• Title/Summary/Keyword: Multi-Detector CT

Search Result 79, Processing Time 0.025 seconds

Influence of slice thickness of computed tomography and type of rapid protyping on the accuracy of 3-dimensional medical model (CT절편두께와 RP방식이 3차원 의학모델 정확도에 미치는 영향에 대한 연구)

  • Um Ki-Doo;Lee Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.34 no.1
    • /
    • pp.13-18
    • /
    • 2004
  • Purpose : This study was to evaluate the influence of slice thickness of computed tomography (CT) and rapid protyping (RP) type on the accuracy of 3-dimensional medical model. Materials and Methods: Transaxial CT data of human dry skull were taken from multi-detector spiral CT. Slice thickness were 1, 2, 3 and 4 mm respectively. Three-dimensional image model reconstruction using 3-D visualization medical software (V-works /sup TM/ 3.0) and RP model fabrications were followed. 2-RP models were 3D printing (Z402, Z Corp., Burlington, USA) and Stereolithographic Apparatus model. Linear measurements of anatomical landmarks on dry skull, 3-D image model, and 2-RP models were done and compared according to slice thickness and RP model type. Results: There were relative error percentage in absolute value of 0.97, 1.98,3.83 between linear measurements of dry skull and image models of 1, 2, 3 mm slice thickness respectively. There was relative error percentage in absolute value of 0.79 between linear measurements of dry skull and SLA model. There was relative error difference in absolute value of 2.52 between linear measurements of dry skull and 3D printing model. Conclusion: These results indicated that 3-dimensional image model of thin slice thickness and stereolithographic RP model showed relative high accuracy.

  • PDF

Computed tomographic anatomy of hepatic artery in normal beagle dogs

  • Kim, Soochan;Jeong, Seongmok;Lee, Heechun;Lee, Youngwon;Choi, Hojung
    • Korean Journal of Veterinary Research
    • /
    • v.59 no.2
    • /
    • pp.55-58
    • /
    • 2019
  • This study was performed to examine the visualization and anatomical variants of the hepatic artery with dual-phase computed tomography (CT) angiography and three-dimensional volume rendering imaging analysis in clinically normal dogs. Seven healthy beagle dogs were enrolled and underwent dual CT angiography. Arterial phase images could be obtained with multi-detector CT angiography using the fixed-scan method in these dogs. Contrast enhancement of the hepatic parenchyma was quite minimal because of the unique blood supply system of the liver. In most dogs, the main hepatic arterial branches were the right lateral branch, left branch, and right medial branch. Although hepatic arterial variation appears to be common in dogs, only one dog in this study had the caudate lobar branch as the first branch of the hepatic artery. Further study on a larger number of dogs with CT images will be needed to identify and classify the pattern of hepatic arterial variations.

Evaluation of Total Lung Volume and Density using Multi-Detector Computed Tomography in Normal Dogs (정상견에서 다중채널 컴퓨터단층촬영술을 통한 폐용적과 밀도의 평가)

  • Choi, Ho-Jung;Lee, Ki-Ja;Choi, Soo-Young;Lee, Jung-Woo;Han, Woo-Sok;Lee, In;Kwon, Young-Hang;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.28 no.5
    • /
    • pp.510-515
    • /
    • 2011
  • This study was performed to quantitatively assess the normal lung volume and density according to the position by multi-detector computed tomography (MDCT) in dogs. Helical CT of the thorax was performed on 4 different positions with dorsal, left lateral, right lateral and ventral recumbency in 6 Pekingese and 6 Maltese dogs. During CT scanning, dogs were kept hyperventilated. Through the 3-dimensional reconstruction of CT images, the lung parameters were measured as the volume and density of the left, right including accessory lobe, and total lung. 3D images represented the different lung shape between Pekingese and Maltese dogs. Their difference of total lung volume and total lung density was not significant on the each position in both breeds. Right lung volume was significantly higher than left. The difference of left and right volume was $66.91{\pm}25.1$ ml. Linear relationship was shown between body weight and lung volume of ventral recumbency position. The dependent lung had higher density and lower volume than nondependent lung in both breed dogs. The volume of nondependent lung was not changed compared with the volume on ventral or dorsal recumbency. The total lung volume measured with MDCT is correlated with the lung density, and the lung density is useful to predict the normal total lung volume.

