• Title/Summary/Keyword: Multiple zone

Search Result 357, Processing Time 0.028 seconds

Genetic Analysis of Some Polymorphic Isozymes in Pinus densiflora(II) - Inheritance of acid phosphatase, alcohol dehydrogenase and catalase isozymes - (소나무의 몇가지 다형적(多形的) 동위효소(同位酵素)의 유전분석(遺傳分析)(II) - Acid phosphatase, alcohol dehydrogenase와 catalase 동위효소(同位酵素)의 유전양식(遺傳樣式) -)

  • Kim, Z.S.;Hong, Y.P.
    • Journal of Korean Society of Forest Science
    • /
    • v.68 no.1
    • /
    • pp.32-36
    • /
    • 1985
  • Megagametophyte tissues of Pinus densiflora were subjected to study the inheritance of acid phosphatase (ACP), alcohol dehydrogenase (ADH) and catalase (CAT) isozymes by starch gel zone-electrophoresis. At least three or four zones were segregated for ACP isozyme. However, as one isozyme of ACP-A zone was separated clearly, only that isozyme was analysed. Five isozyme phenotypes (A1-A5), observed in ACP-A zone, were segregated to a simple Mendelian ratio, suggesting that these are controlled by five codominant alleles existed at ACP-A locus. Two zones of activity were segregated in the gels after staining for ADH, the more anodal zone (ADH-A) of the two was invariant in our materials. Three isozyme phenotypes (B1-B3) were observed in ADH-B zone and these variants showed a 1:1 segregation pattern, suggesting that each variant is controlled by three codominant alleles at ADH-B locus. A total of five isozyme phenotypes, composed of multiple bands, were observed in CAT isozyme. The segregation of these phenotypes in heterozygous trees did not show any significant deviation from a 1:1 segregation. Therefore, the genetic control of CAT isozyme in Pinus densiflora seeds seems to be based on a single locus (CAT-A) with Five codominant alleles ($A_1-A_5$).

  • PDF

A Report for the Quaternary Gaegok 6 Fault Developed in the Mid-eastern Part of Ulsan Fault Zone, Korea (울산단층대 중동부에 발달하는 제4기 개곡 6단층에 대한 보고)

  • Ryoo, Chung-Ryul
    • Economic and Environmental Geology
    • /
    • v.42 no.6
    • /
    • pp.635-643
    • /
    • 2009
  • In this paper, a Quaternary fault is described, which is developed in the mid-eastern part of Ulsan Fault Zone, near the southern Gaegok-ri, Oedong-eub, Gyeongju, Korea. The Gaegok 6 fault is developed along the contact between Early Tertiary granite and Quaternary gravel deposit overlying unconformably the granite. The fault strikes $N02^{\circ}{\sim}22^{\circ}E$ and dips $45^{\circ}{\sim}80^{\circ}$ to the west. This fault has a 30~50 cm wide cataclastic shear zone with gouge zone, mixed with Quaternary sediments and fault breccia of granite. In the main Quaternary fault plane, the orientation of striation is $17^{\circ}$, $356^{\circ}$, indicating a dextral strike-slip faulting with some normal component. There is another striation ($78^{\circ}$, $278^{\circ}$ and $43^{\circ}$, $270^{\circ}$) with reverse-slip sense, developed on the subsidiary plane which cuts the main Quaternary fault plane. In brief, the fault has been developed between the granite in the western part and the Quaternary gravel deposit in the eastern part. The western block of fault is uplifted. The striations and movement senses of faults indicate multiple compressional stages in this region. The fault has a similar orientation, westward dipping geometric pattern, and reverse sensed kinematic pattern with Gaegok 1 fault developed in the north. Thus, the Gaegok 6 fault is probably a southern extension of Gaegok 1 fault.

Assessment of Steam Generator Tubes with Multiple Axial Through-Wall Cracks (축방향 다중관통균열이 존재하는 증기발생기 세관 평가법)

  • Moon, Seong-In;Chang, Yoon-Suk;Kim, Young-Jin;Lee, Jin-Ho;Song, Myung-Ho;Choi, Young-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.11
    • /
    • pp.1741-1751
    • /
    • 2004
  • It is commonly requested that the steam generator tubes wall-thinned in excess of 40% should be plugged. However, the plugging criterion is known to be too conservative for some locations and types of defects and its application is limited to a single crack in spite of the fact that the occurrence of multiple through-wall cracks is more common in general. The objective of this research is to propose the optimum failure prediction models for two adjacent through-wall cracks in steam generator tubes. The conservatism of the present plugging criteria was reviewed using the existing failure prediction models for a single crack, and six new failure prediction models for multiple through-wall cracks have been introduced. Then, in order to determine the optimum ones among these new local or global failure prediction models, a series of plastic collapse tests and corresponding finite element analyses for two adjacent through-wall cracks in thin plate were carried out. Thereby, the reaction force model, plastic zone contact model and COD (Crack-Opening Displacement) base model were selected as the optimum ones for assessment of steam generator tubes with multiple through-wall cracks. The selected optimum failure prediction models, finally, were used to estimate the coalescence pressure of two adjacent through-wall cracks in steam generator tubes.

