• Title/Summary/Keyword: Multi-probe method

Search Result 67, Processing Time 0.026 seconds

Planar Microstrip Patch Antenna for 5G Wireless Applications

  • Kim, Jang-Wook;Jeon, Joo-Seong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.1
    • /
    • pp.33-41
    • /
    • 2022
  • This paper describes a planar microstrip patch antenna designed on dielectric substrate. Two types of planar microstrip patch antennas are studied for the 5G wireless applications, one type is conventional microstrip structure, the other type is stacked microstrip structure fed by coaxial probe. Using electromagnetically coupling method, stacked microstrip patch antenna employing a multi-layer substrate structure was designed. The results indicate that the proposed stacked microstrip patch antenna performs well at 5G wireless service bandwith a broadband from 3.42GHz to 3.70GHz. The impedance bandwidth(VSWR≤2) is 360MHz(10.28%) from 3.42GHz to 3.78GHz. In this paper, through the designing of a stacked microstrip patch antenna, we have presented the availability for 5G wireless repeater system.

Arthroscopic Evaluation for Endoscopic ACL Reconstruction Using a Multi-stranded Hamstring Tendon Graft and EndoButton (슬괵 건을 이용한 전방십자인대 재건술후 2차 관절경적 평가)

  • Lee, Kwang-Won;Lee, Byeong-Ki;Ryu, Chang-Soo;Keum, Teok-Seop;Choy, Won-Sik;Kim, Joon-Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.2
    • /
    • pp.124-128
    • /
    • 1998
  • From Feb. 1996 to Feb. 1997. among sixty-four patients of anterior cruciate ligament(ACL) reconstruction using multi-stranded hamstring tendon and EndoButton fixation, twenty-five patients of volunteer, 15 men and 10 women, from 16 to 50 years of age(mean 27.6 years) underwent arthroscopic evaluation. Arthroscopic evaluation was routinely performed one year after surgery along with an examination of stability. The purpose of this study was to arthroscopically evaluate the morphological changes that occurred in hamstring tendon autograft one year after ACL reconstruction. Both of the tendon graft and the adjacent fibrous tissues were observed for gross appearance and physical properties with probing and response to passive anterior translation. Biopsy samples were taken from the surrounding fibrous tissue and the tendon graft. Grossly, we found a well-defined ligamentous structure with good tension tested with a probe. A common finding was that the reconstructed ligaments were embedded in a layer of the synovium, and blood vessels could be seen on the anterior surface of the ligament. The biopsy tissue was placed in formalin solution and subjected to histological preparation by hematoxylin and eosin staining method. The hamstring tendon graft appeared histologically normal under light microscopic finding. There were a few vessels located between existing collagen bundles, and the vessels had an orderly pattern. The surrounding fibrous tissue envelope was covered with synovium. We pleased with preliminary findings in our evaluation.

  • PDF

Study on Enhancements to Ultrasonic Data Imaging Using Full Matrix Capture Technique (Full Matrix Capture 기법을 통한 초음파신호 영상화 향상 연구)

  • Lee, Tae-Hun;Yoon, Byung-Sik;Lee, Jeong-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.5
    • /
    • pp.299-306
    • /
    • 2015
  • A conventional phased array system can control an ultrasonic beam electronically by adjusting the excitation time delay of individual elements in a multi-element probe and produce an ultrasonic image. In Contrast, full matrix capture (FMC) is a data acquisition process that allows receiving ultrasonic signals from one single shot of the phased array transducer element through all the other elements and captures the complete dataset from every possible transmit-receive combination. This FMC data can be used to create the ultrasonic image in post processing. It is possible to produce not only images equivalent to conventional phased array image but also total focusing method (TFM) images with improved resolution and sharpness, which is virtually focused at any point in a region of interest. In this paper, the system that can perform FMC by using a conventional phased array instrument is developed, and a study was conducted on the imaging algorithms to reconstruct sector B-scan and TFM images from FMC dataset.

Characteristics of Wakes in a Viscous Liquid Medium of a Simulated GTL Process (모사된 GTL공정의 점성액체 매체에서 wake의 특성)

  • Lim, Dae Ho;Jang, Ji Hwa;Kang, Yong;Jun, Ki Won
    • Korean Chemical Engineering Research
    • /
    • v.49 no.5
    • /
    • pp.571-576
    • /
    • 2011
  • Characteristics of bubble driven wakes were investigated in a simulated GTL process(0.102 m ${\times}$ 1.5 m in height) with viscous liquid medium. Effects of gas velocity(0.04 ~ 0.12 m/s) and liquid viscosity(0.001 ~ 0.050 $Pa{\cdot}s$) on the wake characteristics such as rising velocity, frequency, size and holdup were determined by employing a resistivity probe method. The wake phase formed behind the rising multi-bubbles as well as single bubbles were detected effectively from the conductivity fluctuations measured by the probe. Compressed, filtered and regulated air and aqueous solutions of Carboxy Methyl Cellulose(CMC) were used as a dispersed gas phase and a continuous liquid medium, respectively. It was found that the rising velocity and size of wake phase increased with an increase in gas velocity or liquid viscosity. The holdup and frequency of wake phase increased with increasing gas velocity due to the increase of gas input into the process with increasing gas velocity. However, the values of holdup and frequency of wake phase decreased with increasing liquid viscosity, since the size of bubbles and thus that of wakes increased with increasing liquid viscosity. The ratio of wake holdup to that of gas phase, which was in the range of 0.25 ~ 0.48, increased with an increase in liquid viscosity but decreased with gas velocity. The wake characteristics were well correlated in terms of operating variables within this experimental conditions.

