• Title/Summary/Keyword: Mounting location

Search Result 57, Processing Time 0.021 seconds

Optimized Location Selection of Active Mounting System Applied to 1D Beam Structure

  • Kim, Byeongil
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.4_1
    • /
    • pp.505-511
    • /
    • 2022
  • The objective of this article is finding optimized locations of active mounts applied to 6-DOF beam structure with two active paths. When sinusoidal excitation forces are applied to the beam structure, secondary forces from two active mounts which can minimize (ideally becoming zero) transmitted forces are calculated mathematically and the vibration attenuation performance is validated through computer simulations. When the force applied to two active mounts are relatively low, those specific locations are considered as optimized location of active mounting system. As the location of mount changes, amplitude and phase of secondary forces in each path are analyzed with 3D plots. Based on the simulation results, a criterion for selecting mounting location is suggested and it would be very useful for selecting actuators for active mounts appropriately.

A Study on Simulation-based Mounting Location Selection of DIRCM for Multi-purpose Helicopter (다목적 헬기용 DIRCM의 시뮬레이션 기반 장착위치 선정 연구)

  • Lee, Myeong Seok;Shin, Baek Cheon;Hur, Jang Wook;Kim, Mi Jeong
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.15 no.1
    • /
    • pp.9-15
    • /
    • 2019
  • DIRCM is a device that deception missiles by directing the light source to missile seeker with infra-red laser based turret. The effectiveness of the device is affected by changes of the turret's Field of View (FoV), and also influence of the interference devices determines the effect of the DIRCM's effectiveness. Therefore finding mounting location for DIRCM is critical parameter for the DIRCM's effectiveness. so we applied stiffness review, interference analysis, FoV analysis and simulation analysis method to Multi-purpose helicopter for the find DIRCM location. As a result, in case of 1 DIRCM mounted at helicopters bottom shows 30~40% survivability. case of 2 DIRCM mounted at both side shows 70~80% survivability.

Aerodynamic Performance Dependency on the Geometric Shape and Mounting Location of OSRVM (OSRVM의 형상 및 장착 위치가 차량의 공력성능에 미치는 영향)

  • Han, Hyun Wook;Park, Hyun Ho;Kim, Moon Sang;Ha, Jong Paek;Kim, Yong Nyun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.3
    • /
    • pp.30-42
    • /
    • 2013
  • This study investigates the effects of OSRVM mounting location and its configurations such as stalk height and housing height on the aerodynamic performance of the passenger car. In order to validate the flow solver, FLUENT which is very well known commercial code, the flow field around an Ahmed Body was analyzed numerically and compared with the experimental data. The predicted aerodynamic performance and flow patterns around a car show good agreements with the experimental data. Mounting location and stalk height should be designed while OSRVM is mounted on the car to evaluate the aerodynamic performance precisely. Housing height, however, may be designed independent of the car because the aerodynamic interference between housing height and car configuration is negligible.

The effects of engine's misfiring condition on the dynamic behaviour of resilient mounting systems (엔진의 착화실패가 탄성지지계의 동적거동에 미치는 영향)

  • 손석훈;장민오;김성춘;김의간
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.188-193
    • /
    • 1996
  • The purpose of resilient mounting for marine engine is to prevent noise and ship damages caused by engine vibration. Although many researches for the resilient mounting system have been carried out, these results have limit to apply on the marine engine systems. Because marine engine generally have low speed operating range and have to consider misfiring condition. In this paper, we studied the effect of engine's misfiring on the resilient mounting systems. And the influences of design parameters, such as dynamic characteristics and location angles of resilient rubber mountings, were also examined on the single and double resilient mounting systems.

  • PDF

Peri-estrus activity and mounting behavior and its application to estrus detection in Hanwoo (Korea Native Cattle)

  • Si Nae Cheon;Geun-Woo Park;Kyu-Hyun Park;Jung Hwan Jeon
    • Journal of Animal Science and Technology
    • /
    • v.65 no.4
    • /
    • pp.748-758
    • /
    • 2023
  • This study was conducted to investigate the change in activity and mounting behavior in Hanwoo (Korean Native Cattle) during the peri-estrus period and its application to estrus detection. A total of 20 Hanwoo cows were fitted with a neck-collar accelerometer device, which measured the location and acceleration of cow movements and recorded the number of instances of mounting behavior by the altitude data. The data were analyzed in three periods (24-, 6-, and 2-h periods). Blood samples were collected for 5 days after the prostaglandin F2α (PGF2α) injection, and the concentrations of estradiol, progesterone, follicle-stimulating hormone, and luteinizing hormone were determined by enzyme-linked immunosorbent assays. Activity and mounting behavior recorded over 2-h periods significantly increased as estrus approached and were more efficient at detecting estrus than over 24- and 6-h periods (p < 0.05). Endocrine patterns did not differ with the variation of individual cows during the peri-estrus period (p > 0.05). Activity was selected as the best predictor through stepwise discriminant analysis. However, activity alone is not enough to detect estrus. We suggest that a combination of activity and mounting behavior may improve estrus detection efficiency in Hanwoo. Further research is necessary to validate the findings on a larger sample size.

