• Title/Summary/Keyword: Municipal solid

Search Result 325, Processing Time 0.026 seconds

The Characteristics and Heating Values Analysis of Municipal Solid Wastes according (쓰레기종량제에 따른 쓰레기의 특성 및 발열양 분석)

  • 문추조;정순형;이태호
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.3
    • /
    • pp.29-34
    • /
    • 1995
  • This study was on the characteristics and heating values analysis of municipal solid wastes according to the volume- rate garbage collection system in Busan. Each waste sample was analyzed to obtain physical composition, proximate analysis, heating value, chemical composition. And the heating value were compared with those of the past waste collection system. The average physical composition of A.P.T. area was food waste 54.0~65.7% , while that of common residence was food waste 57.9~61.2% . The density of solid waste were largely different for site and the highest densities of waste was $399.6kg/m^{3}$ from Market. The low heating value of waste from residence site was 996.9kca1/kg~1, 238.1 kcal/kg which was lower than 1, 000kcal/kg~1, 800kca1/kg of the past wastes. These difference was mainly due to the difference of moisture content and the amount of vegetables.

  • PDF

Operational and Performance parameters of Anaerobic Digestion of Municipal Solid Waste (도시쓰레기 혐기성소화 운용 및 성능 지표)

  • Chung, Jae-Chun;Park, Chan-Hyuk;Son, Sung-Myung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.10 no.4
    • /
    • pp.86-95
    • /
    • 2002
  • Anaerobic digestion of municipal solid waste(MSW) is recently getting attention due to energy generation and abatement of global warming. MSW has high solid content and low nitrogen content. Its major component is cellulose and hemicellulose. The conversion rate of organic portion of MSW to methane is approximately 50%, representing $0.2m^3/kg$ VS. Long hydraulic retention time is required for high solid content and inoculum should be mixed with the feed. When MSW is digested anaerobically, maximum limit of C/N ratio is 25 and the optimum concentration of $NH_3-N$ is 700mg/L. lime and sodium bicarbonate are used to adjust pH. Excess addition of sodium bicarbonate above 3,500mg/L will cause sodium toxicity. Thermophilic anaerobic digestion is effective in the control of pathogen although its operation and maintenance is difficult. To optimize the anaerobic digestion of MSW, it is necessary to understand the mechanism of microorganims involved in anaerobic digestion.

  • PDF

A Study on the Application of Temperature Feedback Aeration Method for Composting of Municipal Solid Wastes (효율적 퇴비화를 위한 온도제어 공기공급방식의 적용에 관한 연구)

  • Kim, Byung-Tae;Kim, Jung-Wk
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.2 no.1
    • /
    • pp.3-18
    • /
    • 1994
  • Municipal solid wastes in Korea have physical and chemical properties suitable for composting, but composting has had little practical use in solid waste disposal until now because of a lack of understanding of process control. For practical use of composting, process control must be capable of maintaining good product quality while large quantities are composted in a short period of time. Ventilation control to maintain optimum temperature(Temperature Feedback Aeration Method) is reported to be convenient to operate. The purpose of this study is to analyze process efficiency and optimum temperature in the temperature feedback aeration method for composting of municipal solid wastes. The results of this study show that degradation and drying of substrate in the temperature feedback aeration method are higher than those in the constant aeration method. And the optimum temperature range for composting of solid wastes appears to be $50{\sim}54^{\circ}C$.

  • PDF

Characteristics of Stabilization of Excavated Solid Wastes by Aerobic and Anaerobic Landfilling (호기 및 혐기매립에 의한 굴착폐기물의 안정화 특성 연구)

  • Park, Jin-Kyu;Oh, Dong Ik;Lee, Nam-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.3
    • /
    • pp.76-85
    • /
    • 2004
  • Anaerobic decomposition of municipal solid waste (MSW) had potential adverse impacts such as the production of methane and long-term post closure on human health and the environment. It was demonstrated that aerobic degradation of MSW resulted in the reduction of a methane yield and the enhancement of stabilization of MSW. Excavated solid wastes were both aerobically and anaerobically treated in order to evaluate the effects of air injection on the stabilization of landfill site. The municipal solid waste (MSW) samples were excavated from a 10-year old landfill (operation period: 1991. 11~1994. 11), Jeonju, Korea. Excavated municipal solid wastes are primarily composed of soils and vinyl/plastics. For the two aerobic simulated lysimeters, the levels of $O_2$ ranged 1.6~23.1% and the levels of $CO_2$ ranged 1.5~15.1%, which confirmed the aerobic decomposition. Aeration did prevent methane formation. For the anaerobic simulated lysimeter, the $CO_2$ rose as $O_2$ was consumed and low levels of CH4 were produced. The pH levels ranged from 7.7 to 8.9 for anaerobic lysimeter and from 7.3 to 8.5 for aerobic lysimeters. As expected, aerobic treatment proved to enhance the removal of biodegradable materials in the excavated solid wastes when monitoring the concentration of BOD, COD, $NH_4-N$, and $NO_3-N$ in the leachate.

  • PDF

Effects of Landfill Leachate on the Treatment of Municipal Wastewater (매립지 침출수가 도시하수처리에 미치는 영향)

  • Jang, Ji-Hee;Kim, Yeong-Kwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.2
    • /
    • pp.117-123
    • /
    • 1996
  • A bench-scale continuous activated sludge system was operated in order to study the effects of solid waste landfill leachate on municipal wastewater treatment. The leachate sample was collected from Nanjido landfill. During the 7 weeks of operational period, the leachate content in the influent fed to the system was increased stepwise from 3% to 5% and 7%. The solids retention time was the major process control parameter, and it was 10 days. With the municipal wastewater alone, COD removal was 75%. The removal percents, however, decreased to 60% and 45% when the leachate content was 3% and 7%, respectively. For the wastewater spiked with the leachate, the sludge production was higher than for the municipal wastewater alone. Sludge settleability determined by SVI deteriorated with the increase of leachate content. The specific oxygen uptake rate, however, was measured higher as leachate content increased.

