• Title/Summary/Keyword: Multi zone

Search Result 539, Processing Time 0.028 seconds

Static behaviour of lying multi-stud connectors in cable-pylon anchorage zone

  • Lin, Zhaofei;Liu, Yuqing;He, Jun
    • Steel and Composite Structures
    • /
    • v.18 no.6
    • /
    • pp.1369-1389
    • /
    • 2015
  • In order to investigate the behaviour of lying multi-stud connectors in cable-pylon anchorage zone, twenty-four push-out tests are carried out with different stud numbers and diameters. The effect of concrete block width and tensile force on shear strength is investigated using the developed and verified finite element model. The results show that the shear strength of the lying multi-stud connectors is reduced in comparison with the lying single-stud connector. The reduction increases with the increasing of the number of studs in the vertical direction. The influence of the stud number on the strength reduction of the lying multi-stud connectors is decreased under combined shear and tension loads compared with under pure shear. Yet, due to multi-stud effect, they still can't be ignored. The concrete block width has a non-negligible effect on the shear strength of the lying multi-stud connectors and therefore should be chosen properly when designing push-out specimens. No obvious difference is observed between the strength reductions of the studs with 22 mm and 25 mm diameters. The shear strengths obtained from the tests are compared with those predicted by AASHTO LRFD and Eurocode 4. Eurocode 4 generally gives conservative predictions of the shear strength, while AASHTO LRFD overestimates the shear strength. In addition, the lying multi-stud connectors with the diameters of 22 m and 25 mm both exhibit adequate ductility according to Eurocode 4. An expression of load-slip curve is proposed for the lying multi-stud connectors and shows good agreement with the test results.

Effect of the Boost Pressure on Thermal Stratification on HCCI Engine Using Multi-Zone Modeling (Multi zone Modeling을 이용한 흡기관내의 과급이 온도성층화를 갖는 예혼합압축자기착화엔진에 미치는 영향에 관한 연구)

  • Kwon, O-Seok;Lim, Ock-Taeck
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.4
    • /
    • pp.248-254
    • /
    • 2009
  • The HCCI engine is a next generation engine, with high efficiency and low emissions. The engine may be an alternative to SI and DI engines; however, a pressure rise rate is a major limitation for high load range and power reduction. Recently, we were able to reduce the pressure rise rate using thermal stratification. Nevertheless, this was insufficient to produce high power. In this study, the reduction of the pressure rise rate using thermal stratification was confirmed and the HCCI engine power was increased using the boost pressure. The rate and engine power were produced by CHEMKIN and modified SENKIN. As a result of increasing the boost pressure, a higher IMEP was attained while the pressure rise rate increased only slightly in the HCCI with thermal stratification.

The Low Height Looping Technology for Multi-chip Package in Wire Bonder (와이어 본더에서의 초저 루프 기술)

  • Kwak, Byung-Kil;Park, Young-Min;Kook, Sung-June
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.1 s.18
    • /
    • pp.17-22
    • /
    • 2007
  • Recent new packages such as MCP(Multi-Chip Package), QDP(Quadratic Die Package) and DDP(Dual Die Package) have stack type configuration. This kind of multi-layer package is thicker than single layer package. So there is need for the low height looping technology in wirebonder to make these packages thinner. There is stiff zone above ball in wirebonder wire which is called HAZ(Heat Affect Zone). When making low height loop (below $80\;{\mu}m$) with traditional forward loop, stiff wire in HAZ(Heat Affected Zone) above ball is bended and weakened. So the traditional forward looping method cannot be applied to low height loop. SSB(stand-off stitch) wire bonding method was applied to many packages which require very low loops. The drawback of SSB method is making frequent errors at making ball, neck damage above ball on lead and the weakness of ball bonding on lead. The alternative looping method is BNL(ball neckless) looping technology which is already applied to some package(DDP, QDP). The advantage of this method is faster in bonding process and making little errors in wire bonding compared with SSB method. This paper presents the result of BNL looping technology applied in assembly house and several issues related to low loop height consistence and BNL zone weakness.

