• Title/Summary/Keyword: Movement range

Search Result 1,189, Processing Time 0.031 seconds

Computer vision-based remote displacement monitoring system for in-situ bridge bearings robust to large displacement induced by temperature change

  • Kim, Byunghyun;Lee, Junhwa;Sim, Sung-Han;Cho, Soojin;Park, Byung Ho
    • Smart Structures and Systems
    • /
    • v.30 no.5
    • /
    • pp.521-535
    • /
    • 2022
  • Efficient management of deteriorating civil infrastructure is one of the most important research topics in many developed countries. In particular, the remote displacement measurement of bridges using linear variable differential transformers, global positioning systems, laser Doppler vibrometers, and computer vision technologies has been attempted extensively. This paper proposes a remote displacement measurement system using closed-circuit televisions (CCTVs) and a computer-vision-based method for in-situ bridge bearings having relatively large displacement due to temperature change in long term. The hardware of the system is composed of a reference target for displacement measurement, a CCTV to capture target images, a gateway to transmit images via a mobile network, and a central server to store and process transmitted images. The usage of CCTV capable of night vision capture and wireless data communication enable long-term 24-hour monitoring on wide range of bridge area. The computer vision algorithm to estimate displacement from the images involves image preprocessing for enhancing the circular features of the target, circular Hough transformation for detecting circles on the target in the whole field-of-view (FOV), and homography transformation for converting the movement of the target in the images into an actual expansion displacement. The simple target design and robust circle detection algorithm help to measure displacement using target images where the targets are far apart from each other. The proposed system is installed at the Tancheon Overpass located in Seoul, and field experiments are performed to evaluate the accuracy of circle detection and displacement measurements. The circle detection accuracy is evaluated using 28,542 images captured from 71 CCTVs installed at the testbed, and only 48 images (0.168%) fail to detect the circles on the target because of subpar imaging conditions. The accuracy of displacement measurement is evaluated using images captured for 17 days from three CCTVs; the average and root-mean-square errors are 0.10 and 0.131 mm, respectively, compared with a similar displacement measurement. The long-term operation of the system, as evaluated using 8-month data, shows high accuracy and stability of the proposed system.

Research on optimal safety ship-route based on artificial intelligence analysis using marine environment prediction (해양환경 예측정보를 활용한 인공지능 분석 기반의 최적 안전항로 연구)

  • Dae-yaoung Eeom;Bang-hee Lee
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2023.05a
    • /
    • pp.100-103
    • /
    • 2023
  • Recently, development of maritime autonomoust surface ships and eco-friendly ships, production and evaluation research considering various marine environments is needed in the field of optimal routes as the demand for accurate and detailed real-time marine environment prediction information expands. An algorithm that can calculate the optimal route while reducing the risk of the marine environment and uncertainty in energy consumption in smart ships was developed in 2 stages. In the first stage, a profile was created by combining marine environmental information with ship location and status information within the Automatic Ship Identification System(AIS). In the second stage, a model was developed that could define the marine environment energy map using the configured profile results, A regression equation was generated by applying Random Forest among machine learning techniques to reflect about 600,000 data. The Random Forest coefficient of determination (R2) was 0.89, showing very high reliability. The Dijikstra shortest path algorithm was applied to the marine environment prediction at June 1 to 3, 2021, and to calculate the optimal safety route and express it on the map. The route calculated by the random forest regression model was streamlined, and the route was derived considering the state of the marine environment prediction information. The concept of route calculation based on real-time marine environment prediction information in this study is expected to be able to calculate a realistic and safe route that reflects the movement tendency of ships, and to be expanded to a range of economic, safety, and eco-friendliness evaluation models in the future.

  • PDF

Inter-Lane Distance Measurement Method for Predicting the Lateral Movement of the Vehicle in Front (전방 차량의 횡간 이동 예측을 위한 차선 간 거리 측정 방법)

  • Sung-Jung Yong;Hyo-Gyeong Park;Seo-young Lee;Yeon-Hwi You;Il-Young Moon
    • Journal of Practical Engineering Education
    • /
    • v.14 no.3
    • /
    • pp.593-600
    • /
    • 2022
  • Various sensors such as lidar, radar, and camera are fused and used in autonomous vehicles. Rider and radar sensors are difficult to popularize because they are expensive equipment. In order to popularize autonomous vehicles, research that can replace expensive equipment is continuously being conducted. In this paper, we use a single camera that is inexpensive and can be easily mounted. We propose a method for detecting the wheels and adjacent lanes of a front-side vehicle of a driving vehicle and estimating distances. Our proposed method detects lanes and wheels from frame images after frame extraction via input images. In addition, the distance is measured and compared with the actual distance measured in the actual road environment. The distance could be calculated relatively accurately within the error range of ± 3 cm. Through this, it is expected that the camera can be used as an alternative means when the cost of autonomous vehicles is reduced or when the lidar or radar sensor fails.

