• Title/Summary/Keyword: Muscle, MR

Search Result 73, Processing Time 0.044 seconds

The usefulness of the contrast agent high in gadolinium for the magnetic resonance shoulder arthrography (자기공명 견관절조영검사 시 고함유량 가돌리늄 조영제의 유용성)

  • Na, Sa-Ra;Kim, Yoon-Shin;Choi, Kwan-Woo;Lee, Ho-Beom;Son, Soon-Yong;Min, Jung-Whan;Lee, Joo-Ah;Ma, Sang-Chull;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2199-2206
    • /
    • 2014
  • This research, used an contrast agent, which weighs about 1mmol/mL, of twice as much amount of gadolinum, per unit, for the test of magnetic-resonance shoulder arthrography. the reasearch which was carried out from January, of the year 2012 to August of the year 2013. consisted, of target of 41, patients including 20 ones, of whom an original, contrast agent of amount of 0.5mmol/mL, 21, ones of whom, a new, of amount of 1mmol/mL was used on, were the test target, in order to figure out the differences, according to the amount of gadolinum, according to the test results, the SNR of the contrast agent, of amount of 1mmol/mL, which is of high amount of gadolinum, was noticeably higher than the one of amount of 0.5mmol/mL(the percentage of joint space 38.01%, the supraspinous muscle 8.40%, head of humerus 12.78%). and CNR of the contrast agent, of amount of 1mmol/mL, which is of high amount of gadolinum, was higher than the one of amount of 0.5mmol/mL(the percentage of joint space and supraspinous muscle 48.96%, the one of joint space and head of humerus 42.00%). In conclusion, one of the methods of increasing the reducing effect of T1, is to use contrast agent of amount of 1mmol/mL, in order to increase the reducing effect of T1, acquire the visual of high testing quality.

The usefulness of the contrast agent high in gadolinium for the contrast-enhanced magnetic resonance hip arthrography (고관절의 자기공명관절조영검사 시 가돌리늄 함유량이 높은 조영제의 유용성)

  • Choi, Kwan-Woo;Kim, Yoon-Shin;Son, Soon-Yong;Lee, Ho-Beom;Na, Sa-Ra;Min, Jung-Whan;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5682-5688
    • /
    • 2013
  • The purpose of this study is to maximize diagnositc usefulness with increasing signal to noise ratio(SNR) and contrast to noise ratio(CNR) by using a 1mmol/mL gadolinium contrast agent. From January 2012 to June 2013 fourty-seven patients were underwent the MRI scanning to investigate the contrast difference in gadolinium content. Twenty of the patients were injencted the commercial contrast agent containing 0.5mmol/mL gadolinium and the rest of them were injected the new contrast agent containing 1mmol/mL gadolinium called gadobutrol. We measured and evaluated each SNR and CNR of the hip joint space, iliopsoas muscle and femoral head. As a result, using the 1mmol/mL gadolinium contrast agent had the higher SNR results than using the 0.5mmol/mL agent(27% in the hip joint, 30.01% in the femoral head). Also CNR using the 1mmol/mL gadolinium agent was proved to be higher than that of using 0.5mmol/mL agent(28.31% in the ilopsoas muscle and 26.74% in the femoral head). Therefore, the contrast agent containing more gadolinium like 1mmol/mL used in this study is more effective to shorten T1 relaxation time, so it increases the signal intensity and CNR and furthermore maximizes diagnostic value. This study reports the usefulness of the 1mmol/mL contrast agent in the contrast-enhanced magnetic resonance hip arthrography for the first. Therefore, it can be considered to have an meaningful academic value as showing the method for increasing the diagnostic usefulness by using the 1mmol/mL contrast agent.

In-Vivo Heat Transfer Measurement using Proton Resonance Frequency Method of Magnetic Resonance Imaging (자기 공명영상 시스템의 수소원자 공명 주파수법을 이용한 생체 내 열 전달 관찰)

