Predictive Values of Early Rest/24 Hour Delay T1-201 Perfusion SPECT for Wall Motion Improvement in Patients with Acute Myocardial Infarction After Reperfusion (급성 심근 경색 환자에서 재관류 후 조기에 시행한 휴식/24시간 지연 T1-201 심근 SPECT의 심근벽 운동 호전 예측능)

  • Hyun, In-Young;Kwan, June
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.259-265
    • /
    • 1998
  • Purpose: We studied early rest/24 hour delay T1-201 perfusion SPECT for prediction of wall motion improvement after reperfusion in patients with acute myocardial infarction. Materials and Methods: Among 17 patients (male/female= 11/6, age: $59{\pm}13$) with acute myocardial infarction, 15 patients were treated with percutaneous transcoronary angioplasty (direct:2, delay: 11) and intravenous urokinase (2). Spontaneous resolution occurred in infarct-related arteries of 2 patients. We confirmed TIMI 3 flow of infarct-related artery after reperfusion in all patients with coronary angiography. We performed rest T1-201 perfusion SPECT less then 6 hours after reperfusion and delay T1-201 perfusion SPECT next day. T1-201 uptake was visually graded as 4 point score from normal (0) to severe defect (3). Rest T1-201 uptake ${\le}2$ or combination of rest T1-201 uptake ${\le}2$ or late reversibility were considered to be viable. Myocardial wall motion was graded as 5 point score from normal (1) to dyskinesia (5). Myocardial wall motion was considered to be improved when a segment showed an improvement ${\ge} 1$ grade in follow up echo compared with the baseline values. Results: Among 98 segments with wall motion abnormality, the severity of myocardial wall motion decrease was as follow: mild hypokinesia: 18/98 (18%), severe hypokinesia: 28/98 (29%), akinesia: 51/98 (52%), dyskinesia: 1/98 (1%). The wall motion improved in 85%. Redistribution (13%), and reverse redistribution (4%) were observed in 24 hour delay SPECT. Positive predictive value (PPV) and negative predictive value (NPV) of combination of late reversibility and rest T1-201 uptake were 99%, and 54%. PPV and NPV of rest T1-201 uptake were 100% and 52% respectively. Predictive values of combination of rest T1-201 uptake and late reversibility were not significantly different compared with predictive values of rest T1-201 uptake only. Conclusion: We conclude that early T1-201 perfusion SPECT predict myocardial wall motion improvement with excellent positive but relatively low negative predictive values in patients with acute myocardial infarction after reperfusion.

  • PDF

Comparison of Polar Maps of Dipyridamole Stress/Rest MIBI Myocardial SPECT and Coronary Angiography in Coronary Artery Disease (관동맥질환에서 디피리다몰부하 $^{99m}Tc$-MIBI 심근 SPECT 극성지도와 관동맥 조영소견의 비교)

  • Lee, Myung-Chul;Lee, Dong-Soo;Lee, Myung-Yong;Choi, Chang-Woon;Sohn, Dae-Won;Chung, June-Key;Lee, Myong-Mook;Park, Young-Bae;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.1
    • /
    • pp.51-58
    • /
    • 1993
  • We have anlayzed the polar maps of dipyridamole stress/rest $^{99m}Tc$-MIBI SPECT and compared the quantitated perfusion defects of dipyridamole stress polar map and the findings of coronary angiography in 56 pateints with coronary artery diseases. We performed the same day dipyridamole stress-rest myocardial SPECT, reconstructed the polar maps according to Cedars-Sinai method and quantitated perfusion detects of total myocardium and the territory of each artery, comparing the polar maps of patients with normal files. Stenosis more than 50 percent was considered significant and myocardial ischemic score was calculated as summed score of percents of main coronary arteries. Positive concordance of myocardial SPECT with coronary angiography were 82.6% with left anterior descending artery (LAD), 85.7% with left circumflex artery (LCx) and 78.6% with right coronary artery (RCA). Perfusion defect of SPECT polar map and the stenosis of coronary artery showed the contingency phi of 0.55 (p<0.0001) with total atreries, 0.38 (p = 0.016) with LAD, 0.50 (p<0.0001) with LCx and 0.40 (p = 0.007) with RCA. Dipyridamole stress percent defect of polar map was correlated with myocardial ischemic score with Spearman's rho of 0.47 (p = 0.001) in total arteries, 0.48 (p=0.001) in LAD, 0.56 (p < 0.001) in LCx and 0.38 (p=0.002) in RCA. These findings revealed that defect of the dipyridamole stress myocardial $^{99m}Tc$-MIBI SPECT and the percent extent of this defect were related with significant artery stenosis of individual arteries and the degree of stenosis. We thought that we could use the defects in the polar map of dipyridamole stress $^{99m}Tc$-MIBI SPECT for the quantification of myocardiasl perfusion decrease.

