• Title/Summary/Keyword: Multiple Vibration Control

Search Result 168, Processing Time 0.026 seconds

지능구조물의 능동진동제어를 위한 다중 PPF 제어기와 수정 LQG 제어기의 비교 연구 (Comparison of the Multiple PPF Control and the Modified LQG Control for the Active Vibration Suppression of Intelligent Structures)

  • 곽문규
    • 소음진동
    • /
    • 제8권6호
    • /
    • pp.1121-1129
    • /
    • 1998
  • This research is concerned with the multiple PPF and the modified LQG controller design for active vibration control of intelligent structures. The intelligent structure is defined as the structure equipped with smart actuators and sensors. Various control techniques aimed for the piezoceramic sensors and actuators have been proposed for the active vibration control of smart structures and some of them prove their effectiveness experimentally. In this paper, the multiple PPF controller and the modified LQG controller are developed and applied to the smart grid structure. The multiple PPF control and the modified LQG control can be classified as the classical and the modern control techniques. respectively. The experimental results show that both control techniques are effective in suppressing vibrations. Two control techniques are compared with respect to the design process. the ease of implementation and the effectiveness

  • PDF

양팔 협조 유연 매니퓰레이터의 진동억제 제어 (Vibration Suppression Control of Two Cooperating Flexible Manipulators)

  • 김진수
    • 한국생산제조학회지
    • /
    • 제19권5호
    • /
    • pp.645-652
    • /
    • 2010
  • For free motions, vibration suppression of single flexible manipulators has been one of the hottest research topics. However, for cooperative motions of multiple flexible manipulators, a little effort has been devoted for the vibration suppression control. So, the aim of this paper is to develop a hybrid force/position control and vibration suppression control scheme for multiple cooperation flexible manipulators handling a rigid object. In order to clarify the discussion, the motions of dual-arm experimental flexible manipulator are considered. Using the developed model, we control a robotic system with hybrid position/force control scheme. Finally, Experiments are performed, and a comparison of experimental results is given to clarify the validity of our control scheme.

Multiple model switching adaptive control for vibration control of cantilever beam with varying load using MFC actuators and sensors

  • Gao, Zhiyuan;Huang, Jiaqi;Miao, Zhonghua;Zhu, Xiaojin
    • Smart Structures and Systems
    • /
    • 제25권5호
    • /
    • pp.559-567
    • /
    • 2020
  • Vibration at the tip of various flexible manipulators may affect their operation accuracy and work efficiency. To suppress such vibrations, the feasibility of using MFC actuators and sensors is investigated in this paper. Considering the convergence of the famous filtered-x least mean square (FXLMS) algorithm could not be guaranteed while it is employed for vibration suppression of plants with varying secondary path, this paper proposes a new multiple model switching adaptive control algorithm to implement the real time active vibration suppression tests with a new multiple switching strategy. The new switching strategy is based on a cost function with reconstructed error signal and disturbance signal instead of the error signal from the error sensor. And from a robustness perspective, a new variable step-size sign algorithm (VSSA) based FXLMS algorithm is proposed to improve the convergence rate. A cantilever beam with varying tip mass is employed as flexible manipulator model. MFC layers are attached on both sides of it as sensors and actuators. A co-simulation platform was built using ADAMS and MATLAB to test the feasibility of the proposed algorithms. And an experimental platform was constructed to verify the effectiveness of MFC actuators and sensors and the real-time vibration control performance. Simulation and experiment results show that the proposed FXLMS algorithm based multiple model adaptive control approach has good convergence performance under varying load conditions for the flexible cantilever beam, and the proposed FX-VSSA-LMS algorithm based multiple model adaptive control algorithm has the best vibration suppression performance.