  • 조지연;조종운;이현용;신운재;은충기;문치웅
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.3
    • /
    • pp.172-180
    • /
    • 2003
  • The purpose of this study is to observe the heat transfer process in in-vivo human muscle based on Proton Resonance Frequency(PRF) method in Magnetic Resonance Imaging(MRI). MRI was obtained to measure the temperature variation according to the heat transfer in phantom and in-vivo human calf muscle. A phantom(2% agarose gel) was used in this experiment. MR temperature measurement was compared with the direct temperature measurement using a T-type thermocouple. After heating agarose gel to more than 5$0^{\circ}C$ in boiling hot water, raw data were acquired every 3 minutes during one hour cooling period for a phantom case. For human study heat was forced to deliver into volunteer's calf muscle using hot pack. Reference data were once acquired before a hot pack emits heat and raw data were acquired every 2 minutes during 30minutes. Acquired raw data were reconstructed to phase-difference images with reference image to observe the temperature change. Phase-difference of the phantom was linearly proportional to the temperature change in the range of 34.2$^{\circ}C$ and 50.2$^{\circ}C$. Temperature resolution was 0.0457 radian /$^{\circ}C$(0.0038 ppm/$^{\circ}C$) in phantom case. In vivo-case, mean phase-difference in near region from the hot pack is smaller than that in far region. Different temperature distribution was observed in proportion to a distance from heat source.

Assessment of Abnormality in Skeletal Muscle Metabolism in Patients with Chronic Lung Desease by $^{31}P$ Magnetic Resonance Spectroscopy ($^{31}P$ 자기 공명분석법을 이용한 만성 폐질환 환자에서의 골격근대사 이상에 관한 연구)

  • Cho, Won-Kyoung;Kim, Dong-Soon;Lim, Tae-Hwan;Lim, Chae-Man;Lee, Sang-De;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.3
    • /
    • pp.583-591
    • /
    • 1997
  • The functional derangement of skeletal muscles which may be attributed to chronic hypoxia has been accepted as a possible mechanism of exercise impairment in patients with chronic obstructive pulmonary disease (COPD). The metabolic changes in skeletal muscle in patients with COPD are characterized by impaired oxidative phosphorylation, early activation of anaerobic glycolysis and excessive lactate and hydrogen ion production with exercise. But the cause of exercise limitation in patients with chronic lung disease without hypoxia has not been known. In order to evaluate the change in the skeletal muscle metabolism as a possible cause of the exercise limitation in chronic lung disease patients without hypoxia, we compared the muscular metabolic data of seven male patients which had been derived from noninvasive $^{31}P$ magnetic resonance spectroscopy(MRS) with those of five age-matched normal male control persons. $^{31}P$ MRS was studied during the sustained isometric contraction of the dominant forearm flexor muscles up to the exhaustion state and the recovery period. Maximal voluntary contraction(MVC) force of the muscle was measured before the isometric exercise, and the 30% of MVC force was constantly loaded to each patient during the isometric exercise. There were no differences of intracellular pH (pHi) and inorganic phosphate/phosphocreatine(Pi/PCr) at baseline, exhaustion state and recovery period between two groups. But pHi during the exercise was lower in patients group than the control group (p < 0.05). Pi/PCr during the exercise did not show significant difference between two groups. These results suggest that the exercise limitation in chronic lung disease patients without hypoxia also could be attributed to the abnormalities in the skeletal muscle metabolism.

  • PDF

Bilateral Extraocular Muscle Metastasis of Nasal Rhabdomyosarcoma Mimicking a Thyroid Associated Orbitopathy: A Case Report (갑상선 안병증으로 오인된 비강 내 횡문근육종의 양쪽 외안근 전이: 증례 보고)

  • Shin, Jin-Ho;Lee, Jeong-Hyun;Lim, Hyun-Kyung;Lee, Ha-Young;Park, Jee-Won;Baek, Hye-Jin;Choi, Young-Jun;Ahn, Jin-He;Baek, Jung-Hwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.2
    • /
    • pp.176-180
    • /
    • 2011
  • Metastases to the orbit usually affect the intraorbital fat and bone than the extraocular muscles. Metastasis to the extracoular muscles commonly occurs unilaterally, and diffuse enlargement of the bilateral extraocular muscles due to metastasis is extremely rare. In this report, we will describe a case of diffuse metastasis to the bilateral extraocular muscles from nasal rhabdomyosarcoma masquerading as thyroid associated orbitopathy. We will also discuss about the MR imaging findings helpful for differential diagnosis from thyroid associated orbitopathy.

