• 제목/요약/키워드: Municipal wastewater treatment plant

검색결과 98건 처리시간 0.037초

능동적 신재생에너지 생산을 통한 하수처리장 에너지자립화 향상 (Improving Energy Self-sufficiency in Municipal Wastewater Treatment Plant using Renewable Energy Production)

  • 강지훈;채규정;김동수;양희정;안영섭;김원경;김정현;박동을
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2012년도 학술발표회
    • /
    • pp.643-643
    • /
    • 2012
  • Increasing energy prices and growing concerns about global warming address the need to improve energy self-sufficiency in many industrial and municipal sectors. Wastewater treatment plants (WWTPs) are representative of energy-consuming facilities in Korea, accounting for 5% of national energy consumption. We present renewable energy technologies and energy self-sufficiency scenarios in a municipal WWTP ($30,000m^3d^{-1}$) located in Yongin, South Korea. By employing photovoltaics (PV, 135 kW), small hydropower turbine (10 kW), and thermal energy from treated effluent (25 RT: refrigeration ton) within the WWTP, a total of 142 tonne of oil equivalent (toe) of energy was estimated to be generated, accounting for $365ton\;CO_2\;yr^{-1}$ of greenhouse gas emission reduction. Core renewable technologies under consideration include 1) hybrid solar PV system consisting of fixed PV, dual-axis PV, and building integrated PV, 2) low-head small hydropower plant specifically designed for treated effluent, 3) effluent heat recovery system for heating and air conditioning. In addition to these core technologies, smart operation and management scheme will be presented for enhancing overall energy savings and distribution within the WWTP.

  • PDF

유기폐자원을 이용한 고도하수처리 대체탄소원 개발 및 실플랜트 적용 (Development of Alternative External Carbon Source from Wasting Carbonaceous Organic Resource and Full Scale Application)

  • 정인철;김호영;강동효;정종순;이상원;임근택;김창원
    • 한국환경과학회지
    • /
    • 제13권10호
    • /
    • pp.911-919
    • /
    • 2004
  • The purpose of this research was evaluated economical effect to apply alternative external carbon source. Conventional activated sludge process in municipal wastewater treatment plant was adapted and introduced to Biological nutrient removal processes to meet the newly enforced effluent quality standard for nutrient removal in Korea. Low $COD/NH_4^+-N$ ratio and higher nutrient concentration of influent characteristics force to inject external carbon source for denitrifying recycled nitrate. In the most case, methanol was used as external carbon source. But Methanol is expensive and very dangerous in handling. So we could find cheaper and safer external carbon source substituted methanol in last study. This alternative external carbon source is named RCS(recoverd carbon source) and a by-product of fine chemical product at chemical plant. When RCS was applied real municipal wastewater treatment plant, average $55\~65\%$ of T-N removal efficiency, 8.8mg/l of effluent T-N concentration, 11.3mg/l of effleunt COD concentration were obtained without effluent COD increase as against used methanol. To apply RCS in municipal wastewater treatment plant obtain approximately $\74.5%$ expenditure cost reduction in comparison with methanol dosage cost.

하수처리장 방류수역에서 분변계스테롤과 노닐페놀류의 분포 특성 (Distribution of Fecal Sterols and Nonylphenolic Compounds in Sediments from Busan Suyeong Estuary, Impacted by Wastewater Treatment Plant Effluents)

  • 백승홍;윤세라;이인석;황동운;최민규
    • 한국수산과학회지
    • /
    • 제47권6호
    • /
    • pp.1006-1013
    • /
    • 2014
  • Wastewater organic compounds, that is, nonylphenolic compounds (NPs) and fecal sterols, were measured in surface sediments from Busan Suyeong Estuary, where two wastewater treatment plants (WWTPs) are located, to assess contamination from municipal effluents. The NPs analyzed were nonylphenol, and nonylphenol mono- and di-ethoxylates, all synthetic endocrine disruptors. The fecal sterols analyzed were coprostanol (COP), cholestanol, and epicoprostanol. Concentrations of NPs in the sediments ranged from 146 to 3,723 ng/g, and those of COP ranged from 366 to 13,018 ng/g. Their detection in all of the sediments analyzed indicates widespread pollution by municipal effluents. The highest concentrations of NPs and COP were detected at stations close to outfalls of WWTPs. Their levels in sediments are categorized in the higher range of those previously reported in Korean coastal areas. Moreover, in comparison with screening values of NPs in the Netherlands, Norway, and Canada, more than 50% of the sampling stations exceeded the guidelines. This indicates that the estuary may be adversely influenced by municipal effluents.