피에조 세라믹을 이용한 유연한 평판의 능동진동제어 (Active Vibration Control of Flexible Plate using Piezo Ceramic)

  • 박수홍;김홍섭;홍진석;오재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.434-439
    • /
    • 1997
  • This paper presents the active control of a flexible plate vibration. The plate was excited by white noise point force and the control was performed by one or two piezo ceramic actuator bonded to the surface of the plate. An adaptive controller based on filtered-x or multiple filtered-x LMS algorithm was used and the controller was defined by minimizing the square of the response of error sensor. In the experiment, PZT sensor was used as an error sensor while white noise was applied as a disturbance. In the case of multiple channel control, more than 22 dB of vibration reduction was achieved. Results indicate that the vibration of a flexible plate could be controlled effectively when the piezo ceramic actuator was used with multiple filtered-x LMS algorithm.

  • PDF

Active Control of Road-Booming-Noise with Constraint Multiple Filtered-X LMS Algorithm

  • Oh, Shi-Hwan;Kim, Hyoun-Suk;Park, Young-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • 제19권2E호
    • /
    • pp.3-7
    • /
    • 2000
  • Vibration generated by the non-uniform road profile propagates though each tire and the suspension and finally generates structure born noise in the interior of the passenger vehicle. In this paper, the road-booming-noise which has strong correlation with the vibration signals measured at the suspension system was compensated. Active noise control of the road-booming-noise is rather difficult to achieve because of its non-stationary characteristics. CMFX LMS (Constraint Multiple Filtered-X Least Mean Square) algorithm, which can track non-stationary process rather well, is applied. Comprison of the proposed method and the conventional MFX LMS (Multiple Filtered-X Least Mean Square) algorithm is made through the hardware-in-the-loop simulation and the feasibility of the proposed method is demonstrated with the experiment.

  • PDF

다중 동흡진기를 이용한 장력구배를 갖는 박판의 진동 제어 (Vibration Control of Membrane with Tension Gradient Using Multiple Dynamic Absorber)

  • 박종현;김성대;김원진
    • 한국소음진동공학회논문집
    • /
    • 제15권5호
    • /
    • pp.595-603
    • /
    • 2005
  • In this work, the multiple dynamic absorber( MDA ) is introduced to reduce several vibration modes of shadow mask simultaneously and its design method is developed from the theory of the simple dynamic absorber. When designing the dynamic absorber, there are three significant design parameters such as mass, damping ratio and tuning frequency. Therefore the sensitivity analysis for those parameters has been executed in order to find out the design criteria of multiple dynamic absorber using the finite element model of shadow mask. The multiple dynamic absorber(MDA) designed by the proposed method is tested theoretically and experimentally to estimate the efficiency of vibration reduction. From the results, it is verified that the method is feasible to apply the system having the multiple nitration modes and more efficient than the thin wire-type damper used commercially to reduce the vibration of shadow mask.

Positioning and vibration suppression for multiple degrees of freedom flexible structure by genetic algorithm and input shaping

  • Lin, J.;Chiang, C.B.
    • Smart Structures and Systems
    • /
    • 제14권3호
    • /
    • pp.347-365
    • /
    • 2014
  • The main objective of this paper is to develop an innovative methodology for the vibration suppression control of the multiple degrees-of-freedom (MDOF) flexible structure. The proposed structure represented in this research as a clamped-free-free-free truss type plate is rotated by motors. The controller has two loops for tracking and vibration suppression. In addition to stabilizing the actual system, the proposed feedback control is based on a genetic algorithm (GA) to seek the primary optimal control gain for tracking and stabilization purposes. Moreover, input shaping is introduced for the control scheme that limits motion-induced elastic vibration by shaping the reference command. Experimental results are presented, demonstrating that, in the control loop, roll and yaw angles track control and elastic mode stabilization. It was also demonstrated that combining the input shaper with the proportional-integral-derivative (PID) feedback method has been shown to yield improved performance in controlling the flexible structure system. The broad range of problems discussed in this research is valuable in civil, mechanical, and aerospace engineering for flexible structures with MDOM motion.

