• Title/Summary/Keyword: Multi-Loop

Search Result 522, Processing Time 0.024 seconds

A Closed-loop-control System for Filling Balance in the Hot Runner Mold with Multi-Cavities (다수 캐비티를 갖는 핫러너 금형에서의 균형충전을 위한 자동제어시스템)

  • Jang, Min-Kyu;Jo, Il-Kyu;Lee, Ok-Seong;Jeong, Yeong-Deug
    • Design & Manufacturing
    • /
    • v.9 no.1
    • /
    • pp.23-26
    • /
    • 2015
  • For mass production of plastics, injection molds have multi-cavities. However, filling imbalance between cavity to cavity always has occurred in multi-cavities mold, and this has caused low quality of plastics part. In this study, the closed-loop-control system which can control temperature of hot manifold and nozzle in hot runner mold for filling balance has been suggested, and a series of experiment about difference of filling time and weight in cavity-to-cavity was conducted. As a result of using closed-loop-control system, a remarkable improvement in reducing filling imbalance was confirmed.

  • PDF

Performance analysis of atomic magnetometer and bandwidth-extended loop antenna in resonant phase-modulated magnetic field communication system

  • Hyun Joon Lee;Jung Hoon Oh;Jang-Yeol Kim;In-Kui Cho
    • ETRI Journal
    • /
    • v.46 no.4
    • /
    • pp.727-736
    • /
    • 2024
  • Telecommunications through an electrically conductive medium require the use of carrier bands with very-low and ultralow frequencies to establish radiofrequency links in harsh environments. Recent advances in atomic magnetometers operating at very-low frequencies have facilitated the reception of digitally modulated signals. We demonstrate the transmission and reception of quadrature phase-shift keying (QPSK) signals using a multi-resonant loop antenna and atomic magnetometer, respectively. We report the measured error vector magnitude according to the symbol rate for QPSK modulation and analyze the bandwidth of a receiver based on the atomic magnetometer. The multi-resonant loop antenna noticeably enhances the bandwidth by over 70% compared with a single-loop antenna. QPSK modulation for a carrier frequency of 20 kHz and symbol rate of 150 symbols per second verifies the feasibility of demodulation, and the measured error vector magnitude and signal-to-noise ratio are 7.29% and 30.9 dB, respectively.

Phase Controlled Thin Film Loop Antenna for Multi-media Devices (멀티미디어단말기용 박막형 위상제어루프 안테나)

  • Shin, Cheon-Woo
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.7
    • /
    • pp.971-978
    • /
    • 2009
  • The paper is a phase controlled loop antenna for multi-media devices. We developed a phase control loop pattern arrangement methods for loop antenna in mobile devices like as a cell phone and PCS, WCDMA. In the loop antenna pattern, arrange close adhesive the loop antenna pattern $180^\circ$ cycle in wave length, the radiated electro-magnetic wave from close adhesive loop pattern become to coherent wave than the phase controlled loop antenna has high efficiency and high radiation gain. To acquire a wide band width on phase controlled loop antenna, we arrange a multiple phase controlled loop pattern that has a different length each other. Different length for each other loop pattern cause a different frequency that we can acquire a wide band width for loop antenna from close adhesive phase control. In experiment, we designed a CDMA850 mobile multi-media antenna in 20mm$\times$20mm area thickness 0.4mm, the radiation efficiency is over 60% and radiation gain is over 0dBi.

  • PDF

Analysis of severe accident progression and Cs behavior for SBO event during mid-loop operation of OPR1000 using MELCOR

  • Park, Yerim;Shin, Hoyoung;Kim, Seungwoo;Jin, Youngho;Kim, Dong Ha;Jae, Moosung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.2859-2865
    • /
    • 2021
  • One of the important issues raised from the Fukushima-Daiichi accident is the safety of multi-unit sites when simultaneous accidents occur at the site and recently a multi-unit PSA methodology is being developed worldwide. Since all operation modes of the plant should be considered in the multi-unit PSA, the accident analysis needs to be performed for shutdown operation modes, too. In this study, a station blackout during the mid-loop operation is selected as a reference scenario. The overall accident progression for the mid-loop operation is slower than that for the full-power operation because the residual heat per mass of coolant is about 6 times lower than that in the mid-loop scenario. Though the fractions of Cs released from the core to the RCS in both operation modes are almost the same, the amount of Cs delivered to the containment atmosphere is quite different due to the chemisorption in the RCS. While 45.5% of the initial inventory is chemisorbed on the RCS surfaces during the full-power operation, only 2.2% during the mid-loop operation. The containment remains intact during the mid-loop operation, though 83.9% of Cs is delivered to the containment.

