• 제목/요약/키워드: Multi-cloud monitoring

검색결과 34건 처리시간 0.027초

구름에 의한 지표 일사량의 증가 (The effects of clouds on enhancing surface solar irradiance)

  • 정연진;조희구;김준;김영준;김윤미
    • 대기
    • /
    • 제21권2호
    • /
    • pp.131-142
    • /
    • 2011
  • Spectral solar irradiances were observed using a visible and UV Multi-Filter Rotating Shadowband Radiometer on the rooftop of the Science Building at Yonsei University, Seoul ($37.57^{\circ}N$, $126.98^{\circ}E$, 86 m) during one year period in 2006. 1-min measurements of global(total) and diffuse solar irradiances over the solar zenith angle (SZA) ranges from $20^{\circ}$ to $70^{\circ}$ were used to examine the effects of clouds and total optical depth (TOD) on enhancing four solar irradiance components (broadband 395-955 nm, UV channel 304.5 nm, visible channel 495.2 nm, and infrared channel 869.2 nm) together with the sky camera images for the assessment of cloud conditions at the time of each measurement. The obtained clear-sky irradiance measurements were used for empirical model of clear-sky irradiance with the cosine of the solar zenith angle (SZA) as an independent variable. These developed models produce continuous estimates of global and diffuse solar irradiances for clear sky. Then, the clear-sky irradiances are used to estimate the effects of clouds and TOD on the enhancement of surface solar irradiance as a difference between the measured and the estimated clear-sky values. It was found that the enhancements occur at TODs less than 1.0 (i.e. transmissivity greater than 37%) when solar disk was not obscured or obscured by optically thin clouds. Although the TOD is less than 1.0, the probability of the occurrence for the enhancements shows 50~65% depending on four different solar radiation components with the low UV irradiance. The cumulus types such as stratoculmus and altoculumus were found to produce localized enhancement of broadband global solar irradiance of up to 36.0% at TOD of 0.43 under overcast skies (cloud cover 90%) when direct solar beam was unobstructed through the broken clouds. However, those same type clouds were found to attenuate up to 80% of the incoming global solar irradiance at TOD of about 7.0. The maximum global UV enhancement was only 3.8% which is much lower than those of other three solar components because of the light scattering efficiency of cloud drops. It was shown that the most of the enhancements occurred under cloud cover from 40 to 90%. The broadband global enhancement greater than 20% occurred for SZAs ranging from 28 to $62^{\circ}$. The broadband diffuse irradiance has been increased up to 467.8% (TOD 0.34) by clouds. In the case of channel 869.0 nm, the maximum diffuse enhancement was 609.5%. Thus, it is required to measure irradiance for various cloud conditions in order to obtain climatological values, to trace the differences among cloud types, and to eventually estimate the influence on solar irradiance by cloud characteristics.

Integrated Water Resources Management in the Era of nGreat Transition

  • Ashkan Noori;Seyed Hossein Mohajeri;Milad Niroumand Jadidi;Amir Samadi
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2023년도 학술발표회
    • /
    • pp.34-34
    • /
    • 2023
  • The Chah-Nimeh reservoirs, which are a sort of natural lakes located in the border of Iran and Afghanistan, are the main drinking and agricultural water resources of Sistan arid region. Considering the occurrence of intense seasonal wind, locally known as levar wind, this study aims to explore the possibility to provide a TSM (Total Suspended Matter) monitoring model of Chah-Nimeh reservoirs using multi-temporal satellite images and in-situ wind speed data. The results show that a strong correlation between TSM concentration and wind speed are present. The developed empirical model indicated high performance in retrieving spatiotemporal distribution of the TSM concentration with R2=0.98 and RMSE=0.92g/m3. Following this observation, we also consider a machine learning-based model to predicts the average TSM using only wind speed. We connect our in-situ wind speed data to the TSM data generated from the inversion of multi-temporal satellite imagery to train a neural network based mode l(Wind2TSM-Net). Examining Wind2TSM-Net model indicates this model can retrieve the TSM accurately utilizing only wind speed (R2=0.88 and RMSE=1.97g/m3). Moreover, this results of this study show tha the TSM concentration can be estimated using only in situ wind speed data independent of the satellite images. Specifically, such model can supply a temporally persistent means of monitoring TSM that is not limited by the temporal resolution of imagery or the cloud cover problem in the optical remote sensing.

