• Title/Summary/Keyword: Multi-phase extraction

Search Result 39, Processing Time 0.028 seconds

다중상 추출조건에서 L-NAPL의 토양이동 특성

  • 김성용;이인원;이승우;장윤영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.282-284
    • /
    • 2003
  • Multi-phase extraction of LNAPLs not only floating on groundwater but also captured in soil pores was studied in a simulated soil system. The extraction rate of LNAPL under the MPE conditions was much higher than the rate under usual hydraulic gradient conditions. The WE might be especially useful for recovery of oils in fine-textured soils such as clay-dominant soils. The vacuum-enhanced transport of LNAPL in soils also depended on the properties of LNAPL such as viscosity and density as well as soil textures.

  • PDF

Absorption of d-Limonene in Orange Juice into a Laminated Food Package Studied with a Solid Phase Micro-extraction Method

  • Lee, Hahn-Bit;Yang, Hee-Jae;Min, Sea-C.
    • Food Engineering Progress
    • /
    • v.14 no.4
    • /
    • pp.354-358
    • /
    • 2010
  • The methods for determining the diffusion parameters for the diffusion of d-limonene, a major volatile compound of orange juice, through a multi-layered food packaging material and predicting its absorption into the packaging material have been investigated. The packaging material used was the 1.5-mm thick multi-layered packaging material composed of high impact polystyrene (HIPS), polyvinylidene chloride (PVDC), and low density polyethylene (LDPE). Orange juice was placed in a cell where volatiles were absorbed in the sample package and kept at $23{\pm}2^{\circ}C$ for 72 hr. The d-limonene absorbed in a 1.5-mm thick multi-layered food packaging material was analyzed by a solid phase micro-extraction (SPME). The absorption parameters for the absorption of d-limonene in the packaging material were determined and absorption of d-limonene into the packaging material was predicted using absorption storage data. The SPME desorption at $60^{\circ}C$ for 1 hr resulted in the most sensitive and reproducible results. The diffusion coefficients of d-limonene in the packaging material and the partition coefficient at $23{\pm}2^{\circ}C$ were approximately $1-2{\times}10^{12}m^2$/s and 0.03, respectively. The absorption profile no earlier than 30 hr was fit well by a model derived from the Fick's law.

A method for underwater image analysis using bi-dimensional empirical mode decomposition technique

  • Liu, Bo;Lin, Yan
    • Ocean Systems Engineering
    • /
    • v.2 no.2
    • /
    • pp.137-145
    • /
    • 2012
  • Recent developments in underwater image recognition methods have received large attention by the ocean engineering researchers. In this paper, an improved bi-dimensional empirical mode decomposition (BEMD) approach is employed to decompose the given underwater image into intrinsic mode functions (IMFs) and residual. We developed a joint algorithm based on BEMD and Canny operator to extract multi-pixel edge features at multiple scales in IMFs sub-images. So the multiple pixel edge extraction is an advantage of our approach; the other contribution of this method is the realization of the bi-dimensional sifting process, which is realized utilizing regional-based operators to detect local extreme points and constructing radial basis function for curve surface interpolation. The performance of the multi-pixel edge extraction algorithm for processing underwater image is demonstrated in the contrast experiment with both the proposed method and the phase congruency edge detection.

Simultaneous Determination of the Water Soluble Vitamins in Multi-Nutrient Tablets by Reversed-Phase High-Performance Liquid Chromatography

  • Kim, Hyung-Soo;Jang, Duck-Kyu;Woo, Dong-Kyun;Woo, Kang-Lyung
    • Preventive Nutrition and Food Science
    • /
    • v.7 no.1
    • /
    • pp.12-17
    • /
    • 2002
  • Simultaneous determination of nine water-soluble vitamins contained in multi-nutrient tablets was carried out by reversed phase high-performance liquid chromatography (RP-HPLC) equipped with analytical $C_{18}$ column and UV (270 nm) detector. Those standard vitamins were successfully separated within 23 minutes by gradient elution with solvent A (0.5 M potassium phosphate monobasic) and solvent B (0.25 M potassium phosphate monobasic-methanol, 1:1). Calibration curves showed good linealities with correlation coefficients (> 0.92) in tested ranged respectively. The detection limits were considered to be 2.1 ng for ascorbic acids 60 ng for Vit B$_{6}$ 3 ng for p-aminobenzoic acid, 9 ng for niacinamide, 9 ng for thiamin, 5.0 ng for folic acid and 1.5 ng for riboflavin at 0.05 a.u.f.s. Solid phase extraction through Sep-Pak (C$_{18}$ ) cartridge was successfully applied for purification of water soluble vitamins in commercial multi-nutrient tablets.ts.

3D Object Extraction Algorithm Based on Hierarchical Phase Using Fast Fourier Transform (고속 푸리에 변환을 이용한 계층적 위상기반 3차원 객체 추출 기법)

  • 한규필;이채수;박양우;엄태억
    • Proceedings of the IEEK Conference
    • /
    • 2001.06c
    • /
    • pp.145-148
    • /
    • 2001
  • This paper presents a phase-based stereo matching algorithm in order to efficiently extract 3-dimensional objects from two 2D images. Conventional phase-based methods, especially using windowed Fourier phases, inherit good properties in the cage of hierarchical approaches, because they basically use a multi-resolution phase map. On the contrary, their computational cost is too heavy. Therefore, a fast hierarchical approach, using multi-resolution phase-based strategy and reducing redundancies of phase calculations based on FFT concept is proposed in this paper. In addition, a structural matching algorithm on the phase domain is presented to improve the matching quality. In experimental results. it is shown that the computation loads are considerably reduced about 8 times and stable outputs are obtained from various images.

