• 제목/요약/키워드: Multi-unit level 3 PSA

검색결과 12건 처리시간 0.015초

A new method to calculate a standard set of finite cloud dose correction factors for the level 3 probabilistic safety assessment of nuclear power plants

  • Gee Man Lee;Woo Sik Jung
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1225-1233
    • /
    • 2024
  • Level 3 probabilistic safety assessment (PSA) is performed to calculate radionuclide concentrations and exposure dose resulting from nuclear power plant accidents. To calculate the external exposure dose from the released radioactive materials, the radionuclide concentrations are multiplied by two factors of dose coefficient and a finite cloud dose correction factor (FCDCF), and the obtained values are summed. This indicates that a standard set of FCDCFs is required for external exposure dose calculations. To calculate a standard set of FCDCFs, the effective distance from the release point to the receptor along the wind direction should be predetermined. The TID-24190 document published in 1968 provides equations to calculate FCDCFs and the resultant standard set of FCDCFs. However, it does not provide any explanation on the effective distance required to calculate the standard set of FCDCFs. In 2021, Sandia National Laboratories (SNLs) proposed a method to predetermine finite effective distances depending on the atmospheric stability classes A to F, which results in six standard sets of FCDCFs. Meanwhile, independently of the SNLs, the authors of this paper discovered that an infinite effective distance assumption is a very reasonable approach to calculate one standard set of FCDCFs, and they implemented it into the multi-unit radiological consequence calculator (MURCC) code, which is a post-processor of the level 3 PSA codes. This paper calculates and compares short- and long-range FCDCFs calculated using the TID-24190, SNLs method, and MURCC method, and explains the strength of the MURCC method over the SNLs method. Although six standard sets of FCDCFs are required by the SNLs method, one standard sets of FCDCFs are sufficient by the MURCC method. Additionally, the use of the MURCC method and its resultant FCDCFs for level 3 PSA was strongly recommended.

원전 중대사고 연계 소외결말해석 전산체계에 대한 고찰 (Study on the Code System for the Off-Site Consequences Assessment of Severe Nuclear Accident)

  • 김소라;민병일;박기현;양병모;서경석
    • 방사성폐기물학회지
    • /
    • 제14권4호
    • /
    • pp.423-434
    • /
    • 2016
  • 인접 국가인 일본의 후쿠시마 원전에서 극한 자연재해로 인한 중대사고가 발생하면서, 국내에서 중대사고 및 확률론적 안전성 평가 (PSA, Probabilistic Safety Assessment)에 대한 중요성이 재인식되었다. 국내에서는 원전의 소외결말을 평가하는 3단계 PSA에 대한 연구개발이 최근까지 거의 이루어지지 않았다. 본 논문에서는 국외 3단계 PSA 전산코드 중, 미국의 MACCS2 (MELCORE Accident Consequence Code System 2), 유럽의 COSYMA (COde SYstem from Maria) 그리고 일본의 OSCAAR (Off-Site Consequence Analysis code for Atmospheric Releases in reactor accidents)에 대한 간략한 분석과 미국의 MACCS2에 대한 단점 및 한계점 분석을 수행하였다. 국내 외 전문가들에 의해 공통적으로 지적되어 온 MACCS2의 한계점은 다수호기사고와 사용후핵연료 저장조로부터의 방출 모사의 불가능, 그리고 대기확산모델을 단순 가우시안 플륨모델을 기본으로 한다는 것이며, 이중 일부는 MACCS2업데이트 버전을 통해 개선되어 왔다. Food chain 모델의 모사의 제한, 해양 및 수계 확산모델의 부재, 제한된 범위의 경제영향평가 등 또한 개선되어야 할 사항이다. 기술보고의 결과는 국내 3단계 PSA 관련 기술 개발을 위한 기초자료로 활용될 수 있을 것으로 기대된다.