Low-dose Chest CT in Evaluation of Coronary Artery Calcification: Correlation with Coronary Artery Calcium Score CT (관상동맥 석회화 평가에서 저선량 흉부 CT와 관상동맥 석회화검사의 일치도)

  • Yon-Min Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1033-1039
    • /
    • 2023
  • Low-dose chest CT, which is used as a lung screening test, also includes information on coronary artery calcification within the scan range. The purpose of this study was to investigate the usefulness of determining coronary artery calcification using Low-dose chest CT. Those who underwent low-dose chest CT and coronary artery calcification score CT on the same day were eligible. Coronary artery calcium score CT results were divided into 4 groups (Low: 1〈CACS〈10, Mild: 10〈CACS〈100, Moderate: 100〈CACS〈400, High: 400〈CACS) by referring to the Coronary artery calcium score categories and risks. After selecting 30 people each group, five radiotechnologists with more than 15 years of experience in coronary artery calcium measurement retrospectively analyzed the presence or absence of coronary artery calcification in low-dose chest CT images. The results of the five observers' uniform interpretation of the low-dose chest CT image were consistent with the coronary artery calcium score CT results in Low group: 56%, Mild group: 96.6%, Moderate group: 100%, and High group: 100%. appeared. In the Low group, all 5 observers observed calcification in 17 out of 30 cases, and in 7 cases all 5 observers decided that calcification could not be identified. Coronary artery calcification could be observed in 100% of asymptomatic adults with a calcium score of 15 or higher in low-dose chest CT scans. The minimum calcium score that can be identified is 1, and it was found that even very small calcifications can be identified when the subject's body size is small or the scan is performed at a time when heart movement is minimal.

Pharmacoacupuncture for the Treatment of Frozen Shoulder: protocol for a systematic review and meta-analysis

  • Ji-Ho Lee;Hyeon-Sun Park;Sang-Hyeon Park;Dong-Ho Keum;Seo-Hyun Park
    • Journal of Pharmacopuncture
    • /
    • v.27 no.1
    • /
    • pp.14-20
    • /
    • 2024
  • Objectives: Frozen shoulder (FS) is one of the most challenging shoulder disorders for patients and clinicians. Its symptoms mainly include any combination of stiffness, nocturnal pain, and limitation of active and passive glenohumeral joint movement. Conventional treatment options for FS are physical therapy, nonsteroidal anti-inflammatory drugs, injection therapy, and arthroscopic capsular release, but adverse and limited effects continue to present problems. As a result, pharmacoacupuncture (PA) is getting attention as an alternative therapy for patients with FS. PA is a new form of acupuncture treatment in traditional Korean medicine (TKM) that is mainly used for musculoskeletal diseases. It has similarity and specificity compared to corticosteroid injection and hydrodilatation, making it a potential alternative injection therapy for FS. However, no systematic reviews investigating the utilization of PA for FS have been published. Therefore, this review aims to standardize the clinical use of PA for FS and validate its therapeutic effect. Methods: The protocol was registered in Prospero (CRD42023445708) on 18 July 2023. Until Aug. 31, 2023, seven electronic databases will be searched for randomized controlled trials of PA for FS. Authors will be contacted, and manual searches will also be performed. Two reviewers will independently screen and collect data from retrieved articles according to predefined criteria. The primary outcome will be pain intensity, and secondary outcomes will be effective rate, Constant-Murley Score, Shoulder Pain and Disability Index, range of motion, quality of life, and adverse events. Bias and quality of the included trials will be assessed using the Cochrane handbook's risk-of-bias tool for randomized trials. Meta analyses will be conducted using Review Manager V.5.3 software. GRADE will be used to evaluate the level of evidence for each outcome. Results: This systematic review and meta-analysis will be conducted following PRISMA statement. The results will be published in a peer-reviewed journal. Conclusion: This review will provide scientific evidence to support health insurance policy as well as the standardization of PA in clinical practice.