Characterization and Electrical Conductivity of Carbon-Coated Metallic (Ni, Cu, Sn) Nanocapsules

  • Wang, Dong Xing;Shah, Asif;Zhou, Lei;Zhang, Xue Feng;Liu, Chun Jing;Huang, Hao;Dong, Xing Long
    • Applied Microscopy
    • /
    • v.45 no.4
    • /
    • pp.236-241
    • /
    • 2015
  • Carbon-coated Ni, Cu and Sn nanocapsules were investigated by means of X-ray diffraction (XRD), transmission electron microscopy (TEM) and a four-point probe device. All of these nanocapsules were prepared by an arc-discharge method, in which the bulk metals were evaporated under methane ($CH_4$) atmosphere. Three pure metals (Ni, Cu, Sn) were typically diverse in formation of the carbon encapsulated nanoparticles and their different mechanisms were investigated. It was indicated that a thick carbon layers formed on the surface of Ni(C) nanocapsules, whereas a thin shell of carbon with 1~2 layers covered on Cu(C) nanocapsules, and the Sn(C) nanocapsules was, in fact, a longger multi-walled carbon nanotubes partially-filled with metal Sn. As one typical magnetic/dielectric nanocomposite particles, Ni(C) nanocapsules and its counterpart of oxide-coated Ni(O) nanocapsules were compared in the electrically conductive behaviors for further applications as the electromagnetic materials.

Ground Subsidence Measurements of Noksan National Industrial Complex using C-band Multi-temporal SAR images (C-밴드 다중시기 SAR 위성 영상을 이용한 녹산국가산업단지 일대의 지반침하 관측)

  • Cho, Minji;Lee, Chang-Wook
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.2
    • /
    • pp.161-172
    • /
    • 2014
  • Established in the lower reaches of the Nakdong river in Busan, the Noksan national industrial complex is one of the deepest soft ground areas in Korea. In case of the costal landfill having deep soft ground, there is a significant residual settlement over a long period of time. In this study, there was observed ground subsidence occurred in the Noksan national industrial complex from September 2002 to April 2007 by applying DInSAR and SBAS time series method using RADARSAT-1 and Envisat SAR datasets. As a result, it was calculated that ground subsidence developed at the velocity of about maximum 10 cm/yr and mean 6 cm/yr at the eastern center, west, western center and southern area contiguous on the coastline of the study area during the period from September 2002 to April 2007. In addition, the RADARSAT-1 average displacement map has been compared with the total displacement map observed by accurate magnetic probe extensometer during the period from 2001 to 2002. Since the time series displacement has shown a linear trend mostly, we consider that continuous monitoring should be needed until the ground subsidence of the study area has been stabilized.

Analysis and the measurement of the variation of electric field in air and oil using optical measuring system (광계측 시스템을 이용한 유.기중 코로나 방전의 전계변화 측정 및 비교분석)

  • Ma, Ji-Hoon;Ryu, Cheol-Hwi;Kang, Won-Jong;Chang, Yong-Moo;Koo, Ja_Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1668-1670
    • /
    • 2002
  • Since more than two decades, the conventional PD detecting systems have been employed in order to detect the partial discharges occurring inside the HV power apparatus for their diagnosis by use of different type of detection such as acoustic and UHF detection method. Regardless of their wide on-site application, a certain number of technical inconveniences have been disclosed as follows : multistage amplification. large volume, susceptible to external noise and high price. In this respect, the optical measurement techniques are widely proposed in these days in this concerned field ascribed to the following advantages : immune to external EMI noise and broad band response of the Pockels cell covering from DC to GHz. However, the reliability of several proposed techniques enabling to measure the electric field inside the large high power apparatus has not yet been well approved In this work, an optical measuring system, based on the Pockels effect, has been developed for measuring the field variation due to the corona discharges occurring in air and in oil. This system consists of He-Ne laser, single mode optical fiber, multi mode optical fiber, polarizing film, Y-cut LiNbO3 cell, photo detector, digital oscilloscope and personal computer with GPIB. For this purpose, optical probe has been specially designed and realized and put into the needle-plane electrode. Afterward, same measurement is carried out in oil. We demonstrate the characteristic of the optical measuring system and the measurement results.