  • PDF

Analysis of Quantitative Indices in Tl-201 Myocardial Perfusion SPECT: Comparison of 4DM, QPS, and ECT Program (Tl-201 심근 관류 SPECT에서 4DM, QPS, ECT 프로그램의 정량적 지표 비교 분석)

  • Lee, Dong-Hun;Shim, Dong-Oh;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.67-75
    • /
    • 2009
  • Purpose: As to the analytical method of data, the various programs in which it is used for the quantitative rating of the Tl-201 myocardial perfusion SPECT are reported that there is a difference. Therefore, the measured value error of the mutual program is expected to be generated even if the quantitative analysis is made against data of the same patient. Using quantitative index that able to represent myocardial perfusion defect level, we aimed to determine correlation among three myocardial perfusion analysis programs 4DM (4DMSPECT), QPS (Quantitative Perfusion SPECT), ECT (Emory Cardiac Toolbox) that be used generally in most departments of Nuclear Medicine. Materials and Methods: We analyzed the 145 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Mediacal Center from December 1th 2008 to February 14th 2008. We sorted as normal group and abnormal group. Normal group consist of 80 patients (Male/Female=38/42, age:$65.1{\pm}9.9$) who have low possibility of cardiovascular disease. And abnormal group consist of 65 patients (Male/Female=45/20, age:$63.0{\pm}8.7$) who were diagnosed cardiovascular disease with reversible perfusion defect or fixed perfusion defect through myocardial perfusion SPECT results. Using the 4DM, QPS, and ECT programs, the total defect extent (TDE) such as LAD, LCX, RCA and the summed stress score (SSS) have been analysed for their correlations and statistical comparison with the paried t-test for the quantitative indices analysed from each group. Results: The correlation of 4DM:QPS, QPS:ECT, ECT:4DM each group result from 145 patients is 0.84, 0.86, 0.82 at SSS, 0.87, 0.84, 0.87 at TDE, and both index showed good correlation. In paired t-test and Bland-Altman analysis results showed no statistically significant difference in the comparison of QPS:ECT at the mean SSS and TDE, 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index. The correlation of 4DM:QPS, QPS:ECT, ECT:4DM program results from abnormal group (65 patients) is 0.72, 0.72, 0.70 at SSS and 0.77, 0.70, 0.77 at TDE and TDE and SSS has a good correlation. In abnormal group, paired t-test and Bland-Altman analysis results showed no statistically significant difference at QPS:ECT SSS (p=0.89) and TDE (p=0.23) comparison, 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index (p<0.01). In normal group (80 patients), paired t-test and Bland-Altman analysis results showed no statistically significant difference at QPS:ECT SSS (p=0.95) and TDE (p=0.73) comparison. And 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index (p<0.01). Conclusions: The perfusion defect of the Tl-201 myocardial perfusion SPECT was analyzed in not only the patient in whom it has the cardiovascular disease but also the patient in whom the possibility of the cardiovascular disease is few. In the comparison of the all group research, the mean of the TDE and SSS, 4DM was lower than QPS and ECT progrms. Each program showed good correlation and the results showed statistically significant difference. However, in this way, it is determined to be compatible about the analysis value in which the large-scale side between the programs uses each program a difference in a clinical in the Bland-Altman analyzed result in spite of the good correlation and cannot use. but, this analyzed result will be able to be usefully used as the reference material for the clinical read and is expected.

  • PDF

Correlation between Reverse Redistribution and Subendocardial Myocardial Infarction Observed in Myocardial Contrast Echocardiography (역재분포 소견과 심근조영 심초음파에서 보인 심내막하경색과의 관계)

  • Kim, Sung-Eun;Choe, Won-Sick;Kwan, Jun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.228-233
    • /
    • 2000
  • Purpose: The aim of this study is to better understand the pattern and nature of reverse redistribution (RR) in myocardial perfusion imaging. Materials and Methods: In consecutive 20 acute myocardial infarction (MI) patients, frequency of RR was correlated with that of subendocardial MI that was detected by myocardial contrast echocardiography (MCE). RR was judged to be present when there was more than one grade of worsening in perfusion at 24 hr delayed images compared with the initial rest images. MCE evaluated the significant lack of opacification in the subendocardial myocardium relative to the subepicardial myocardium to suggest the subendocardial MI. Kendall's nonparametric correlation coefficiency was calculated. Results: Concordant cases were 15 of 20 (75%) and correlation was statistically significant (p=0.0285). Conclusion: Our results suggested that RR was correlated with MCE-detected nontransmural MI.