Vibration Characteristic of a Cylindrical Rod according to the Mounting Locations on the Grid Support Structure (격자 지지구조체에 묶여있는 실린더 형 봉의 삽입위치에 따른 진동특성)

  • Lee, Kang-Hee;Yoon, Kyung-Ho;Song, Kee-Nam;Kim, Jae-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.515-518
    • /
    • 2006
  • A vibration test for a cylindrical rod inserted on the grid support structure was tested using the sine sweep excitation method with closed loop force control. The effect of the mounting location of a test rod on the vibration characteristics of a rod continuously supported by the full size($16{\times}16$) grid support was identified. An electromagnetic vibration shaker, non-contact displacement sensor and HP/VXI data acquisition device were used and TDAS software was also used as a data sampling and processing tools. The natural frequencies and mode shape of the test rod were consistent with the previous works of a rod vibration test with partial grids($3{\times}3,\;5{\times}5\;and\;7{\times}7$). The frequency characteristics of the rod according to the mounting location were shown clear discrepancies, but mode shapes were nearly same. As the test rod closes to the bottom clamping region of the spacer grid, peak vibration amplitudes of the rod become smaller.

  • PDF

Engine Mounting System Optimization for Improve NVH (NVH 향상을 위한 엔진 설치 시스템 최적화)

  • Kim, Jang-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.4665-4671
    • /
    • 2013
  • Engine mounting system is the most responsible system for NVH performance of vehicle. The vibration at idle shake, road shake, Key ON/OFF, gear shift tuned by the engine mount position and stiffness. Previously described Engine mounting system theory investigated and summarized in this paper. Decoupling of the Power train rigid mode and Reducing the angle between Torque-Roll-Axis and Elastic-roll-Axis is starting point of optimization. Multi-optimization analysis was performed because of variety simulation case and FE-model. Eventually, Find the best mount location and the stiffness has improved the performance of the vehicle NVH.

Optimization Algorithm of Gantry Route Problem for Odd-type Surface Mount Device (이형 부품 표면실장기에 대한 겐트리 경로 문제의 최적 알고리즘)

  • Jeong, Jaewook;Tae, Hyunchul
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.43 no.4
    • /
    • pp.67-75
    • /
    • 2020
  • This paper proposes a methodology for gantry route optimization in order to maximize the productivity of a odd-type surface mount device (SMD). A odd-type SMD is a machine that uses a gantry to mount electronic components on the placement point of a printed circuit board (PCB). The gantry needs a nozzle to move its electronic components. There is a suitability between the nozzle and the electronic component, and the mounting speed varies depending on the suitability. When it is difficult for the nozzle to adsorb electronic components, nozzle exchange is performed, and nozzle exchange takes a certain amount of time. The gantry route optimization problem is divided into the mounting order on PCB and the allocation of nozzles and electronic components to the gantry. Nozzle and electronic component allocation minimized the time incurred by nozzle exchange and nozzle-to-electronic component compatibility by using an mixed integer programming method. Sequence of mounting points on PCB minimizes travel time by using the branch-and-price method. Experimental data was made by randomly picking the location of the mounting point on a PCB of 800mm in width and 800mm in length. The number of mounting points is divided into 25, 50, 75, and 100, and experiments are conducted according to the number of types of electronic components, number of nozzle types, and suitability between nozzles and electronic components, respectively. Because the experimental data are random, the calculation time is not constant, but it is confirmed that the gantry route is found within a reasonable time.

Status of Loose Part Monitoring Technology and Facility in Domestic Nuclear Power Plant (국내 원전의 금속파편 감시기술 및 설비 현황)

  • Kim, Tae-Ryong;Lee, Jun-Shin;Sohn, Seok-Man
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.670-678
    • /
    • 2000
  • Loose parts monitoring system(LPMS) is one of the important monitoring systems for the safe and efficient operation of the nuclear reactor, since it is LPMS that can early detect loose parts which may cause a significant damage in facilities or components of the plant. Nuclear power plants in Korea have recently experienced several loose part alarms due to the metallic impact and it is expected that the frequency of the loose part will be increased along the aging of the plants. In this paper, the status of loose parts monitoring technologies and facilities in Korean nuclear power plants is presented for the establishment of LPMS installation plan in some nuclear reactors which are not yet equipped with LPMS. Sensor specification, location and mounting method for loose parts monitoring were reviewed. As a result, the location and the mounting method of the properly chosen sensor was recommended. Data acquisition algorithms and discriminating rules of loose part impact signals were also reviewed. Actual alarm cases occurred by true impact signal and false impact signal were stated here.

  • PDF