  • PDF

Google Earth Engine과 Sentinel-2 위성자료를 이용한 러시아 노릴스크 지역의 기름 유출 모니터링 (Oil Spill Monitoring in Norilsk, Russia Using Google Earth Engine and Sentinel-2 Data)

  • 김민주;현창욱
    • 대한원격탐사학회지
    • /
    • 제39권3호
    • /
    • pp.311-323
    • /
    • 2023
  • 기름 유출 사고는 발생 시 환경과 관련된 다양한 문제들을 야기하므로 신속하게 유출유의 면적과 위치 변화를 파악하는 것이 중요하다. 광학 위성자료를 활용한 기름 유출 탐지의 경우 다양한 위성탑재 센서를 통해 유출유에 대한 정보 수집 후 이를 이용하여 광범위한 기름 유출 범위를 모니터링할 수 있다. 선행 연구에서는 파장별 기름의 반사도를 분석한 후 특정 파장대의 밴드를 이용한 oil spill index가 개발 및 적용되었다. 기름 유출 모니터링을 위해 유출 전후 여러 시기의 위성자료를 분석할 경우 다량의 데이터로 인해 많은 시간과 컴퓨팅 자원이 소비된다. 웹 브라우저를 통해 대량의 위성자료 분석이 가능한 Google Earth Engine을 활용할 경우 효율적으로 기름 유출 탐지가 가능하다. 본 연구에서는 Sentinel-2 MultiSpectral Instrument 위성자료와 클라우드 기반의 위성자료 분석 플랫폼인 Google Earth Engine을 이용하여 기존에 제안된 네 종류의 oil spill index의 다양한 피복 환경에서의 활용성 평가를 수행하였다. 지표 피복별 index 값의 비교를 통해 기름 유출 영역이 타 피복과 잘 구분되는지에 대한 분리도를 평가하고 기름 유출 면적을 산정하였다. 본 연구 결과를 통해 Google Earth Engine이 기름 유출 광역 모니터링에 효율적으로 활용 가능하다는 것을 확인하였고, 복잡한 지표 피복이 분포하는 다른 지역에 기름 유출 사고 발생 시 우수한 성능으로 평가된 oil spill index B ((B3+B4)/B2)와 C (R: B3/B2, G: (B3+B4)/B2, B: (B6+B7)/B5)의 적용은 효과적인 기름 유출 모니터링에 기여할 것으로 판단된다.

전력선통신(PLC) 방식을 이용한 스마트콘센트와 게이트웨이에 관한 연구 (A Study on the Smart Outlet and Gateway Using Power Line Communication)

  • 박성진;김유진;박인지;김진영;임창균
    • 한국전기전자재료학회논문지
    • /
    • 제33권4호
    • /
    • pp.331-335
    • /
    • 2020
  • In this study, through the accumulated technologies such as real-time monitoring of power consumption using power line communication (PLC) method, power control, and automatic blocking of standby power, to commercialize them, we developed the hardware design, algorithm, protocol and module along with data transmission using PLC. We conducted the study to develop advanced products. We also proposed cloud-based smart outlet products with a novel type of outlet. These products can measure the internal power consumption through the H/W modules and the modules that control the power of household appliances connected to the smart outlets and smart plugs. Subsequently, they transmit the measurements to the energy saving system server via a communication module. This system can control the terminal device connected to the Gateway (G/W) server through a mobile phone. This will allow the customer to check the power consumption of the building at any given time, to turn the terminal on/off, and to maximize the energy efficiency during the construction of new apartments or multi-family housing in an area.

Job-aware Network Scheduling for Hadoop Cluster

  • Liu, Wen;Wang, Zhigang;Shen, Yanming
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권1호
    • /
    • pp.237-252
    • /
    • 2017
  • In recent years, data centers have become the core infrastructure to deal with big data processing. For these big data applications, network transmission has become one of the most important factors affecting the performance. In order to improve network utilization and reduce job completion time, in this paper, by real-time monitoring from the application layer, we propose job-aware priority scheduling. Our approach takes the correlations of flows in the same job into account, and flows in the same job are assigned the same priority. Therefore, we expect that flows in the same job finish their transmissions at about the same time, avoiding lagging flows. To achieve load balancing, two approaches (Flow-based and Spray) using ECMP (Equal-Cost multi-path routing) are presented. We implemented our scheme using NS-2 simulator. In our evaluations, we emulate real network environment by setting background traffic, scheduling delay and link failures. The experimental results show that our approach can enhance the Hadoop job execution efficiency of the shuffle stage, significantly reduce the network transmission time of the highest priority job.

