• 제목/요약/키워드: Mutual structures

검색결과 127건 처리시간 0.026초

상호 구조에 기반한 초점으로부터의 깊이 측정 방법 개선 (Enhancing Depth Measurements in Depth From Focus based on Mutual Structures)

  • 무하마드 타릭 마흐무드;최영규
    • 반도체디스플레이기술학회지
    • /
    • 제21권3호
    • /
    • pp.17-21
    • /
    • 2022
  • A variety of techniques have been proposed in the literature for depth improvement in depth from focus method. Unfortunately, these techniques over-smooth the depth maps over the regions of depth discontinuities. In this paper, we propose a robust technique for improving the depth map by employing a nonconvex smoothness function that preserves the depth edges. In addition, the proposed technique exploits the mutual structures between the depth map and a guidance map. This guidance map is designed by taking the mean of image intensities in the image sequence. The depth map is updated iteratively till the nonconvex objective function converges. Experiments performed on real complex image sequences revealed the effectiveness of the proposed technique.

Computation of the Mutual Radiation Impedance in the Acoustic Transducer Array: A Literature Survey

  • Paeng, Dong-Guk;Bok, Tae-Hoon;Lee, Jong-Kil
    • The Journal of the Acoustical Society of Korea
    • /
    • 제28권2E호
    • /
    • pp.51-59
    • /
    • 2009
  • Mutual radiation impedance becomes more important in the design and analysis of acoustic transducers for higher power, better beam pattern, and wider bandwidth at low frequency sonar systems. This review paper focused on literature survey about the researches of mutual radiation impedance in the acoustic transducer arrays over 60 years. The papers of mutual radiation impedance were summarized in terms of transducer array structures on various baffle geometries such as planar, cylindrical, spherical, conformal, spheroidal, and elliptic cylindrical arrays. Then the computation schemes of solving conventional quadruple integral in the definition of mutual radiation impedance were surveyed including spatial convolution method, which reduces the quadruple integral to a double integral for efficient computation.

領域適應法을 利용한 彈性體 形狀의 最適設計 (Shape optimal design of elastic structures by the domain adaptive method)

  • 정균양
    • 대한기계학회논문집
    • /
    • 제11권2호
    • /
    • pp.234-242
    • /
    • 1987
  • 본 논문에서는 변분법으로 유도한 최적조건을 수치계산에 적용키 위해 영역적 응법이 사용되었으며 불규칙한 형상의 방지에는 격자 적응법이 제시되었다. 설계 문 제로는 '국부 응력치의 일정 한도내에서 구조물 무게의 최소화' 또는 대등한 문제로 '제한된 구조물의 무게한도내에서 최대 국부응력치의 최소화'를 다루었다.

웹의 연결구조로부터 Hub와 Authority를 효과적으로 도출하기 위한 상호강화모델의 확장 (An Extended Mutual Reinforcement Model for Finding Hubs and Authorities from Link Structures on the WWW)

  • 황인수
    • 한국경영과학회지
    • /
    • 제30권2호
    • /
    • pp.1-11
    • /
    • 2005
  • The network structures of a hyperlinked environment can be a rich source of information about the contents of the environment and it provides effective means for understanding it. Recently, there have been a number of algorithms proposed analyzing hypertext link structure so as to determine the best authorities for a given topic or query. In this paper, we review the algorithm of mutual reinforcement relationship for finding hubs and authorities from World Wide Web, and suggest SHA, a new approach for link-structure analysis, which uses the relationships among a set of relative authoritative pages, a set of hub pages, and a set of super hub pages.

Automatic crack detection of dam concrete structures based on deep learning

  • Zongjie Lv;Jinzhang Tian;Yantao Zhu;Yangtao Li
    • Computers and Concrete
    • /
    • 제32권6호
    • /
    • pp.615-623
    • /
    • 2023
  • Crack detection is an essential method to ensure the safety of dam concrete structures. Low-quality crack images of dam concrete structures limit the application of neural network methods in crack detection. This research proposes a modified attentional mechanism model to reduce the disturbance caused by uneven light, shadow, and water spots in crack images. Also, the focal loss function solves the small ratio of crack information. The dataset collects from the network, laboratory and actual inspection dataset of dam concrete structures. This research proposes a novel method for crack detection of dam concrete structures based on the U-Net neural network, namely AF-UNet. A mutual comparison of OTSU, Canny, region growing, DeepLab V3+, SegFormer, U-Net, and AF-UNet (proposed) verified the detection accuracy. A binocular camera detects cracks in the experimental scene. The smallest measurement width of the system is 0.27 mm. The potential goal is to achieve real-time detection and localization of cracks in dam concrete structures.

한국인 성인 남녀의 머리 및 얼굴 부위 측정치 통합분석 (Integrating Analysis on Measurements of Head and Face for Korean Men and Women)

  • 전은경;문지현
    • 한국의류학회지
    • /
    • 제42권6호
    • /
    • pp.988-1001
    • /
    • 2018
  • The head and face are the most complicated structures of the human body. However, unlike apparel products, many of the head and face related products are produced in unisex or one-size-fits-all. Therefore, it is necessary to provide a practical analysis that reflects these size structures. This study analyzed head and face measurements of men, women, and both men and women; its purpose lying in clarifying the differences and commonalities between the measurements of men and women and discovering the possibility of integrating analysis on measurements of men and women. 3D face and head measurement data of men and women from 20 to 29 years-old from Size Korea's 6th human body size data were analyzed for this study. The mutual 9 factors were extracted as the results of the three factor analyses (both men and women) separately and men and women integrated. However in the cluster analysis based on the 9 factors, men and women showed mutual characteristics and different landscape in group types and distribution. The commonalities and differences between men and women observed in this study should be applied to the sizes of head and face products.

