• Title/Summary/Keyword: Multi-physics system

Search Result 179, Processing Time 0.031 seconds

Enhancing value of quality assurance rounds in improving radiotherapy management: a retrospective analysis from King Hussein Cancer Center in Jordan

  • Khader, Jamal K.;Al-Mousa, Abdelatif M.;Mohamad, Issa A.;Abuhijlih, Ramiz A.;Al-Khatib, Sondos A.;Alnsour, Anoud Z.;Asha, Wafa A.;Ramahi, Shada W.;Hosni, Ali A.;Abuhijla, Fawzi J.
    • Radiation Oncology Journal
    • /
    • v.37 no.1
    • /
    • pp.60-65
    • /
    • 2019
  • Purpose: The quality assurance (QA) chart rounds are multidisciplinary meetings to review radiation therapy (RT) treatment plans. This study focus on describing the changes in RT management based on QA round reviews in a single institution. Materials and Methods: After 9 full years of implementation, a retrospective review of all patients whose charts passed through departmental QA chart rounds from 2007 to 2015. The reviewed cases were presented for RT plan review; subcategorized based on decision in QA rounds into: approved, minor modifications or major modifications. Major modification defined as any substantial change which required patient re-simulation or re-planning prior to commencement of RT. Minor modification included treatment plan changes which didn't necessarily require RT re-planning. Results: Overall 7,149 RT treatment plans for different anatomical sites were reviewed at QA rounds. From these treatment plans, 6,654 (93%) were approved, 144 (2%) required minor modifications, while 351 (5%) required major modifications. Major modification included changes in: selected RT dose (96/351, 27%), target volume definition (127/351, 36%), organs-at-risk contouring (10/351, 3%), dose volume objectives/constraints criteria (90/351, 26%), and intent of treatment (28/351, 8%). The RT plans which required major modification according to the tumor subtype were as follows: head and neck (104/904, 12%), thoracic (12/199, 6%), gastrointestinal (33/687,5%), skin (5/106, 5%), genitourinary (16/359, 4%), breast (104/2387, 4%), central nervous system (36/846, 4%), sarcoma (11/277, 4%), pediatric (7/251, 3%), lymphoma (10/423, 2%), gynecological tumors (2/359, 1%), and others (11/351, 3%). Conclusion: Multi-disciplinary standardized QA chart rounds provide a comprehensive and an influential method on RT plans and/or treatment decisions.

Simulation of underwater echo reduction using miniaturized Helmholtz resonators (소형화된 헬름홀츠 공진기를 이용한 수중 반향음 감소해석 모의실험)

  • Park, SungJun;Kim, Jedo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.1
    • /
    • pp.67-72
    • /
    • 2019
  • In this study, we investigate the echo reduction performance of miniaturinzed Helmholtz resonators using smaller than wavelength acoustic metamaterial structures. The Helmholtz resonators are formed using air structures which exhibit large impedance mismatch with the surrounding underwater environment. Using the multi-physics software package, we find that significant reduction in the sonar signature is expected and frequency tailoring is possible by controlling the degree of space coiling and inner volume of the resonators. We find that for the basic Helmholtz resonators, up to 7 dB reduction in echo is expected at 10,000 Hz while when the miniaturized Helmoholtz resonators are used, up to 14 dB reduction in echo is expected at 5,000 Hz. In addition, frequency tailoring is demonstrated by varying the internal volume of the Helmholtz resonators and broadband characteristic is shown using superposition of various degree of space coiled structures. Through this study we investigate the effectiveness of the miniaturized Helmholtz resonators formed using air structures and the echo reduction results show promisses in the application of achieving underwater stealth.

Analysis of the potential landslide hazard after wildfire considering compound disaster effect (복합재해 영향을 고려한 산불 후 산사태 잠재적 피해 위험도 분석)

