• Title/Summary/Keyword: Multi-plot

Search Result 107, Processing Time 0.034 seconds

An Implementation of Realtime Pitch Analyzer Using MatLab (MatLab를 이용한 실시간 피치분석기 구현)

  • Park Il-Seo;An Hye-Young;Kim Dae-Hyun;Jo Cheol-Woo
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.147-150
    • /
    • 2002
  • This paper describes procedures to implement a real-time pitch analyzer using Matlab. Matlab is a multi-purpose signal-processing tool. Using this tool real-time analysis tool is implemented. To make it real-time we used data acquisition toolbox which comes with Matlab. Autocorrelation method was used as a basic algorithm. The resulting pitch informations are displayed in two different forms, i.e. instantaneous pitch plot and pitch track. V/UV decision is performed using zero crossing rate and energy Informations based on 500 utterances.

  • PDF

Analysis and Reduction of Escalator Vibration Using the Response Surface Methodology (반응 표면법을 이용한 에스컬레이터의 진동 저감에 관한 연구)

  • Lim, Su-Young;Kwon, Yi-Sug;Park, Chan-Jong;Hong, Seong-Wook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.623-628
    • /
    • 2000
  • This paper deals with an analysis and reduction of escalator vibration by using the response surface model. Optimization of the escalator vibration is performed by minimization of the vibration responses which are measured at steps. The response surface models of the factors are constructed by using the experimental data based on the D optimal design method. The multi-objective optimization is also performed by applying desirability function and overlaid contour plot techniques. The optimal solution, which is obtained for a typical escalator system, is applied to reduce the escalator vibration.

  • PDF

Early Detection of Intravenous Infiltration Using Multi-frequency Bioelectrical Impedance Parameters: Pilot Study

  • Kim, Jae-Hyung;Shin, Beum-Joo;Baik, Seung-Wan;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.15-23
    • /
    • 2017
  • In this study, bioelectrical impedance analysis, which has been used to assess an alteration in intracellular fluid (ICF) of the body, was applied to detect intravenous infiltration. The experimental results are described as follows. Firstly, when infiltration occurred, the resistance gradually decreased with time and frequency i.e., the resistance decreased with increasing time, proportional to the amount of infiltrated intravenous (IV) solution. At each frequency, the resistance gradually decreased with time, indicating the IV solution (also blood) accumulated in the extracellular fluid (ECF) (including interstitial fluid). Secondly, the resistance ratio started to increase at infiltration, showing the highest value after 1.4 min of infiltration, and gradually decreased thereafter. Thirdly, the impedance ($Z_C$) of cell membrane decreased significantly (especially at 50 kHz) during infiltration and gradually decreased thereafter. Fourthly, Cole-Cole plot indicated that the positions of (R, $X_C$) shifted toward left owing to infiltration, reflecting the IV solution accumulated in the ECF. The resistance ($R_0$) at zero frequency decreased continuously over time, indicating that it is a vital impedance parameter capable of detecting early infiltration during IV infusion. Finally, the mechanism of the current flowing through the ECF, cell membrane, and ICF in the subcutaneous tissues was analyzed as a function of time before and after infiltration, using an equivalent circuit model of the human cell. In conclusion, it was confirmed that the infiltration could be detected early using these impedance parameters during the infusion of IV solution.

Determining the Required Vitamin D Level for Bone Health Based on Bone Turnover Markers

