• 제목/요약/키워드: Movable body

검색결과 49건 처리시간 0.027초

휴머노이드 로봇의 안정 보행 동작 해석에 관한 연구 (A Study of Stable Walking Analysis for Humanoid Robot)

  • 성유경;공정식;이보회;김진걸;허욱렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.404-407
    • /
    • 2003
  • In this paper, we have designed the humanoid robot's leg parts with 12 D.O.F. This robot uses ankle's joints to confirm stability of walking performance. It is less movable to use ankle's joints than to do upper body's balancing joints like IWR-III, which needs three parts of via points, support leg, swing leg and balancing joints. Instead, the proposed humanoid robot needs support leg and swing leg via points. ZMP(Zero Moment Point) is utilized to guarantee the stability of robot's walking. The humanoid robot uses the ankle's joints to compensate for IWR-III's balancing joints movement. Actually we concern about a motor performance when making a real humanoid robot. So a simulator is employed to know each joint torque of humanoid robot. This simulator needs D-H(Denavit-Hartenberg) parameters, robot's mass property and two parts of via points. The simulation results are robot's walking trajectories and each motor torque. Using the walking trajectories, we can see the robot's walking scene with 3D simulator. Before we develop the humanoid robot, simulation of the humanoid robot's walking performance is very helpful. And the torque data will be used to make humanoid's joint module.

  • PDF

조잡에 대한 형상의학적 고찰 (Review on Gastroenteric Troubles According to Neurosis or Uncomfortable Feeling with Hyungsang Medicine)

  • 강경화;박광길;이용태
    • 동의생리병리학회지
    • /
    • 제18권4호
    • /
    • pp.965-975
    • /
    • 2004
  • The writer reviewed on Chojop and came to conclusions as follows. Symptoms of Chojop is appeared digestive ailment such as belching, nausea, regurgitation of acid, stomachache etc., if being serious, felt oppressed with palpitating in chest and uneasiness at times. In Dangaesimbub written by Chujinhyung, the causes of Chojop were mainly regarded as phlegmatic fire(痰火) and suggested the way of treatment. The causes of Chojop are movable fire with phlegm, insufficiency of blood caused by thinking to excess, and Shinyanghohan(腎陽虛汗) that is piled cold phlegm by voidance and coldness of Renal Yang, but the main cause is brought to a conclusion as phlegmatic fire. The phlegmatic fire is come from being in discord with the spleen and the stomach, or from in harmony between vigor and blood according to essence and vital energy which are disturbed by combined feelings. That is caused by disharmony between inner and outer conditions according to individuals. The distinctive features in shapes of Chojop are revealed to shapes such as manlike woman, womanlike man, wearing darkish or reddish color between two eyebrows, being almond eyed, strong eyebrows, being sunk the upper part of the nose bridge, lots of facial blots, Dam-body, Ki type, Shin type, Birds group, and Yangmyung type. The doctors can prescribe Whadamchungwhatang to Yangmyung type, Yanghyulsamul-tang for patients with strong eyebrows so flourishing blood and vigor, Hyangsapyungwuisan for patients belong to Birds group, Soshikchungul-tang for Ki type, and Palmiwhan for man belonged to Bangkwang-body with voidance and coldness of Renal Yang chiefly.

Wave energy conversion utilizing vertical motion of water in the array of water chambers aligned in the direction of wave propagation

  • Hadano, Kesayoshi;Lee, Ki Yeol;Moon, Byung Young
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권3호
    • /
    • pp.239-245
    • /
    • 2017
  • As a new technical approach, wave energy converter by using vertical motion of water in the multiple water chambers were developed to realize actual wave power generation as eco-environmental renewable energy. And practical use of wave energy converter was actually to require the following conditions: (1) setting up of the relevant device and its application to wave power generation in case that severe wave loading is avoided; (2) workability in installation and maintenance operations; (3) high energy conversion potential; and (4) low cost. In this system, neither the wall(s) of the chambers nor the energy conversion device(s) are exposed to the impulsive load due to water wave. Also since this system is profitable when set along the jetty or along a long floating body, installation and maintenance are done without difficulty and the cost is reduced. In this paper, we describe the system which consists of a float, a shaft connected with another shaft, a rack and pinion arrangement, a ratchet mechanism, and rotary type generator(s). Then, we present the dynamics model for evaluating the output electric power, and the results of numerical calculation including the effect of the phase shift of up/down motion of the water in the array of water chambers aligned along the direction of wave propagation.

