• 제목/요약/키워드: Multiple Buildings

검색결과 275건 처리시간 0.022초

Estimation of peak wind response of building using regression analysis

  • Payan-Serrano, Omar;Bojorquez, Eden;Reyes-Salazar, Alfredo;Ruiz-Garcia, Jorge
    • Wind and Structures
    • /
    • 제29권2호
    • /
    • pp.129-137
    • /
    • 2019
  • The maximum along-wind displacement of a considerable amount of building under simulated wind loads is computed with the aim to produce a simple prediction model using multiple regression analysis with variables transformation. The Shinozuka and Newmark methods are used to simulate the turbulent wind and to calculate the dynamic response, respectively. In order to evaluate the prediction performance of the regression model with longer degree of determination, two complex structural models were analyzed dynamically. In addition, the prediction model proposed is used to estimate and compare the maximum response of two test buildings studied with wind loads by other authors. Finally, it was proved that the prediction model is reliable to estimate the maximum displacements of structures subjected to the wind loads.

Analysis of Multiple Network Accessibilities and Commercial Space Use in Metro Station Areas: An Empirical Case Study of Shanghai, China

  • Zhang, Lingzhu;Zhuang, Yu
    • 국제초고층학회논문집
    • /
    • 제8권1호
    • /
    • pp.49-56
    • /
    • 2019
  • Against the background of the rapid development of the Shanghai Metro network, this paper attempts to establish an analytical approach to evaluate the impact of multiple transport network accessibilities on commercial space use in metro station areas. Ten well-developed metro station areas in central Shanghai are selected as samples. Commercial space floor area and visitors in these areas are collected. Using ArcGIS and Spatial Design Network Analysis, the Shanghai Metro network and road network are modeled to compute diversified transport accessibilities. Evidence from land use and commercial space floor area within a 0-to-500-meter buffer zone of stations is consistent with location and land-use theory: commercial land use is concentrated closer to stations. Correlation analysis suggests that hourly visitors to the shopping mall are mainly influenced by metro network accessibility, while retail stores and restaurants are affected by both metro and pedestrian accessibility.

복합 유해 가스 센서 기반의 조기 경보 시스템을 위한 재난 전조 감시 기준에 관한 연구 (A Study on the Monitoring Criteria of Disaster Signs for Early-warning System based on Multiple Hazardous Gas Sensor)

  • 한규상;박소순;윤인섭
    • 한국가스학회지
    • /
    • 제17권2호
    • /
    • pp.28-35
    • /
    • 2013
  • 대도시 내에 밀집하여 증가하고 있는 대형 복합 건축물은 그 규모와 복잡성으로 인해 유해가스 관련 사고발생시 대형 재난으로의 확대 가능성이 상존한다. 이에 대한 대응책으로, 다종의 유해가스를 감지하는 복합 가스 센서와 이로부터 수집한 정보를 활용한 조기 경보 시스템이 연구되고 있다. 이와 같은 센서 기반 재난 전조 감시 시스템의 효과적인 적용과 운영을 위해서는 적합한 기준이 먼저 마련되어야 한다. 본 연구에서는 유해가스의 감지와 조기 경보 발령을 위한 경보 기준 농도를 제시하고, 각 경보 단계별로 대응 활동과 정보 전파 등 재난 대응 체계를 제안하였다. 재난 감시 기준을 통해 유해가스 관련사고 발생 시 조기에 위험을 감지하여 사고의 경과에 따라 효과적인 대응을 이끌어 낼 수 있다.

다중이용업소 실내마감재료 사용기준에 관한 연구 (A Study on Using the Interior Finishing Material using Regulation at Multiple-using Businesses)

