• Title/Summary/Keyword: Myocardial perfusion

Search Result 276, Processing Time 0.04 seconds

Abnormal Perfusion on Myocardial Perfusion SPECT in Patients with Wolff-Parkinson-White Syndrome (Wolff-Parkinson-White 증후군 환자의 심근 관류 이상)

  • Kang, Do-Young;Cha, Kwang-Soo;Han, Seung-Ho;Park, Tae-Ho;Kim, Moo-Hyun;Kim, Young-Dae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.9-14
    • /
    • 2005
  • Purpose: Abnormal myocardial perfusion may be caused by ventricular preexcitation, but its location, extent, severity and correlation with accessory pathway (AP) are not established. We evaluated perfusion patterns on myocardial perfusion SPECT and location of AP in patients with WPW (Wolff-Parkinson-White) syndrome. Materials and Methods: Adenosine Tc-99m MIBI or Tl-201 myocardial perfusion SPECT was performed in 11 patients with WPW syndrome. Perfusion defects (PD) were compared to AP location based on ECG with Fitzpatrick's algorithm or electrophysiologic study and radiofrequency catheter ablation. Results: Patients had atypical chest discomfort or no symptom. Risk of coronary artery disease (CAD) was below 0.1 in 11 patients using the nomogram to estimate the probability of CAD. Coronary angiography was performed in 4 patients (mid-LAD 50% in one, normal in others). In 4 patients, AP localization was done by electrophysiologic study and radiofrequency catheter ablation (RFCA). Small to large extent ($11.0{\pm}8.5%$, range:$3{\sim}35%$) and mild to moderate severity ($-71{\pm}42.7%$, range:$-2l7{\sim}-39%$) of reversible (n=9) or fixed (n=1) perfusion defects were noted. One patient with right free wall (right lateral) AP showed normal. PD locations were variable following the location of AP. One patient with left lateral wall AP was followed 6 weeks after RFCA and showed significantly decreased PD on SPECT with successful ablation. Conclusion: Myocardial perfusion defect showed variable extent, severity and location in patients with WPW syndrome. Abnormal perfusion defect showed in most of all patients, but it did not seem to be correlated specifically with location of accessory pathway and coronary artery disease. Therefore myocardial perfusion SPECT should be interpreted carefully in patients with WPW syndrome.

Effect of Caffeine on Coronary Circulation and Calcium Release in Isolated Guinea Pig Hearts (Guinea Pig Heart의 관상동맥 순환기능과 Calcium Release에 있어서 Caffeine이 미치는 영향)

  • 김은지
    • Journal of Nutrition and Health
    • /
    • v.25 no.7
    • /
    • pp.597-607
    • /
    • 1992
  • The present study examined effects of caffeine on coronary circulation myocardial oxygen me-tabolism and calcium release in isolated perfused guinea pig hearts. Intracoronary caffeine({{{{ {10 }^{-5 } }}}}∼{{{{ { 10}^{-3 } }}}}M) was employed for 10 minutes to measure coronary perfusate flow(CF) and coronary vascular sresistance(CVR) at a constant coronary perfusion pressure of 80 cmH2O Perfusate myocardial oxygen consumption(MVO2) and percent oxygen extraction(%EC2) were calcula-ted. In addition calcium contents in both perfusate samples were measured to calculate calcium release in coronary venous effluent. Caffeine significantly decreased CF and increased CVR during 10 minutes of caffeine perfusion regardless of dose of caffeine perfused exhibiting time-response. While % EO2 was significantly enhanced with caffeine MVO2 was markedly reduced. The coronary venous perfusate pH dcreased during the perfusion with caffeine. These changes were consistent with caffeine-induced metabolic acidosis. Calcium release appeared to be dose-dependent and high dose of caffeine greatly increased venous calcium release even 2 minutes after perfusion with carffeine. These finding in dicate that caffeine produced coronary vasoconst-riction with increased calcium release in isolated perfused guinea pig hearts. Additionaly this vasoconstrictor response mignt be due tin part to the direct actions of caffeine.