현대패션에 나타난 아시안룩의 비구조적 조형성 (Non-structural Characteristics of Asian Looks in Modern Fashion)

  • 임지아;김민자
    • 복식
    • /
    • 제60권6호
    • /
    • pp.1-10
    • /
    • 2010
  • The cultures and traditions of Asia has the roots so deep and it is the origin of inspiration. Therefore, it is easy to find a different inspiration when designing, expecially for Western designers who are seeking European tradition and its comparison. The most distinctive feature of the Asian look is non-structural and has no clear form close to the structure of the body or mathematical ratio, but is steric with 2-Dimensional planed textiles, and has a flexible, non-structural formative characteristic related to the movable body. This is base on the vision of the universe that regards the parts as the whole. From this research, generally studying about the Asian look and its non-structural formative characteristics. The study looked closely into the aesthetic value of non-structural formative characteristics formation, with basis on the large dress regulation system of the western reasoning and rationalism and mechanism. At first, my study pointed on the dressing functionalism or Neo-classism considering emotions, Anti-Western aspect observing surrealism dressing and expressionism dressing. Second, with men and women showing similar outer shape without the equivalent element such from wearing a corset, the sexism is abolished. Finally, the designers’ inner intention of art is being delivered, from the aspect that the expression of art, size and no waste of fabric shows effort of communicating with the world, giving value to the possibility of continuance.

슬관절내 유리체에 대한 초음파 검사의 유용성 (Usefulness of Ultrasound for the Loose Body in Knee)

  • 김정만;남호진;라기항;진성기;최승균
    • 대한정형외과 초음파학회지
    • /
    • 제3권1호
    • /
    • pp.8-14
    • /
    • 2010
  • 목적: 슬관절내에서 유리체가 만져지거나 방사선 소견상 보일 경우, 초음파의 임상적 유용성을 알아보고자 하였다. 대상 및 방법: 2007년 3월부터 2009년 7월까지 방사선 소견상 슬관절내에 유리체가 발견된 22명, 25예를 대상으로 하였으며, 남자가 8명, 여자가 14명, 우측이 11예, 좌측이 8예, 양측이 3예 였으며, 평균 연령은 56.3세(32~76세)였다. 유리체의 위치는 슬개상 주머니에서 13예, 슬개하 전방구획에서 1예, 슬관절 후방 구획에서 11예가 있었다. 슬개상 주머니에 있는 유리체의 경우 초음파를 종으로 슬개골 상부에 놓고 굴곡-신전 하면서 가동성을 관찰하였다. 슬개하 구획과 후방 구획에서는 초음파를 종과 횡으로 놓고 굴곡-신전을 하였을 때 유리체의 가동성을 관찰하였다. 결과: 슬개상 주머니의 유리체와 슬개하 유리체는 전 예에서 초음파 소견상 움직이는 것으로 진단 되어 제거술을 시행하였으며, 후방 구획에 있는 유리체는 전 예에서 움직이지 않는 것으로 진단되어 제거 대상에서 제외하였다. 결론: 슬관절 유리체의 가동성 유무로 수술적 제거의 필요성을 판단하는 데에 초음파는 임상적으로 도움을 줄 수 있었다.

  • PDF

PILOMATRICOMA 치험 1례 (A CASE OF PILOMATRICOMA)