Correlation Analysis between Weight Ratio and Shear Strength of Fault Materials using Multiple Regression Analysis (다중회귀분석을 이용한 단층물질의 무게비와 전단강도의 상관성 분석)

  • Moon, Seong-Woo;Yun, Hyun-Soek;Kim, Woo-Seok;Na, Jong-Hwa;Kim, Chang-Yong;Seo, Yong-Seok
    • The Journal of Engineering Geology
    • /
    • v.24 no.3
    • /
    • pp.397-409
    • /
    • 2014
  • The appearance of faults during tunnel construction is often difficult to predict in terms of strike, dip, scale, and strength, even though this information is essential in determining the strength of the surrounding rock mass. However, the strength and rock mass classification of fault zones are generally determined empirically on the construction site. In this study, 109 specimens were collected from fault of nine area throughout Korea, and direct shear tests were conducted and the particle distribution was analyzed to better characterize the fault zones. Six multiple regression models were established, using 97 of the specimens, to analyze the correlation between the shear strengths and weight rations of these fault materials. A verification of the six models, using the remaining 12 specimens, shows that in all of the models the coefficient of determination yielded $R^2{\geq}0.60$, with two models yielding $R^2{\geq}0.69$. These results provide useful information for determining the shear strength of fault materials in future studies.

A Study on the Methods of Multiple Sight Surface and Cumulative Visibility Analysis for the Forest Scape Management around the Myeong-hwal Fortress (명활산성 주변의 산림경관 관리를 위한 시곡면(示曲面)과 누적가시도(累積可視度)분석기법 연구)

  • Kim, Choong-Sik;Lee, Jae-Yong;Kim, Young-Mo
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.29 no.4
    • /
    • pp.78-86
    • /
    • 2011
  • The recovering of historical mountain fortress needs the maintenance of forest scape for achieving visibility. In the study, the methods for the maintenance of the forest around the fortress were proposed. The Cumulative Visibility Analysis and Multiple Sight Surface Analysis were tested to verify the methods using GIS on the Myeong-hwal Fortress in Kyungju. The results of the study are as follows. First, the Cumulative Visibility Analysis was made on the Myeong-hwal Fortress from surrounding major viewpoints. The Cumulative Visibility Analysis enables the selection of excellent visibility sectors on the fortress. The 6 excellent visibility sectors were 1,937m(which occupied 41.2% of the area). Second, two cases of pine tree height were compared in the Cumulative Visibility Analysis. One used the average height of pines and the other used the maximum growth height. The comparative result demonstrated that the case of average height would be more effective for deciding the pine removal zone as well as achieving visibility to the mountain fortress. Third, to examine the feasibility of the management method, the tree removal plan and removal execution were compared on the A zone which showed high visibility frequency. Asa comparative result, there was insignificant difference(3.3%) in area between the tree removal plan($10,935m^2$) and removal execution($11,296m^2$). This study proved the Cumulative Visibility Analysis and Multiple Sight Surface Analysis to be effective for forest scape maintenance around a mountain fortress.

Performance Analysis of FSA Algorithm for Tag Identification in RFID Systems (RFID 시스템에서 태그 식별을 위한 SFSA 알고리즘의 성능 분석)

  • Lim, In-Taek;Choi, Jin-Oh;Choi, Jin-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.563-566
    • /
    • 2008
  • In RFID system. when a variety of tags are present in the interrogation zone of a single reader at the same time, the system requires a multiple tag identification scheme that allows the reader to read data from the individual tags. Anti-collision algorithms required for the multiple tag identification are essential for the implementation of RFID system. This paper analyzed the performance of SFSA algorithm, which is easy to implement. According to the analytical results, the algorithm's performances are closely related with the number of tags and the frame size.

