• Title/Summary/Keyword: Myocardial SPECT

Search Result 183, Processing Time 0.02 seconds

Evaluation of Perfusion and Image Quality Changes by Reconstruction Methods in 13N-Ammonia Myocardial Perfusion PET/CT (13N-암모니아 심근관류 PET/CT 검사 시 영상 재구성 방법에 따른 관류량 변화와 영상 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.69-75
    • /
    • 2014
  • Purpose: The aim of this study was to evaluate changes of quantitative and semi-quantitative myocardial perfusion indices and image quality by image reconstruction methods in $^{13}N$-ammonia ($^{13}N-NH_3$) myocardial perfusion PET/CT. Materials and Methods: Data of 14 (8 men, 6 women) patients underwent rest and adenosine stress $^{13}N-NH_3$ PET/CT (Biograph TruePoint 40 with TrueV, Siemens) were collected. Listmode scans were acquired for 10 minutes by injecting 370MBq of $^{13}N-NH_3$. Dynamic and static reconstruction was performed by use of FBP, iterative2D (2D), iterative3D (3D) and iterative TrueX (TrueX) algorithm. Coronary flow reserve (CFR) of dynamic reconstruction data, extent(%) and total perfusion deficit (TPD) (%) measured in sum of 4-10 minutes scan were evaluated by comparing with 2D method which was recommended by vendor. The image quality of each reconstructed data was compared and evaluated by five nuclear medicine physicians through a blind test. Results: CFR were lower in TrueX 18.68% (P=0.0002), FBP 4.35% (P=0.1243) and higher in 3D 7.91% (P<0.0001). As semi-quantitative values, extent and TPD of stress were higher in 3D 3.07%p (P=0.001), 2.36%p (P=0.0002), FBP 1.93%p (P=0.4275), 1.57%p (P=0.4595), TrueX 5.43%p (P=0.0003), 3.93%p (P<0.0001). Extent and TPD of rest were lower in FBP 0.86%p (P=0.1953), 0.57%p (P=0.2053) and higher in 3D 3.21%p (P=0.0006), 2.57%p (P=0.0001) and TrueX 5.36%p (P<0.0001), 4.36%p (P<0.0001). Based on the results of the blind test for image resolution and noise from the snapshot, 3D obtained the highest score, followed by 2D, TrueX and FBP. Conclusion: We found that quantitative and semi-quantitative myocardial perfusion values could be under- or over-estimated according to the reconstruction algorithm in $^{13}N-NH_3$ PET/CT. Therefore, proper dynamic and static reconstruction method should be established to provide accurate myocardial perfusion value.

  • PDF

A study of 99mTc-sestamibi labeling condition using radio-chromatography

  • Moon, Sung-Hyun;Lee, Yun-Sang;Lee, Dong Soo;Chung, June-Key;Jeong, Jae Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.1
    • /
    • pp.38-43
    • /
    • 2017
  • Tc-99m labeled sestamibi ($^{99m}Tc$-MIBI) is one of most widely used radiopharmaceuticals for myocardial SPECT imaging. Radiolabeling of $^{99m}Tc$-MIBI is recommended by heating in $100^{\circ}C$ water bath for 15 min. However, the water bath might be a source of contamination. Thus, if radiolabeling of $^{99m}Tc$-sestamibi can be performed at room temperature, then it would be more convenient to use in clinical application. In this study, we performed the radiolabeling of $^{99m}Tc$-MIBI in different temperature conditions or using different instruments to find out the efficient labeling condition. We studied the $^{99m}Tc$-MIBI labeling at room temperature or $100^{\circ}C$ heating block, and checked the labelling yields every 1 min for 10 min using radio-TLC with 2 different eluents-saline and acetone. From the experiment, we confirmed that the $^{99m}Tc$-MIBI can be labeled over 90% yield but not completed at room temperature. However, the $^{99m}Tc$-MIBI labeling was completed when it was performed in the $100^{\circ}C$ heating block. Finally, we proved that heating is essential for complete $^{99m}Tc$-MIBI labelling, furthermore using heating block is also possible instead of water bath.

Endoventricular Circular Patch Plasty (Dor Procedure) for Ischemic Left Ventricular Dysfunction (허혈성 좌심실 부전증에서의 좌심실내 원형 패취성형술)

  • Cho, Kwang-Ree;Lim, Cheong;Choi, Jae-Sung;Hong, Jang-Mee;Kim, Hyeong-Ryul;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.755-761
    • /
    • 2004
  • We evaluated the efficacy of Dor procedure in patients with ischemic left ventricular dysfunction. Material and Method: Between April 1998 and December 2002, 45 patients underwent the Dor procedure con-comitant with coronary artery bypass grafting (CABG). Left ventricular ejection fraction (LVEF) and left ventricular end-diastolic/end-systolic volumes (LVEDV/LVESV) were measured by echocardiography, myocardial SPECT, and cardiac catheterization and angiography performed at the sequence of preoperative, early postoperative, and one year postoperative stage. Result: Cardiopulmonary bypass and aortic clamp times were mean 141$\pm$64, 69$\pm$24 minutes, respectively. Intraaortic balloon pump (IABP) therapy was required in 19 patients (42%; 7 preoperatively, 9 intraoperatively, 3 postoperatively). Operative mortality rate was 2.2% (1/45). Postoperative morbidities were low cardiac output syndrome (12), atrial fibrillation (5), acute renal failure (4), and postoperative bleeding (4). Functional class (NYHA) was improved from classes 2.8 to 1.1 (p < 0,01). When we compared between the preoperative and early postoperative values, LVEF was improved from 32$\pm$9% to 52$\pm$11% (p<0.01). The asynergy portion decreased from 57$\pm$12% to 22$\pm$9%, and LVEDV/LVESV indexes improved from 125$\pm$39 mL/$m^2$, 85$\pm$30 mL/$m^2$ to 66$\pm$23 mL/$m^2$, 32$\pm$16 mL/$m^2$ (p<0.01). Although these changes in volumes were relatively preserved at postoperative one year, the left ventricular volumes showed a tendency to increase. Conclusion: After the Dor procedure for ischemic left ventricular dysfunction, LVEF improvement and left ventricular volume reduction were maintained till postoperative one year. The tendency for left ventricular volume to increase at postoperative one year suggested the requirement of strict medical management.