  • PDF

The Role of Rest Image in Patients Showing Normal Stress Image on Tc-99m Myocardial Perfusion Scan (심근 관류스캔 중 정상 부하영상 소견을 보인 환자에서 휴식기 영상의 필요성에 대한 평가)

  • Bom, Hee-Seung;Song, Ho-Chun;Min, Jung-Jun;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.502-506
    • /
    • 1996
  • Tc-99m myocardial perfusion agents such as Tc-99m sestamibi or Tc-99m tetrofosmin has advantages over T1-201 for myocardial perfusion scan fuck as low attenuation and easy availability. However, Tc-99m agents do not redistribute so they need to be given T times, namely after stress and at rest. To evaluate whether rest image is needed in patients showing normal stress image, 43 patients who underwent both myocardial perfusion scan and coronary angiography and showed normal stress images were evaluated. Findings of rest images of them were evaluated whether they change the diagnosis or treatment plans. Among 43 patients who showed normal stress myocardial perfusion imaging, 31 (72.1%) showed no additional informations. However, among 5 patients with vasospastic angina 4 (80%) showed abnormal rest images in spite of normal stress images. So, when vasospastic angina is suspected clinically, rest image could be helpful in identifying patients with coronary vasospasm. In conclusion, rest myocardial perfusion images were not helpful in 72.1 % of patients with angina when stress images were normal. In only exception was those with vasospastic angina.

  • PDF

Dynamic CT Myocardial Perfusion Imaging in Patients without Obstructive Coronary Artery Disease: Quantification of Myocardial Blood Flow according to Varied Heart Rate Increments after Stress

  • Lihua Yu;Xiaofeng Tao;Xu Dai;Ting Liu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.22 no.1
    • /
    • pp.97-105
    • /
    • 2021
  • Objective: The present study aimed to investigate the association between myocardial blood flow (MBF) quantified by dynamic CT myocardial perfusion imaging (CT-MPI) and the increments in heart rate (HR) after stress in patients without obstructive coronary artery disease. Materials and Methods: We retrospectively included 204 subjects who underwent both dynamic CT-MPI and coronary CT angiography (CCTA). Patients with more than minimal coronary stenosis (diameter ≥ 25%), history of myocardial infarction/revascularization, cardiomyopathy, and microvascular dysfunction were excluded. Global MBF at stress was measured using hybrid deconvolution and maximum slope model. Furthermore, the HR increments after stress were recorded. Results: The median radiation dose of dynamic CT-MPI plus CCTA was 5.5 (4.5-6.8) mSv. The median global MBF of all subjects was 156.4 (139.8-180.4) mL/100 mL/min. In subjects with HR increment between 10 to 19 beats per minute (bpm), the global MBF was significantly lower than that of subjects with increment between 20 to 29 bpm (153.3 mL/100 mL/min vs. 171.3 mL/100 mL/min, p = 0.027). This difference became insignificant when the HR increment further increased to ≥ 30 bpm. Conclusion: The global MBF value was associated with the extent of increase in HR after stress. Significantly higher global MBF was seen in subjects with HR increment of ≥ 20 bpm.

Left Ventricular Function Changes Under Normothermic Krebs Perfusate in Newborn Piglet (신생 돼지심장에서 상온의 Krebs 용액 관류에 따른 좌심실 기능의 변화)