생물막공법을 이용한 도시하수처리에 관한 연구 (A Study on the Municipal Wastewater Treatment Using Biofilm Process)

  • 곽병찬;탁성제;김남천;황용우
    • 상하수도학회지
    • /
    • 제14권1호
    • /
    • pp.62-75
    • /
    • 2000
  • Most of biological treatment to remove contaminants in municipal wastewater have been conducted by activated sludge process. But, the process have several probIems such as enormous site needed for construction of treatment facilities, unstable treatment due to limited ability to control load fluctuation, frequent sludge bulking and appearance of lots of surplus sludge. In this study, the experiments were performed through submerging biofilm of PEPP media in existing aeration tank with raw water from municipal wastewater treatment plant and then submerging PVDC and PEPP media, different from shape and chemical peculiarity in anoxic reactor. Throughout the experience, nutrient removal efficiency according to HRT, nitrogen phosphorous removal efficiency, behavior of nitrogen and dewatering efficiency have been compared and analysed with those of activated sludge process. As the results, BOD removal efficiency according to BOD volumetric load and F/M ratio was not found any differency in two processes, but was decreased below 90% as going along the condition of high load in activated sludge process. Kinetic coefficient was $K_{max}=1.162day^{-1}$, $K_s=53.77mg/L$, $Y=0.166mgVSS/mgBOD_{rem}$. and $K_d=0.019day^{-1}$. It was found that the removal efficiency, even though in aerobic condition, in biofilm process equipped anoxic reactor was higher than the one in activated sludge process within the range of 70~80%, and became better as HRT increased. Phosphorous removal efficiency was not found any differency in two processes. In biofilm process, treament efficiency even in conditions of high load was not decreased, because the biomass concentration could be maintained in high condition compared with activated sludge process. As HRT increased, suspended and attached biomass was increased and the other hand, F/M ratio was decreased as biomass' increasing. Biomass thickness was increased. from $10.43{\mu}m$ to $10.55{\mu}m$ as HRT increased and density of biomass within $40.79{\sim}41.16mg/cm^2$. The results also present that the dewatering efficiency of sludge generated in biofilm process was higher than in activated sludge process, and became better as HRT increased.

  • PDF

Analysis of the Activated Sludge of a Municipal WWTP by Several Bio-Parameters

  • Cho Sun-Ja;Jung Yong-Ju;Park Tae-Joo;Lee Sang-Joon
    • 한국환경과학회지
    • /
    • 제14권9호
    • /
    • pp.811-815
    • /
    • 2005
  • The activated sludge from the aeration basin of the Su-yeong municipal wastewater treatment plant which has operated by a standard activated sludge process in Busan, Korea was investigated during April 2004 and January 2005 with several bio-indicators. The number of bacteria and fungi per gram of dry weight of MLSS were estimated to be $3.1\times10^6\sim1.5\times10^8\;and\;l.1\times10^3\sim1.1\times10^5$ colony forming units, respectively, by the plate agar method. By cultivation-independent methods, such as 4',6-diamidino-2-phenylindole stain and fluorescence in situ hybridization, the ratio of eubacteria to the entire biomass was evaluated by more than $80\%$ (v/v). The ratio of ammonia-oxidizing bacteria and nitrite-oxidizing bacteria to the total eubacteria was detennined to be $7.0\sim9.8\%\;and\;3.3\sim6.2\%$ without heavy variation in spite of a period of relatively low temperature in the basin. It would be expected that the nitrification would occur or at least co-exist throughout the year in the sludge of many municipal WWTP with influents that contain the sufficient nitrogen sources although the WWTP does not have any specialized processes for the removal of nitrogen.

다양한 하수를 대상으로 유기물 성상과 질산화 반응조 내 유기물 변화 (Analysis of COD fraction and change of COD in nitritation reactor using various wastewater)