압전 분기회로를 이용한 다중모드제어 (Multiple-Mode Vibration Control Using Piezoelectric Shunted Actuator)

  • 박철휴
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.202-207
    • /
    • 2002
  • This paper deals with a novel shunted actuator, which has a capability to suppress multi-mode vibration amplitudes by using a pair of piezoceramic patches. In order to describe the characteristic behaviors of shunted dampers connected with a series and a parallel resistor-negative capacitive branch circuit, the stiffness ratio and loss factor with respect to the non-dimensional frequency are considered. To obtain a guideline model of a piezo/beam system connected with a series and a parallel resistor-negative capacitor branch circuit, the governing equations of motion is derived through Hamiltons principle and a piezo sensor equation as well as a shunt damping matrix is developed. The theoretical analysis shows that the shunted actuator developed in this study can significantly reduce multiple-mode vibration amplitudes simultaneously over the whole structural frequency range.

  • PDF

Stochastic stability control analysis of an inclined stay cable under random and periodic support motion excitations

  • Ying, Z.G.;Ni, Y.Q.;Duan, Y.F.
    • Smart Structures and Systems
    • /
    • 제23권6호
    • /
    • pp.641-651
    • /
    • 2019
  • The stochastic stability control of the parameter-excited vibration of an inclined stay cable with multiple modes coupling under random and periodic combined support disturbances is studied by using the direct eigenvalue analysis approach based on the response moment stability, Floquet theorem, Fourier series and matrix eigenvalue analysis. The differential equation with time-varying parameters for the transverse vibration of the inclined cable with control under random and deterministic support disturbances is derived and converted into the randomly and deterministically parameter-excited multi-degree-of-freedom vibration equations. As the stochastic stability of the parameter-excited vibration is mainly determined by the characteristics of perturbation moment, the differential equation with only deterministic parameters for the perturbation second moment is derived based on the $It{\hat{o}}$ stochastic differential rule. The stochastically and deterministically parameter-excited vibration stability is then determined by the deterministic parameter-varying response moment stability. Based on the Floquet theorem, expanding the periodic parameters of the perturbation moment equation and the periodic component of the characteristic perturbation moment expression into the Fourier series yields the eigenvalue equation which determines the perturbation moment behavior. Thus the stochastic stability of the parameter-excited cable vibration under the random and periodic combined support disturbances is determined directly by the matrix eigenvalues. The direct eigenvalue analysis approach is applicable to the stochastic stability of the control cable with multiple modes coupling under various periodic and/or random support disturbances. Numerical results illustrate that the multiple cable modes need to be considered for the stochastic stability of the parameter-excited cable vibration under the random and periodic support disturbances, and the increase of the control damping rather than control stiffness can greatly enhance the stochastic stability of the parameter-excited cable vibration including the frequency width increase of the periodic disturbance and the critical value increase of the random disturbance amplitude.

다중 스마트 TMD를 이용한 대공간 아치구조물의 지진응답 제어 (Seismic Response Control of Spacial Arch Structures using Multiple Smart TMD)

  • 김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제16권1호
    • /
    • pp.43-51
    • /
    • 2016
  • A novel vibration control method for vibration reduction of a spacial structure subjected to earthquake excitation was proposed in this study. Generally, spatial structures have various vibration modes involving high-order modes and their natural frequencies are closely spaced. Therefore, in order to control these modes, a spatially distributed MTMDs (Multiple TMDs) method is proposed previously. MR (Magnetorheological) damper were used to enhance the control performance of the MTMDs. Accordingly, MSTMDs (Multiple Smart TMDs) were proposed in this study. An arch structure was used as an example structure because it has primary characteristics of spatial structures and it is a comparatively simple structure. MSTMDs were applied to the example arch structure and the seismic control performance were evaluated based on the numerical simulation. Fuzzy logic control algorithm (FLC) was used to generate command voltages sent for MSTMSs and the FLC was optimized by genetic algorithm. Based on the analytical results, it has been shown that the MSTMDs effectively decreased the dynamic responses of the arch structure subjected to earthquake loads.