  • Lee, Jong-Ook;Lee, Dong-Kun;Song, Young-Il
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.22 no.1
    • /
    • pp.33-45
    • /
    • 2019
  • Compound disaster is the type that increases the impact affected by two or more hazard events, and attention to compound disaster and multi-hazards risk is growing due to potential damages which are difficult to predict. The objective of this study is to analyze the possible impacts of post-fire landslide scenario quantitatively by using TRIGRS (Transient Rainfall Infiltration and Grid-Based Regional Slope-Stability Analysis), a physics-based landslide model. In the case of wildfire, soil organic material and density are altered, and saturated hydraulic conductivity decrease because of soil exposed to high temperature. We have included the change of soil saturated hydraulic conductivity into the TRIGRS model through literature review. For a case study, we selected the area of $8km^2$ in Pyeongchang County. The landslide modeling process was calibrated before simulate the post-wildfire impact based on landslide inventory data to reduce uncertainty. As a result, the mean of the total factor of safety values in the case of landslide was 2.641 when rainfall duration is 1 hour with rainfall intensity of 100mm per day, while the mean value for the case of post-wildfire landslide was lower to 2.579, showing potential landslide occurrence areas appear more quickly in the compound disaster scenario. This study can be used to prevent potential losses caused by the compound disaster such as post-wildfire debris flow or landslides.

Study on heat transfer characteristics and structural parameter effects of heat pipe with fins based on MOOSE platform

  • Xiaoquan Chen;Peng Du;Rui Tian;Zhuoyao Li;Hongkun Lian;Kun Zhuang;Sipeng Wang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.364-372
    • /
    • 2023
  • The space reactor is the primary energy supply for future space vehicles and space stations. The radiator is one of the essential parts of a space reactor. Therefore, the research on radiators can improve the heat dissipation power, reduce the quality of radiators, and make the space reactor smaller. Based on MOOSE multi-physics numerical calculation platform, a simulation program for the combination of heat pipe and fin at the end of heat pipe radiator is developed. It is verified that the calculation result of this program is accurate and the calculation speed is fast. Analyze the heat transfer characteristics of the combination with heat pipe and fin, and obtain its internal temperature field. Based on the calculation results, the influence of structural parameters on the heat dissipation power is analyzed. The results show that when the fin width is 0.25 m, fin thickness is 0.002 m, condensing section length is 0.5425 m and heat pipe radius is 0.014 m, the power-mass ratio is the highest. When the temperature is 700K-900K, the heat dissipation power increases 41.12% for every 100K increase in the operating temperature. Smaller fin width and thinner fin thickness can improve the power-mass ratio and reduce the radiator quality.

Geometric Calibration of Cone-beam CT System for Image Guided Proton Therapy (영상유도 양성자치료를 위한 콘빔 CT 재구성 알고리즘: 기하학적 보정방법에 관한 연구)

  • Kim, Jin-Sung;Cho, Min-Kook;Cho, Young-Bin;Youn, Han-Bean;Kim, Ho-Kyung;Yoon, Myoung-Geun;Shin, Dong-Ho;Lee, Se-Byeung;Lee, Re-Na;Park, Sung-Yong;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.209-218
    • /
    • 2008
  • According to improved radiation therapy technology such as IMRT and proton therapy, the accuracy of patient alignment system is more emphasized and IGRT is dominated research field in radiation oncology. We proposed to study the feasibility of cone-beam CT system using simple x-ray imaging systems for image guided proton therapy at National Cancer Center. 180 projection views ($2,304{\times}3,200$, 14 bit with 127 ${\mu}m$ pixel pitch) for the geometrical calibration phantom and humanoid phantoms (skull, abdomen) were acquired with $2^{\circ}$ step angle using x-ray imaging system of proton therapy gantry room ($360^{\circ}$ for 1 rotation). The geometrical calibration was performed for misalignments between the x-ray source and the flat-panel detector, such as distances and slanted angle using available algorithm. With the geometrically calibrated projection view, Feldkamp cone-beam algorithm using Ram-Lak filter was implemented for CBCT reconstruction images for skull and abdomen phantom. The distance from x-ray source to the gantry isocenter, the distance from the flat panel to the isocenter were calculated as 1,517.5 mm, 591.12 mm and the rotated angle of flat panel detector around x-ray beam axis was considered as $0.25^{\circ}$. It was observed that the blurring artifacts, originated from the rotation of the detector, in the reconstructed toomographs were significantly reduced after the geometrical calibration. The demonstrated CBCT images for the skull and abdomen phantoms are very promising. We performed the geometrical calibration of the large gantry rotation system with simple x-ray imaging devices for CBCT reconstruction. The CBCT system for proton therapy will be used as a main patient alignment system for image guided proton therapy.

