• Title/Summary/Keyword: Multidetector Computed Tomography

Search Result 126, Processing Time 0.03 seconds

Clinical Application of Cardiac Hybrid Imaging in Coronary Artery Disease (관상동맥질환에서 심장 하이브리드 영상의 임상적 이용)

  • Gho, Ihn-Ho;Kong, Eun-Jung
    • Journal of Yeungnam Medical Science
    • /
    • v.26 no.1
    • /
    • pp.15-23
    • /
    • 2009
  • Constant technological developments in coronary artery disease have contributed to the assessment of both the presence of coronary stenosis and its hemodynamic consequences. Hence, noninvasive imaging helps guide therapeutic decisions by providing complementary information on coronary morphology and on myocardial perfusion and metabolism. This can he done using single photon emission computed tomography (SPECT) or positron emission tomography (PET) and multidetector CT (MDCT). Advances in image-processing software and the advent of SPECT/CT and PET/CT have paved the way for the combination of image datasets from different modalities, giving rise to hybrid imaging. Three dimensional cardiac hybrid imaging helped to confirm hemodynamic significance in many lesions, add new lesions such as left main coronay artery disease, exclude equivocal defects, correct the corresponding arteries to their allocated defects and identify culprit segment. Cardiac hybrid imaging avoids the mental integration of functional and morphologic images and facilitates a comprehensive interpretation of coronaty lesions and their pathophysiologic adequacy by three dimensional display of fused images, and allows the best evaluation of myocardial territories and the coronary-artery branches that serve each territory. This integration of functional and morphological information were feasible to intuitively convincing and might facilitate development of a comprehensive non-invasive assessment of coronary artery disease.

  • PDF

An unusual presentation of osteoblastoma of the maxilla: A case report

  • Lim, Joonbum;Hinchy, Nicole;Odingo, Nora;Colosi, Dan;Mahdian, Mina
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.455-460
    • /
    • 2021
  • This report presents a rare case of maxillary osteoblastoma in a 17-year-old female. The patient presented with dull pain and facial asymmetry inferior to the left zygoma. An intraoral examination found a painless swelling on the buccal gingival tissue in the left posterior maxilla. Panoramic radiographs and multidetector computed tomographic images revealed an ill-defined, non-corticated, mixed attenuating entity of osseous density located within the left posterior maxilla apical to the left maxillary molars. The entity exhibited a heterogeneous internal structure with a fine granular appearance, and the periphery showed a partial hypo-attenuating rim along the antero-medial aspect. Expansion of the left posterior maxilla accompanied with displacement of the left maxillary sinus floor was noted. External root resorption of the first and second molars was noted, as well as postero-superior displacement of the third molar. The histopathologic diagnosis of the biopsy was osteoblastoma. Complete excision of the tumor was performed.

Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

  • Jeong, Dae-Kyo;Lee, Sang-Chul;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.42 no.2
    • /
    • pp.65-70
    • /
    • 2012
  • Purpose : The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Materials and Methods : Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. Results : The effective dose was the highest for Somatom Sensation 10 (425.84 ${\mu}Sv$), followed by AZ3000CT (332.4 ${\mu}Sv$), Somatom Emotion 6 (199.38 ${\mu}Sv$), and 3D eXaM (111.6 ${\mu}Sv$); it was the lowest for Implagraphy (83.09 ${\mu}Sv$). The CBCT showed significant variation in dose level with different device. Conclusion : The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

Computed tomographic diagnosis of broncholithiasis in a cat

  • Kim, Rakhoon;An, Soyon;Hwang, Gunha;Ryu, Jeongmin;Kim, Minji;Yoon, Jiwon;Noh, Seul Ah;Yu, DoHyeon;Lee, Hee Chun;Hwang, Tae Sung
    • Korean Journal of Veterinary Research
    • /
    • v.62 no.3
    • /
    • pp.23.1-23.5
    • /
    • 2022
  • A 5-year-old castrated male domestic shorthair cat was referred for further investigation of pulmonary nodules incidentally detected on thoracic radiographs. Thoracic radiographs identified ill-defined soft tissue opacity nodules with small faint mineral opacity. Thoracic computed tomography (CT) revealed that bronchial dilation and bronchial wall thickening in bilateral cranial and accessory lung lobes. Round to ellipsoid mineralized concretions were found embedded in the intrabronchial soft tissue attenuation material. Based on radiography, CT, and cytology, the patient was tentatively diagnosed as having broncholithiasis with chronic bronchitis. This report described the CT diagnosis of broncholithiasis, which has been rarely reported in a cat.

