• 제목/요약/키워드: Movement range

검색결과 1,195건 처리시간 0.029초

집단동작훈련이 시설노인의 생리, 심리적 변수 및 관절운동범위에 미치는 영향 (The Effects of Group Movement Training on Psychophysiological Variables and the Range of Motion in the Institutionalized Elderly)

  • 서부덕
    • 지역사회간호학회지
    • /
    • 제20권4호
    • /
    • pp.403-411
    • /
    • 2009
  • Purpose: The purpose of this study is to explore the effects of a group movement exercise program on psychophysiological variables in the institutionalized elderly. Methods: This research adopted the non-equivalent control group pretest-posttest design. Twenty elders were selected as an experimental group, whereas twenty-two elders were as a control group. The group movement program consisted of 35 minutes of dance and three days a week for eight weeks. Resting systolic blood pressure, diastolic blood pressure and heart rate were measured in a relaxed sitting position. The range of flexion and extension of joint was measured with a gonimeter. Life satisfaction and self-efficacy were measured by self-report. Data were analyzed through $x^2$-test, t-test and ANCOVA using SPSS/WIN program. Results: The results were as follows: Resting systolic blood pressure, diastolic blood pressure and resting heart rate decreased significantly by the group movement training. The range of flexion and extension of the shoulder and hip joints increased significantly. The scores of life satisfaction and self-efficacy increased remarkably by the group movement. Conclusion: The results suggest that group movement training can be an effective intervention to improve psychophysiological variables and the range of motion for the institutionalized elderly.

  • PDF

Effects of Active Movement with Skin Mobilization on Range of Motion, Pain, RPE on Patients with Axillary Web Syndrome: A Case Study

  • Su-Hong Choi
    • Physical Therapy Rehabilitation Science
    • /
    • 제11권4호
    • /
    • pp.430-435
    • /
    • 2022
  • Objective: This study was conducted to investigate the effect of active movement with skin mobilization on range of motion, pain, and rating of perceived exertion in patients diagnosed with axillary web syndrome after axillary lymph node dissection. Design: A Case report Methods: It was performed on 7 patients diagnosed with axillary web syndrome after lymph node dissection. The subjects experienced a decrease in the range of joint motion and pain in movement when raising their arms in their daily lives, and complained of discomfort. The active range of motion, numeric rating scale, and modified Borg scale of shoulder joint flexion were measured, and the differences after active movement with skin mobilization were compared. Results: All subjects increased by 24.9 degree on average in active range of motion after active movement with skin mobilization intervention. There was no pain in the maximum range of joint motion measured before intervention, and rating of perceived exertion was significantly reduced. Conclusions: Active movement with skin mobilization can be a very useful way to help improve and treat axillary web syndrome, and it is recommended for improving the function and quality of life of axillary web syndrome patients. and It is also believed that it can be used steadily at home through the education of patients and families.

반조절성교합기와 구강에서의 운동 오차에 대한 비교 연구 (A study on the difference of movement between Semi adjustable articulator and Oral in vivo)

  • 문희경
    • 대한치과기공학회지
    • /
    • 제28권1호
    • /
    • pp.53-59
    • /
    • 2006
  • The movement range on the semi adjustable articulator and the movement range in an oral were measured. And then I studied to analyze the gap. I got wax records by the movement on the semi adjustable articulator, the movement in an oral. I measured the distance of the cusp tips that are close to the mesial direction and the distal direction, the buccal direction and the lingual direction then I compared gaps. As I saw results on data, I knew that the semi adjustable articulator represented the range of mandibular movement restrictively. I could find the decisive contradiction that the sliding movement finished on the semi adjustable articulator although it did not finish in an oral. When the sliding movement does not reappear exactly, it brings a fatal failure to the dental prosthesis. In addition it is impossible that the semi adjustable articulator restores the movement in an oral because the lateral condyle inclination and the horizontal condyle inclination are appeared to be straight. Therefore dental prosthesisses were made by the semi adjustable articulator, they will interfere with a mastication. I have obtained the following results; 1. The distance of sliding movement on the semi adjustable articulator showed shorter than the distance of sliding movement in oral. This means the increase of cusp inclination of the dental prosthesis that was made on the semi adjustable articulator. Therefore, when the lateral movement occurs in oral, there is a possibility to become the premature as the increase of cusp inclination. 2. The difference in the range of movement is considered as the gap that is made because the movement only can be occurred as straight in the semi adjustable articulator. 3. When the dental technician understand mandibular movement and articulator deficiencies, they can attain proficiency in use of the articulator and reduce the gap.

