• 제목/요약/키워드: Motor drive inverter

검색결과 538건 처리시간 0.028초

Analysis of Cascaded H-Bridge Multilevel Inverter in DTC-SVM Induction Motor Drive for FCEV

  • Gholinezhad, Javad;Noroozian, Reza
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.304-315
    • /
    • 2013
  • In this paper, analysis of cascaded H-bridge multilevel inverter in DTC-SVM (Direct Torque Control-Space Vector Modulation) based induction motor drive for FCEV (Fuel Cell Electric Vehicle) is presented. Cascaded H-bridge multilevel inverter uses multiple series units of H-bridge power cells to achieve medium-voltage operation and low harmonic distortion. In FCEV, a fuel cell stack is used as the major source of electric power moreover the battery and/or ultra-capacitor is used to assist the fuel cell. These sources are suitable for utilizing in cascaded H-bridge multilevel inverter. The drive control strategy is based on DTC-SVM technique. In this scheme, first, stator voltage vector is calculated and then realized by SVM method. Contribution of multilevel inverter to the DTC-SVM scheme is led to achieve high performance motor drive. Simulations are carried out in Matlab-Simulink. Five-level and nine-level inverters are applied in 3hp FCEV induction motor drive for analysis the multilevel inverter. Each H-bridge is implemented using one fuel cell and battery. Good dynamic control and low ripple in the torque and the flux as well as distortion decrease in voltage and current profiles, demonstrate the great performance of multilevel inverter in DTC-SVM induction motor drive for vehicle application.

대전력 교류전동기 구동용 소프트 스위칭 인버터의 EMI 해석 (EMI Analysis of Soft Switching Inverter on High Power AC Motor Drive)

  • 권순걸
    • 융합신호처리학회논문지
    • /
    • 제3권3호
    • /
    • pp.76-81
    • /
    • 2002
  • 대전력 전동기 구동장시스템에서 하드 스위칭 토폴로지는 심각한 스위칭 손실과 EMI잡음문제를 일으키며, 인버터 스위칭 주파수는 과도한 손실과 열적문제 때문에 제한되게 된다. 본 연구의 목적은 개선된 소프트 스위칭 토폴로지에 의해 스위칭손실과 EMI를 저감할 수 있는 대용량 교류전동기의 구동에 적합한 시스템을 개발하고자하며, 시뮬레이션과 실험을 통하여 그 타당성을 입증하였다.

  • PDF

Output filter design for conducted EMI reduction of PWM Inverter-fed Induction Motor System

  • Kim Lee-Hun;Won Chung-Yuen;Kim Young-Seok;Choi Se-Wan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.761-767
    • /
    • 2001
  • In this paper, filtering techniques to reduce the adverse effects of motor leads on high-frequency PWM inverter fed AC motor drives will be examined. The filter was designed to keep the motor terminal from the cable surge impedance to reduce overvoltage reflections, ringing, and the dv/dt, di/dt. Therefore, filtering techniques are investigated to reduce the motor terminal overvoltage, ringing, and EMI noise in inverter fed ac motor drive systems. The output filter is used to limit the rate of the inverter output voltage and reduce EMI(common mode noise) to the motor. The performance of the output filter is evaluated through simulations (PSIM) and experiment on PWM inverter-fed ac motor drive(3phase, 3hp(2.2kw), input voltage 220/380V, induction motor). An experimental PWM drive system reduction of conducted EMI was implemented on an available TMS320C31 microprocessor control board. Finally, experimental results showed that the inverter output filter reduces more CM noise than the LPF(low pass filter) and reduce overvoltage and ringing at the motor terminal.

  • PDF

하이브리드 자동차용 모터 및 인버터 최신 동향 분석 (Recent Progress Trend in Motor and Inverter for Hybrid Vehicle)

  • 김성진;홍승민;남광희
    • 전력전자학회논문지
    • /
    • 제21권5호
    • /
    • pp.381-387
    • /
    • 2016
  • Many efforts have focused on the improvement of power density and efficiency by downsizing the motor and inverter. Recently, Toyota, Honda, and GM realized that the compact-sized motor uses the hairpin structure with increased space factor. Reducing the maximum torque from high-speed technique also makes it possible to design the high-power density model. Toyota and Honda used the newly developed power semiconductor IGBT to decrease conduction loss for high-efficiency inverter. In particular, Toyota used the boost converter to increase the DC link voltage for high efficiency in low-torque high-speed region. Toyota and GM also used the double-sided cooling structure for miniaturization of inverter for high-power density.

PWM 인버터 시스템에서의 전도노이즈 저감을 위한 출력필터 설계에 관한 연구 (Output Filter Design for Conducted EMI Reduction of PWM Inverter-Fed AC Motor Drive System)

  • 김이훈;박규현;원충연;김영석;최세완
    • 전력전자학회논문지
    • /
    • 제6권6호
    • /
    • pp.546-555
    • /
    • 2001
  • 본 논문에서는 PWM 인버터-유도전동기 구동시스템의 전도노이즈 저감을 위한 출력필터 설계에 관한 연구를 수행하였다. 전도노이즈는 고전압 입력, 고용량 구동시스템 그리고 긴 전동기 터미널 등의경우에서 크게 문제가 된다. 고압력을 갖는 시스템에서는 높은 압력에 비례한 직류 링크 전압을 갖고 이에 따라 스위칭 dv/dt가 순간 최대 CM 접지전류를 발생시킨다. 그러므로 이에 대한 대책이 필요하다. 따라서 최근 산업 현장에서 많이 사용되고 있는 PWM 인버터를 설계 제작하여 유도전동기를 구동하고 이에 따라 발생되는 전도노이즈 성분을 감쇠 시킬 수 있는 출력필터를 설계하였고 제작 및 실험을 통하여 그 타당성을 입증하였다.