Correlation between mandibular morphology and masticatory muscle thickness in normal occlusion and mandibular prognathism

  • Kim, Tae-Ho;Kim, Chul-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.5
    • /
    • pp.313-320
    • /
    • 2020
  • Objectives: The aim of this study was to evaluate the relationship between masticatory muscle thickness and mandibular morphology in young Korean adults with normal occlusion and mandibular prognathism. Patients and Methods: Multidetector computed tomography (MDCT) was used to measure the masticatory muscle thickness on the right side in 100 Korean young adults (50 normal occlusion group, 50 mandibular prognathism group). Cephalometric analysis was done to measure mandibular morphology. Pearson correlation analysis was done to investigate the relationship between the masticatory muscle thickness and mandibular morphometry. Results: The four masticatory muscles showed positive correlation with intergonial width in all subjects. All muscles, except temporalis, positively correlated with height of the ramus and mandibular length. Positive correlation was also observed in all muscles, except medial pterygoid, with thickness of the ramus. In the normal occlusion group, all four masticatory muscles showed positive correlation with intergonial width and ramus thickness. Positive correlation was also observed in all muscles (except lateral pterygoid) with mandibular length. Masseter and lateral pterygoid positively correlated with height of the ramus. In the mandibular prognathism group, all masticatory muscles, except lateral pterygoid, showed positive correlation with intergonial width. The masseter muscle showed negative correlation with ANB. Conclusion: The results suggest a positive correlation of the thickness of masticatory muscles with both horizontal and vertical dimensions of the mandible. However, thickness of the masseter was found to decrease in patients with increasing severity of mandibular prognathism.

Robust Pelvic Coordinate System Determination for Pose Changes in Multidetector-row Computed Tomography Images

  • Kobashi, Syoji;Fujimoto, Satoshi;Nishiyama, Takayuki;Kanzaki, Noriyuki;Fujishiro, Takaaki;Shibanuma, Nao;Kuramoto, Kei;Kurosaka, Masahiro;Hata, Yutaka
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2010
  • For developing navigation system of total hip arthroplasty (THA) and evaluating hip joint kinematics, 3-D pose position of the femur and acetabulum in the pelvic coordinate system has been quantified. The pelvic coordinate system is determined by manually indicating pelvic landmarks in multidetector-row computed tomography (MDCT) images. It includes intra- and inter-observer variability, and may result in a variability of THA operation or diagnosis. To reduce the variability of pelvic coordinate system determination, this paper proposes an automated method in MDCT images. The proposed method determines pelvic coordinate system automatically by detecting pelvic landmarks on anterior pelvic plane (APP) from MDCT images. The method calibrates pelvic pose by using silhouette images to suppress the affect of pelvic pose change. As a result of comparing with manual determination, the proposed method determined the coordinate system with a mean displacement of $2.6\;{\pm}\;1.6$ mm and a mean angle error of $0.78\;{\pm}\;0.34$ deg on 5 THA subjects. For changes of pelvic pose position within 10 deg, standard deviation of displacement was 3.7 mm, and of pose was 1.28 deg. We confirmed the proposed method was robust for pelvic pose changes.

Reviews of Radiation Protection and Shielding for Computed Tomography in Foreign Countries (외국의 컴퓨터 단층촬영 장치의 방어시설 문헌 조사)