  • 양희창;김수남;이동근;임창준;이창우;김은철
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제12권3호
    • /
    • pp.34-41
    • /
    • 1990
  • The pilomatricoma (calcifying epithelioma of Malherbe) is rare benign hard, spherical and freely movable cutaneous tumor, which was differentiated from hair cells, particulary hair cortex cells. It is usually occured as a single, asymptomatic, 0.5 cm to 3.0 cm sized, deep seated, firm nodule, covered by normal or pink skin. It arises chiefly in young people, including children, and most often in the head, neck and upper extrimites. The authers experienced a case of pilomatricoma which occured in preauricular region. This case was summarized as follows. 1. 10 years old female has suffered from hard subepidermal mass on preauricular area and she visited our out patient clinic. So we performed surgical extirpation and the excised specimen was pathologically examined. 2. Grossly the tumor measures 2.0 cm in diameter and firm, bosselated, spherical shaped which covered by a thin layer of fibrous tissue. On cut section, it shows spicular gritty surfaces, well encapsulation, interwoven and keratotic lamellae. 3. Histopathologically, the epithelial masses of the tumor are composed of two type of cells, basophilic cells and shodow cells. The basophilic cells resemble hair matrix cells which posses round or elogated, deeply basophilic nuclei and scanty cytoplasm. The shadow cells show a central, unstained shadow at the site of the lost nucleus. Gradual development of basophilic cells into shadow cells can be observed. Foci of calcification are present within the lobule of shadow cells. The stroma of the tumor shows a considerable foreign body giant cell reaction adjacent to the shadow cells. 4. No recurrence was observed until post-operative 40 months.

  • PDF

견관절의 회전중심점을 고려한 동작가능 영역의 생성 (Generation of a Practical Reach Envelope with the Center of Rotation of the Shoulder Joint Considered)

  • 정의승;이상규
    • 대한산업공학회지
    • /
    • 제25권1호
    • /
    • pp.56-66
    • /
    • 1999
  • Shoulder joint is the most movable joint in human body with, at least, three degrees of freedom, since there are at least three bones and five joints involved in shoulder movement. Due to the complexity of the shoulder joint and the lack of appropriate anatomical data, modeling of the shoulder joint has been known to be extremely difficult. In many biomechanical models being used, shoulder joint is considered as a fixed point and it is also assumed that the shoulder joint does not noticeably move during the shoulder movement. However, such an assumption is not valid in real applications and causes inaccuracy, especially, in the area of workspace evaluation. The reachable area generated by a human becomes somewhat different from that of current models for those models fail to appropriately reflect the movement of shoulder joint's center of rotation. In this study, the location of the shoulder joint's center of rotation was obtained in relation to the location of humerus, on which a new model for reach envelope generation was developed for workspace evaluation. From the experiments conducted for three subjects, the initial location of the center of rotation was determined for each subject and subsequent changes in the instantaneous center of rotation were drawn as a function of flexion and abduction of the shoulder. Based on the regression analysis, the study suggested a new method for the generation of reach envelope. Comparisons were also made among real reach envelopes obtained from the experiment, the ones from the model, and the ones from the new method suggested in the study. As a result, the prediction errors incurred from the new method were significantly reduced when compared to the ones from the current approach.

  • PDF

간접 충격을 이용한 압전 방식 진동형 에너지 하베스터 (Piezoelectric Vibration Energy Harvester Using Indirect Impact)

  • 주선아;지창현
    • 전기학회논문지
    • /
    • 제66권10호
    • /
    • pp.1499-1507
    • /
    • 2017
  • This paper presents an impact-based piezoelectric vibration energy harvester using a freely movable metal sphere and a piezoceramic fiber-based MFC (Macro Fiber Composite) as piezoelectric cantilever. The free motion of the metal sphere, which impacts both ends of the cavity in an aluminum housing, generates power across a cantilever-type MFC beam in response to low frequency vibration such as human-body-induced motion. Impacting force of the spherical proof mass is transformed into the vibration of the piezoelectric cantilever indirectly via the aluminum housing. A proof-of-concept energy harvesting device has been fabricated and tested. Effect of the indirect impact-based system has been tested and compared with the direct impact-based counterpart. Maximum peak-to-peak open circuit voltage of 39.8V and average power of $598.9{\mu}W$ have been obtained at 3g acceleration at 18Hz. Long-term reliability of the fabricated device has been verified by cyclic testing. For the improvement of output performance and reliability, various devices have been tested and compared. Using device fabricated with anodized aluminum housing, maximum peak-to-peak open-circuit voltage of 34.4V and average power of $372.8{\mu}W$ have been obtained at 3g excitation at 20Hz. In terms of reliability, housing with 0.5mm-thick steel plate and anodized aluminum gave improved results with reduced power reduction during initial phase of the cyclic testing.