Usefulness of Abdominal Compressor Using Stereotactic Body Radiotherapy with Hepatocellular Carcinoma Patients (토모테라피를 이용한 간암환자의 정위적 방사선치료시 복부압박장치의 유용성 평가)

  • Woo, Joong-Yeol;Kim, Joo-Ho;Kim, Joon-Won;Baek, Jong-Geal;Park, Kwang-Soon;Lee, Jong-Min;Son, Dong-Min;Lee, Sang-Kyoo;Jeon, Byeong-Chul;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.157-165
    • /
    • 2012
  • Purpose: We evaluated usefulness of abdominal compressor for stereotactic body radiotherapy (SBRT) with unresectable hepatocellular carcinoma (HCC) patients and hepato-biliary cancer and metastatic liver cancer patients. Materials and Methods: From November 2011 to March 2012, we selected HCC patients who gained reduction of diaphragm movement >1 cm through abdominal compressor (diaphragm control, elekta, sweden) for HT (Hi-Art Tomotherapy, USA). We got planning computed tomography (CT) images and 4 dimensional (4D) images through 4D CT (somatom sensation, siemens, germany). The gross tumor volume (GTV) included a gross tumor and margins considering tumor movement. The planning target volume (PTV) included a 5 to 7 mm safety margin around GTV. We classified patients into two groups according to distance between tumor and organs at risk (OAR, stomach, duodenum, bowel). Patients with the distance more than 1 cm are classified as the 1st group and they received SBRT of 4 or 5 fractions. Patients with the distance less than 1 cm are classified as the 2nd group and they received tomotherapy of 20 fractions. Megavoltage computed tomography (MVCT) were performed 4 or 10 fractions. When we verify a MVCT fusion considering priority to liver than bone-technique. We sent MVCT images to Mim_vista (Mimsoftware, ver .5.4. USA) and we re-delineated stomach, duodenum and bowel to bowel_organ and delineated liver. First, we analyzed MVCT images to check the setup variation. Second we compared dose difference between tumor and OAR based on adaptive dose through adaptive planning station and Mim_vista. Results: Average setup variation from MVCT was $-0.66{\pm}1.53$ mm (left-right) $0.39{\pm}4.17$ mm (superior-inferior), $0.71{\pm}1.74$ mm (anterior-posterior), $-0.18{\pm}0.30$ degrees (roll). 1st group ($d{\geq}1$) and 2nd group (d<1) were similar to setup variation. 1st group ($d{\geq}1$) of $V_{diff3%}$ (volume of 3% difference of dose) of GTV through adaptive planing station was $0.78{\pm}0.05%$, PTV was $9.97{\pm}3.62%$, $V_{diff5%}$ was GTV 0.0%, PTV was $2.9{\pm}0.95%$, maximum dose difference rate of bowel_organ was $-6.85{\pm}1.11%$. 2nd Group (d<1) GTV of $V_{diff3%}$ was $1.62{\pm}0.55%$, PTV was $8.61{\pm}2.01%$, $V_{diff5%}$ of GTV was 0.0%, PTV was $5.33{\pm}2.32%$, maximum dose difference rate of bowel_organ was $28.33{\pm}24.41%$. Conclusion: Despite we saw diaphragm movement more than 5 mm with flouroscopy after use an abdominal compressor, average setup_variation from MVCT was less than 5 mm. Therefore, we could estimate the range of setup_error within a 5 mm. Target's dose difference rate of 1st group ($d{\geq}1$) and 2nd group (d<1) were similar, while 1st group ($d{\geq}1$) and 2nd group (d<1)'s bowel_organ's maximum dose difference rate's maximum difference was more than 35%, 1st group ($d{\geq}1$)'s bowel_organ's maximum dose difference rate was smaller than 2nd group (d<1). When applicating SBRT to HCC, abdominal compressor is useful to control diaphragm movement in selected patients with more than 1 cm bowel_organ distance.

  • PDF

Home-ranges of Female Pipistrellus abramus (Chiroptera: Vespertilionidae) in Different Reproductive Stages Revealed by Radio-telemetry (원격무선추적을 이용한 집박쥐 암컷의 번식단계에 따른 행동권 분석)

