Tubular motor의 특성에 관한 연구 (A Study on the Analysis of the Characteristics of a tubular Moor-Trial Manufacure and the Characferistics in starting time-)

  • 임달호;이은웅;장석명
    • 전기의세계
    • /
    • 제28권3호
    • /
    • pp.72-77
    • /
    • 1979
  • The object of this paper is to try to develope Tulular Liner Induction Motor which consists of primary stator that generates traveling magnetic field from the three-phase winding of formed-wound concentric coil, and try to identify the characteristics of starting force. To indentify the theoretical starting force formular we have quoted the conventional Maxwell's basic equation and Poisson's equation which are used in the general machines thereby having obtained the formular of the current with in the conductor and of the air gap magnetic field respectively. General starting force formular is acquired by applying the formular of the current and magnetic field which was theoretically derived above. To this theoretically starting force formula various constants and the values of magnetic flux density resulting from the experimental motor are applied to present theoretically calculated values. Comparing these theoretically caculated values experimentally weighed values, we have proved the validity of theoretical research.

  • PDF

영구자석 기동장치가 회전자 돌극형 단상 SRM의 평균 토오크에 미치는 영향 (The Influence of The Starting Permanent Magnet on Average Torque of The Salient Pole Rotor Type Single Phase SRM)

  • 김준호;이은웅;이충원;서종민;김견묵
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1030-1032
    • /
    • 2003
  • Single phase SRM(switched reluctance motor) can not be start by itself because positive torque is generated in limited section. Therefore single phase SRM need starting device which is place the rotor in positive torque section when motor is begun to start. The prototype of salient pole rotor type single phase SRM, fabricated in previous research, has permanent magnet starting device. It is installed in bottom of the rotor for starting by itself. But, it is affected the motor when driving and cause the decrease of torque and speed. On this paper, average torque of the prototype was measured according to installation of the starting device or not. And influence of the staring device on average torque was confirmed by comparison of the results.

  • PDF

고압유도전동기용 기동리액터의 절연진단 (Insulation Analysis of Starting Reactor for High Voltage Induction Motors)

  • 이은춘;김태호;변일환;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.61-62
    • /
    • 2006
  • Since the starting reactor used for reducing inrush current of high voltage induction motor applies an electric current only when it is at the stage of transition, it gets lots of electrical or mechanical stress. In this aspect, the reliability on the starting reactor is very important because the reactor-relating-accident takes 80% of all the accident concerned with high voltage motor starting panel. In this study, we conducted an insulation test of starting reactor of high voltage induction motor of intake pumping station to the Seoul area And the result from this study was used as data for determining whether it's still usable or not.

  • PDF

Novel Soft Starting Algorithm of Single Phase Induction Motors by Using PWM Inverter

  • Kim, Hae-Jin;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1720-1728
    • /
    • 2018
  • This paper proposes a novel soft starting algorithm by using PWM inverter technique to control an amplitude of the motor starting current at a single-phase induction motor (SPIM). Traditional SPIM starting methods such as a Split-Phase, Capacitor-Start, Permanent-Split Capacitor (PSC), Capacitor-Start Capacitor-Run (CSCR), basically cannot control the magnitude of starting current due to the fixed system structures. Therefore, in this paper, a soft starting algorithm based on a proportional resonant (PR) control with a variable and constant frequency is proposed to reduce the inrush current and starting up time. In addition, a transition algorithm for operation modes is devised to generate a constant voltage and constant frequency (CVCF). The validity and effectiveness of the proposed soft starting method and transition algorithm are verified through experimental results.

가변속 터보냉동기의 기동특성에 관한 연구 (A Study on the Starting Characteristic of Variable Speed Centrifugal Chiller)

  • 김희선;윤홍민;나승호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.512-513
    • /
    • 2012
  • The electric motor is essential to drive turbo machinery. In order to overcome the speed limitations of general motors, the inverter is used to perform high speed to tens of rpm. The high speed drives are widely used in many applications such as turbo blower, turbo centrifugal compressors, and pump using air bearing technique. Starting of high speed motor can cause step out, stall, oscillation of motor because the phase inductance is much smaller than that of ordinary motor. This paper studied on the starting characteristic of variable speed centrifugal chiller considering high speed motor characteristics. Finally, the superiority of the inverter is verified by experimental results.