  • 임지열;길경익
    • 한국습지학회지
    • /
    • 제17권4호
    • /
    • pp.421-427
    • /
    • 2015
  • ASM 모델에서는 유기물을 특성에 따라 분류하는데, 일반적인 COD와 BOD로의 분류로는 ASM에서 요구하는 조건을 충족시키지 못한다. 본 연구에서는 하수종말처리장 수처리 및 슬러지 처리 계통 하수를 대상으로 미생물 호흡률을 기반으로 하여 ASM에서 요구하는 유기물 분류에 대한 실시하였다. 분석 결과 유기물 성상 분석 결과 각 하수마다 유기물 구성에서 차이를 보이는 것으로 나타났다. 이는 각 공정의 하수를 처리할 때 반드시 파악해야 하는 중요한 하수특성이라고 할 수 있다. 따라서 본 연구를 통해 규명한 각 하수별 유기물 성상은 하수종말처리장의 원활한 운영을 위해 중요한 기초 자료로 활용될 수 있을 것으로 판단된다. 질산화 반응조 내 반응시간에 따른 유기물 및 암모니아성 질소 변화 분석을 통해 SS이 질산화에 영향을 미치는 주요 인자임을 확인 할 수 있었다. 이는 질산화 반응이 유도 가능한 체류시간 선정에 밀접한 관계가 있는 것으로 사료된다.

Toxicity characteristics of sewage treatment effluents and potential contribution of micropollutant residuals

  • Kim, Younghee;Farnazo, Danvir Mark
    • Journal of Ecology and Environment
    • /
    • 제41권11호
    • /
    • pp.318-327
    • /
    • 2017
  • Background: A typical sewage treatment plant is designed for organic and nutrient removal from municipal sewage water and not targeted to eliminate micropollutants such as pesticides, pharmaceuticals, and nano-sized metals which become a big concern for sustainable human and ecological system and are mainly discharged from sewage treatment plant. Therefore, despite contaminant removal by wastewater treatment processes, there are still remaining environmental risks by untreated pollutants in STP (sewage treatment plant) effluents. This study performed aquatic toxicity tests of raw wastewater and treated effluents in two sewage treatment plants to evaluate toxicity reduction by wastewater treatment process and analyze concentration of contaminants to reveal potential toxic factors in STP effluents. Methods: Water samples were collected from each treatment steps of two STPs, and acute and chronic toxicity tests were conducted following USEPA (United States Environmental Protection Agency) and OECD (Organization for Economic Cooperation and Development) guidelines. Endpoints were immobility for mortality and reproduction effect for estrogenicity. Results: Acute $EC_{50}s$ (median effective concentration) of influents for Seungki (SK) and Jungnang (JN) STPs are $54.13{\pm}32.64%$ and $30.38{\pm}24.96%$, respectively, and reduced to $96.49{\pm}7.84%$ and 100%. Acute toxicity reduction was clearly correlated with SS (suspended solids) concentration because of filter feeding characteristics of test organisms. Chronic toxicity tests revealed that lethal effect was reduced and low concentration of influents showed higher number of neonates. However, toxicity reduction was not related to nutrient removal. Fecundity effect positively increased in treated wastewater compared to that in raw wastewater, and no significant differences were observed compared to the control group in JN final effluent implying potential effects of estrogenic compounds in the STP effluents. Conclusions: Conventional wastewater treatment process reduced some organics and nutritional compounds from wastewater, and it results in toxicity reduction in lethal effect and positive reproductive effect but not showing correlation. Unknown estrogenic compounds could be a reason causing the increase of brood size. This study suggests that pharmaceutical residues and nanoparticles in STP effluents are one of the major micropollutants and underline as one of estrogenic effect factors.

국내 하수처리장 관리대행 현황 및 제도 개선 방안 (The Investigation and Improvement plan of Contracting-out municipal wastewater treatment plant system in Korea)

  • 임지열;길경익
    • 한국습지학회지
    • /
    • 제19권2호
    • /
    • pp.211-215
    • /
    • 2017
  • 하수처리장 운영 시장 규모는 전세계적으로 증가하고 있는 추세이다. 이에 하수처리장 관리 대행 제도는 국내 하수처리장의 효율적인 운영을 위해 도입되었지만 지속적으로 개선의 필요성이 제기되고 있다. 본 연구에서는 하수처리장 관리 제도의 활성화를 위해 현행 하수처리장 운영비용 현황 조사 및 개선 방안을 연구하였다. 하수처리장 용량이 클수록 하수처리단가가 감소하는 하는 경향을 보였다. 전체 하수처리장 운영 단가는 공기업이 가장 저렴하였지만, 유사 하수 처리장(유사 용량, 유사 공법, 유사 운영 기간)의 운영비용을 비교하였을 경우 민간 기업이 가장 저렴한 것으로 나타났다. 하수처리장 관리 및 운영 관계자들과의 면담 조사 결과 관리대행업자 선정 및 운영 비용 산정 방법 개선이 필요하다는 의견이 제시되었다. 본 연구는 하수처리장 관리 대행 활성화를 위한 방안 제시를 위한 기초 자료로 활용 될 수 있을 것으로 판단한다.