A Comparison of Flow Condensation HTCs of R22 Alternatives in the Multi-Channel Tube (알루미늄 다채널 평판관내 R22의 흐름응축 열전달 성능 비교)

  • Seo, Young-Ho;Lim, Dae-Taeg;Park, Ki-Jung;Jung, Dong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1270-1275
    • /
    • 2004
  • Flow condensation heat transfer coefficients(HTCs) of R22 and R134a were measured on horizontal aluminum multi-channel tube. The experimental apparatus was composed of three main parts ; a refrigerant loop, a water loop and a water-ethylene glycol loop. The test section in the refrigerant loop was made of aluminum multi-channel tube of 1.4 mm hydraulic diameter and 0.53 m length. The refrigerant was cooled by passing cold water through an annulus surrounding the test section. The data scan vapor qualities $(0.1{\sim}0.9)$, mass flux ($200{\sim}400$ $kg/m^{2}s$) and heat flux ($7.3{\sim}7.7$ $kW/m^{2}$) at $40{\times}0.2^{\circ}C$ saturation temperature in small hydraulic diameter tube. It was found that some well-known previous correlations were not suitable for multichannel tube. So, It must develop new correlations for multi-channel tubes.

  • PDF

Multi-Mode Wireless Power Transfer System with Dual Loop Structure (이중루프 구조를 갖는 다중모드 무선전력전송 시스템)

  • Han, Minseok
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.6
    • /
    • pp.578-583
    • /
    • 2016
  • In this paper, we propose a multi-mode wireless power transfer (WPT) system with a dual loop structure. The proposed multi-mode WPT system consist of outer loop module which can operate at two different frequency bands including 6.78 MHz magnetic resonance WPT mode and 13.56 MHz near field communication (NFC) mode and inner loop module connected with outer loop which can operate at two different frequency bands including WPC mode and PMA mode based on inductive coupling standards. In order to be able to embed this system into smartphone battery back cover, the electrical designs are optimized and then the size was fixed $45{\times}90{\times}0.35mm3$ (including ferrite sheet) which is the same commercial smartphone. The proposed multi-mode WPT module can cover WPC and PMA mode based on inductive coupling. Moreover, it has more than 20 dB return loss characteristics at two different frequency bands including 6.78 MHz and 13.56 MHz, and shows more than 70 % transfer efficiency between resonant coils at 6.78 MHz in magnetic resonant charging environment.

PWM DC-AC Converter Regulation using a Multi-Loop Single Input Fuzzy PI Controller

  • Ayob, Shahrin Md.;Azli, Naziha Ahmad;Salam, Zainal
    • Journal of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.124-131
    • /
    • 2009
  • This paper presents a PWM dc-ac converter regulation using a Single Input Fuzzy PI Controller (SIFPIC). The SIFPIC is derived from the signed distanced method, which is a simplification of a conventional fuzzy controller. The simplification results in a one-dimensional rule table, that allows its control surface to be approximated by a piecewise linear relationship. The controller multi-loop structure is comprised of an outer voltage and an inner current feedback loop. To verify the performance of the SIFPIC, a low power PWM dc-ac converter prototype is constructed and the proposed control algorithm is implemented. The experimental results show that the SIFPIC performance is comparable to a conventional Fuzzy PI controller, but with a much reduced computation time.

Optimization of compression ratio in closed-loop CO2 liquefaction process

  • Park, Taekyoon;Kwak, Hyungyeol;Kim, Yeonsoo;Lee, Jong Min
    • Korean Journal of Chemical Engineering
    • /
    • v.35 no.11
    • /
    • pp.2150-2156
    • /
    • 2018
  • We suggest a systematic method for obtaining the optimal compression ratio in the multi-stage closed-loop compression process of carbon dioxide. Instead of adopting the compression ratio of 3 to 4 by convention, we propose a novel approach based on mathematical analysis and simulation. The mathematical analysis prescribes that the geometric mean is a better initial value than the existing empirical value in identifying the optimal compression ratio. In addition, the optimization problem considers the initial installation cost as well as the energy required for the operation. We find that it is best to use the fifth stage in the general closed-loop type carbon dioxide multi-stage compression process.

Performance Comparison of Different Solar Array Simulator Control by Ellipse Approximation (태양광패널 모사장치의 제어방식에 따른 소신호 특성 비교 분석)

  • Wellawatta, Thusitha;Seo, Young-Tae;Choi, Sung-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.1
    • /
    • pp.16-24
    • /
    • 2021
  • Solar array simulator (SAS) is essential equipment in testing and evaluating the power processing performance of a power conditioning system. However, the nonlinearity in the current(I)-voltage(V) characteristic makes the control loop design of SAS a challenging task. Conventionally, only the inner loop is usually considered in the control design approach. However, this study proves that the reference generation loop also interacts with the inner loop and plays a key role in the overall performance of the SAS. In this paper, the performance of voltage-mode control and impedance control, which are two of the most popular architectures for the SAS system, are reviewed and compared by multi-loop analysis.

The Optimal Compensator for AT Forward Multi Resonant Converter

  • Oh Yong-Seung;Kim Hee-Jun;Kim Chang-Sun
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.242-246
    • /
    • 2001
  • The alternated forward multi resonant converter (AT forward MRC) is studied on the transient response and the measured loop gain for stability. The compensator is composed of the error amplifier with 3 poles and 2 zeros. This is optimized through the experiment with HP4194A network analyzer. We are initiated by the thinking of how to make the stabilization from the experimental results of loop gain curves. The loop gain, low frequency gain and gain margin are more improved through the experimental considerations. Also, the transient response is more enhanced effectively.

  • PDF