  • PDF

Removal of Chlorine from Fly Ash in Municipal Solid Waste Incineration Ash by Water Washing (수세에 의한 생활폐기물 소각재 중 비산재로부터 염소성분의 제거)

  • 안지환;한기천;김형석
    • Resources Recycling
    • /
    • v.10 no.5
    • /
    • pp.36-43
    • /
    • 2001
  • The chlorine component in fly ash from municipal solid waste incineration ash was removed by water washing for the purpose of recycling fly ash as a raw material of ordinary portland cement. The samples were a different kind of 리y ashes using $Ca(OH)_2$and NaOH as media of wet scrubber for flue gas cleaning. The content of soluble salts of fly ash using $Ca(OH)_2$and NaOH was 32.8%, 50.1% and the content of chlorine component, 22.9% and 26.0% respectively, which was KCl, NaCl, CaC1OH mainly. When each fly ash was washed using water under conditions of a agitation speed of 300 rpm, a liquid to solid ratio of 10, most soluble salts in fly ash were dissolved within 30 minutes and the content of chlorine component in ash was diminished to the content of 4.4%, 2.O% at $20^{\circ}C$ and 1.7%, 0.8% at $50^{\circ}C$ respectively. And the main compound of residual chlorine component in ash after water washing was friedel`s salt ($3CaO.A1_2$$O_3$.$CaCl_2$.$10H2$O). From analysis results of water quality for wastewater by water washing, the components exceeding discharged wastewater standard were only Pb and Cd. But As pH was controlled to 10 with addition of $CO_2$(g) or $Na_2$$_CO3$in water, the concentration of heavy metals such as Pb and Cd was also under discharged wastewater standard.

  • PDF

The Study of Physico-chemcal Characteristics of Municipal Solid Waste (MSW) in Gangwon Area (강원지역 도시폐기물의 물리·화학적 특성 연구)

  • Lee, Keon-Joo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.2
    • /
    • pp.101-111
    • /
    • 2009
  • In this study, the physico-chemical characteristics of municipal solid waste (MWS) which was treated in gangwon area were investigated. It is necessary to measure the characteristics of municipal solid waste for build a waste treatment and RDF facility and for data-base and total managing of the landfill. It was found that the average density of solid wastes is in the range of $101.8{\sim}199.8kg/m^3$. This MSW was composed of 30.7% of food wastes, 36.3% of papers, 15.8% of plastics & vinyls, 1.9% of textiles, 3.2% of wood and 1.5% of rubber & leathers respectively. Most of MSW are composed of food, paper and plastic waste and the combustible waste is more than 90%. For three components, moisture is 44.6%, combustible component is 47.7% and ash is 7.7% respectively. The chemical elements are carbon, oxygen, and hydrogen on the dry basis of wastes. The low heating value of the MSW measured by calorimeter was obtained as 2,631 kcal/kg, and the high heating value of the MSW was obtained as 3,310 kcal/kg.

  • PDF

A Novel Treatment Method for the Wastes of Unsanitary Landfill at the Residential Development Site (택지개발 현장 내 비위생매립지의 매립쓰레기 처리방안 연구)

  • Son, Young-Gyu;Park, Beom-Guk;Lim, Myung-Hee;Kim, Won-Jang;Khim, Jee-Hyeong
    • Journal of Environmental Science International
    • /
    • v.17 no.2
    • /
    • pp.177-183
    • /
    • 2008
  • Characteristic of wastes in a unsanitary landfill at the residential development site in H city, Kyunggi-do was investigated for the disposal of huge amount of wastes. The total amount of wastes was estimated at 117,000 ton and construction solid wastes and municipal solid wastes were detected together. The portion of combustibles was very low and soils, concrete wastes, and pebbles were the major components in landfilled wastes. Because the site was the residential development site, the landfilled wastes should be removed immediately for the construction. Therefore the way that the unsanitary landfill was excavated and the wastes were sorted into three categories such as soils, noncombustibles and combustibles was selected as the best method. Soils and noncombustibles could be recycled and sorted combustibles could be re-landfilled in a smaller area or incinerated.

Biodrying of municipal solid waste under different ventilation periods

  • Ab Jalil, N.A.;Basri, H.;Basri, N.E. Ahmad;Abushammala, Mohammed F.M.
    • Environmental Engineering Research
    • /
    • v.21 no.2
    • /
    • pp.145-151
    • /
    • 2016
  • Biodrying is a pre-treatment method that applies biological and mechanical concepts to drying solid waste. In Malaysia, municipal solid waste (MSW) is unseparated and contains a high level of moisture, making the use of technology such as solid waste burning unsuitable and harmful. MSW containing organic material can be processed naturally until the moisture content of the waste is reduced. This study on MSW biodrying was carried out on a laboratory scale to measure the percent moisture content reduction and to monitor temperature patterns under different ventilation periods. This work was conducted using five biodrying reactors volumes of 50 liters each. Reactors were ventilated for 5, 10, 15, 20 and 30 min every 3 h, with a 3 bar air supply. The duration of this process was 14 days for all samples. The results showed that the optimum ventilation time was 10 min, with an 81.84% reduction in moisture content, and that it required almost half of the electricity cost required for the 20 and 30 min ventilations.