Comparison of SUV for PET/MRI and PET/CT (인체 각 부위의 PET/MRI와 PET/CT의 SUV 변화)

  • Kim, Jae Il;Jeon, Jae Hwan;Kim, In Soo;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.10-14
    • /
    • 2013
  • Purpose: Due to developed simultaneous PET/MRI, it has become possible to obtain more anatomical image information better than conventional PET/CT. By the way, in the PET/CT, the linear absorption coefficient is measured by X-ray directly. However in case of PET/MRI, the value is not measured from MRI images directly, but is calculated by dividing as 4 segmentation ${\mu}-map$. Therefore, in this paper, we will evaluate the SUV's difference of attenuation correction PET images from PET/MRI and PET/CT. Materials and Methods: Biograph mCT40 (Siemens, Germany), Biograph mMR were used as a PET/CT, PET/MRI scanner. For a phantom study, we used a solid type $^{68}Ge$ source, and a liquid type $^{18}F$ uniformity phantom. By using VIBE-DIXON sequence of PET/MRI, human anatomical structure was divided into air-lung-fat-soft tissue for attenuation correction coefficient. In case of PET/CT, the hounsfield unit of CT was used. By setting the ROI at five places of each PET phantom images that is corrected attenuation, the maximum SUV was measured, evaluated %diff about PET/CT vs. PET/MRI. In clinical study, the 18 patients who underwent simultaneous PET/CT and PET/MRI was selected and set the ROI at background, lung, liver, brain, muscle, fat, bone from the each attenuation correction PET images, and then evaluated, compared by measuring the maximum SUV. Results: For solid $^{68}Ge$ source, SUV from PET/MRI is measured lower 88.55% compared to PET/CT. In case of liquid $^{18}F$ uniform phantom, SUV of PET/MRI as compared to PET/CT is measured low 70.17%. If the clinical study, the background SUV of PET/MRI is same with PET/CT's and the one of lung was higher 2.51%. However, it is measured lower about 32.50, 40.35, 23.92, 13.92, 5.00% at liver, brain, muscle, fat, femoral head. Conclusion: In the case of a CT image, because there is a linear relationship between 511 keV ${\gamma}-ray$ and linear absorption coefficient of X-ray, it is possible to correct directly the attenuation of 511 keV ${\gamma}-ray$ by creating a ${\mu}$map from the CT image. However, in the case of the MRI, because the MRI signal has no relationship at all with linear absorption coefficient of ${\gamma}-ray$, the anatomical structure of the human body is divided into four segmentations to correct the attenuation of ${\gamma}-rays$. Even a number of protons in a bone is too low to make MRI signal and to localize segmentation of ${\mu}-map$. Therefore, to develope a proper sequence for measuring more accurate attenuation coefficient is indeed necessary in the future PET/MRI.

  • PDF

Solitary Fibrous Tumor of the Ischiorectal Fossa : CT and MRI Findings (좌골직장와에서 기원하는 고립섬유종양: CT, MR 영상소견의 증례 보고)

  • Kim, Ki-Hwan;Cha, Sang-Hoon;Yeom, Suk-Keu;Lee, Seung-Hwa;Chung, Hwan-Hoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.72-76
    • /
    • 2011
  • Solitary fibrous tumor (SFT) is a rare neoplasm, which is usually presented as a pleural based mass, but can also occur in unusual locations based on its mesenchymal origin. However, the radiologic features of SFT occurred in the ischiorectal fossa have been rarely reported. In this case, we describe the MRI findings in a case of a SFT involving the ischiorectal fossa of a 36-year-old man. The tumor appeared as homogeneous iso-signal intensity relative to the adjacent muscle on T1 weighted images, a mixed high signal intensity on the T2 weighted images, and heterogeneous enhancement following the administration of the contrast material.

Musculoskeletal Rehabilitation Exercise Platform for Elderly based on MR (혼합현실 기반의 노인을 위한 근골격계 재활 운동 플랫폼)

  • Sung-Jun Park
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.5
    • /
    • pp.63-70
    • /
    • 2023
  • In this paper, we propose a Mixed Reality based rehabilitation exercise solution with the goal of mitigating one of the most common chronic conditions among the elderly, musculoskeletal disorders. In modern society, as the number of elderly increases, more people engage in office work and engage in more sedentary activities. Due to repetitive work in the office, muscle strength decreases and this causes many difficulties in daily life. In this study, we developed a mixed reality based exercise platform to solve these chronic musculoskeletal diseases. VR is not appropriate for elderly because of dizziness. In addition, we developed a wearable sensor based on IMU and attached it to important parts of the upper body to motion tracking. We developed a algorithm synchronize to raw data from wearable sensor with in a vr avatar. Ederly can check in real time whether rehabilitation exercises are being performed accurately through the avatar.