  • Jahng, Geon-Ho;Yang, Dal-Mo;Sung, Dong-Wook;Lee, Kwang-Yong;Kim, Hyeog-Ju
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.276-284
    • /
    • 2008
  • A computed tomography (CT) is a powerful system for the effectively fast and accurate diagnosis. The CT system, therefore, has used substantially and developed for improving the performance over the past decade, resulting in growing concerns over the radiation dose from the CT. Advanced CT techniques, such as a multidetector row CT scanner and dual energy or dual source CT, have led to new clinical applications that could result in further increases of radiation does for both patients and workers. The objective of this study was to review the international guidelines of the shielding requirements for a CT facility required for a new installation or when modifying an existing one. We used Google Search Engine to search the following keywords: computed tomography, CT regulation or shield or protection, dual energy or dual source CT, multidetector CT, CT radiation protection, and regulatory or legislation or regulation CT. In addition, we searched some special websites, that were provided for sources of radiation protection, shielding, and regulation, RSNA, AAPM, FDA, NIH, RCR, ICRP, IRPA, ICRP, IAEA, WHO (See in Table 1 for full explanations of the abbreviations). We finally summarized results of the investigated materials for each country. The shielding requirement of the CT room design was very well documented in the countries of Canada, United States of America, and United Kingdom. The wall thickness of the CT room could be obtained by the iso-exposure contour or the point source method. Most of documents provided by international organizations were explained in importance of radiation reduction in patients and workers. However, there were no directly-related documents of shielding and patient exposure dose for the dual energy CT system. Based international guidelines, the guideline of the CT room shielding and radiation reduction in patients and workers should be specified for all kinds of CT systems, included in the dual energy CT. We proposed some possible strategies in this paper.

  • PDF

Directions of mandibular canal displacement in ameloblastoma: A computed tomography mirrored-method analysis

  • Evangelista, Karine;Cardoso, Lincoln;Toledo, Italo;Gasperini, Giovanni;Valladares-Neto, Jose;Cevidanes, Lucia Helena Soares;de Oliveira Ruellas, Antonio Carlos;Silva, Maria Alves Garcia
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.17-25
    • /
    • 2021
  • Purpose: This study was performed to investigate mandibular canal displacement in patients with ameloblastoma using a 3-dimensional mirrored-model analysis. Materials and Methods: The sample consisted of computed tomographic scans of patients with ameloblastoma (n=10) and healthy controls (n=20). The amount of mandibular canal asymmetry was recorded as a continuous variable, while the buccolingual (yaw) and supero-inferior (pitch) directions of displacement were classified as categorical variables. The t-test for independent samples and the Fisher exact test were used to compare groups in terms of differences between sides and the presence of asymmetric inclinations, respectively (P<0.05). Results: The length of the mandibular canal was similar on both sides in both groups. The ameloblastoma group presented more lateral (2.40±4.16 mm) and inferior (-1.97±1.92 mm) positions of the mental foramen, and a more buccal (1.09±2.75 mm) position of the middle canal point on the lesion side. Displacement of the mandibular canal tended to be found in the anterior region in patients with ameloblastoma, occurring toward the buccal and inferior directions in 60% and 70% of ameloblastoma patients, respectively. Conclusion: Mandibular canal displacement due to ameloblastoma could be detected by this superimposed mirrored method, and displacement was more prevalent toward the inferior and buccal directions. This displacement affected the mental foramen position, but did not lead to a change in the length of the mandibular canal. The control group presented no mandibular canal displacement.

Quantitative Analysis of Factors Affecting Cobalt Alloy Clip Artifacts in Computed Tomography

  • Sim, Sook Young;Choi, Chi Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.5
    • /
    • pp.400-404
    • /
    • 2014
  • Objective : Clip artifacts limit the visualization of intracranial structures in CT scans from patients after aneurysmal clipping with cobalt alloy clips. This study is to analyze the parameters influencing the degree of clip artifacts. Methods : Postoperative CT scans of 60 patients with straight cobalt alloy-clipped aneurysms were analyzed for the maximal diameter of white artifacts and the angle and number of streak artifacts in axial images, and the maximal diameter of artifacts in three-dimensional (3-D) volume-rendered images. The correlation coefficient (CC) was determined between each clip artifact type and the clip blade length and clip orientation to the CT scan (angle a, lateral clip inclination in axial images; angle b, clip gradient to scan plane in lateral scout images). Results : Angle b correlated negatively with white artifacts (r=-0.589, p<0.001) and positively with the angle (r=0.636, p<0.001) and number (r=0.505, p<0.001) of streak artifacts. Artifacts in 3-D images correlated with clip blade length (r=0.454, p=0.004). Multiple linear regression analysis revealed that angle b was the major parameter influencing white artifacts and the angle and number of streak artifacts in axial images (p<0.001), whereas clip blade length was a major factor in 3-D images (p=0.034). Conclusion : Use of a clip orientation perpendicular to the scan gantry angle decreased the amount of white artifacts and allowed better visualization of the clip site.