• 제목/요약/키워드: Multi-Function Display

검색결과 91건 처리시간 0.026초

경혈 교육을 위한 3D 및 증강현실 기술을 활용한 한의학 통합교육 테이블 개발 (A Development of an Acupoints Education Table using 3D Technology and Augmented Reality)

  • 양승정;류창주;김상철;김재석
    • Korean Journal of Acupuncture
    • /
    • 제38권4호
    • /
    • pp.267-274
    • /
    • 2021
  • Objectives : Acupoints education is important in that it can determine the clinical competency of Korean Medicine Doctors (KMDs). Accordingly, we aimed to develop a practical simulator for acupoints education, acupoints training, acupoints practice, and acupoints evaluation. Methods : Korean Medicine (KM) SMART Table can be divided into hardware, server and components, and is organically linked. We develop KM SMART Table that combines the hardware of a human-sized table with a UHD display capable of multi-touch in two cases and software that can teach acupoints. We make Augmented Reality (AR) contents linked with KM SMART Table contents and develop applications that can use contents using mobile devices. By developing an AR image tracking module to react with KM SMART Table, it enables acupoint learning according to the mobile device platform and human anatomy. Results : The current system is a prototype where some 3D technology has been implemented, but the AR function will be produced later. New learning using 3D and AR will be required during acupoints education and acupoints practice. It will be used a lot in OSCE (Objective Structured Clinical Examination) practices for strengthening the competency of KMDs, and it will be of great help not only in KM education as a unique simulator of KM, but also in the practice of acupuncture and chuna for musculoskeletal diseases. Conclusions : The KM SMART Table is a technology that combines 3D and AR to learn acupoints, and to conduct acupoints OSCE practice, and we suggest that it can be usefully used for educational evaluation.

다종 장사정포 공격에 대한 강화학습 기반의 동적 무기할당 (Reinforcement Learning-based Dynamic Weapon Assignment to Multi-Caliber Long-Range Artillery Attacks)

  • 김현호;김정훈;공주회;경지훈
    • 산업경영시스템학회지
    • /
    • 제45권4호
    • /
    • pp.42-52
    • /
    • 2022
  • North Korea continues to upgrade and display its long-range rocket launchers to emphasize its military strength. Recently Republic of Korea kicked off the development of anti-artillery interception system similar to Israel's "Iron Dome", designed to protect against North Korea's arsenal of long-range rockets. The system may not work smoothly without the function assigning interceptors to incoming various-caliber artillery rockets. We view the assignment task as a dynamic weapon target assignment (DWTA) problem. DWTA is a multistage decision process in which decision in a stage affects decision processes and its results in the subsequent stages. We represent the DWTA problem as a Markov decision process (MDP). Distance from Seoul to North Korea's multiple rocket launchers positioned near the border, limits the processing time of the model solver within only a few second. It is impossible to compute the exact optimal solution within the allowed time interval due to the curse of dimensionality inherently in MDP model of practical DWTA problem. We apply two reinforcement-based algorithms to get the approximate solution of the MDP model within the time limit. To check the quality of the approximate solution, we adopt Shoot-Shoot-Look(SSL) policy as a baseline. Simulation results showed that both algorithms provide better solution than the solution from the baseline strategy.

액정 디스플레이 배향막을 위한 이온빔 표면조사에 관한 연구 (Ion beam irradiation for surface modification of alignment layers in liquid crystal displays)