  • Chung, Chul-Un;Han, Sang-Hoon;Kim, Sung-Dae;Lim, Chun-Woo;Kim, Sung-Chul;Kim, Chul-Young;Lee, Hwa-Jin;Kwon, Yong-Ho;Kim, Young-Chae;Lee, Chong-Il
    • Korean Journal of Environment and Ecology
    • /
    • v.25 no.1
    • /
    • pp.1-9
    • /
    • 2011
  • In order to analyze the change in home ranges depending on the reproductive stage of Pipistrellus abramus, radio-tracking was carried out for a total of 9 individuals, 3 individuals each, by dividing stages into a pregnancy stage, lactation stage, and post-lactation stage from May to August 2009. For radio-telemetry, 0.38g transmitters, R2000 receivers and 3-element Yagi antennas were used. Pipistrellus abramus were captured using a double-stacked mist net and a harp-trap. Analysis of home ranges used a SHP File and ArcGIS 3.3 for GIS, and used a Kernel Home Range Method(KHR) and a Minimum Convex Polygon(MCP) Method for analysis. Home ranges at the pregnancy stage were MCP 100% $13.46{\pm}1.84ha$, MCP 95% $12.28{\pm}2.15ha$, KHR 50% $3.00{\pm}0.71ha$, and home ranges at the lactation stage were MCP 100% $8.13{\pm}0.23ha$, MCP 95% $7.73{\pm}0.63ha$, KHR 50%$1.84{\pm}1.05ha$. Home ranges at the post-lactation stage were MCP 100% $125.58{\pm}97.77ha$, MCP 95% $123.89{\pm}97.73ha$, KHR 50% $28.61{\pm}26.78ha$. As a result, home ranges of pipistrellus abramus showed a significant difference in all of the MCP 100%, MCP 95%, KHR 50% depending on reproductive stages, being largest in the post-lactation stage and smallest in the lactation stage.

Two stage reconstruction of bilateral alveolar cleft using Y-shaped anterior based tongue flap and iliac bone graft (Y-형 전방 기저 설 피판과 장골 이식을 이용한 양측성 치조열의 이단계 재건술)

  • Lee, Jong-Ho;Kim, Myung-Jin;Kang, Jin-Han;Kang, Na-Ra;Lee, Jong-Hwan;Choi, Won-Jae;Choi, Jin-Young
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.3 no.1
    • /
    • pp.23-31
    • /
    • 2000
  • Objective: When an alveolar cleft is too large to close with adjacent mucobuccal flaps or large secondary fistula following a primary bilateral palatoplasty exists, a one-stage procedure for bone grafting becomes challenging. In such a case, we used the tongue flap to repair the fistula and cleft alveolus in the first stage, and bone grafting to the cleft defect was performed in the second stage several months later. The purpose of this paper is to report our experiences with the use of an anteriorly-based Y-shaped tongue flap to fit the palatal and labial alveolar defects and the ultimate result of the bone graft. Patients: A series of 14 patients underwent surgery of this type from January 1994 to December 1998.The average age of the patients was 15.8 years old (range: 5 to 28 years old). The mean period of follow-up following the 2nd stage bone raft operation was 45.9 months (range: 9 to 68 months). In nine of the 14 cases, the long-fork type of a Yshaped tongue flap was used for extended coverage of the labial side alveolar defects with the palatal fistula in the remaining cases the short-forked design was used. Results: All cases demonstrated a good clinical result after the initial repair of cleft alveolus and palatal fistula. There was no fistula recurrence, although Partial necrosis of distal margin in long-forked tongue flap was occurred in one case. Furthermore, the bone graft, which was performed an average of 8 months after the tongue flap repair, was always successful. Occasionally, the transferred tongue tissue was bulging and interfering with the hygienic care of nearby teeth; however, these problems were able to be solved with proper contour-pasty performed afterwards. No donor site complications such as sensory disturbance, change in taste, limitations in tongue movement, normal speech impairments or tongue disfigurement were encountered. Conclusion: This two-stage reconstruction of a bilateral cleft alveolus using a Y-shaped tongue flap and iliac bone graft was very successful. It may be indicated for a bilateral cleft alveolus patient where the direct closure of the cleft defect with adjacent tissue or the buccal flap is not easy due to scarred fibrotic mucosa and/or accompanied residual palatal fistula.

  • PDF

Structural Relationships Among Factors to Adoption of Telehealth Service (원격의료서비스 수용요인의 구조적 관계 실증연구)