  • PDF

The Evaluation of Clinical Usefulness on Application of Myocardial Extract in Quantitative Perfusion SPECT (QPS 프로그램에서 Myocardial extract 적용에 따른 임상적 유용성 평가)

  • Yun, Jong-Jun;Lim, Yeong-Hyeon;Lee, Mu-Seok;Song, Hyeon-Seok;Jeong, Ji-Uk;Park, Se-Yun;Kim, Jae-Hwan;Kim, Jeong-Uk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.88-93
    • /
    • 2011
  • Purpose: As to analytical method of data, the AutoQUANT software in which it is used quantitative rating of the myocardial perfusion SPECT are reported that there is a difference. Therefore the measured value error of the mutual program is expected to be generated even if the quantitative analysis is made data of the same patient. The purpose of this study is to offer the comparative analysis of myocardial extract method in Quantitative Perfusion SPECT. Materials and methods: We analyzed the 51 patients who were examined by Tc-99m MIBI gated myocardial SPECT in nuclear medicine department of Pusan National University Hospital from June to December 2010(34 men, 17 women, mean age $66.5{\pm}9.9$). We acquired the extracted image in myocardial extract protocol. QPS program that uses the AutoQUANT software measured TID(Transient Ischemic Dilation), ESD(Extent of Stress Defect), SSS(Summed Stress Score). Then analyzed the results. Results: The correlation of appyling myocardial extract is TID(r=0.98), ESD(r=0.99), SSS(r=0.99). In the 95% confidence limit, there was no satistically significant difference(TID p=0.78, ESD p=0.31, SSS p=0.19). After blinding test with a physician for making a qualitative analysis, there was no difference. Conclusion: Quantitative indices in QPS program showed good correlation and the results showed no statistically signigicant difference. The variance between method was small. therefore, the functional parameters by each method can be used interchangeably. Also, we expect patient's satisfaction.

  • PDF

Microvascular Myocardial Ischemia in Patients With Diabetes Without Obstructive Coronary Stenosis and Its Association With Angina

  • Yarong Yu;Wenli Yang;Xu Dai;Lihua Yu;Ziting Lan;Xiaoying Ding;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.24 no.11
    • /
    • pp.1081-1092
    • /
    • 2023
  • Objective: To investigate the incidence of microvascular myocardial ischemia in diabetic patients without obstructive coronary artery disease (CAD) and its relationship with angina. Materials and Methods: Diabetic patients and an intermediate-to-high pretest probability of CAD were prospectively enrolled. Non-diabetic patients but with an intermediate-to-high pretest probability of CAD were retrospectively included as controls. The patients underwent dynamic computed tomography-myocardial perfusion imaging (CT-MPI) and coronary computed tomography angiography (CCTA) to quantify coronary stenosis, myocardial blood flow (MBF), and extracellular volume (ECV). The proportion of patients with microvascular myocardial ischemia, defined as any myocardial segment with a mean MBF ≤ of 100 mL/min/100 mL, in patients without obstructive CAD (Coronary Artery Disease-Reporting and Data System [CAD-RADS] grade 0-2 on CCTA) was determined. Various quantitative parameters of the patients with and without diabetes without obstructive CAD were compared. Multivariable analysis was used to determine the association between microvascular myocardial ischemia and angina symptoms in diabetic patients without obstructive CAD. Results: One hundred and fifty-two diabetic patients (mean age: 59.7 ± 10.7; 77 males) and 266 non-diabetic patients (62.0 ± 12.3; 167 males) were enrolled; CCTA revealed 113 and 155 patients without obstructive CAD, respectively. For patients without obstructive CAD, the mean global MBF was significantly lower for those with diabetes than for those without (152.8 mL/min/100 mL vs. 170.4 mL/min/100 mL, P < 0.001). The mean ECV was significantly higher for diabetic patients (27.2% vs. 25.8%, P = 0.009). Among the patients without obstructive CAD, the incidence of microvascular myocardial ischemia (36.3% [41/113] vs. 10.3% [16/155], P < 0.001) and interstitial fibrosis (69.9% [79/113] vs. 33.3% [8/24], P = 0.001) were significantly higher in diabetic patients than in the controls. The presence of microvascular myocardial ischemia was independently associated with angina symptoms (adjusted odds ratio = 3.439, P = 0.037) in diabetic patients but without obstructive CAD. Conclusion: Dynamic CT-MPI + CCTA revealed a high incidence of microvascular myocardial ischemia in diabetic patients without obstructive CAD. Microvascular myocardial ischemia is strongly associated with angina.