  • PDF

Clinical Usefulness of the Line Probe Assay for Rapid Detection of Rifampicin-resistant Tuberculosis (Line probe assay를 이용한 신속한 rifampicin내성결핵 진단법의 임상적 유용성)

  • Hong, Sang-Bum;Lim, Chae-Man;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Shim, Tae-Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.3
    • /
    • pp.334-342
    • /
    • 2001
  • Background : RpoB gene mutations have been found in about 96-98% of rifampicin (RMP)-resistant Mycobacterium tuberculosis. Recent reports confirm that the in laboratory settings a rpoB gene mutation can be used as a surrogate marker for multi-drug resistant tuberculosis. However, its usefulness in clinical applications has not been evaluated. This study was performed to confirm whether mutation analysis of the rpoB gene of M. tuberculosis is useful in clinical settings. Methods : The medical records of 33 patients in whom rpoB gene analysis was conducted using an INNOLiPA Rif. TB assay (LiPA) from June, 1998, to July, 2000, at the Asan Medical Center were retrospectively reviewed in 33 patients. The clinical characteristics in addition to the drug susceptibility and LiPA results were analyzed. The drug susceptibility test was considered as a gold standard method for M. tuberculosis susceptibility and these results were compared with those of the rpoB gene study and sequencing analysis. Sequencing analysis of the rpoB gene was done in cases where there was a discrepancy between the results of the drug susceptibility an d rpoB gene study. Results : The mean age and sex ratio was $42{\pm}18$, and 24:9 (M:F), respectively. There were 19 RMP susceptible (58%) and 14 RMP-resistant cases (42%) according to the rpoB gene study. The mean time from the request to reporting the results of the rpoB gene study was $5.2{\pm}2.6$ days. The mean gap from reporting the rpoB gene study to reporting the susceptibility was $56{\pm}35$ days. Twenty-eight cases (85%) showed identical results compared with the drug susceptibility results, whereas five cases (15%) showed contradictory results. When compared with the sequencing analysis, of the five cases that showed contradictory results, two had LiP A analysis errors and the remaining three were identical to the sequencing results. The rpoB gene study was of assistance in choosing the appropriate drugs in 28 cases (85%). Conclusions : An rpoB gene study using an LiP A assay was useful in rapidly diagnosing RMP-resistant tuberculosis, which enabled a proper choice of the appropriate drugs in clinical practices. However, an LiPA assay always should be performed in conjunction with microscopy, culture, and susceptibility tests.

  • PDF

Analysis of the under Pavement Cavity Growth Rate using Multi-Channel GPR Equipment (멀티채널 GPR 장비를 이용한 도로하부 공동의 크기 변화 분석)

  • Park, Jeong Jun;Kim, In Dae
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.60-69
    • /
    • 2020
  • Purpose: Cavity growth process monitoring is to periodically monitor changes in common size and topography for general and observational grades to predict the rate of common growth. The purpose of this study is to establish a systematic cavity management plan by evaluating the general and observational class community in a non-destructive method. Method: Using GPR exploration equipment, the acquired surface image and the surrounding status image are analyzed in the GPR probe radargram in depth, profile, and cross section of the location. The exact location is selected using the distance and surrounding markings shown on the road surface of the initial detection cavity, and the test cavity is analyzed by calling the radar at the corresponding location. Result: As a result of monitoring tests conducted at a cavity 30 sites of general and observation grade, nine sites have been recovered. Changes in scale were seen in 21 cavity locations, and changes in size and grade occurred in 13 locations. Conclusion: The under road cavity is caused by various causes such as damage to the burial site, poor construction, soil leakage caused by groundwater leakage, waste and ground vibration. Among them, indirect factors could infer the effects of groundwater and localized rainfall.

Evaluation of Quantitative Image Quality using Frequency and Parameters in the Ultrasound Image (초음파영상에서 주파수와 파라미터를 이용한 정량적 영상평가)

  • Kim, Changsoo;Kang, Se Sik;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.247-253
    • /
    • 2016
  • Ultrasound devices diagnose many disease, which is widely used, can not be standardized quantitative evaluated in order to evaluate sonography image of quality. Therefore, in this papers, aims to get correct image in order to accurate diagnosis by figuring out the appropriate parameter based on each target by measuring distortion which results in the analyzation of the sensitivity of SNR and the histogram of signal by manipulating parameter of 8 mm target in ATS-539 multipurpose phantom. Equipment using Acuson sequoia 512, convex probe and utilizes multi-objective phantom. experiment method is that first you put the phantom on the flat and acquire 85 sheets of image, changing frequency(2,3,4 MHz, harmonic 3, 4, 4.5 MHz), Focus(2, 4, 6 unit), and Dynamic Range(58, 68, 78, 88, 98) for a 8 mm structure. through the Image J program. The sensitivity angle of 8mm target through Image J program is gauged by each separate target SNR and the distorted angle subtract and measure Histogram of background from Histogram of signal and take top 40% from the given result value above. According to parameter variation we found out proper parameter by acquiring SNR of sensitivity and distortion data for aspect of transition. The more this findings have Focus, the lower distortion value and at 4 MHz frequency this result have high SNR and low distortion value. Dynamic Range got an appropriate image on 88 and 98. It is considered on the basis of the experimental data, the probability of disease diagnosis will get higher.