  • Kim, Sung-Soo;Ryu, See-Won
    • Asia pacific journal of information systems
    • /
    • v.21 no.3
    • /
    • pp.71-96
    • /
    • 2011
  • Within the traditional medical delivery system, patients residing in medically vulnerable areas, those with body movement difficulties, and nursing facility residents have had limited access to good healthcare services. However, Information and Communication Technology (ICT) provides us with a convenient and useful means of overcoming distance and time constraints. ICT is integrated with biomedical science and technology in a way that offers a new high-quality medical service. As a result, rapid technological advancement is expected to play a pivotal role bringing about innovation in a wide range of medical service areas, such as medical management, testing, diagnosis, and treatment; offering new and improved healthcare services; and effecting dramatic changes in current medical services. The increase in aging population and chronic diseases has caused an increase in medical expenses. In response to the increasing demand for efficient healthcare services, a telehealth service based on ICT is being emphasized on a global level. Telehealth services have been implemented especially in pilot projects and system development and technological research. With the service about to be implemented in earnest, it is necessary to study its overall acceptance by consumers, which is expected to contribute to the development and activation of a variety of services. In this sense, the study aims at positively examining the structural relationship among the acceptance factors for telehealth services based on the Technology Acceptance Model (TAM). Data were collected by showing audiovisual material on telehealth services to online panels and requesting them to respond to a structured questionnaire sheet, which is known as the information acceleration method. Among the 1,165 adult respondents, 608 valid samples were finally chosen, while the remaining were excluded because of incomplete answers or allotted time overrun. In order to test the reliability and validity of the assessment scale items, we carried out reliability and factor analyses, and in order to explore the causal relation among potential variables, we conducted a structural equation modeling analysis using AMOS 7.0 and SPSS 17.0. The research outcomes are as follows. First, service quality, innovativeness of medical technology, and social influence were shown to affect perceived ease of use and perceived usefulness of the telehealth service, which was statistically significant, and the two factors had a positive impact on willingness to accept the telehealth service. In addition, social influence had a direct, significant effect on intention to use, which is paralleled by the TAM used in previous research on technology acceptance. This shows that the research model proposed in the study effectively explains the acceptance of the telehealth service. Second, the research model reveals that information privacy concerns had a insignificant impact on perceived ease of use of the telehealth service. From this, it can be gathered that the concerns over information protection and security are reduced further due to advancements in information technology compared to the initial period in the information technology industry, and thus the improvement in quality of medical services appeared to ensure that information privacy concerns did not act as a prohibiting factor in the acceptance of the telehealth service. Thus, if other factors have an enormous impact on ease of use and usefulness, concerns over these results in the initial period of technology acceptance may become irrelevant. However, it is clear that users' information privacy concerns, as other studies have revealed, is a major factor affecting technology acceptance. Thus, caution must be exercised while interpreting the result, and further study is required on the issue. Numerous information technologies with outstanding performance and innovativeness often attract few consumers. A revised bill for those urgently in need of telehealth services is about to be approved in the national assembly. As telemedicine is implemented between doctors and patients, a wide range of systems that will improve the quality of healthcare services will be designed. In this sense, the study on the consumer acceptance of telehealth services is meaningful and offers strong academic evidence. Based on the implications, it can be expected to contribute to the activation of telehealth services. Further study is needed to assess the acceptance factors for telehealth services, such as motivation to remain healthy, health care involvement, knowledge on health, and control of health-related behavior, in order to develop unique services according to the categorization of customers based on health factors. In addition, further study may focus on various theoretical cognitive behavior models other than the TAM, such as the health belief model.

Development of Movement Analysis Program and its Feasibility Test in Streotactic Body Radiation Threrapy (복부부위의 체부정위방사선치료시 호흡에 의한 움직임분석 프로그램 개발 및 유용성 평가)

  • Shin, Eun-Hyuk;Han, Young-Yih;Kim, Jin-Sung;Park, Hee-Chul;Shin, Jung-Suk;Ju, Sang-Gyu;Lee, Ji-Hea;Ahn, Jong-Ho;Lee, Jai-Ki;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.107-116
    • /
    • 2011
  • Respiratory gated radiation therapy and stereotactic body radiation therapy require identical tumor motions during each treatment with the motion detected in treatment planning CT. Therefore, this study developed a tumor motion monitoring and analysis system during the treatments employing RPM data, gated setup OBI images and a data analysis software. A respiratory training and guiding program which improves the regularity of breathing was used to patients. The breathing signal was obtained by RPM and the recorded data in the 4D console was read after treatment. The setup OBI images obtained gated at 0% and 50% of breathing phases were used to detect the tumor motion range in crenio-caudal direction. By matching the RPM data recorded at the OBI imaging time, a factor which converts the RPM motion to the tumor motion was computed. RPM data was entered to the institute developed data analysis software and the maximum, minimum, average of the breathing motion as well as the standard deviation of motion amplitude and period was computed. The computed result is exported in an excel file. The conversion factor was applied to the analyzed data to estimate the tumor motion. The accuracy of the developed method was tested by using a moving phantom, and the efficacy was evaluated for 10 stereotactic body radiation therapy patients. For the sine wave motion of the phantom with 4 sec of period and 2 cm of peak-to-peak amplitude, the measurement was slightly larger (4.052 sec) and the amplitude was smaller (1.952 cm). For patient treatment, one patient was evaluated not to qualified to SBRT due to the usability of the breathing, and in one patient case, the treatment was changed to respiratory gated treatment due the larger motion range of the tumor than treatment planed motion. The developed method and data analysis program was useful to estimate the tumor motion during treatment.