  • PDF

직립 기동 영구자석 동기전동기의 기동토크 최적화 설계 (Optimal Design for Starting -Torque of Line-Start Permanent Magnet Synchronous Motors)

  • 김병국;문지우;김미정;이병준;조윤현
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1390-1396
    • /
    • 2007
  • The line-start permanent magnet synchronous motor has a high efficiency and an advantage in constant speed operation regardless of the effect of load variation. However, it is difficult to predict the performance of characteristics accurately, because of the unbalanced starting torque with the initial starting position of the rotor and the generation of a break torque. In this paper the dynamic characteristics of the line-start permanent magnet synchronous motor are described and compared with those of the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bars in the line-start permanent magnet synchronous motor. Finally this paper gives the comparison between the simulation results and the experimental results.

직립 기동 영구자석 동기 전동기의 기동 토크 최적화 설계 (Optimal Design for Starting-Torque of Line Start Permanent Magnet Synchronous Motor)

  • 김병국;황동원;김태현;조원영;이인재;한성진;조윤현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.930-932
    • /
    • 2005
  • The line-start permanent magnet synchronous motor has a high efficiency and an advantage in constant speed operation regardless of the effect of load variation. However it is difficult to predict the performance of characteristics accurately, because of the unbalanced starting torque with the initial starting position of the rotor and the generation of a break torque. In this paper the dynamic characteristics of the line-start permanent magnet synchronous motor are described and compared with those of the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bars in the line-start permanent magnet synchronous motor.

  • PDF

Analysis of Slot Leakage Reactance of Submersible Motor with Closed Slots during Starting Transient Operation

  • Bao, Xiaohua;Di, Chong;Fang, Yong
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.135-142
    • /
    • 2016
  • Generally, closed slots are adopted to reduce the water friction loss in both the stator and the rotor of water filling submersible motor due to the special environment of operation. One of the obvious differences between the traditional induction motors and water filling submersible motors is that the submersible motors only need relatively smaller starting torque. This paper aims to analyze the slot leakage reactance of water filling submersible motor during starting transient operation. An improved analytical method which considered the magnetic saturation of the slot bridge and the skin effect of rotor bars is proposed. The slot permeance factor which has a direct impact on the slot leakage reactance is calculated. Then finite element models with different stator slot types are constructed and search coils are introduced to measure the slot flux linkage. Moreover, the starting performances of the models with two typical stator slots are compared and the flux leakage characteristics are obtained. Finally, the results obtained by finite element method are very close to the results obtained by analytical method.

SIMULATION OF STARTING PROCESS OF DIESEL ENGINE UNDER COLD CONDITIONS

  • Park, J.K.
    • International Journal of Automotive Technology
    • /
    • 제8권3호
    • /
    • pp.289-298
    • /
    • 2007
  • A nonlinear dynamic simulation model from cranking to idle speed is developed to optimize the cold start process of a diesel engine. Physically-based first order nonlinear differential equations and some algebraic equations describing engine dynamics and starter motor dynamics are used to model the performance of cold starting process which is very complex and involves many components including the cold start aiding method. These equations are solved using numerical schemes to describe the starting process of a diesel engine and to study the effects of cold starting parameters. The validity of this model is examined by a cold start test at $-20^{\circ}C$. Using the developed model the effects of the important starting variables on the cold starting processes were investigated. This model can be served as a tool for designing computer aided control systems that improve cold start performance.

소수력 발전소에 적용하는 유도발전기의 동작 특성 (A Study on the Operation Characteristic of Induction Generator in the Small Hydropower Plant)

  • 김영국;김종겸
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.632-638
    • /
    • 2013
  • In this study, we described voltage fluctuation characteristics of distribution line during starting and normal operation condition of the small hydro generators. Based on these theories, we scrutinized the starting and operating characteristics of induction generators installed in two small hydro power plants that is connected to the distribution line and researched necessary factors when selecting the generator type. The type of turbines and capacity of generators are different. One is below 1,000kW and the other is above 1,000kW. Two generators are tested during starting, and it acts as motor not generator at the instant that the machine is connected to the grid. After connecting to the grid, the machine rotates above synchronous speed before converting to the generator mode. Therefore the characteristic of the generator during starting is same as it of motor.