Segmentation of Liver on MDCT Image (MDCT 영상에서 간의 추출)

  • Seo Jeongjoo;Ryu Gangmin;Fei Yang;Park Jongwon
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07b
    • /
    • pp.802-804
    • /
    • 2005
  • 제안된 연구에서는 기존의 일반 CT(Computerized tomography) 영상이 아닌 MDCT(Multi Detector CT) 영상을 이용하여 장기 추출에 관한 연구를 진행하였다. 조영제를 이용한 복부 MDCT 영상으로부터 모폴로지(morphology) 기법을 통해 간에 근접한 노이즈를 제거하고, 기존의 Otsu threshold를 개선하여 간의 명암값 분포를 구분할 수 있는 임계치를 구하였다. 찾아진 임계치를 이용하여 영상을 이진화하고, 최종적으로 위치정보를 이용하여 간에 해당하는 부분들을 추출하였다. 이러한 방식은 명암값과 위치정보를 이용하여 간을 추출한 후 다시 노이즈 문제를 해결하는 기존의 알고리즘과 비교했을 때, 처리 방식이 단순해지고 속도가 향상되었다. 추출된 간은 간 이식술이나 절제술에 필요한 간 내부의 혈관 인식과 간의 부분체적 계산 연구에 중요한 정보로 사용될 수 있을 것이다.

  • PDF

Pictorial Review of Diffuse Central Airway Diseases: Focus on CT Findings

  • Ahn, Hye-Shin;Hwang, Jung-Hwa;Chang, Yun-Woo;Kim, Hyun-Joo;Kwon, Kui-Hyang;Choi, Deuk-Lin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.70 no.1
    • /
    • pp.10-20
    • /
    • 2011
  • Various diseases can diffusely involve central airways, including the trachea and main stem bronchi. Central airway abnormalities are frequently not apparent or are overlooked on chest radiographs, even though the patient may have significant symptoms. Recent advances in spiral and multi-detector computed tomography (CT) with multi-planar reconstruction and three-dimensional demonstration, including virtual bronchoscopy, allow for excellent display of central airway anatomy and abnormalities with visualization of accurate locations of lesions. Early detection and proper diagnosis of airway diseases based on various radiographic findings will help determine appropriate treatment, including surgical planning and evaluation of treatment response. Herein we describe and illustrate the imaging findings of a wide spectra of diffuse central airway diseases.

Research on the Reduction of Exposure Dose of a Patient Having a PET/CT Exam (PET/CT 검사 환자의 피폭선량 경감을 위한 연구)

  • Kim, Bong-Su;Pyo, Sung-Jai;Cho, Yong-Gyi;Shin, Chai-Ho;Cho, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.10-16
    • /
    • 2009
  • Purpose: As the number of patients has increased since the installation of a PET/CT, we are now examining about 2500-3000 annually. We have realized that if we properly adjust a pitch under the same condition of a CT during a PET/CT exam, radiation quantity that reaches the patient can change. In order to reduce the exposure dose of a patient, the research examines a method of reducing the exposure dose of a patient by controlling the pitch during a PET/CT exam, viewing whether the adjustment of the pitch influences CT image and PET SUV. Methods: The equipment used is a Biograph Positron Emission Tomography (PET) Scanner (CT type: TRCT-240-130 (WCT-240-130)) of Siemens company. For the evaluation of exposure dose of a patient, we measured radiation quantities using a PTW-DIADOS 11003/1383, which is a CT radiation measurement instrument used by Siemens. We measured and analyzed the space resolutions of CT images caused by the change of pitches using an AAPM Standard Phantom in order to see how the adjustment of pitches influenced the CT images. In addition, in order to obtain SUVs caused by each change of pitches using a PET source made with a solid radioactive cylinder phantom, we confirmed whether the SUVs changed in the PET/CT images by calculating the SUVs of the fusion images caused by the change of pitches after obtaining CT and PET images and finishing the test. Results: 2slice CT scanner showed that radiation quantities largely dropped when pitches ranged from 0.7 to 1.3 and that the reduction of radiation quantities were smaller when pitches ranged from 1.5 to 1.9. That is, we found that the bigger pitch values are the smaller the radiation quantities of a patient are. Moreover, we realized that there is no change of SUVs caused by the increase of pitches and that pitch values do not influence PET SUVs and the quality of CT images. It is judged that using 1.5 as a pitch value contributes to the reduction of exposure dose of a patient as long as there is no problem in the quality of an image. Conclusions: When seeing the result of the research, hospital using a PET/CT should make an effort to reduce the exposure dose of a patient seeking pitch values appropriate for their hospital within the range in which there is no image distortion and PET SUVs are not influenced from pitches. We think that the research can apply to all multi-detectors having a CT scanner and that such a research will be needed for other equipments in the future.

  • PDF

Quantitative CT Evaluation for Lung Volume and Density in Dogs (개에서 정량적 컴퓨터단층촬영을 이용한 폐용적과 폐밀도의 평가)

  • Choi, Soo-Young;Lee, In;Jeong, Woo-Chang;Heng, Hock Gan;Lee, Young-Won;Choi, Ho-Jung
    • Journal of Veterinary Clinics
    • /
    • v.31 no.5
    • /
    • pp.376-381
    • /
    • 2014
  • In this study, we analyzed the computed tomography (CT) measurements of lung volume and density in dogs with relation to body weight, age, sex, and breed. The multi-detector CT examination of the thorax was performed on dogs without respiratory or cardiovascular diseases. Three-dimensional reconstruction of CT images facilitated measurement of lung volume and density. There was a statistical significant correlation between body weight and lung volume (p < 0.0001). Lung density significantly decreased with an increase in body weight (p = 0.0078). However, no correlation was seen between these lung parameters and either sex or age of the dogs. In conclusion, this study shows that body weight is an important factor to consider when interpreting total lung volume and density values measured by quantitative CT. We highlight the need for further study using quantitative CT in identifying the potential effects of sex, age, and disease status on these parameters.

Preoperative Evaluation of the Facial Artery Using Facial Angio Computed Tomography (전산화단층촬영 혈관조영술을 이용한 얼굴동맥의 수술 전 평가)

  • Kim, Joo-Hak;Kang, Nak-Heon;Lee, In-Ho;Seo, Young-Joon;Yang, Ho-Jik;Song, Seung-Han;Oh, Sang-Ha
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.719-724
    • /
    • 2011
  • Purpose: Previous studies of the facial artery have shown significant anatomical variability in this region. The vascular anatomy of the region is considered unreliable in predicting the ideal pedicle. Preoperative imaging has been suggested as a means of improving preoperative awareness, with Doppler ultrasound as useful tools. Multi-detector row angiographic computed tomography (angio CT) is a significant improvement, providing noninvasive operator-independent details of the vascular anatomy. This tool was used to perform an $in$ $vivo$ anatomical study of the facial artery, demonstrating the usefulness of facial angio CT in planning the facial reconstruction. Methods: Eleven consecutive patients underwent facial angio CT of the facial vasculature with the anatomical details of the facial artery assessed. Results: Facial angio CT could demonstrate the size and course of the facial vasculature, particularly the facial artery. Conclusion: The vascular anatomy of the facial artery is highly variable, and thus there is a role for preoperative imaging. Facial angio CT can demonstrate cases where there is an aberrant or non-preferred anatomy, or select the method of a facial reconstruction.

Comparison of dental radiography and computed tomography: measurement of dentoalveolar structures in healthy, small-sized dogs and cats

  • Lee, Seunghee;Lee, Kichang;Kim, Hyeona;An, Jeongsu;Han, Junho;Lee, Taekwon;Jeong, Hogyun;Cho, Youngkwon
    • Journal of Veterinary Science
    • /
    • v.21 no.5
    • /
    • pp.75.1-75.8
    • /
    • 2020
  • Background: Dental diseases are common in dogs and cats, and accurate measurements of dentoalveolar structure are important for planning of treatment. The information that the comparison computed tomography (CT) with dental radiography (DTR) is not yet reported in veterinary medicine. Objectives: The purpose of this study was to compare the DTR with CT of dentoalveolar structures in healthy dogs and cats, and to evaluate the CT images of 2 different slice thicknesses (0.5 and 1.0 mm). Methods: We included 6 dogs (2 Maltese and 1 Spitz, Beagle, Pomeranian, mixed, 1 to 8 years, 4 castrated males, and 2 spayed female) and 6 cats (6 domestic short hair, 8 months to 3 years, 4 castrated male, and 2 spayed female) in this study. We measured the pulp cavity to tooth width ratio (P/T ratio) and periodontal space of maxillary and mandibular canine teeth, maxillary fourth premolar, mandibular first molar, maxillary third premolar and mandibular fourth premolar. Results: P/T ratio and periodontal space in the overall dentition of both dogs and cats were smaller in DTR compared to CT. In addition, CT images at 1.0 mm slice thickness was generally measured to be greater than the images at 0.5 mm slice thickness. Conclusions: The results indicate that CT with thin slice thickness provides more accurate information on the dentoalveolar structures. Additional DTR, therefore, may not be required for evaluating dental structure in small-sized dogs and cats.

Geometric Calibration of Cone-beam CT System for Image Guided Proton Therapy (영상유도 양성자치료를 위한 콘빔 CT 재구성 알고리즘: 기하학적 보정방법에 관한 연구)

  • Kim, Jin-Sung;Cho, Min-Kook;Cho, Young-Bin;Youn, Han-Bean;Kim, Ho-Kyung;Yoon, Myoung-Geun;Shin, Dong-Ho;Lee, Se-Byeung;Lee, Re-Na;Park, Sung-Yong;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.209-218
    • /
    • 2008
  • According to improved radiation therapy technology such as IMRT and proton therapy, the accuracy of patient alignment system is more emphasized and IGRT is dominated research field in radiation oncology. We proposed to study the feasibility of cone-beam CT system using simple x-ray imaging systems for image guided proton therapy at National Cancer Center. 180 projection views ($2,304{\times}3,200$, 14 bit with 127 ${\mu}m$ pixel pitch) for the geometrical calibration phantom and humanoid phantoms (skull, abdomen) were acquired with $2^{\circ}$ step angle using x-ray imaging system of proton therapy gantry room ($360^{\circ}$ for 1 rotation). The geometrical calibration was performed for misalignments between the x-ray source and the flat-panel detector, such as distances and slanted angle using available algorithm. With the geometrically calibrated projection view, Feldkamp cone-beam algorithm using Ram-Lak filter was implemented for CBCT reconstruction images for skull and abdomen phantom. The distance from x-ray source to the gantry isocenter, the distance from the flat panel to the isocenter were calculated as 1,517.5 mm, 591.12 mm and the rotated angle of flat panel detector around x-ray beam axis was considered as $0.25^{\circ}$. It was observed that the blurring artifacts, originated from the rotation of the detector, in the reconstructed toomographs were significantly reduced after the geometrical calibration. The demonstrated CBCT images for the skull and abdomen phantoms are very promising. We performed the geometrical calibration of the large gantry rotation system with simple x-ray imaging devices for CBCT reconstruction. The CBCT system for proton therapy will be used as a main patient alignment system for image guided proton therapy.

  • PDF