  • 오병윤;김병용;이강민;김영환;한정민;이상극;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 및 기술 세미나 논문집 디스플레이 광소자
    • /
    • pp.41-41
    • /
    • 2008
  • In general, polyimides (PIs) are used in alignment layers in liquid crystal displays (LCDs). The rubbing alignment technique has been widely used to align the LC molecules on the PI layer. Although this method is suitable for mass production of LCDs because of its simple process and high productivity, it has certain limitations. A rubbed PI surface includes debris left by the cloth, and the generation of electrostatic charges during the rubbing induces local defects, streaks, and a grating-like wavy surface due to nonuniform microgrooves that degrade the display resolution of computer displays and digital television. Additional washing and drying to remove the debris, and overwriting for multi-domain formation to improve the electro-optical characteristics such as the wide viewing angle, reduce the cost-effectiveness of the process. Therefore, an alternative to non-rubbing techniques without changing the LC alignment layer (i.e, PI) is proposed. The surface of LC alignment layers as a function of the ion beam (IE) energy was modified. Various pretilt angles were created on the IB-irradiated PI surfaces. After IB irradiation, the Ar ions did not change the morphology of the PI surface, indicating that the pretilt angle was not due to microgrooves. To verify the compositional behavior for the LC alignment, the chemical bonding states of the ill-irradiated PI surfaces were analyzed in detail by XPS. The chemical structure analysis showed that ability of LCs to align was due to the preferential orientation of the carbon network, which was caused by the breaking of C=O double bonds in the imide ring, parallel to the incident 18 direction. The potential of non-rubbing technology for fabricating display devices was further conformed by achieving the superior electro-optical characteristics, compared to rubbed PI.

  • PDF

시게루 반 전시공간의 생태적 특성과 변화 연구 (A Study on the Ecological Characteristics and Changes of the Shigeru Ban Exhibition Space)

  • 티엔휘;윤지영
    • 한국콘텐츠학회논문지
    • /
    • 제22권2호
    • /
    • pp.147-161
    • /
    • 2022
  • 본 연구는 2000년 이후 시게루 반이 설계한 대표적인 임시전시관 3곳과 상설전시관 3곳을 대상으로 반의 전시공간의 생태적 특성과 디자인 특성에 대한 변화를 고찰하였다. 생태건축에 관한 개념 및 특성, 전시공간의 디자인 특성 등에 대한 문헌고찰을 통해 전시공간의 디자인 특성과 생태건축의 디자인요소에 대한 분석틀을 도출하였다. 연구 결과 건축규모, 공간구성, 기능, 재료 및 기술 측면에서 임시전시관과 상설전시관 사이에 큰 변화가 있다. 시게루 반의 임시전시관은 재활용 가능한 재료로 종이튜브, 컨테이너 등을 현장에서 전시 위주의 단층 공간으로 조립해 조립방법이 단순하고 공기가 짧아 전시회가 끝난 후 전시관이 철거되어 그 재료가 다음 전시장으로 옮겨지거나 재활용됐다. 한편 상설전시관은 철근콘크리트를 주체로 하고 목재와 유리재료를 다량으로 사용해 전시공간과 휴게공간을 분리시킨 다층 복합문화공간을 조성했다. 또한 시게루 반의 전시관을 영구건축으로서 친환경적인 재료와 혁신적인 구조기술, 기후설계 개념을 적용하는 등 지속가능한 건축을 실현하고 있다. 생태적 특성 측면에서 임시전시관은 건축자재를 모두 재활용할 수 있어 철거 후 산업폐기물이 발생하지 않았다. 상설전시관은 지붕, 벽면 등에 친환경 목재를 사용해 교체와 보수가 용이하며 두 가지 유형의 전시관은 모두 자연채광과 환기를 통해 자원과 에너지를 절약을 등 생태적 건축을 보다 지속가능한 방향으로 변화시켜 가고 있다.

ZnS:Mn/ZnS:Tb 박막 전계발광소자의 문턱전압 변화 (Threshold Voltage Variation of ZnS:Mn/ZnS:Tb Thin- film Electroluminescent(TFEL) Devices)