  • 김용성;조성오
    • 한국실내디자인학회논문집
    • /
    • 제22권5호
    • /
    • pp.216-224
    • /
    • 2013
  • There are the relevant provisions that apply to building regulations about the Building codes, Fire Protection laws, and more Multi-using interior finish materials businesses etc. The differences between these regulations are as follows: The Building codes is defined the main use of the building according to facilities to used to set the scale by the use of the floor space, On the other hand, Fire Protection laws are the basic purpose and the act of using the architectural space(or sales) by separating object by fire. And Multiple-using Businesses Facilities consist of two regulations engaged in the kind of law and the size of the floor area. One building can not be based on operating facilities and together in Multiple use businesses Law. As such, the Buildings are applied to the Building codes, Fire Protection laws, such as Multi-using Businesses Facilities interior construction industry due to the structural differences in the position of the designer feeling a lot of difficulties and confusion. The Multi-use businesses Facilities engage in the kind of law, the size of the floor area and seating capacity. These can not be based on operating facilities, and consists of two regulations together in one building. This study is purposed to help improving the finish of the interior architecture that is related to the Building code regulations, Fire Protection laws, Multi-using Facilities interior finishing material relevant with the provisions from the law through analyze the case of developed countries, and the current Multiple use Businesses Facilities research range from the law of multiple-using facilities, interior finishing, interior architecture for supervision reasonably and compensation for the interior design. So, Result is as follows: First, interior decorations can be separated the fixed material and the moveable things. second, It should be included multi-using Business though small size business space at the basement floor. third, It should be established statute law that design and construction responsibility. forth, re-testing fire resist performance after some period. and finally, it need to mitigate regulation where be installed sprinkler.

Predicting of tall building response to non-stationary winds using multiple wind speed samples

  • Huang, Guoqing;Chen, Xinzhong;Liao, Haili;Li, Mingshui
    • Wind and Structures
    • /
    • 제17권2호
    • /
    • pp.227-244
    • /
    • 2013
  • Non-stationary extreme winds such as thunderstorm downbursts are responsible for many structural damages. This research presents a time domain approach for estimating along-wind load effects on tall buildings using multiple wind speed time history samples, which are simulated from evolutionary power spectra density (EPSD) functions of non-stationary wind fluctuations using the method developed by the authors' earlier research. The influence of transient wind loads on various responses including time-varying mean, root-mean-square value and peak factor is also studied. Furthermore, a simplified model is proposed to describe the non-stationary wind fluctuation as a uniformly modulated process with a modulation function following the time-varying mean. Finally, the probabilistic extreme response and peak factor are quantified based on the up-crossing theory of non-stationary process. As compared to the time domain response analysis using limited samples of wind record, usually one sample, the analysis using multiple samples presented in this study will provide more statistical information of responses. The time domain simulation also facilitates consideration of nonlinearities of structural and wind load characteristics over previous frequency domain analysis.

다중 슬림형 감쇠장치의 개발 및 성능 실험 (Development of Multiple Slim Type Damper System and Performance Test)

  • 성은희;김다위;박두환;박관순;박장호;조해진
    • 한국안전학회지
    • /
    • 제29권2호
    • /
    • pp.31-37
    • /
    • 2014
  • For the vibration control of residential buildings, a multiple type slim damper system is developed and dynamic performance test is performed in this study. In conventional damping systems, larger installation space is required in order to achieve acceptable seismic performance, and as a result, it is difficult to determine efficient damping capacity of the device. The proposed damping device is composed of several small slim type dampers and linkage units. It can control damping capacity easily by changing the number of the small damper. To evaluate the proposed damping device, three slim type dampers (single-type, triple-type and penta-type) are designed and manufactured in real scale. Dynamic loading tests are performed by using the three manufactured dampers. From the tests, it is shown that damping coefficient is proportional to the number of the damper combined. Thus, test results validates the practicality of the proposed slim type dampers. applying nonlinear curve fitting technique, numerical model of the dampers are developed and presented.

원주의 등분할에 의한 전통구조물의 평면구성기법분석에 관한 연구 (An Analysis on Techniques of Moulding of Korean Traditional Structure and Architectures through Equal Subdividing Circumference Methods)