  • O, Bong-Seok;Na, Guk-Ju;Lee, Dong-Jun
    • Journal of Chest Surgery
    • /
    • v.23 no.6
    • /
    • pp.1067-1073
    • /
    • 1990
  • To clarify the changes of left ventricular function under normothermia, the time interval between the onset of ischemia and the beginning of contracture of left ventricle[TIC] were recorded in newborn piglet. Myocardial performance was assessed using intraventricular balloon to determine compliance and systolic function after 5 to 10 minutes interval per-fusing normothermic substrate free Krebs solution as a perfusate. The time to onset TIC was 29.5\ulcorner1.7 minutes and peak ischemic contracture was 46.7\ulcorner4.0 minutes[p<0.01]. In myocardial performance, systolic function of left ventricle[defined as cardiac contractility] was kept until 25 minutes of perfusion, but was decreased abruptly after 30 minutes of perfusion[p<0.0018] and diastolic function of left ventricle[defined as diastolic compliance] was kept until 15 minutes of perfusion, but was decreased after 20 minutes of perfusion [p=0.00\ulcorner9]. This study demonstrated maximal time of the tolerance to normothermic global ischemia and functional changes of left ventricle using Krebs perfusate under the same condition.

  • PDF

Post-Coronary Artery Bypass Grafting Myocardial Ischemia Caused by an Overgrown Left Internal Thoracic Artery Side Branch

  • Kim, Eung Re;Oh, Se Jin;Kang, Hyun-Jae;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.47 no.5
    • /
    • pp.465-467
    • /
    • 2014
  • We present a patient who developed recurrent angina after coronary artery bypass grafting (CABG). Myocardial single-photon emission computed tomography (SPECT) demonstrated deterioration in the myocardial perfusion, and coronary angiography revealed an overgrown side branch of the grafted left internal thoracic artery (ITA); otherwise, there were no significant changes compared with previous imaging studies obtained after the CABG. After percutaneous embolization of the grafted left ITA side branch, the angina was resolved and myocardial SPECT showed improved perfusion.

The Comparison of Motion Correction Methods in Myocardial Perfusion SPECT (심근관류 SPECT에서 움직임 보정 방법들의 비교)

  • Park, Jang-Won;Nam, Ki-Pyo;Lee, Hoon-Dong;Kim, Sung-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.28-32
    • /
    • 2014
  • Purpose Patient motion during myocardial perfusion SPECT can produce images that show visual artifacts and perfusion defects. This artifacts and defects remain a significant source of unsatisfactory myocardial perfusion SPECT. Motion correction has been developed as a way to correct and detect the patient motion for reducing artifacts and defects, and each motion correction uses different algorithm. We corrected simulated motion patterns with several motion correction methods and compared those images. Materials and Methods Phantom study was performed. The anthropomorphic torso phantom was made with equal counts from patient's body and simulated defect was added in myocardium phantom for to observe the change in defect. Vertical motion was intentionally generated by moving phantom downward in a returning pattern and in a non-returning pattern throughout the acquisition. In addition, Lateral motion was generated by moving phantom upward in a returning pattern and in a non-returning pattern. The simulated motion patterns were detected and corrected similarly to no-motion pattern image and QPS score, after Motion Detection and Correction Method (MDC), stasis, Hopkins method were applied. Results In phantom study, Changes of perfusion defect were shown in the anterior wall by the simulated phantom motions, and inferior wall's defect was found in some situations. The changes derived from motion were corrected by motion correction methods, but Hopkins and Stasis method showed visual artifact, and this visual artifact did not affect to perfusion score. Conclusion It was confirmed that motion correction method is possible to reduce the motion artifact and artifactual perfusion defect, through the apply on the phantom tests. Motion Detection and Correction Method (MDC) performed better than other method with polar map image and perfusion score result.