  • Ismail, Tuan Salwani Tuan;Muda, Bayani Che;Rosdi, Roznie Aida Mohd;Zainuddin, Azalina;Isa, Salbiah;Mustapaha, Zulkarnain
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.337-344
    • /
    • 2017
  • To date, no clear threshold that has been established for defining an adequate store of vitamin D for bone health. Therefore, this study aims to determine the required level of vitamin D to maintain a healthy skeleton based on bone remodelling process among healthy adult population. This was a cross sectional study, involving a healthy adult population in Kota Bharu, Malaysia, aged 18~50 years. We measured serum 25(OH)D (vitamin D), serum parathyroid hormone (PTH), serum C-terminal telopeptide of type 1 collagen (CTX), and Procollagen 1 Intact N-Terminal (P1NP) in 120 healthy adults selected via multi stage sampling (64 males, 56 females) from 6 subdistricts in Kota Bharu. The mean level of 25(OH)D was 23.50 (${\pm}8.74$) nmol/L. There was a significant difference of the vitamin D level between genders ($26.81{\pm}8.3nmol/L$ vs $19.72{\pm}7.68nmol/L$ in males and females respectively) (p value<0.001). More than 50% of female subjects had 25(OH)D less than 20 nmol/L, while only 20.3% of male subjects had 25(OH)D below 20 nmol/L. Based on the LOESS plot, the bone turnover markers showed a plateauing result, at the 25(OH)D level of 35 nmol/L for CTX and 20 nmol/L for P1NP. Contrastingly, PTH showed a step rise in the 25(OH)D level of 20 nmol/L. Based on the LOESS plot for CTX, P1NP and PTH versus 25(OH)D, level of vitamin D between 20 to 35 nmol/L is recommended to maintain healthy skeleton.

Bioelectrical Impedance Analysis at Popliteal Regions of Human Body using BIMS

  • Kim, J.H.;Kim, S.S.;Kim, S.H.;Baik, S.W.;Jeon, G.R.
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • Bioelectrical impedance (BI) at popliteal regions was measured using a bioelectrical impedance measurement system (BIMS), which employs the multi-frequency and the two-electrode method. Experiments were performed as follows. First, a constant AC current of $800{\mu}A$ was applied to the popliteal regions (left and right) and the BI was measured at eight different frequencies from 10 to 500 kHz. When the applied frequency greater than 50 kHz was applied to human's popliteal regions, the BI was decreased significantly. Logarithmic plot of impedance vs. frequency indicated two different mechanisms in the impedance phenomena before and after 50 kHz. Second, the relationship between resistance and reactance was obtained with respect to the applied frequency using BI (resistance and reactance) acquired from the popliteal regions. The phase angle (PA) was found to be strongly dependent on frequency. At 50 kHz, the PA at the right popliteal region was $7.8^{\circ}$ slightly larger than $7.6^{\circ}$ at the left popliteal region. Third, BI values of extracellular fluid (ECF) and intracellular fluid (ICF) were calculated using BIMS. At 10 kHz, the BI values of ECF at the left and right popliteal regions were $1664.14{\Omega}$ and $1614.08{\Omega}$, respectively. The BI values of ECF and ICF decreased sharply in the frequency range of 10 to 50 kHz, and gradually decreased up to 500 kHz. Logarithmic plot of BI vs. frequency shows that the BI of ICF decreased noticeably at high frequency above 300 kHz because of a large decrease in the capacitance of the cell membrane.

Performance Analysis of Liquid Pintle Thruster Using Quasi-one-dimensional Multi-phase Reaction Flow: Part II. Thruster Performance Characteristics (준 일차원 다상 반응유동 기법을 이용한 케로신/과산화수소 액체 핀틀 추력기 성능해석 연구: Part II 추력기 성능 특성)

  • Kang, Jeongseok;Bok, Janghan;Sung, Hong-Gye;Kwon, Minchan;Heo, JunYoung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.6
    • /
    • pp.78-84
    • /
    • 2020
  • The performance of pintle thruster is analyzed by using the pintle thruster performance analysis model which integrating the element models introduced in Part I. To verify the performance analysis, the results of the developed program are compared with the experimental data of kerosene/hydrogen peroxide liquid pintle thrusters. Based on the results, the characteristics of the pintle thruster are analyzed. The sensitivity analysis is performed to investigate the effect of thruster shape and operation parameters on performance characteristics using both OAT and scatter plot methods. The four performance parameters such as droplet diameter, film flow rate, O/F ratio, and nozzle throat diameter are evaluated to investigate their effects on characteristic speed, combustor pressure, and specific thrust.

