : We retrospectively studied 17 patients who complained of chest pain and dyspnea with cardiac MRI . The patients were evaluated for the presence or absence of high signal intensity on T2-weighted image (T2wI), abnormal wall motion on 2D-FIESTA, perfusion defect on Gd-DTPA enhanced T1WI, and delayed myocardial enhancement on 15-minutes delay Gd-DTPA enhanced T1WI. The results were correlated with the images on T1-201 SPECT, taken at rest and stress, through which reversibility of perfusion defect was assessed. Results : Both cardiac MRI and T1-201 SPECT proved to be useful methods for diagnosing acute myocardial infarction. In order of decreasing correspondence, T2WI, T1-201 SPECT, delayed enhancement study, and wall motion images all showed significant statistical correlation with the clinical diagnosis of myocardial infarction. Perfusion MRI, on the other hand, showed no significant statistical difference was found between T1-201 SPECT and cardiac MRI. The results on T2WI showed high accordance with those on Tl-201 SPECT, while delayed myocardial enhancement and wall motion studies showed no agreement with Tl-201 SPECT. Conclusion : Cardiac MRI is useful method for diagnosis of acute myocardiac infarction. With respect to the assessment of myocardial viability, the results obtained on cardiac MRI showed high agreement with those on Tl-201 SPECT. However, further study is necessary at this point for standardization and establishment of the methods for assessing myocardial viability on cardiac MRI.

  • PDF

Scintigraphic Assessment of Myocardial Viability (신티그라피에 의한 심근생존능 평가)

  • Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.155-160
    • /
    • 1993
  • The identification of viable myocardium in patients with coronary artery disease and left ventricular dysfunction is an issue of increasing clinical relavance in the current era of myocardial revascularization. There are at least two forms of reversible myocardial dysfunction. Early reperfusion does not always lead to immediate functional improvement; rather, the return of contractility in tissue salvaged by reperfusion is delayed for hours, days or even weeks, a phenomenon that has been termed "stunned myocardium". Some patients with coronary artery disease show myocardial dysfunction at rest which are associated with reduced perfusion, and which disappear after revascularization; this phenomenon has been termed "hibernating myocardium". Recently, cardiac imaging techniques that evaluate myocardial viability on the basis of perfusion-contraction mismatch and inotropic reserve have gained substantial popularity and clinical success. This review focus on the application of $^{201}TI$ and $^{99m}Tc-MIBI$ to address myocardial viability in patients with hibernating and stunned myocardium. It is clear that 4-hour redistribution images of $^{201}TI$ underestimate ischemia and overestimate scar. Delayed imaging and reinjection imaging have been developed for the assessment of viability. Among many protocols suggested, stress-redistribution-reinjection imaging gained most popularity. Although $^{99m}Tc-MIBI$ could identify myocardial viability, $^{201}TI$ reinjection technique was regarded as superior to it. In conclusion, $^{201}TI$ stress, 4-hr rest redistribution, and reinjection imaging technique may be the most preferable method for evaluation of myocardial viability.

  • PDF

Autologous Bone Marrow Cell Transplantation Combined with Off-pump Coronary Artery Bypass Grafting in Ischemic Myocardium (허혈성 심근에 관상동맥우회술과 병행한 자가 골수줄기세포 이식)

  • 김현옥;곽영란;강석민;장양수;임상현;안지영;이창영;강면식;유경종
    • Journal of Chest Surgery
    • /
    • v.37 no.7
    • /
    • pp.547-552
    • /
    • 2004
  • Recently, autologous bone marrow cell transplantation (CTx) for angiogenesis and myogenesis in ischemic myocardium has been extensively investigated to improve heart functions. This study was designed to evaluate the effects of CTx with off-pump coronary artery bypass grafting (OPCAB) in patients who were not feasible for complete revascularization. Material and Method: Four male patients underwent CTx and OPCAB simultaneously. Bone marrow was aspirated from iliac bone. Mean 1.5 ${\times}$ 10$^{9}$ mononuclear cells including mean 6.7 ${\times}$ 10$^{6}$ CD34 + cells and 3.7 ${\times}$ 10$^{6}$ AC133 + cells were obtained and concentrated with 10 cc. These cells were transplanted into non-graftable ischemic myocardium after OPCAB. The heart function of all patients were evaluated using the MIBI scan, echocardiogram and MRI preoperatively. The effects of CTx was evaluated using MIBI scan and echocardiogram at 1 month postoperatively. Result: An average of 2 grafts were bypassed to left anterior descending artery territory. Other territories were transplanted with isolated mononuclear cell. All patients had uncomplicated postoperative course. After 1 month follow up, there were improvement in symptom, ejection fraction (from 49% to 55%) on echocardiogram and myocardial perfusion on MIBI scan in all patients. Conclusion: These preliminary data showed improvement of heart function and myocardial perfusion and also showed the feasibility and safety of combined therapy with OPCAB and CTx in ischemic myocardium. However, the effectiveness of CTx alone cannot be readily assessed. Further randomized, controlled studies are required to evaluate the effectiveness of CTx alone.