  • 이순석;윤선진;임성규
    • 전자공학회논문지D
    • /
    • 제35D권6호
    • /
    • pp.21-27
    • /
    • 1998
  • E-beam 장비로 ZnS:Mn/Zns:Tb 2층 구조의 TFEL 소자를 제작하여 전기, 광학적 특성을 조사하였다. ITO 투명전극과 ATO 절연체가 증착된 유리기판(corning 7059 glass) 위에 E-beam 장비를 이용하여 ZnS:Mn, ZnS:Tb 형광체를 각각 3000 A로 증착하여 총 두께 6000 Å 갖도록 제작하였다. ZnS:Mn/ZnS:Tb TFEL 소자의 스펙트럼은 Mn/sup 2+/ 이온과 Tb/sup 3+/ 이온의 고유한 발광 스펙트럼을 모두 포함하여 540㎚에서 640㎚에 이르는 매우 넓은 범위의 발광 스펙트럼을 나타내었다. 휘도는 인가전압의 크기가 112V에서부터 급격히 증가하여 155 V에서 포화 휘도 1025 Cd/㎡를 나타내었고 최대 전압 185 V에서의 휘도는 2080 Cd/㎡이었다. Capacitance-voltage(C-V) 및 transferred charge-phosphor voltage(Q/sub t/-V/sub p/) 특성으로부터 형광층 capacitance (C/sub p/)와 절연층 capacitance (C/sub i/)가 각각 13.5 nF/㎠, 60 nF/㎠됨을 알 수 있었고, 인가전압의 최대치를 155 V에서 185 V로 증가시킬수록 TFEL 소자의 문턱전압(V/sub thl/)이 126 V에서 93 V로 감소함을 알 수 있었다. 이것은 인가전압을 증가시킬수록 polarization charge가 증가되고 polarization charge에 의해 형성된 형광체 내부전압이 증가되었기에 문턱전압이 감소한 것이다. 또한 처음으로 문턱전압에 관한 수식을 제안하였으며 문턱전압의 이론치와 실험치가 일치하는 것을 확인하였다.

  • PDF

변형된 영상 생성 모델을 이용한 칼라 영상 보정 (Color Image Rendering using A Modified Image Formation Model)

  • 최호형;윤병주
    • 대한전자공학회논문지SP
    • /
    • 제48권1호
    • /
    • pp.71-79
    • /
    • 2011
  • 이미징 파이프라인(imaging pipeline)의 목적은 디스플레이 되는 영상을 원영상과 비슷하게 변환하는 것이다. 이를 위해 감마 조정 혹은 히스토그램기반 방법이 영상대비와 세부 영역을 개선하기 위해 제안되었다. 그러나 이러한 방법들은 조도성분과 색도성분이 위치에 따라 변화하므로 영상 개선에 한계가 있다. 따라서 MSR (Multi-Scale Retinex) 기법이 제안되었으며, 이는 영상에 따른 가우시안 필터의 크기에 의존하며, 독립적인 로그 신호를 기반으로 한다. 그러므로 영상 보정 후 후광효과(Halo), 색상변화(Color change or graying-out), 특정 색상의 두드러짐 등의 영상 왜곡(image distortion)이 발생한다. 따라서 본 논문에서는 영상을 전역조명성분, 국부조명성분, 반사성분으로 나누는 새로운 색상 보정 방법을 제안한다. 제안한 방법에서 전역조명성분은 가우시안 필터를 작용하여 획득하며, 국부 조명성분은 JND(Just-noticeable difference)기반 적응적 필터를 적용하여 획득한다. 반사성분은 원 영상에 획득된 전역조명성분과 국부조명성분으로 나누어 줌으로써 획득된다. 개선된 영상은 멱함수(power function)를 수행한 후 이들의 곱으로 획득되며, sRGB로 표현된다. 실험 결과에서 제안한 방법이 기존의 방법에 비해 우수한 성능을 보인다.

유니티와 언리얼 엔진 4 에서의 가상현실 개발환경에 관한 비교연구 (A Study on the Comparison of the Virtual Reality Development Environment in Unity and Unreal Engine 4)