  • PDF

단일 인버터를 이용한 표면 부착형 영구자석 동기 전동기 병렬 구동 시스템의 센서리스 구동 방법 (Sensorless Drive for Mono Inverter Dual Parallel Surface Mounted Permanent Magnet Synchronous Motor Drive System)

  • 이용재;하정익
    • 전력전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.38-44
    • /
    • 2015
  • This paper presents the sensorless drive method for mono inverter dual parallel (MIDP) surface mounted permanent magnet synchronous motor (SPMSM) drive system. MIDP motor drive system is a technique that can reduce the cost of the multi motor driving system. To maximize this merit of the MIDP motor drive system, the sensorless technique is essential to eliminate the position sensors. This paper adopts an appropriate sensorless method for MIDP SPMSM drive system, which uses the reduced order observer and phase locked loop (PLL) to reduce the calculation burden. The I-F control method is implemented for start-up and low speed operation. The validity and performance of the proposed algorithm are shown via experiments with 600-W SPMSMs.

견인전동기 가변속 운전을 위한 인버터의 PWM 방법 및 패턴 절환기법에 관한 연구 (A Study on the PWM Strategy and Gear Changing Techniques of an Inverter for Variable Speed Drives on Traction Motors)

  • 서영민;박영진;홍순찬
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권11호
    • /
    • pp.646-654
    • /
    • 1999
  • This paper deals with PWM patterns for harmonic reduction in inverter fed traction motors and the gear changing techniques for the variable speed drive of traction motor. GTOs are used as switching device of inverter because traction motor is a large load. To derive PWM rattern which can minimize the harmonics with the limited switching frequency, the output current and torque characteristic of SPWM and SHE PWM was analyzed. GTO inverter used for traction motor drive includes harmonics in the output current and torque by the limitation of switching frequency. However, the hybrid PWM method that adopt SPWM in the range of low frequency and SHE PWM in upper frequency range can achieve less harmonic characteristics in GTO inverters. If the traction motor is driven in variable speed by the proposed PWM pattern, 7 times of gear changing is needed. At the instant of the mode change, magnetic flux and torque may be altered and the large current flow. To reduce such an undesirable transient behavior, it is also presented the technique for the gear changing of inverter fed traction motor drive operated with the hybrid PWM. The results are verified by simulations and experiments.

  • PDF

Soft Switching Inverter with An Auxiliary Active Quasi-Resonant DC Link Snubber for AC Servo Motor Drive

  • Mun, Sang-Pil;Kim, Chil-Ryong;Lee, Jong-Kurl;Park, Man-Kyu;Kwon, Soon-Kurl
    • 조명전기설비학회논문지
    • /
    • 제22권3호
    • /
    • pp.79-87
    • /
    • 2008
  • This paper presents a simple circuit topology of the auxiliary active quasi-resonant DC link snubber-assisted three phase voltage source soft-switching inverter for small scale PM motor drive applications. The pulse processing drive circuit interface and its soft-switching operation are discussed from an experimental point of view. Moreover, its conductive noise is measured and evaluated for electrical AC servo motor drive as compared with that of the conventional hard switching inverter.

인버터 모터 드라이브 시스템을 위한 새로운 1200V High Side Driver (Advanced 1200V High Side Driver for Inverter Motor Drive System)

  • 송기남;오원희;최진규;이은영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.487-488
    • /
    • 2015
  • New inverter motor drive systems consume 30%~50% less energy compared to existing motor drive systems. For inverter motor drive systems, the development of a 1200V high side driver is critical. This paper presents an advanced 1200V high side driver with low power consumption and high ruggedness. This solution implements a high voltage level shifter which consumes low power by adding a clamped VGS LDMOS driver to the conventional short pulse generator. Moreover, this paper proposes a highly rugged 1200V LDMOS which improves SOA by limiting the hole current. This paper could be applied to smart power modules used for HVAC (heating, ventilation, and airconditioning) and industrial inverters. Consequently, this paper will provide design engineers with an understanding of how they can make a significant contribution to worldwide energy savings.

  • PDF

Five-level Inverter for Excitation Control of SRM Drive

  • Oh, Seok-Gyu;Park, Sung-Jun;Ahn, Jin-Woo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권3호
    • /
    • pp.64-69
    • /
    • 2001
  • Energy recovery in the regenerative region is very important when SRM is used in traction drive, This is to reduce en-ergy loss during mechanical braking and/or to have a high efficiency drive during braking To control excitation voltage in motor operation and regenerative voltage in the generator operation in the SRM multi-level voltage control is effective The paper sug-gests multi-level inverter which is useful for motoring and regenerative operation in SRM