  • PDF

Adaptive Multi-Layer Security Approach for Cyber Defense (사이버 방어를 위한 적응형 다중계층 보호체제)

  • Lee, Seong-kee;Kang, Tae-in
    • Journal of Internet Computing and Services
    • /
    • v.16 no.5
    • /
    • pp.1-9
    • /
    • 2015
  • As attacks in cyber space become advanced and complex, monotonous defense approach of one-one matching manner between attack and defense may be limited to defend them. More efficient defense method is required. This paper proposes multi layers security scheme that can support to defend assets against diverse cyber attacks in systematical and adaptive. We model multi layers security scheme based on Defense Zone including several defense layers and also discuss essential technical elements necessary to realize multi layers security scheme such as cyber threats analysis and automated assignment of defense techniques. Also effects of multi layers security scheme and its applicability are explained. In future, for embodiment of multi layers security scheme, researches about detailed architecture design for Defense Zone, automated method to select the best defense technique against attack and modeling normal state of asset for attack detection are needed.

Development of vision-based soccer robots for multi-agent cooperative systems (다개체 협력 시스템을 위한 비젼 기반 축구 로봇 시스템의 개발)

  • 심현식;정명진;최인환;김종환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.608-611
    • /
    • 1997
  • The soccer robot system consists of multi agents, with highly coordinated operation and movements so as to fulfill specific objectives, even under adverse situation. The coordination of the multi-agents is associated with a lot of supplementary work in advance. The associated issues are the position correction, prevention of communication congestion, local information sensing in addition to the need for imitating the human-like decision making. A control structure for soccer robot is designed and several behaviors and actions for a soccer robot are proposed. Variable zone defense as a basic strategy and several special strategies for fouls are applied to SOTY2 team.

  • PDF

Analytical Solution for Flow Field by Arbitrarily-Located Multi Injection-Pumping Wells

  • Yoo, In-Wook;Lee, Kang-Kun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.79-82
    • /
    • 2001
  • Analytical solutions have been derived to delineate the capture zone created by pumping wells for the remediation design of contaminated groundwater. These previous analytical solutions are often restricted to pumping wells only, specific well locations, a limited number of wells, and an isotropic aquifer. Analytical solution was developed to deal with arbitrarily located multi injection-pumping wells in an anisotropic homogeneous aquifer. The solution presented in this study provides a simple, easy method for determining tile complex flow field caused by multi injection-pumping wells at different rates, and will consequently be useful in pump-and-treat design.

  • PDF

Microstructural Characteristics of Zircaloy-4 Nuclear Fuel Cladding Welds by Resistance Upset Welding Processes (저항 업셋 용접방식에 따른 Zircaloy-4 핵연료 피복재 용접부의 미세조직 특성)

  • 고진현;김상호;박춘호;김수성
    • Journal of Welding and Joining
    • /
    • v.20 no.3
    • /
    • pp.98-104
    • /
    • 2002
  • A study on microstructures of welds for Zircaloy-4 sheath end closure by the resistance upset welding methods was carried out. Two upset welding process variations such as magnetic farce and multi-impulse resistance welding were used. Grain size and microhardness across welds were analysed in terms of welding parameters. Magnetic farce resistance weld with one cycle of unbalanced mode has smaller upset length and $\alpha-grain$ size in heat affected zone than those of multi-impulse resistance weld because of lower heat input and shorter welding time. Heat affected zone formed by two upset resistance welding variations revealed fine Widmanstatten structure or martensitic ${\alpha}'$ structure due to the high heating rate and foster cooling rate. Magnetic force resistance welds showed recrystallized grains before grain growth, whereas multi-impulse resistance welds showed full grain growth.