Laplacian-Regularized Mean Apparent Propagator-MRI in Evaluating Corticospinal Tract Injury in Patients with Brain Glioma

  • Rifeng Jiang;Shaofan Jiang;Shiwei Song;Xiaoqiang Wei;Kaiji Deng;Zhongshuai Zhang;Yunjing Xue
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.759-769
    • /
    • 2021
  • Objective: To evaluate the application of laplacian-regularized mean apparent propagator (MAPL)-MRI to brain glioma-induced corticospinal tract (CST) injury. Materials and Methods: This study included 20 patients with glioma adjacent to the CST pathway who had undergone structural and diffusion MRI. The entire CSTs of the affected and healthy sides were reconstructed, and the peritumoral CSTs were manually segmented. The morphological characteristics of the CST (track number, average length, volume, displacement of the affected CST) were examined and the diffusion parameter values, including fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), radial diffusivity (RD), mean squared displacement (MSD), q-space inverse variance (QIV), return-to-origin probability (RTOP), return-to-axis probabilities (RTAP), and return-to-plane probabilities (RTPP) along the entire and peritumoral CSTs, were calculated. The entire and peritumoral CST characteristics of the affected and healthy sides as well as those relative CST characteristics of the patients with motor weakness and normal motor function were compared. Results: The track number, volume, MD, RD, MSD, QIV, RTAP, RTOP, and RTPP of the entire and peritumoral CSTs changed significantly for the affected side, whereas the AD and FA changed significantly only in the peritumoral CST (p < 0.05). In patients with motor weakness, the relative MSD of the entire CST, QIV of the entire and peritumoral CSTs, and the AD, MD, RD of the peritumoral CST were significantly higher, whereas the RTPP of the entire and peritumoral CSTs and the RTOP of the peritumoral CST were significantly lower than those in patients with normal motor function (p < 0.05 for all). In contrast, no significant changes were found in the CST morphological characteristics, FA, or RTAP (p > 0.05 for all). Conclusion: MAPL-MRI is an effective approach for evaluating microstructural changes after CST injury. Its sensitivity may improve when using the peritumoral CST features.

Quantification of the Elastic Property of Normal Thigh Muscles Using MR Elastography: Our Initial Experience (자기 공명 탄성 검사를 이용한 대퇴 근육의 탄성도의 정량화: 초기 경험)

  • Junghoon Kim;Jeong Ah Ryu;Juhan Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1556-1564
    • /
    • 2021
  • Purpose This study aimed to apply MR elastography (MRE) to achieve in vivo evaluation of the elastic properties of thigh muscles and validate the feasibility of quantifying the elasticity of normal thigh muscles using MRE. Materials and Methods This prospective study included 10 volunteer subjects [mean age, 32.5 years, (range, 23-45 years)] who reported normal activities of daily living and underwent both T2-weighted axial images and MRE of thigh muscles on the same day. A sequence with a motion-encoding gradient was used in the MRE to map the propagating shear waves in the muscle. Elastic properties were quantified as the shear modulus of the following four thigh muscles at rest; the vastus medialis, vastus lateralis, adductor magnus, and biceps femoris. Results The mean shear modulus was 0.98 ± 0.32 kPa and 1.00 ± 0.33 kPa for the vastus medialis, 1.10 ± 0.46 kPa and 1.07 ± 0.43 kPa for the vastus lateralis, 0.91 ± 0.41 kPa and 0.93 ± 0.47 kPa for the adductor magnus, and 0.99 ± 0.37 kPa and 0.94 ± 0.32 kPa for the biceps femoris, with reader 1 and 2, respectively. No significant difference was observed in the shear modulus based on sex (p < 0.05). Aging consistently showed a statistically significant negative correlation (p < 0.05) with the shear modulus of the thigh muscles, except for the vastus medialis (p = 0.194 for reader 1 and p = 0.355 for reader 2). Conclusion MRE is a quantitative technique used to measure the elastic properties of individual muscles with excellent inter-observer agreement. Age was consistently significantly negatively correlated with the shear stiffness of muscles, except for the vastus medialis.