First-pass Stress Perfusion MR Imaging Findings of Apical Hypertrophic Cardiomyopathy: with Relation to LV Wall Thickness and Late Gadolinium-enhancement (심첨형 비후성 심근병증에서의 스트레스 부하 관류 자기공명영상 소견: 좌심실 벽 비후 정도와 지연 조영 증강 간의 관련성)

  • Yoo, Jin Young;Chun, Eun Ju;Kim, Yeo-Koon;Choi, Sang Il;Choi, Dong-Ju
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.7-16
    • /
    • 2014
  • Purpose : To evaluate the prevalence and pattern of perfusion defect (PD) on first-pass stress perfusion MR imaging in relation with the degree of left ventricular hypertrophy (LVH) and late gadolinium-enhancement (LGE) in patients with apical hypertrophic cardiomyopathy (APH). Materials and Methods: Cardiac MR imaging with first-pass stress perfusion, cine, and LGE sequence was performed in 26 patients with APH from January 2008 to December 2012. We analyzed a total of 416 segments for LV wall thickness on end-diastolic phase of cine images, and evaluated the number of hypertrophied segment and number of consecutive hypertrophied segment (NCH). We assessed the presence or absence of PD and LGE from all patients. If there was PD, we subdivided the pattern into sporadic (sporadic-PD) or ring (ring-PD). Using univariate logistic method, we obtained the independent predictor for presence of overall PD and ring-PD. Results: PD on stress perfusion MRI was observed in 20 patients (76.9%), 12 of them (60%) showed ring-PD. Maximal LV wall thickness and number of hypertrophied segment were independent predictors for overall PD (all, p < 0.05). NCH with more than 3 segments was an additional independent factor for ring-PD. However, LGE was not statistically related with PD in patients with APH. Conclusion: About three quarters of the patients with APH showed PD, most of them represented as ring-PD. LVH degree or distribution was related with pattern of PD, however, LGE was not related with PD. Therefore, the clinical significance of PD in the patients with APH seems to be different from those with non-APH, and further comparison study between the two groups should be carried out.

Recent Advances in Nuclear Medicine Imaging Instrumentation (핵의학 영상기기의 최근 진보)

  • Jung, Jin-Ho;Choi, Yong;Hong, Key-Jo;Min, Byung-Jun;Hu, Wei;Kang, Ji-Hoon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.98-111
    • /
    • 2008
  • This review introduces advances in clinical and pre-clinical single photon emission computed tomography (SPECT) and positron emission tomography (PET) providing noninvasive functional images of biological processes. Development of new collimation techniques such as multi-pinhole and slit-slat collimators permits the improvement of system spatial resolution and sensitivity of SPECT. Application specific SPECT systems using smaller and compact solid-state detector have been customized for myocardial perfusion imaging with higher performance. Combined SPECT/CT providing improved diagnostic and functional capabilities has been introduced. Advances in PET and CT instrumentation have been incorporated in the PET/CT design that provide the metabolic information from PET superimposed on the anatomic information from CT. Improvements in the sensitivity of PET have achieved by the fully 3D acquisition with no septa and the extension of axial field-of-view. With the development of faster scintillation crystals and electronics, time-of-flight (TOF) PET is now commercially available allowing the increase in the signal-to-noise ratio by incorporation of TOF information into the PET reconstruction process. Hybrid PET/SPECT/CT systems has become commercially available for molecular imaging in small animal models. The pre-clinical systems have improved spatial resolution using depth-of-interaction measurement and new collimators. The recent works on solid state detector and dual modality nuclear medicine instrumentations incorporating MRI and optical imagers will also be discussed.