Verifying Applicability of Multi-Timescale Rainfall Data from CHIRPS Satellite (다중시간 규모의 CHIRPS 위성 강우자료에 대한 활용성 검증)

  • Minseok Kim;Kyunghun Kim;Seong Cheol Shin;Soojun Kim;Hung Soo Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.192-192
    • /
    • 2023
  • 우량계는 강우 자료를 수집하는 전통적인 방법 중 하나로, 연속적이고 직접적인 설치가 가능하다. 하지만 지형적 특성에 영향을 받아 강우량을 과소 측정하는 문제점이 있다. 이러한 문제를 해결하기 위해 국지적인 호우, 강우 이동 및 강우 상황 등을 파악할 수 있는 레이더를 이용한 강우 측정이 활용된다. 하지만 레이더 기반 측정 또한 우량계와 마찬가지로 과소 측정하는 문제점이 있다. 측정 한계를 극복하기 위해 최근에는 위성 기반 강우 자료를 사용하고 있다. 위성 기반의 강우 자료는 측정이 어려운 장소에서도 강우량의 수집이 가능하며, 지표 변화를 관측하여 강우 측정의 정확도를 높일 수 있다. 고화질 위성 자료인 CHIRPS (Climate Hazards Group InfraRed Precipitation with Stations) 자료는 미국 국제개발처, 항공우주국, 해양 대기청의 지원으로 1980년부터 현재까지 전 지구적 (50°S-50°N, 180°E-180°W) 0.05° × 0.05°의 해상도를 가진 강우량 데이터를 개발하였다. 본 연구에서는 전국 54개 ASOS (Automated Synpotic Observing System)에서 관측한 월 단위 및 일 단위 강우 자료를 기준으로 CHIRPS 강우 자료를 비교하였다. 또한, 다른 위성 강우 자료들 (APHRODITE (Asian Precipitation Highly Resolved Observation Data Integration Towards Evaluation), CMORPH (Climate Prediction Cneter morphing method))과도 비교하여 국내 적용성을 확인하였다. 강우 자료의 정확도를 비교하기 위해서 Box-plot, RMSE (Root Mean Squared Error) 등을 산정하였으며, 강우 발생 일을 비교하고자 오차 행렬을 활용하였다. 비교 결과를 통해서 CHIRPS 강우 자료가 다른 위성 강우 자료들에 비해서 국내 적용성이 높은 것을 확인할 수 있었으며, 추후 국내 수문학 연구에서 기초자료로서 활용될 수 있을 것으로 판단된다.

  • PDF

Surface Treatment of Multi-walled Carbon Nanotubes for Increasing Electric Double-layer Capacitance (다중벽 탄소나노튜브의 표면처리에 따른 전기이중층 커패시터의 특성)

  • Kim, Ji-Il;Kim, Ick-Jun;Park, Soo-Jin
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.1
    • /
    • pp.93-98
    • /
    • 2010
  • In this work, the electrochemical properties of surface treated multi-walled carbon nanotubes (MWNTs) were studied. Nitrogen and oxygen functional groups of the MWNTs were introduced by urea and acidic treatment, respectively. The surface functional groups of the MWNTs were confirmed by X-ray photoelectron spectroscopy (XPS) measurements and zeta-potential method. The characteristics of $N_2$ adsorption isotherm at 77 K, specific surface area, and total pore volumes were investigated by BET eqaution, BJH method and t-plot method. Electrochemical properties of the functionalized MWNTs were accumulated by cyclic voltammetry at the scan rates of 50 $mVs^{-1}$ and 100 $mVs^{-1}$ in 1M $H_2SO_4$ as electrolytes. As a result, the functionalized MWNTs led to an increase of capacitance as compared with pristine MWNTs. It was found that the increase of capacitance for urea treated MWNTs was attributed to the increase in density of surface functional groups, resulting in improving the wettability between electrode materials and charge species.