Time delay study for semi-active control of coupled adjacent structures using MR damper

  • Katebi, Javad;Zadeh, Samira Mohammady
    • Structural Engineering and Mechanics
    • /
    • 제58권6호
    • /
    • pp.1127-1143
    • /
    • 2016
  • The pounding phenomenon in adjacent structures happens in severing earthquakes that can cause great damages. Connecting neighboring structures with active and semi-active control devices is an effective method to avoid mutual colliding between neighboring buildings. One of the most important issues in control systems is applying online control force. There will be a time delay if the prose of producing control force does not perform on time. This paper proposed a time-delay compensation method in coupled structures control, with semi-active Magnetorheological (MR) damper. This method based on Newmark's integration is adopted to mitigate the time-delay effect. In this study, Lyapunov's direct approach is employed to compute demanded voltage for MR dampers. Using Lyapunov's direct algorithm guarantees the system stability to design a controller based on feedback. Because of the strong nonlinearity of MR dampers, the equation of motion of coupled structures becomes an involved equation, and it is impossible to solve it with the common time step methods. In present paper modified Newmark-Beta integration based on the instantaneous optimal control algorithm, used to solve the involved equation. In this method, the response of a coupled system estimated base on optimal control force. Two MDOF structures with different degrees of freedom are finally considered as a numeric example. The numerical results show, the Newmark compensation is an efficient method to decrease the negative effect of time delay in coupled systems; furthermore, instantaneous optimal control algorithm can estimate the response of structures suitable.

접지그리드의 접지임피던스 측정의 정확도 평가 (Evaluation of the Accuracy of Grounding Impedance Measurement of Grounding Grid)

  • 최종혁;최영철;정동철;김동성;이복희
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.146-153
    • /
    • 2009
  • 최근 대형 건축물들은 접지그리드를 기반으로 한 공통접지방식을 채택하고 있다. 이러한 접지시스템의 성능평가는 접지저항만으로 불충분하므로 접지임피던스의 측정이 요구된다. 대형 접지시스템의 접지임피던스에 대한 측정 방법은 IEEE standard 81.2에 기술되었으나 세부적인 평가방법들은 제시되지 못한 상태이다. 본 논문은 15[m]$\times$15[m] 접지그리드에 대하여 수정된 전위강하법에 기반한 접지임피던스의 정확한 측정방법과 보조전극의 위치에 따른 도전유도 및 전자유도에 의한 측정오차를 기술한다. 그 결과 도전유도에 의한 오차는 보조전극의 거리가 늘어날수록 감소하였다. 전자유도에 의한 오차를 배제하기 위해서 전위측정선은 전류측정선과 90도를 이루어야 한다. 전위측정선과 전류측정선이 예각 또는 둔각을 이루었을 때 전자유도전압은 각각 + 또는 -를 나타내었다. 일반적으로 전자유도에 의한 오차는 예각에 비해서 둔각의 경로가 작게 나타났다.

접지그리드의 접지임피던스 측정 기법 (Measurement method of ground impedance for the grounding grid)

  • 이복희;최종혁;최영철;유재덕;백영환;김동성;신희경;유양우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1487_1488
    • /
    • 2009
  • In these days, the common grounding systems are adapted in most large structures. In order to evaluate the performance of grounding system, it is needed to measure ground impedance. Measuring methods of ground impedance for a large scale grounding systems have not been yet presented in detail. In this paper, we analyze earth mutual resistance and mutual coupling of $15{\times}15m$ grounding grid in different arrangements of auxiliary electrode. As a results, the auxiliary electrodes are installed where the error rate due to earth mutual resistance is less than 5%. Also, the potential lead is installed at obtuse angle from the current lead and the overlapped length between potential lead and grounding grid are minimized.

  • PDF

Experimental Investigations for Thermal Mutual Evaluation in Multi-Chip Modules

  • Ayadi, Moez;Bouguezzi, Sihem;Ghariani, Moez;Neji, Rafik
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1345-1356
    • /
    • 2014
  • The thermal behavior of power modules is an important criterion for the design of cooling systems and optimum thermal structure of these modules. An important consideration for high power and high frequency design is the spacing between semiconductor devices, substrate structure and influence of the boundary condition in the case. This study focuses on the thermal behavior of hybrid power modules to establish a simplified method that allows temperature estimation in different module components without decapsulation. This study resulted in a correction of the junction temperature values estimated from the transient thermal impedance of each component operating alone. The corrections depend on mutual thermal coupling between different chips of the hybrid structure. A new experimental technique for thermal mutual evaluation is presented. Notably, the classic analysis of thermal phenomena in these structures, which was independent of dissipated power magnitude and boundary conditions in the case, is incorrect.