  • 조윤식;김진모
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제28권5호
    • /
    • pp.1-11
    • /
    • 2022
  • 게임엔전은 실감형 콘텐츠를 제작하는 데 있어서 최소한의 시각적 품질 보증과 함께 멀티 플랫폼 등의 지원으로 개발시간 단축 등 효율적인 콘텐츠제작이 가능하다는 이점이 있다. 최근 게임엔진은 가상현실 HMD(Head Mounted Display)를 활용하는 실감형 콘텐츠를 쉽고 빠르며 효과적으로 제작할 수 있는 다양한 기능들을 제공하고 있다. 따라서, 본 연구는 게임을 비롯하여 콘텐츠제작 산업 분야에서 많이 활용되는 유니티와 언리얼 게임엔진을 중심으로 오큘러스 퀘스트 2 HMD를 활용한 가상현실 콘텐츠제작에서의 개발환경에 관한 비교연구를 수행한다. 먼저 각 엔진이 제공하는 최소한의 기능과 설정이 포함된 가상현실 템플릿 프로젝트를 기반으로 오큘러스 퀘스트 2 HMD와 전용 컨트롤러를 활요하여 개발환경을 구축하는 기본 설정 과정을 비교한다. 다음으로 가상환경에서 상호작용할 수 있는 간단한 체험환경을 제시하고 전용 컨트롤러를 활용하기 위한 개발환경과 오큘러스 퀘스트 2에서 제공하는 손 추적기능을 통해 실제 손을 직접 활용하는 개발환경 구축과정을 엔진별로 비교한다. 이러한 과정을 통해 가상현실 개발환경을 구축하는 기본적인 처리 과정을 이해함과 동시에 엔진이 가지는 특징과 차이를 확인하여 다양한 실감형 콘텐츠제작에 응용할 수 있는 연구로 활용하고자 한다.

콘텐츠를 통해 전통을 잇는 방식 - 단원미술관 전시사례를 중심으로 (The Way of Connecting to Tradition through Content)

  • 김상미
    • 트랜스-
    • /
    • 제9권
    • /
    • pp.17-36
    • /
    • 2020
  • 본 논문은 안산문화재단에서 운영하는 단원미술관의 전시 사례를 중심으로 콘텐츠 제작과 활용 그리고 확장 가능성에 대해 논의하는 데 그 목적을 가진다. 1991년 당시 문화체육관광부는 조선 후기 화원이자 풍속화의 대가로 알려진 단원 김홍도(檀園 金弘道, 1745~ ? )의 고향으로 추정되는 안산을 '단원의 도시'로 명명했다. 이에 안산은 단원 김홍도를 지역 고유의 자원으로 활용하고자 다각적인 노력을 기울이고 있다. 관광자원이자 문화콘텐츠로 단원 김홍도를 활용하여 단원조각공원 조성과 단원미술관 운영, 단원 김홍도 축제 기획 등 대내외적인 활동을 통해 단원 김홍도를 안산의 대표 브랜드화하고자 했다. 단원미술관은 단원 김홍도의 미술관이라고 지칭하기에 턱없이 부족한 수의 작품을 소장하고 있다. 2009년 <사슴과 동자>를 첫 매입하고 2016년 <화조도>를 매입한 이후 올해까지 단원 김홍도의 작품을 총 6점 소장하게 됐다.1 단원 김홍도의 작품을 수집하는데 현실적으로 많은 어려움이 따르기 때문이다. 이에 2015년 10월 개관한 단원콘텐츠관의 역할과 방향은 단원 김홍도의 진본을 소장하지 않아도 미술관의 역할과 기능이 가능하도록 하는 것이었다. 단원콘텐츠관을 단원 김홍도와 관련된 다양한 시각예술자료를 체계적으로 수집과 보존, 전시가 가능하도록 운영하고 디지털 자료 중심으로 고급 정보를 생산하여 이를 제공할 수 있도록 하는 비전을 설정했다. 다시 말해 도서관과 아카이브, 미술관(Library + Archive + Museum)의 기능이 결합된 One-Source Multi-Use의 복합문화 정보기관으로 단원콘텐츠관을 찾는 관람객의 욕구를 충족시킬 수 있도록 구축하고자 했다. 이는 소장품의 문제와 고서화(古書畫)가 가지는 전시의 한계를 극복하고 미술관의 역할과 기능을 충족시키는 등 동시대의 흐름을 반영하고 있어 여러 방면에서 시사하는 바가 크다. 단원 김홍도의 작품을 관람하고자 단원콘텐츠관을 찾는 관람객들에게 터치스크린과 딥 줌(Deep Zoom)의 기술을 이용하여 단원 김홍도의 디지털 아카이브를 실감형 서비스로 제공하고, 단원 김홍도의 원작을 그대로 해석하여 미디어 콘텐츠로 제작한 콘텐츠 전시를 통해 조선 시대 천재 화가 단원 김홍도의 작품세계를 쉽고 재미있게 접할 수 있도록 사업을 확장하고 있다.