  • PDF

Optical Binary Phase Extraction Joint Transform Correlator System for Improving the Correlation Discrimination (상관신호의 판별력 개선을 위한 광 BPEFTC 시스템)

  • 이상이;김은수
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.6
    • /
    • pp.78-87
    • /
    • 1994
  • In this paper, a binary phase extraction joiont transform correlator (BPEJTC)system is proposed as a new phase-type optical correlator in which the correlation errors and DC component are dramtically reduced and optical efficiency and correlation performance are also improved by reconstructing the joint transform power spectrum (JTPS) of the conventional joint transform correlator (JTC)system form which the autocorrelation and crosscorrelation siganls generated in each self-plane are removed, and the binary phase function is extracted from the phase value of the reconstructed JTPS. Through some computer simulation and optical experimental results, the possibility of the implementation of the real-time multi-target tracking and recognition system is also suggested.

  • PDF

hardware implementation of multi-target tracking system based on binary phase extraction JTC (BPEJTC를 이용한 다중표적 추적시스템의 하드웨어 구현)

  • 이승현;이상이;류충상;차광훈;서춘원;김은수
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.10
    • /
    • pp.152-159
    • /
    • 1996
  • We have designed and implemented an optoelectronic hardware of binary phase extraction joint transform correlator (BPEJTC) which provides higher peak-to-sidelobe ratio than many other versions of JTC that has been published so far and does not produce correlation peaks due to intra-class association, to construct a multi-target tracking system. The digital processing unit controlling the entire system plays the part of modifying and binarizing the joint transform power spectrum (JTPS) and the optical processing unit is mainly used to take fourier transform operations. Some experimental results conducted by designed system along with its architecture showed the processing rate of 6 frames per second, thereby the potential applicability of the proposed system to real-time multitarget tracking system is given.

  • PDF

Spectrometric Determination of Rhodamine B in Chili Powder After Molecularly Imprinted Solid Phase Extraction

  • Liu, Xiuying;Zhang, Xuan;Zhou, Qian;Bai, Bing;Ji, Shujuan
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3381-3386
    • /
    • 2013
  • This paper reports a method using molecularly imprinted polymers that are grafted onto the surface of carboxyl-modified multi-walled carbon nanotubes as the solid-phase extraction adsorbents to detect Rhodamine B in chili powder samples. The polymers were characterized by FTIR and TGA. Various parameters which probably influence efficiency of extraction were optimized. The analytical parameters such as precision, accuracy and linear working range were also determined in optimal experimental conditions. And the proposed method was applied to analysis of Rhodamine B in chili powder samples. The limits of detection and quantification were 2.57 and 8.56 ${\mu}g/g$, respectively. The recoveries for analytes were higher than 95% and relative standard deviation values were found to be in the range of 0.83-4.15%. This method was successfully applied for the determination of Rhodamine B.

High throughput automated 96-well solid-phase extraction and liquid chromatography-tandem mass spectrometric analysis of beraprost in human plasma

  • Chang, Kyu-Young;Kim, Ho-Hyun;Lee, Hee-Joo;Lee, Kyung-Ryul
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.224.1-224.1
    • /
    • 2003
  • A sensitive and selective liquid chromatographic method coupled with tandem mass spectrometry (LC-MS/MS) was developed for the determination of beraprost in human plasma. Plasma samples were transferred into 96-well OASIS HLB extraction plate using an automated sample handling system and the drugs were eluted with methanol. The eluents were then evaporated and reconstituted with water. All sample transfer and solid-phase extraction (SPE) was automated through the application of both the PerkinElmer MultiPROBE II HT and TOMTEC Quadra 96 workstation. (omitted)

  • PDF

3D Object Extraction Algorithm Based on Hierarchical Approach Using Reduced Windowed Fourier Phase (간소화된 윈도우 푸리에 위상을 이용한 계층적 접근기반의 3차원 객체 추출 기법)

  • Min, Gak;Han, Kyu-Phil;Lee, Ky-Soo;Ha, Yeong-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.8A
    • /
    • pp.779-785
    • /
    • 2002
  • This paper presents a phase-based stereo matching algorithm in order to efficiently extract 3-dimensional objects from two 2D images. Conventional phase-based methods, especially using windowed Fourier phases, inherit good properties in the case of hierarchical approaches, because they basically use a multi-resolution phase map. On the contrary, their computational costs are very heavy. Therefore, a fast hierarchical approach, using multi-resolution phase-based strategy and reducing the redundancy of phase calculations, is proposed in this pare. In addition, a structural matching algorithm on the phase domain is adopted to improve the matching quality. In experimental results, it is shown that the computation loads are considerably reduced about 8 times and stable outputs are obtained.