  • PDF

Development of Two-dimensional Prompt-gamma Measurement System for Verification of Proton Dose Distribution (이차원 양성자 선량 분포 확인을 위한 즉발감마선 이차원분포 측정 장치 개발)

  • Park, Jong Hoon;Lee, Han Rim;Kim, Chan Hyeong;Kim, Sung Hun;Kim, Seonghoon;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.42-51
    • /
    • 2015
  • In proton therapy, verification of proton dose distribution is important to treat cancer precisely and to enhance patients' safety. To verify proton dose distribution, in a previous study, our team incorporated a vertically-aligned one-dimensional array detection system. We measured 2D prompt-gamma distribution moving the developed detection system in the longitudinal direction and verified similarity between 2D prompt-gamma distribution and 2D proton dose distribution. In the present, we have developed two-dimension prompt-gamma measurement system consisted of a 2D parallel-hole collimator, 2D array-type NaI(Tl) scintillators, and multi-anode PMT (MA-PMT) to measure 2D prompt-gamma distribution in real time. The developed measurement system was tested with $^{22}Na$ (0.511 and 1.275 MeV) and $^{137}Cs$ (0.662 MeV) gamma sources, and the energy resolutions of 0.511, 0.662 and 1.275 MeV were $10.9%{\pm}0.23p%$, $9.8%{\pm}0.18p%$ and $6.4%{\pm}0.24p%$, respectively. Further, the energy resolution of the high gamma energy (3.416 MeV) of double escape peak from Am-Be source was $11.4%{\pm}3.6p%$. To estimate the performance of the developed measurement system, we measured 2D prompt-gamma distribution generated by PMMA phantom irradiated with 45 MeV proton beam of 0.5 nA. As a result of comparing a EBT film result, 2D prompt-gamma distribution measured for $9{\times}10^9$ protons is similar to 2D proton dose distribution. In addition, the 45 MeV estimated beam range by profile distribution of 2D prompt gamma distribution was $17.0{\pm}0.4mm$ and was intimately related with the proton beam range of 17.4 mm.

Prediction of Target Motion Using Neural Network for 4-dimensional Radiation Therapy (신경회로망을 이용한 4차원 방사선치료에서의 조사 표적 움직임 예측)

  • Lee, Sang-Kyung;Kim, Yong-Nam;Park, Kyung-Ran;Jeong, Kyeong-Keun;Lee, Chang-Geol;Lee, Ik-Jae;Seong, Jin-Sil;Choi, Won-Hoon;Chung, Yoon-Sun;Park, Sung-Ho
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.132-138
    • /
    • 2009
  • Studies on target motion in 4-dimensional radiotherapy are being world-widely conducted to enhance treatment record and protection of normal organs. Prediction of tumor motion might be very useful and/or essential for especially free-breathing system during radiation delivery such as respiratory gating system and tumor tracking system. Neural network is powerful to express a time series with nonlinearity because its prediction algorithm is not governed by statistic formula but finds a rule of data expression. This study intended to assess applicability of neural network method to predict tumor motion in 4-dimensional radiotherapy. Scaled Conjugate Gradient algorithm was employed as a learning algorithm. Considering reparation data for 10 patients, prediction by the neural network algorithms was compared with the measurement by the real-time position management (RPM) system. The results showed that the neural network algorithm has the excellent accuracy of maximum absolute error smaller than 3 mm, except for the cases in which the maximum amplitude of respiration is over the range of respiration used in the learning process of neural network. It indicates the insufficient learning of the neural network for extrapolation. The problem could be solved by acquiring a full range of respiration before learning procedure. Further works are programmed to verify a feasibility of practical application for 4-dimensional treatment system, including prediction performance according to various system latency and irregular patterns of respiration.

  • PDF

The properties of AlGaN epi layer grown by HVPE (HVPE에 의해 성장된 AlGaN epi layer의 특성)

  • Jung, Se-Gyo;Jeon, Hun-Soo;Lee, Gang-Seok;Bae, Seon-Min;Yun, Wi-Il;Kim, Kyoung-Hwa;Yi, Sam-Nyung;Yang, Min;Ahn, Hyung-Soo;Kim, Suck-Whan;Yu, Young-Moon;Cheon, Seong-Hak;Ha, Hong-Ju
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.1
    • /
    • pp.11-14
    • /
    • 2012
  • The AlGaN layer has direct wide bandgaps ranging from 3.4 to 6.2 eV. Nowadays, it is becoming more important to fabricate optical devices in an UV region for the many applications. The high quality AlGaN layer is necessary to establish the UV optical devices. However, the growth of AlGaN layer on GaN layer is difficult due to the lattice mismatch and difference thermal expansion coefficient between GaN layer and AlGaN layer. In this paper, we attempted to grow the LED structure on GaN template by mixed-source HVPE method with multi-sliding boat system. We tried to find the optical and lattice transition of active layer by control the Al content in mixed-source. For the growth of epi layer, the HCl and $NH_3$ gas were flowed over the mixed-source and the carrier gas was $N_2$. The temperature of source zone and growth zone was stabled at 900 and $1090^{\circ}C$, respectively. After the growth, we performed the x-ray diffraction (XRD) and electro luminescence (EL) measurement.