  • PDF

무선전용 다중 언어의 번역을 지원하는 변환기의 구현 (Development of Convertor supporting Multi-languages for Mobile Network)

  • 최지원;김기천
    • 정보처리학회논문지C
    • /
    • 제9C권2호
    • /
    • pp.293-296
    • /
    • 2002
  • 유선 환경에서 시작한 인터넷에 현재 존재하고 있는 웹 컨텐츠들을 모바일 환경에서 이용할 수 있게 하기 위하여 UP. Link 에서는 자동으로 HTML을 HDML로 번역해주는 기능을 가지고 있다. UP 브라우저에서 HTML 페이지를 억세스할 때 UP.Link 내의 에이전트는 번역기에게 HTML과 HDML 간의 번역을 처리하게끔 한다. I-Mode는 일본의 NTT-Docomo에서 개발 되었으며 이미 여러 가지 서비스를 통해 엄청난 컨텐츠를 보유하고 있다. Stinger 프로젝트에 의해 개발된 ME(Micro Explorer) 또한 많은 부가기능를 가지고 있다. 본 논문에서는 WAP에서 C-HTML과 mHTML의 컨텐츠를 수용할 수 있는 변환기를 설계하고 구현하였다. I-Mode의 C-HTML과 MS사의 ME는 HTML의 간이형으로 컨텐츠 제공 업자들이 다른 언어를 익힐 필요가 없으므로 WAP에 비해 컨텐츠 개발에 유리하다. C-HTML과 WML은 모두 모바일 환경에서 쓰이기 때문에 한 페이지 내에 제한되어 있는 용량 또한 비슷하다. 그러므로 C-HTML을 WML로, mHTML을 WML로 바꾸는 변환기를 개발하기 위해서 먼저 각 언어와 관련된 스펙을 분석하고 각각의 서로 대응되는 element를 찾아 표를 작성하고 난 후에 변환을 위한 알고리즘을 적용하여 변환기를 구현한다. 만약 대응되는 element가 없을 경우에는 WML에서 지원하는 여러 가지의 태그들을 조합하여 최대한 같은 형식으로 디스플레이 해줄 수 있는 방안을 제시한다. 편집기에서는 변환된 WML 소스를 컨텐츠 저작자가 클립 기능을 이용하여 다른 내용을 추가하거나 내용을 바꿀 수 있도록 지원한다. 구현 결과 약 90% 이상의 변환이 가능하다.장 높았고 비만군이 9.840점(표준편차 4.638)로 가장 낮았으며, 남자에서는 과체중군이 14.780점(표준편차 4.601), 여자에서는 저체중군이 12.284점(표준편차 4.604)으로 체형존중감이 가장 높았고, 남(평균 10.166점, 표준편차 4.246), 여(평균 8.772점, 표준편차 5.723) 모두 비만군에서 체형존중감이 가장 낮았다. 4. 비만도와 체형만족도 및 체형존중감과의 상관관계는 비만도와 체형만족도(r= -.2081, p= .000), 비만도와 체형존중감(r= -.2250, p= .000)은 유의한 역상관관계를 나타내어 비만도가 높을수록 체형만족도와 체형존중감이 낮았다. 5. 일반적 특성에 따른 비만상태는 전체에서는 성별($chi^2$=88.136, p=.000), 체형에 대한 인식($chi^2$=242.371, p= .000)에서, 남자에서는 부의 체형($chi^2$=15.11, p= .019), 체형에 대한 인식($chi^2$=138.95, p= .000)에서, 여자에서는 모의 학력($chi^2$=19.46, p= .022), 체형에 대한 인식($chi^2$=143.35, p= .000)에서 유의한 차이가 있었다. 전체에서 성별은 남자에서 비만은 21.4%, 여자에서 비만은 6.6%로 남자가 비만인 경우가 더 많았고, 체형에 대한 인식은 자신의 체형이 말랐다고 인식하는 경우 비만은 0.7%, 보통이라고 인식하는 경우 비만은 9.3%, 비만하다고 인식하는 경우 비만은 64.6%로 나타났다. 남자에서 부의 체형이 마른 경우 실제 비만인 학생은 21.20%, 보통인 경우

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF