• Title/Summary/Keyword: Multi-Coil

Search Result 186, Processing Time 0.031 seconds

Characteristics Analysis of multi-separated winding LDM by Excitation Mode (여자 방식에 따른 다권선 LDM의 특성 해석)

  • Kim, J.P.;Baek, S.H.;Maeng, I.J.;Woo, Y.S.;Kim, I.N.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.804-806
    • /
    • 2001
  • In this paper, by designing ratio width of the permanent magnet versus the stator coil, double excitation LDM with multi-separated winding which is possible to obtain the constant thrust force is proposed. Using Empulse, this paper has explained a various excitation mode to analyze the thrust force of multi-separated winding LDM. The simulation results show single-phase excitation mode have low thrust force ripple.

  • PDF

High Density On-Board DC/DC Converter Using Multi-Layer PCB (다층 PCB를 이용한 고밀도 On-Board DC/DC Converter)

  • Kim Y.P.;Kim T.S.;Lim B.S.;Kim H.J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.781-784
    • /
    • 2003
  • In this paper, high density on-board dc/dc converter using multi-layer PCB is proposed. Recently, the communication system wants power supply of open-frame, high density and low profile. So experimental converter was consisted of 3.3V/30A Quarter Brick size DC/DC Converter. To power height limit, coil of transformer, choke and circuits were consisted of multi layer PCB. Besides to improve of efficiency, made secondary synchronous rectifier Mosfet driving circuit. So total efficiency could be improved.

  • PDF

The thrust characteristic analysis of multi-separated winding LDM (다중 분할 권선형 LDM의 추력 특성 해석)

  • Kim, Il-Nam;Lee, Sang-Cheol;Koo, Choon-Keun;Kang, Gu-Hong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.1
    • /
    • pp.1-9
    • /
    • 2002
  • This paper describes for new design method to improve respones characteristics of moving-magnet type LDM with volume reduction of slider back iron. To achieve the constant thrust of LDM through restraining saturation at the center core of stator excitation coil, double sided stator winding of LDM is proposed. We constructed new type LDM to prove the validity of design process. Analysis results through measurement and simulation of proposed multi-separated winding LDM were proved excellent in response characteristics and static thrust.

Characteristics of AC loss of Hybrid Multi-Stacking with HTS Wires in External Magnetic Field (고온초전도 혼합적층선재의 외부자장 변화에 따른 손실 특설)

  • Lim, Hyoung-Woo;Lee, Dong-Min;Yun, Ki-Hyun;Cha, Guee-Soo;Lee, Hee-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.71-73
    • /
    • 2006
  • AC loss on variation of external magnetic field is a very important factor in development of power applications. In this paper, we measured and compared AC loss of hybrid-multi stacked wire made of the combination of 1G wires and 2G wires and uniform-multi-stacked wire made of one type of wires, 1G wires or 2G wires. Measurement was performed using by the linked-picked coil method. As results, as the number of wires increase, AC loss per unit volume of both stacked wires in low external magnetic field is reduced. Also AC loss of 2G slacked wire is higher than that of 1G wire. AC loss per unit length of 2G stacked wire is less than that of 1G stacked wire. And AC loss of hybrid-multi stacked wire made of the combination of 1G wires and 2G wires was between uniform-multi-stacked wire made of 1G wires and 2G wires.

  • PDF

High-Order Surface Gradient Coil Design Using Target Field Approach

  • Lee, J.K.;Yang, Y.J.;Jeong, S.T.;Choi, H.J.;Cho, Z.H.;Oh, C.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.19-24
    • /
    • 1996
  • The purpose of this paper is to design high-order (or radial) surface gradient coil (SGC), which can provide multi-dimensional spatial selection. Although the spatial Selection with High-Order gradienT (SHOT) can provide a 2-D selection with only one selective RF pulse, the high-order gradient pro- duced by conventional cylindrical-shape coils has not been clinically useful due to the large selection size caused by the limited radial gradient intensity. However, by using the proposed high-order SGCs located near the imaging region, the size of volume selection can be reduced to a clinically useflll size of 1-2 cm in diameter by applying stronger radial gradient field with much less gradient driving power. So far radial SGCs have been designed by using the field component method and may cause distortion in the selection shapes. In this paper, by using the target field approach for the coil design, selected volumes became almost circular. A 40 cm-by-40 cm $z^2$_surface gradient coil has been designed and implemented by using the target field approach. Phantom and volunteer studies have been performed Experimental results using spatially localized MRI show good agreement to the theoretically predicted behavior.

  • PDF

Development of Control Algorithm and Pick & Placer (반도체 소자 Pick &Placer 및 제어 알고리즘 개발)

  • 심성보;김재희;유범상
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1339-1343
    • /
    • 2004
  • This paper presents a development of the control algorithm and Pick & Placer. The Pick & Placer provides a powerful multi-task system that includes both graphical and remote interface. Users can easily set up sorting parameters and record important data including wafer number, data, and operator information. This System sets up a dustproof device and massively machined components to provide an extremely stable sorting environment. Precise resolution and accuracy result from using machine vision, a pneumatic slide drive and close -looped positioning.

  • PDF

A Study on the Stabilization of Magnetically Auspended Bearing System (자기부상 베어링의 제어에 대한 연구)

  • 이교일;한동철;백승헌;이정훈;장인배
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.805-810
    • /
    • 1990
  • Optimal control systems for a radial magnetic bearing are proposed and tested. An electromagnet system model is developed to predict bearing forces as functions of changing coil currents and rotor position. Models of the multi-mass rotor supported by the magnetic bearings are developed and confirmed, and theoretical relationships are expressed in the form of state equation. As a result of computer simulation, the state feedback with optimal procedure is considered to be more effective for magnetic bearing systems than the classical method.

  • PDF

Comparative Analysis of Cartesian Trajectory and MultiVane Trajectory Using ACR Phantom in MRI : Using Image Intensity Uniformity Test and Low-contrast Object Detectability Test (ACR 팬텀을 이용한 Cartesian Trajectory와 MultiVane Trajectory의 비교분석 : 영상강도 균질성과 저대조도 검체 검출률 test를 사용하여)

  • Nam, Soon-Kwon;Choi, Joon-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.39-46
    • /
    • 2019
  • This study conducted a comparative analysis of differences between cartesian trajectory in a linear rectangular coordinate system and MultiVane trajectory in a nonlinear rectangular coordinate system axial T1 and axial T2 images using an American College of Radiology(ACR) phantom. The phantom was placed at the center of the head coil and the top-to-bottom and left-to-right levels were adjusted by using a level. The experiment was performed according to the Phantom Test Guidance provided by the ACR, and sagittal localizer images were obtained. As shown in Figure 2, slices # 1 and # 11 were scanned after placing them at the center of a $45^{\circ}$ wedge shape, and a total of 11 slices were obtained. According to the evaluation results, the image intensity uniformity(IIU) was 93.34% for the cartesian trajectory, and 93.19% for the MultiVane trajectory, both of which fall under the normal range in the axial T1 image. The IIU for the cartesian trajectory was 0.15% higher than that for the MultiVane trajectory. In axial T2, the IIU was 96.44% for the cartesian trajectory, and 95.97% for the MultiVane trajectory, which fall under the normal range. The IIU for the cartesian trajectory was by 0.47% higher than that for the MultiVane trajectory. As a result, the cartesian technique was superior to the MultiVane technique in terms of the high-contrast spatial resolution, image intensity uniformity, and low-contrast object detectability.

Multi-Channel Magnetic Nerve Stimulation System with Small Size Power Supplies (소규모 전원장치를 이용한 다채널 자기 신경자극 시스템)

  • 한병희;김기왕;이세호;조민형;이수열
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.2
    • /
    • pp.139-144
    • /
    • 2001
  • 자기 신경자극기는 신경의학, 재활의학을 포함한 많은 임상의학 분야에서 널리 쓰이고 있다. 자기 신경자극기는 전력소모가 크고 고압 전원이 필요한 이유 때문에 단채널 시스템만이 임상환경이나 연구환경에서 쓰여 왔었다. 본 논문에서는 4채널 자기 신경자극기 개발을 소개하였다. 고압 커패시터를 충전하는데 있어서 단계적 충전방식을 사용하여 작은 크기의 직류 전원장치로 다채널 시스템을 구현하였고, 채널별로 서로 다른 자극 프로토콜로 자극 코일을 구동할 수 있는 다채널 제어시스템을 구성하였다. 개발된 시스템은 신경계통 장애가 있는 환자들의 재활이나 자기적인 침술 등 다양한 기능적 자기 자극에 활용될 수 있을 것으로 기대된다.

  • PDF

A Design of Multi-Channel Biotelemetry for ECG Encoding and Transmission Over the Public Telephone Line (공중 전화회선용 다중 채널 ECG데이터 원격 측정시스템 설계)

  • Gye, Sin-Ung;Jang, Won-Seok;Hong, Seung-Hong
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.21-34
    • /
    • 1986
  • In this paper, we described the ECG telemetry system via the Public Telephone Line. The system consist of a signal acquisition and measurement section, a signal processing section, and a signal transmission section. It used 8 bits microprocessor. The transmission section is composed of 3 ch. analog modulators and 1 ct. digital modem. Especially, using the digital modem, signal is transmitted with about 50n data reduction ratio by the TP (Turning Point) algorithm. The acoustic coupler or inductive coil for linking the public telephone line are used. The speed of the digital modem is 300 baud rate. The MCBS (Multi Channel Biotelemetry System) is tested and evaluated through the experiment.

  • PDF