Study of the Valence and Rydberg States of a Lithium Dimer by the Multi-reference Configuration-interaction Method

  • Lee, Chun-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.5
    • /
    • pp.1422-1432
    • /
    • 2014
  • Convergent all-electron multi-reference configuration-interaction (MRCI) calculations are performed for a lithium dimer with Kaufmann's Rydberg basis functions. A comparison of the results of these calculations with those of the effective core potential/core polarization potential (ECP/CPP) method and experimental data reveals the deficiency of the all-electron ab initio method. The deficiency is related to the mere 51.9% attainment of electron correlation for the ground state. The percent attainment of electron correlation for the first excited state is slightly better than that for the ground state, preventing us from obtaining better agreements with experimental data by means of increasing the size of basis sets. The Kaufmann basis functions are then used with the ECP/CPP method to obtain the accurate convergent potential energy curves for the $^1\prod_u$ states correlated to Li(2p) + Li(2p) and Li(2s) + Li(n = 2, 3, 4). Quantum defect curves (QDCs) calculated for both the $X^2\sum_g$ and 1 $^2\prod_u$ states of the $Li{_2}^+$ ion and the Lu-Fano plot reveal a strong series-series interaction between the two $2snp{\pi}$ and $2pnp{\pi}$ Rydberg series. The QDCs are then used to resolve assignment problems in the literature. The reassignments, performed by Jedrzejewski-Szemek et al., of the dissociation product of the D $^1\prod$ state from (2s+3d) to (2s+3p) and that of the 6 $^1\prod_u$ from (2s+4d) to (2s+4p) are found to be incorrect. It may be more natural to assign their $2snp{\pi}$ Rydberg series as a $2snd{\pi}$ series. The state, assigned as 5p $^1\prod_u$ by Ross et al. and 4d $^1\prod$ by Jedrzejewski-Szemek et al., is assigned as the 7 $^1\prod_u$ state, correlated to the Li(2s) + Li(4f) limit.

Hydrogeochemical and geostatistical study of shallow alluvial groundwater in the Youngdeok area

  • Kim, Nam-Jin;Yun, Seong-Taek;Kwon, Man-Jae;Kim, Hyoung-Soo;Kim, Chang-Hoon;Koh, Yong-Kwon
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.232-236
    • /
    • 2000
  • Multi-regression statistical analyses were applied for the water quality data of shallow alluvial ground water (n = 47) collected from the Youngdeok area, in order to quantitatively generalize the natural (non-anthropogenic) causes of regional water quality variation. Seven samples having the high contamination index ( $C_{a}$ > 3) reflect the striong effects by anthropogenic activity. Most of the alluvial groundwaters have acquired their quality primarily due to the dissolution of carbonate minerals. The results of multi-regression analysis show that chlorine is mainly derived from seawater effect. Sulfur isotopic compositions of dissolved sulfur and the S $O_4$/Cl ratio also enable us to discriminate the samples (n = 18) which are affected by atmospheric input of marine aerosol (sea-spray) and also by mixing between freshwater and seawater. Hydrogen and oxygen isotope data of the samples collected lie close to the local meteoric water line obtained from nearby Pohang city but has lower slope (5.45) on the $\delta$D-$^{18}$ O plot, indicating that alluvial groundwater was recharged from infiltrated meteoric water which has undergone some degree of kinetic evaporation. The estimated initial isotopic composition of the recharged water ($\delta$D = -74.8$^{0}$ /$_{00}$, $\delta$$^{18}$ O = -10.8$^{[-1000]}$ /$_{[-1000]}$ ) suggests that the alluvial ground water recharge largely occurs during summer storm events.s.s.

  • PDF