  • PDF

Analysis of fluctuations in ex-core neutron detector signal in Krško NPP during an earthquake

  • Tanja Goricanec;Andrej Kavcic;Marjan Kromar;Luka Snoj
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.575-600
    • /
    • 2024
  • During an earthquake on December 29th 2020, the Krško NPP automatically shutdown due to the trigger of the negative neutron flux rate signal on the power range nuclear instrumentation. From the time course of the detector signal, it can be concluded that the fluctuation in the detector signal may have been caused by the mechanical movement of the ex-core neutron detectors or the pressure vessel components rather than the actual change in reactor power. The objective of the analysis was to evaluate the sensitivity of the neutron flux at the ex-core detector position, if the detector is moved in the radial or axial direction. In addition, the effect of the core barrel movement and core inside the baffle movement in the radial direction were analysed. The analysis is complemented by the calculation of the thermal and total neutron flux gradient in radial, axial and azimuthal directions. The Monte Carlo particle transport code MCNP was used to study the changes in the response of the ex-core detector for the above-mentioned scenarios. Power and intermediate-range detectors were analysed separately, because they are designed differently, positioned at different locations, and have different response characteristics. It was found that the movement of the power range ex-core detector has a negligible effect on the value of the thermal neutron flux in the active part of the detector. However, the radial movement of the intermediate-range detector by 5 cm results in 7%-8% change in the thermal neutron flux in the active part of the intermediate-range detector. The analysis continued with an evaluation of the effects of moving the entire core barrel on the ex-core detector response. It was estimated that the 2 mm core barrel radial oscillation results in ~4% deviation in the power and intermediate-range detector signal. The movement of the reactor core inside baffle can contribute ~6% deviation in the ex-core neutron detector signal. The analysis showed that the mechanical movement of ex-core neutron detectors cannot explain the fluctuations in the ex-core detector signal. However, combined core barrel and reactor core inside baffle oscillations could be a probable reason for the observed fluctuations in the ex-core detector signal during an earthquake.

단순교합기에 의한 하악운동의 오차에 대한 실험적 연구 (An Experimental study on the gap of movement by the hinge articulator)

  • 문희경
    • 대한치과기공학회지
    • /
    • 제25권1호
    • /
    • pp.111-118
    • /
    • 2003
  • I measured the movement range on the hinge articulator and the movement range in an oral. And then I studied to analyze the gap. I got wax records by the movement on the hinge articulator, the movement in an oral and the movement on the hand articulating. I measured the distance of the cusp tips that are close to the mesial direction and the distal direction, the buccal direction and the lingual direction then I compared gaps. As I saw results on data, I knew that the hinge articulator represented the range of mandibular movement restrictively. I could find the decisive contradiction that the sliding movement finished on the hinge articulator although it did not finish in an oral. If the sliding movement does not reappear exactly, it brings a fatal failure to the dental prosthesis. In addition it is impossible that the hinge articulator restores the movement in an oral because the lateral condyle inclination and the horizontal condyle inclination are fixed previously. Therefore dental prosthesisses were made by the hinge articulator, they will interfere with a mastication. I have obtained the following results; 1. The distance of sliding movement on the hinge articulator showed shorter than the distance of sliding movement in oral. This means the increase of cusp inclination of the dental prosthesis that was made on the hinge articulator. Therefore, when the lateral movement occurs in oral, there is a possibility to become the premature as the increase of cusp inclination. 2. The results that were impressed records in oral and impressed records on the hand articulating have many congruities. I think that the simple crown etc. that were made by the hand articulating method except the long span bridge and the free end case that can not measure the vertical dimension exactly can represent similarly the mandibular movement. 3. If we want to represent the mandibular movement similarly, we have to use the articulator that can adjust the horizontal condyle inclination and the lateral condyle inclination at least.

  • PDF

Quantitative study of acupuncture manipulation of lifting-thrusting using an needle insertion-measurement system in phantom tissue

  • Lee, Soo-Yoon;Son, Young-Nam;Choi, In-Hwa;Shin, Kyung-Min;Kim, Kap-Sung;Lee, Seung-Deok
    • 대한한의학회지
    • /
    • 제35권4호
    • /
    • pp.74-82
    • /
    • 2014
  • Objectives: Quantification, objectification, and standardization of lifting-thrusting manipulation are important issues in traditional Chinese medicine (TCM). The purpose of this study was to quantitatively investigate the difference in the amount of stimulation according to range and frequency among parameters of lifting-thrusting manipulation with the use of a needle insertion-measurement system. Methods: For quantification of lifting-thrusting manipulation, an acupuncture needle insertion-measurement system was used in phantom tissue. The motor and force sensors of the needle insertion device were connected to the control software. This enabled operation of the lifting-thrusting manipulation and measurement of the acupuncture needle force. The measurement of the acupuncture needle force according to various frequencies (0.25, 0.50, 0.75, and 1 Hz) and ranges of movement (2, 4, 6, 8, and 10 mm) was repeated 10 times. Results: At a constant frequency of movement, acupuncture needle force according to range of movement (2, 4, 6, 8, and 10 mm) increased with increasing range of movement (p < 0.05). At a constant range of movement, acupuncture needle force according to frequency of movement (0.25, 0.50, 0.75, and 1.0 Hz) increased with increasing frequency of movement (p < 0.05). Conclusion: In this study, we conducted a quantitative comparison of the amount of stimulation according to range and frequency, the main parameters of lifting-thrusting manipulation, by using an acupuncture needle insertion-measurement system. Future studies on various manipulations and parameters are warranted to quantify and objectify the amounts of stimulation by acupuncture manipulation.