Innovative Geostationary Communication and Remote Sensing Mutli-purpose Satellite Program in Korea-COMS Program

  • 백명진;박재우
    • 한국위성정보통신학회논문지
    • /
    • 제2권2호
    • /
    • pp.29-35
    • /
    • 2007
  • 통신해양기상위성은 다목적 정지궤도위성으로서 Ka대역 통신탑재체, 기상센서 및 해양센서를 하나의 위성플랫폼에 탑재한 복합위성이다. 본 논문에서는 한국정부의 자금으로 개발되는 첫번째 혁신적인 정지궤도 통신해양기상위성 프로그램에 대해서 소개하고자 한다. 위성플랫폼은 아스트리움의 EUROSTAR 3000 통신위성을 기반으로 하고 있으며, 세 개의 다른 탑재체를 효과적으로 수용하기 위하여 화성탐사선 Express를 일부 활용하였다. 세개의 탑재체 중 통신탑재체는 스위칭 다중빔 기술을 검증하고 광대역 멀티미디어 통신서비스를 시험하는데 목적이 있다. 기상센서임무는 고해상도 멀티분광 센서로 지속적으로 한반도 기상데이타를 산출하는데 있으며, 세계 최초의 정지궤도 해양센서는 한반도의 어류자원정보 및 장단기 해양정보의 모니터링을 목적으로 하고 있다. 통신임무와 원격탐사임무를 동시에 수행해야 하므로 위성체의 요구사항은 매우 복잡하여 이를 만족시키기 위한 설계 및 조립/시험의 난이도는 매 우 높다고 할 수 있겠다.

  • PDF

농업관측을 위한 다중분광 무인기 반사율 변동성 분석 (Analysis of UAV-based Multispectral Reflectance Variability for Agriculture Monitoring)

  • 안호용;나상일;박찬원;홍석영;소규호;이경도
    • 대한원격탐사학회지
    • /
    • 제36권6_1호
    • /
    • pp.1379-1391
    • /
    • 2020
  • 농업에서의 무인기는 촬영 영역은 작지만, 위성이 가지지 못하는 초고해상도의 영상 수집이 가능하며, 작물의 생물계절에 맞는 영상을 적시에 획득 할 수 있어 들녘단위 농경지의 모니터링에 유용하게 사용될 수 있다. 하지만 무인기의 경우 위성과 달리 다양한 카메라와 촬영 환경에 따른 다중시기 영상을 활용하기 때문에 시계열 영상 활용을 위해서는 정규화 된 영상자료를 활용하는 것이 필수적으로 요구된다. 본 연구는 무인기 다중분광 영상의 농업 모니터링 시계열 활용을 위해 촬영 환경에 따른 무인기 반사율 및 식생지수의 변동성을 분석하였다. 촬영 고도, 촬영 방향, 촬영시간, 운량과 같은 환경요인에 따른 반사율 변동성은 8%에서 11%로 매우 크게 나타났으나, 식생지수의 변동성은 1% ~ 5%로 안정적인 것을 확인 할 수 있었다. 이러한 현상은 무인기 다중분광센서의 특성과 후처리 프로그램의 정규화 등 다양한 원인이 존재하는 것으로 판단된다. 따라서 무인기 영상의 시계열 활용을 위해서는 식생지수와 같은 밴드비율함수를 활용하는 것이 권장되며 촬영 시 가능한 동일한 촬영시간, 촬영 고도, 촬영 방향을 설정하여 시계열 영상의 변동성을 최소화하는 것이 권장된다.

지상원격측정 MAX-DOAS 시스템과 위성 OMI센서로 서울에서 산출된 이산화질소 층적분농도의 비교연구 (Comparison of Nitrogen Dioxide Retrieved by MAX-DOAS and OMI measurements in Seoul)

  • 이한림
    • 대한원격탐사학회지
    • /
    • 제29권2호
    • /
    • pp.235-241
    • /
    • 2013
  • 본 연구에서는 2007년과 2008년 봄 기간 중 동북아 지역의 주요 메가시티 중 하나인 서울에서 Multi-Axis Differential Optical Absorption Spectroscopy(MAX-DOAS) 관측을 처음으로 수행하고, 측정된 스펙트럼의 차등흡수분광 분석을 통하여 이산화질소의 수직층적분농도를 산출 하였다. MAX-DOAS로부터 산출된 값들과 Ozone Monitoring Instrument(OMI) 위성센서로부터 산출된 서울지역의 대류권 이산화질소 산출물과의 비교를 통하여 OMI로부터 산출된 이산화질소 수직층적분농도의 상대적 정확성 규명을 수행하였다. MAX-DOAS로부터 산출된 이산화질소는 $1.0{\times}10^{15}molec{\cdot}cm^{-2}$에서 $6.0{\times}10^{16}molec{\cdot}cm^{-2}$ 정도 분포로 보였으며, OMI의 대류권 수직층적분농도는 $1.0{\times}10^{15}molec{\cdot}cm^{-2}$에서 $7.0{\times}10^{16}molec{\cdot}cm^{-2}$ 정도 분포로 보였다. 관측전체기간인 6개월 동안 두 관측결과의 상관관계를 보여주는 상관계수(R)는 0.73으로 비교적 양호한 상관 관계를 보였다. 구름이 없는 기간 동안에는 상관계수가 0.85로 두 관측결과의 높은 상관관계는 확인 할 수 있었다. 두 센서의 산출알고리즘 모두 구름이 있을 경우 대기질량인자의 계산에 있어서 높은 불확실성으로 인해 이산화질소농도의 산출오차가 높은 것으로 판단된다.