On the Study of Developement for Urban Meteorological Service Technology (도시기상서비스 기술 개발에 관한 연구)

  • Choi, Young-Jean;Kim, Chang-Mo;Ryu, Chan-Su
    • Journal of Integrative Natural Science
    • /
    • v.4 no.2
    • /
    • pp.149-157
    • /
    • 2011
  • Urbanization of the world's population has given rise to more than 450 cities around the world with populations in excess of 1 million (megacity) and more than 25 so-called metacities with populations over 10 million (Brinkhoff, 2010). The United States today has a total resident population of more than 308,500,000 people, with 81 percent residing in cities and suburbs as of mid - 2005 (UN, 2008). Urban meteorology is the study of the physics, dynamics, and chemistry of the interactions of Earth's atmosphere and the urban built environment, and the provision of meteorological services to the populations and institutions of metropolitan areas. While the details of such services are dependent on the location and the synoptic climatology of each city, there are common themes, such as enhancing quality of life and responding to emergencies. Experience elsewhere (e.g., Shanghai, Helsinki, Tokyo, Seoul, etc.) shows urban meteorological support is a key part of an integrated or multi-hazard warning system that considers the full range of environmental challenges and provides a unified response from municipal leaders. Urban meteorology has come to require much more than observing and forecasting the weather of our cities and metropolitan areas. Forecast improvement as a function of more and better observations of various kinds and as a function of model resolution, larger ensembles, predicted probability distributions; Responses of emergency managers, government officials, and users to improved and probabilistic forecasts; Benefits of improved forecasts in reduction of loss of life, property damage, and other adverse effects. A national initiative to enhance urban meteorological services is a high-priority need for a wide variety of stakeholders, including the general, commerce and industry, and all levels of government. Some of the activities of such an initiative include: conducting basic research and development; prototyping and other activities to enable very--short and short range predictions; supporting and improving productivity and efficiency in commercial and industrial sectors; and urban planning for long term sustainability. In addition urban test-beds are an effective means for developing, testing, and fostering the necessary basic and applied meteorological and socioeconomic research, and transitioning research findings to operations. An extended, multi-year period of continuous effort, punctuated with intensive observing and forecasting periods, is envisioned.

Intensity Modulated Radiation Therapy Commissioning and Quality Assurance: Implementation of AAPM TG119 (세기조절방사선치료(IMRT)의 Commissioning 및 정도관리: AAPM TG119 적용)

  • Ahn, Woo-Sang;Cho, Byung-Chul
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.99-105
    • /
    • 2011
  • The purpose of this study is to evaluate the accuracy of IMRT in our clinic from based on TG119 procedure and establish action level. Five IMRT test cases were described in TG119: multi-target, head&neck, prostate, and two C-shapes (easy&hard). There were used and delivered to water-equivalent solid phantom for IMRT. Absolute dose for points in target and OAR was measured by using an ion chamber (CC13, IBA). EBT2 film was utilized to compare the measured two-dimensional dose distribution with the calculated one by treatment planning system. All collected data were analyzed using the TG119 specifications to determine the confidence limit. The mean of relative error (%) between measured and calculated value was $1.2{\pm}1.1%$ and $1.2{\pm}0.7%$ for target and OAR, respectively. The resulting confidence limits were 3.4% and 2.6%. In EBT2 film dosimetry, the average percentage of points passing the gamma criteria (3%/3 mm) was $97.7{\pm}0.8%$. Confidence limit values determined by EBT2 film analysis was 3.9%. This study has focused on IMRT commissioning and quality assurance based on TG119 guideline. It is concluded that action level were ${\pm}4%$ and ${\pm}3%$ for target and OAR and 97% for film measurement, respectively. It is expected that TG119-based procedure can be used as reference to evaluate the accuracy of IMRT for each institution.