수정된 PNF 발목 움직임 패턴이 능동적 발등 굽힘 가동범위 및 다리 근활성도에 미치는 영향 (The Effects of Modified PNF Ankle Movement Patterns on Active Dorsiflexion Range of Motion and Leg Muscle Activity)

  • 김인균;최수홍;이상열
    • PNF and Movement
    • /
    • 제21권3호
    • /
    • pp.319-326
    • /
    • 2023
  • Purpose: The purpose of this study was to investigate the effects of modified ankle movement patterns on participants' active dorsiflexion range of motion and leg muscle activity. Methods: This study recruited twenty-five participants, all of whom were healthy individuals with no abnormalities in the ankle or knee joints. The research methodology involved measuring the active dorsiflexion range of motion and muscle activity in each person's legs based on the presence or absence of toe extension while the subjects were in a comfortable, supine position. A statistical analysis was conducted using SPSS 25.0, and a paired samples t-test was employed. The significance level was set at 0.05. Results: When the participants demonstrated the modified ankle movement pattern with a controlled toe grip, there was an increase in their active dorsiflexion angle. However, during the proprioceptive neuromuscular facilitation technique without a controlled toe grip, a higher level of activity was observed in the leg muscles. Conclusion: The results of this study could be used as foundational data for establishing a rehabilitation exercise program designed to enhance range of motion and muscle activation in the ankle joint.

뇌졸중 후 편마비 환자의 건측억제-환측유도 운동이 환측 상지기능에 미치는 효과 (The Effects of Constraint-induced Movement Therapy on Affected Upper Limb Functions in Patients with Hemiplegia)

  • 유광수;배정희
    • 지역사회간호학회지
    • /
    • 제17권4호
    • /
    • pp.482-491
    • /
    • 2006
  • Purpose: Hemiplegia patients who were attacked by a stroke suffer from hemiplegic disabilities as well as motor disabilities. For them, rehabilitation cure is being carried out broadly. However, it is not enough for them to use the upper extremity than the lower extremity. For the use of the upper extremity, we examined the effect of constraint-induced movement therapy developed in this research on patients who experienced a stroke following hemiplegia. Method: For this study we selected 36 stroke patients who were registered at the community health center through accidental sampling, and assigned 21 of them to the experimental group, and 15 to the control group. The experimental group had constraint-induced movement therapy for 5 days and 7 hours a day from 9 to o'clock in the morning 9 to 4 o'clock in the afternoon 4 including warmup exercise and main exercise in the rehabilitation room, whereas the control group were restricted. Result: As a result of constraint-induced movement therapy, affected side elbow joint flexion range, side shoulder joint extension range and side shoulder joint of the flexion range of motions increased obviously in the experimental group compared to those in the control group. Conclusion: The result above clearly shows that constraint-induced movement therapy is an effective intervention for the rehabilitation of hemiplegia patients in increasing affected side elbow joint of the flexion range of motion, the shoulder joint extension, and the increase of flexion range of motion.

  • PDF

발등굽힘 관절가동범위 제한이 착지 시 움직임 전략에 미치는 영향 (Effects of Limited Dorsiflexion Range of Motion on Movement Strategies during Landing)

  • Inje Lee;Donggun Kim;Hyeondeukje Kim;Hyunsol Shin;Jiwon Lee;Yujin Jang;Myeongwoo Pi
    • 한국운동역학회지
    • /
    • 제33권4호
    • /
    • pp.147-154
    • /
    • 2023
  • Objective: This study aimed 1) to compare the Landing Error Scoring System (LESS) score and movement patterns during landing of the lesser dorsiflexion range of motion (LDFROM) group to that with the greater dorsiflexion range of motion group, and 2) to identify the correlation between the weight-bearing dorsiflexion range of motion (WBDF ROM), LESS score, and movement patterns during landing. Method: Fifty health adults participated in this study. WBDF ROM was measured using the weight bearing lunge test while movement patterns during landing was assessed using the LESS. The joint angles of the ankle, knee and hip joints during landing were analyzed using the 2D video analysis. After mean value of WBDF ROM was calculated, participants were divided into two groups (GDFROM and LDFROM) based on the mean value. The Mann-Whiteny 𝒰 test was used to identify differences in movement strategies during landing between two groups and the Pearson's correlation analysis was performed to determine relationships between WBDF ROM and movement strategies. Results: The LDFROM group showed the poorer LESS score and stiffer landing kinematics during landing compared to the GDFROM group (p<0.05). In addition, DFROM was significantly related to the LESS score and landing kinematics (p<0.05) except for total hip excursion (p=0.228). Conclusion: Our main findings showed that the LDFROM group had poorer landing quality and stiffer landing movements compared to the GDFROM group. In addition, increase of WBDF ROM significantly improved landing quality and soft-landing movements. To reduce shock during landing such as ground reaction forces, individuals need to better utilize WBDF ROM and lower extremity movements based on our findings. Therefore, intervention programs for safer landings should include exercises that increase WBDF ROM and utilize eccentric contraction.