  • PDF

A Study On the Friction Torque and Temperature Distribution of Magnetic Fluid Seals (자성유체시일의 마찰토크와 온도분포 해석에 관한 연구)

  • Kim, Chung-Kyun;Kim, Han-Goo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.1
    • /
    • pp.53-61
    • /
    • 1997
  • The performance characteristics of magnetic fluid seals are studied numerically as a function of working gap, pole width, angle of pole sharpening, and shaft speed. The temperature distribution of a magnetic fluid seal with multiple tooth is investigated as a function of the contact fraction of magnetic fluids at the periphery of pole tooth using a finite element method. The most significant design parameter of a magnetic fluid seal is the working gap between the pole pieces and the rotating shaft. The result shows that with increasing the working gap, the friction torque decreases radically. The practical working gap for the pole pieces with triangular tooth zone profile is 0.2-0.4mm. The FEM results indicate that the optimal filling of a magnetic fluid between the pole pieces and the shaft is very important due to the accumulations of nonuniform friction heating within the pole pieces, which may interfere the magnetic circuit flow.

Economic Dispatch Algorithm as Combinatorial Optimization Problems (조합최적화문제로 접근한 경제급전 알고리즘 개발)

  • Min, Kyung-Il;Lee, Su-Won;Choi, In-Kyu;Moon, Young-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1485-1495
    • /
    • 2009
  • This paper presents a novel approach to economic dispatch (ED) with nonconvex fuel cost function as combinatorial optimization problems (COP) while most of the conventional researches have been developed as function optimization problems (FOP). One nonconvex fuel cost function can be divided into several convex fuel cost functions, and each convex function can be regarded as a generation type (G-type). In that case, ED with nonconvex fuel cost function can be considered as COP finding the best case among all feasible combinations of G-types. In this paper, a genetic algorithm is applied to solve the COP, and the ${\lambda}-P$ function method is used to calculate ED for the fitness function of GA. The ${\lambda}-P$ function method is reviewed briefly and the GA procedure for COP is explained in detail. This paper deals with two kinds of ED problems, namely ED with multiple fuel units (EDMF) and ED with prohibited operating zones (EDPOZ). The proposed method is tested for all the ED problems, and the test results show an improvement in solution cost compared to the results obtained from conventional algorithms.

The Effect of Swirl on the Blowout Velocities of Partially Premixed Interacting Flames (스월이 부분예혼합 상호작용화염의 화염날림 유속에 미치는 영향)

  • Lee, Byeong-Jun;Choi, Kwang-Deok
    • Journal of the Korean Society of Combustion
    • /
    • v.14 no.2
    • /
    • pp.26-31
    • /
    • 2009
  • Adding small amounts of air to the fuel is used in many commercial combustors to avoid sooty flame. But partially premixed jet flame has lower blowout velocity, $u_{b.o}$, than nonpremixed one. Increasing blowout limit would be one of the key factors to develope highly intense compact combustion devices. Swirling flow enhances fuel and air mixing and induces a highly turbulent recirculation zone, which helps flame stabilization. It was known that NOx emission decreases with swirl on the proper range of swirl number. And it was shown that the flame interaction in multiple jets also increases $u_{b.o}$ owing to the internal recirculation and reduces NO emission. If the effects of swirl and flame interaction are combined together in partially premixed flame, both $u_{b.o}$ increasement and NOx emission reduction could be achieved. Blowout limits of partially premixed interacting propane flame in the swirling air coflow are investigated experimentally. The results show that the flame is not extinguished up to the experimental limits, 210 m/s, at the swirl number of 0.32 and $X_{F,o}$ = 0.46.

  • PDF

Evaluation of Plastic Collapse Behavior for Multiple Cracked Structures (다중균열 구조물의 소성붕괴거동 평가)

  • Moon, Seong-In;Chang, Yoon-Suk;Kim, Young-Jin;Lee, Jin-Ho;Song, Myung-Ho;Choi, Young-Hwan;Hwang, Seong-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.11
    • /
    • pp.1813-1821
    • /
    • 2004
  • Until now, the 40% of wall thickness criterion, which is generally used for the plugging of steam generator tubes, has been applied only to a single cracked geometry. In the previous study by the authors, a total number of 9 local failure prediction models were introduced to estimate the coalescence load of two collinear through-wall cracks and, then, the reaction force model and plastic zone contact model were selected as the optimum ones. The objective of this study is to estimate the coalescence load of two collinear through-wall cracks in steam generator tube by using the optimum local failure prediction models. In order to investigate the applicability of the optimum local failure prediction models, a series of plastic collapse tests and corresponding finite element analyses for two collinear through-wall cracks in steam generator tube were carried out. Thereby, the applicability of the optimum local failure prediction models was verified and, finally, a coalescence evaluation diagram which can be used to determine whether the adjacent cracks detected by NDE coalesce or not has been developed.