  • PDF

Radius Intermedius Stenosis Induced Myocardial Perfusion Defect: Provened by the Fusion Images of Myocardial Perfusion SPECT and 64 Channel CTA (심근관류 SPECT와 64채널 전산화 단층혈관 촬영 사진 융합으로 증명된 radius intermedius 협착에 의한 심근관류 저하)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Park, Jong-Seon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.77-78
    • /
    • 2008
  • A 71-year-old woman was assigned to our department for Tc-99m myocardial perfusion SPECT(MPS) and coronary CT angiography. She admitted for substernal pain, via the ER, 2 days ago. The heart was scanned after intravenous injection of 925 MBq of $^{99m}Tc$-sestamibi adenosine-induced stress SPECT using dual head gamma camera (Hawkeye, GE healthcare. USA). The MPS shows decreased tracer uptake in the apical & mid area of anterior & lateral wall and mid & basal inferior wall. Coronary CT angiograph was obtained using Discovery VCT (GE healthcare). 3D angiography portrayed significant stenosis of ramus intermedius(RI) and posterolateral branch of right coronary artery(PLB) with fibrocalcified plaque. Two images were fused using Cardiac IQ fusion softwear package (Advantage workstation 4.4, GE healthcare) The fusion images explain the perfusion defect of anterior, lateral and inferior wall is due to stenosis of the RI and PLB. And 3 days later, coronary angiography was done and revealed the marked stenosis of RI and PLB. Then balloon angioplasty and stent was instituted in RI. Cardiac SPECT/CT fusion imaging provides additional information about hemodynamic relevance and facilitates lesion interpretation by allowing exact allocation of perfusion defects to its subtending coronary artery.

Usability of Multiple Confocal SPECT SYSTEM in the Myocardial Perfusion SPECT Using $^{99m}Tc$ ($^{99m}Tc$을 이용한 심근 관류 SPECT에서 Multiple Confocal SPECT System의 유용성)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.65-71
    • /
    • 2011
  • Purpose: The recently adopted multiple confocal SPECT SYSTEM (hereinafter called IQ SPECT$^{TM}$) has a high difference from the conventional myocardial perfusion SPECT in the collimator form, image capture method, and image reconstruction method. This study was conducted to compare this novice equipment with the conventional one to design a protocol meeting the IQ SPECT, and also determine the characteristics and usefulness of IQ SPECT. Materials and Methods: 1. For the objects of LEHR (Low energy high resolution) collimator and Multiple confocal collimator, $^{99m}Tc$ 37MBq was put in the acrylic dish then each sensitivity ($cpm/{\mu}Ci$) was measured at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. 2. Based on the sensitivity measure results, IQ SPECT Protocol was designed according to the conventional general myocardial SPECT, then respectively 278 kBq/mL, 7.4 kBq/mL, and 48 kBq/mL of $^{99m}Tc$ were injected into the myocardial and soft tissues and liver site by using the anthropomorphic torso phantom then the myocardial perfusion SPECT was run. 3. For the comparison of FWHMs (Full Width at Half Maximum) resulted from the image reconstruction of LEHR collimator, the FWHMs (mm) were measured with only algorithms changed, in the case of the FBP (Filtered Back projection) method- a reconstruction method of conventional myocardial perfusion SPECT, and the 3D OSEM (Ordered subsets expectation maximization) method of IQ SPECT, by using $^{99m}Tc$ Line source. Results: 1. The values of IQ SPECT collimator sensitivity ($cpm/{\mu}Ci$) were 302, 382, 655, 816, 1178, and those of LEHR collimator were measured as 204, 204, 202, 201, 198, both at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. It was found the difference of sensitivity increases up to 4 times at the distance of 30 cm in the cases of IQ SPECT and LEHR. 2. The myocardial perfusion SPECT Protocol was designed according to the geometric characteristics of IQ SPECT based on the sensitivity results, then the phantom test for the aforesaid protocol was conducted. As a result, it was found the examination time can be reduced 1/4 compared to the past. 3. In the comparison of FWHMs according to the reconstructed algorithm in the FBP method and 3D OSEM method followed after the SEPCT test using a LEHR collimator, the result was obtained that FWHM rose around twice in the 3D OSEM method. Conclusion : The IQ SPECT uses the Multiple confocal collimator for the myocardial perfusion SPECT to enhance the sensitivity and also reduces examination time and contributes to improvement of visual screen quality through the myocardial-specific geometric image capture method and image reconstruction method. Due to such benefits, it is expected patients will receive more comfortable and more accurate examinations and it is considered a further study is required using additional clinical materials.

  • PDF