다목적 실용위성 1호의 한반도 통과시각 결정을 위한 연구 (I): 태양 및 대기 변수 조사 (A STUDY FOR THE DETERMINATION OF KOMPSAT I CROSSING TIME OVER KOREA (I): EXAMINATION OF SOLAR AND ATMOSPHERIC VARIABLES)

  • 권태영;이성훈;오성남;이동한
    • Journal of Astronomy and Space Sciences
    • /
    • 제14권2호
    • /
    • pp.330-346
    • /
    • 1997
  • 다목적 실용위성 1호 (KOMPSAT I)는 지도 제작, 해양관측, 우주 과학실험 등에 활용할 태양도기 저궤도용 위성으로 1999년 8~9월에 발사될 예정이다. 본 위성에 탑재될 고해상도 전자광학 카메라(Electro-Optical Camera: EOC)의 주임무는 한반도 표준지도 제작을 위한 위성영상정보의 획득이다. EOC 센서는 가시광선 영역의 흑백 단일 채널(510~730mm)을 통해 수직 촬영 시 최소 15km 이상의 폭과 궤도 800km의 길이를 지상 해상도 6.6m로 촬영한다. 본 연구에서는 아리랑 1호의 한반도 통과 시각을 결정하기 위하여 한반도 지역에 있어 EOC 영상에 커다란 영향을 미치는 태양 변수와 구름과 시정의 일변를 조사하였다. 조사 결과는 다음과 같다. 1) 동지의 경우 대략 오전 10시 30분 이후 태양 천장 각 의 $70^{\circ}$보다 작고, 예상되는 EOC 스펙트럼 밴드의 flux 값은 맑은 날씨 육지에서 약 $2.4mW/cm^2$보다 크다. 2) 낮 동안의 구름의 분포 (맑은 하늘의 분포)는 오전 11시경에 최소값(최대값)을 보이며, 비록 안개에 의한 악 시정의 발생 빈도는 정오로 갈수록 감소하나 맑은 하늘의 분포에 미치는 영향은 미약하다. 이러한 결과로부터 EOC 관측을 위해서는 다목적 실용위성 1호의 한반도 통과 시각을 오전 10시 30분에서 11시 30분 사이에서 결정하는 것이 적합하다고 판단된다.

  • PDF

EPAR V2.0: AUTOMATED MONITORING AND VISUALIZATION OF POTENTIAL AREAS FOR BUILDING RETROFIT USING THERMAL CAMERAS AND COMPUTATIONAL FLUID DYNAMICS (CFD) MODELS

  • Youngjib Ham;Mani Golparvar-Fard
    • 국제학술발표논문집
    • /
    • The 5th International Conference on Construction Engineering and Project Management
    • /
    • pp.279-286
    • /
    • 2013
  • This paper introduces a new method for identification of building energy performance problems. The presented method is based on automated analysis and visualization of deviations between actual and expected energy performance of the building using EPAR (Energy Performance Augmented Reality) models. For generating EPAR models, during building inspections, energy auditors collect a large number of digital and thermal imagery using a consumer-level single thermal camera that has a built-in digital lens. Based on a pipeline of image-based 3D reconstruction algorithms built on GPU and multi-core CPU architecture, 3D geometrical and thermal point cloud models of the building under inspection are automatically generated and integrated. Then, the resulting actual 3D spatio-thermal model and the expected energy performance model simulated using computational fluid dynamics (CFD) analysis are superimposed within an augmented reality environment. Based on the resulting EPAR models which jointly visualize the actual and expected energy performance of the building under inspection, two new algorithms are introduced for quick and reliable identification of potential performance problems: 1) 3D thermal mesh modeling using k-d trees and nearest neighbor searching to automate calculation of temperature deviations; and 2) automated visualization of performance deviations using a metaphor based on traffic light colors. The proposed EPAR v2.0 modeling method is validated on several interior locations of a residential building and an instructional facility. Our empirical observations show that the automated energy performance analysis using EPAR models enables performance deviations to be rapidly and accurately identified. The visualization of performance deviations in 3D enables auditors to easily identify potential building performance problems. Rather than manually analyzing thermal imagery, auditors can focus on other important tasks such as evaluating possible remedial alternatives.

  • PDF