A Study on the Planning of Smoking Space in Apartment for the Rights of Smokers and Nonsmokers - Using the shaft space of the unit plan - (흡연자와 비흡연자의 권리보호를 위한 공동주택 내의 흡연 공간 계획에 관한 연구 - 동 평면의 샤프트 공간을 활용하여 -)

  • Kim, Tae-Hun;Bae, Si-Hwa;Suh, Sang-Wook;Choi, Hyun-Chul
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.33 no.12
    • /
    • pp.105-112
    • /
    • 2017
  • Through various media, damage of both smoking and second-hand smoking has been recognized, and brought global scale of interest in antismoking. In Korea, government has tightened regulations of smoking in non-smoking zone since December, 1980, and after National Health Promotion Act in 1995, non-smoking zone has been gradually expanded. On the other hand, there were law suits to find those regulation towards smokers are either unconstitutional or not for 4 times. In this current state, people need smoking area to prevent second-hand smoking and to consider smokers in multi-unit dwelling. Main purpose of this research is to plan smoking spaces based on various typology of multi-dwelling plan for protection of both smokers and non-smokers' right. The research group collected and analyzed the smoking behaviors in various multi-unit dwelling types such as flat type, tower type, hybrid type and others. Based on those data, the group found three phenomena. First, there are internal regulations in multi-unit dwelling to make non-smoking zone based on National Health Promotion Act and resident representative meeting decision. Second, main smoking activities are occurring at major traffic line and entrances. Third, smoking inside of multi-unit dwelling complex causes second-hand smoking to residents live in $1^{st}$ floor and when they enter. Therefore, one can achieve both smokers' and non-smokers' protection of right by creating a designated smoking space near main entrances of multi-unit dwelling complex to consider smokers' and prevents second-hand smoking by using shaft space, which is in core space, to ventilate tobacco smoke through roof.

An Experimental Study on the NOx Formation of Fuel Staged Combustor (연료다단 연소기의 NOx 발생특성에 관한 실험적 연구)

  • 정진도;안국영;한지웅
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.6
    • /
    • pp.73-79
    • /
    • 2003
  • The characteristics of NOx emission in multi fuel/air staged combustor have been experimentally studied. The design concept of multi fuel/air staged combustor is creation of two separate flame, a primary flame is act as a pilot flame for the secondary combustion stage combustion zone, where most of fuel burns. Experiments were performed on a semi-industrial scale (thermal input 0.233 ㎿) in a laboratory furnace and Liquefied Petroleum Gas(LPG) was used as primary and secondary fuels. The study included parametric study to identify the optimum operating conditions which are primary/secondary fuel ratio, primary/secondary air ratio, primary swirl intensity and secondary swirl intensity for reducing NOx emission. The test demonstrated that NOx emission can be reduced by >70% in accordance with operating conditions.

The experimental study on the NOx formation of fuel staged combustor (연료다단 연소기의 NOx 발생특성에 관한 실험적 연구)

  • Han, Ji-Woong;Ahn, Kook-Young;Kim, Han-Seok;Chung, Jin-Do
    • 한국연소학회:학술대회논문집
    • /
    • 2001.06a
    • /
    • pp.163-171
    • /
    • 2001
  • The characteristics of NOx emission in multi fuel/air staged combustor have been experimentally studied. The design concept of multi fuel/air staged combustor is creation of two separate flame, a primary flame is act as a pilot Dame for the secondary combustion stage combustion zone, where most of fuel bums. Experiments were performed on a semi-industrial scale (thermal input 0.233 MW) in a laboratory furnace and Liquefied Petroleum Gas(LPG) was used as primary and secondary fuels. The study included parametric study to identify the optimum operating conditions which are primary/secondary fuel ratio, primary/secondary air ratio, primary swirl intensity and secondary swirl intensity for reducing NOx emission. The test demonstrated that NOx emission can be reduced by ${>}$70% in accordance with operating conditions.

  • PDF