  • 이주원;정기호
    • 한국조경학회지
    • /
    • 제28권3호
    • /
    • pp.97-104
    • /
    • 2000
  • Studies on the principle of traditional moulding techniques of architecture or structure are very important in the point of the work could accomplish succession to modern design. As an attempt of these work, this study tried to examine traditional moulding techniques applied in planes of ancient architecture and structure closely. The major findings of this study are summarized as follows; It was verified that planes of ancient Korean architectures and structures analyzed in this study was moulded by its multiple partitions with the six or eight partitions of circumference as the fundamental form. The well unearthed in kyong-bok palace recently was moulded by a concentric circle assumed form of 4 circle which was extended with equal interval and divided into multiple of 8 partition of circumference. Chon-duk-jung in chang-duk palace also was moulded by a concentric circle assumed form of 3 circle extended with equal interval, but circle were divide by 6 partitions. It was also found that 6$^{\circ}$§8 partitions of circumference(or its multiple partition) was applied to not only above structures but also the moulding planes of ancient architecture, and as a results, figures revealed in architectures analyzed is classified into three classes. And, this study analyzed arrangements of two temples. As a results, it is discovered that the Grid used in moulding planes of each building fixed the arrangement of buildings. Therefore, moulding by equal partition of circumference decided the form of each building and the relation of element at the same time.

  • PDF

파력발전용 가변수주진동장치의 운동에 대한 실험적 연구 (2. 다수 부유체) (Experimental study on motions of VLCO for wave power generation (2. Multiple floating bodies))

  • 이승철;구자삼
    • 한국해양공학회지
    • /
    • 제27권6호
    • /
    • pp.27-31
    • /
    • 2013
  • The structure of a variable liquid column oscillator(VLCO) is analogous to that of the tuned liquid column damper used to suppress oscillatory motion in large structures like tall buildings and cargo ships. The VLCO is a system for absorbing the high kinetic energy of the accelerated motions of multiple floating bodies using an air-spring effect produced the installation of inner air chambers. Thus, a VLCO can improve the energy efficiency of the activating object type of wave energy converters made by the Pelamis Company. In this research, an experiment was performed in two cases: with the top valves closed and open. The floating bodies were connected by hinges. The effect of the internal flow was estimated by comparing the results for the closed and open valves.

Energy Saving Potential and Indoor Air Quality Benefits of Multiple Zone Dedicated Outdoor Air System

  • Lee, Soo-Jin;Jeong, Jae-Weon
    • 국제초고층학회논문집
    • /
    • 제8권1호
    • /
    • pp.71-82
    • /
    • 2019
  • The purpose of this study is to evaluate the indoor air quality (IAQ) and energy benefits of a dedicated outdoor air system (DOAS) and compare them with a conventional variable air volume (VAV) system. The DOAS is a decoupled system that supplies only outdoor air, while reducing its consumption using an enthalpy wheel. The VAV system supplies air that is mixed outdoor and transferred indoor. The VAV has the issue of unbalanced ventilation in each room in multiple zones because it supplies mixing air. The DOAS does not have this problem because it supplies only outdoor air. That is, the DOAS is a 100% outdoor air system and the VAV is an air conditioning system. The transient simulations of carbon dioxide concentration and energy consumption were performed using a MATLAB program based on the thermal loads from the model predicted by the TRNSYS 18 program. The results indicated that when the air volume is large, such as in summer, the distribution of air is not appropriate in the VAV system. The DOAS however, supplies the outdoor air stably. Moreover, in terms of annual primary energy consumption, the DOAS consumed approximately 40% less energy than the VAV system.

Multiple linear regression and fuzzy linear regression based assessment of postseismic structural damage indices

  • Fani I. Gkountakou;Anaxagoras Elenas;Basil K. Papadopoulos
    • Earthquakes and Structures
    • /
    • 제24권6호
    • /
    • pp.429-437
    • /
    • 2023
  • This paper studied the prediction of structural damage indices to buildings after earthquake occurrence using Multiple Linear Regression (MLR) and Fuzzy Linear Regression (FLR) methods. Particularly, the structural damage degree, represented by the Maximum Inter Story Drift Ratio (MISDR), is an essential factor that ensures the safety of the building. Thus, the seismic response of a steel building was evaluated, utilizing 65 seismic accelerograms as input signals. Among the several response quantities, the focus is on the MISDR, which expresses the postseismic damage status. Using MLR and FLR methods and comparing the outputs with the corresponding evaluated by nonlinear dynamic analyses, it was concluded that the FLR method had the most accurate prediction results in contrast to the MLR method. A blind prediction applying a set of another 10 artificial accelerograms also examined the model's effectiveness. The results revealed that the use of the FLR method had the smallest average percentage error level for every set of applied accelerograms, and thus it is a suitable modeling tool in earthquake engineering.