경추 전방 잠금식 금속판이 장기적으로 경추에 미치는 영향 (Long-term Effects on the Cervical Spine after Anterior Locking Plate Fixation)

  • 김근수
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권4호
    • /
    • pp.493-500
    • /
    • 2001
  • Objective : Anterior cervical locking plates are the devices for achieving anterior cervical spinal fusion. This study was conducted to evaluate the locking plate system regarding its long-term advantages and disadvantages in the view of interbody fusion rate, hardware-related failures, vertebral change close to the fusion segment and postoperative complications. Method : Eight-six patients, operated from Jan., 1996 to Jun. 1998, were followed-up for more than two years. All of the cases were fused with iliac bone graft and ORION locking plate(Sofamor Danek USA, Inc., Memphis, TN) fixation. The patients were discharged or transferred to rehabilitation department 2-7 days after operation. A comprehensive evaluation of the interbody fusion state, instrument failure, vertebral change and postoperative complications were made by direct interview and cervical flexion-extension lateral plain films. Results : There were 55 male and 31 female with a mean age of 45 years(18-75 years). The mean follow-up period was 29 months(24-43 months). Various disorders that were operated were 40 cervical discs, 6 cervical stenosis including OPLL, 2 infections, and 38 traumas. Fusion level was single in 59 cases, two levels of each disc space in 15 cases, and two levels after one corpectomy in 12 cases. There was no instrument failure. Pseudoarthrosis was observed in two cases(2%) without radiological instability. The other patients(98%) showed complete cervical fusion with stable instrument. Mild settling of interbody graft with upward migration of screws was found in 12 cases(14%). Anterior bony growth at the upper segment was found in 5 cases(6%). Postoperative foreign body sensation or dysphagia was observed in 12 cases(4%), and disappeared within one month in 7 cases and within six months in 4 cases. One patient complained for more than six months and required reoperation to remove paraesophageal granulation tissue. Conclusion : The results show that Orion cervical locking plate has some disadvantages of upward migration of screws, anterior bony growth at the upper segment, or possibility of esophageal compression even though it has advantages of high interbody fusion rate or low instrument failure. Author believe that anterior cervical locking plate in the future should be thinner, and should have short end from the screw hole, and movable screw with adequate stability.

  • PDF

재가노인의 가정간호요구도 및 일상생활능력에 관한 연구 (A Study on Home Nursing Care Requirement and Activities of Daily Life Among the Elderly at Home)

  • 조선화;김병성;김공현;박형종
    • 보건교육건강증진학회지
    • /
    • 제11권2호
    • /
    • pp.125-145
    • /
    • 1994
  • The objectives of this study were to characterize the health status, the requirement of home nursing care, and dependency of daily life of the elderly so that the result could be used to provide basic data necessary for establishing home nursing care practices. The study subjects were 249 elders over 65 years old who resided at home in low income areas of three districts in Pusan. The field survey was conducted from December 27, 1993 through January 27, 1994, with a structured questionnaire. Statistical analysis was done by X²-test and Student's T-test using SPSS/PC/sup +/ program. The result were as follows; 1. Alcohol drinking rate was 50.0% for men and 27.7% for women, and cigarette smoking rate was 77.8% for men and 27.1% for women. 92.9% of elders aged 65-75 exercised regularly as compared to 81.9% of elders aged 75 and over(p<0.05). 2. 63.9% of male and 85.9% of female elders had chronic diseases showing singnificant differences(p<0.01), and both sexes had 1.7 kinds of chronic diseases in average; musculoskeletal diseases were the most common in 25.7%, while 6.8% of the elderly had cardiovascular diseases. 3. Partially movable elderly was 6.9% for men and 6.8% for woman, showing 47.1% of causes being cerebrovascular accidents. 4. The home nursing requirement was the highest for medication(66.3%), intramuscular injection(53.8%), and measurement of blood pressure·body·temperature·pulse rate(47.0%). 5. Among Physical Activities of Daily Life, bathing(10.4%) and movement(4.0%) showed high dependency rates, and among Instrumental Activities of Daily Life, phone calling(25.3%), shopping(24.5%), going out by bus(22.5%) showed high dependency rates. 6. For five categories of home nursing showing high requirements such as physical health examination, blood pressure·temperature·pulas rate measurements, medication, and intravascular injection, the requirements were different by age groups, education, and marital status(p<0.05).

  • PDF