• Title/Summary/Keyword: Multichannel Feedback

Search Result 12, Processing Time 0.016 seconds

Low-Power Implementation of A Multichannel Hearing Aid Using A General-purpose DSP Chip (범용 DSP 칩을 이용한 다중 채널 보청기의 저전력 구현)

  • Kim, Bum-Jun;Byun, Joon;Park, Young-Cheol
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.1
    • /
    • pp.18-25
    • /
    • 2018
  • In this paper, we present a low-power implementation of the multi-channel hearing aid system using a general-purpose DSP chip. The system includes an acoustic amplification algorithm based on Wide Dynamic Range Compression (WDRC), an adaptive howling canceller, and a single-channel noise reduction algorithm. To achieve a low-power implementation, each algorithm is re-constructed in forms of integer program, and the integer program is converted to the assembly program using BelaSigna(R) 250 instructions. Through experiments using the implementation system, the performance of each processing algorithm was confirmed in real-time. Also, the clock of the implementation system was measured, and it was confirmed that the entire signal processing blocks can be performed in real time at about 7.02MHz system clock.

The characteristics of DROS magnetometer and MCG measurement (DROS 자력계의 동작특성 및 심자도 측정)

  • Kang, C.S.;Lee, Y.H.;Kwon, H.;Kim, J.M.;Yu, K.K.;Park, Y.K.;Lee, S.G.
    • Progress in Superconductivity
    • /
    • v.8 no.2
    • /
    • pp.164-168
    • /
    • 2007
  • We developed a SQUID magnetometer based on Double Relaxation Oscillation SQUID(DROS) for measuring magnetocardiography(MCG). Since DROS provides a 10 times larger flux-to-voltage transfer coefficient than the conventional DC-SQUID, simple flux-locked loop electronics could be used for SQUID operation. Especially, we adopted an external feedback to eliminate the magnetic coupling with adjacent channels. When the DROS magnetometer was operated inside a magnetically shielded room, average magnetic field noise was about 5 $fT/^{\surd}Hz$ at 100 Hz. Using the DROS magnetometer, we constructed a multichannel MCG system. The system consisted of 61 magnetometers are arranged in a hexagonal structure and measures a vertical magnetic-field component to the chest surface. The distance between adjacent channels is 26 mm and the magnetometers cover a circular area with a diameter of 208 mm. We recorded the MCG signals with this system and confirmed the magnetic field distribution and the myocardinal current distribution.

  • PDF