• Title/Summary/Keyword: Motor Fan

Search Result 252, Processing Time 0.026 seconds

Optimal Nozzle Design of Bladeless Fan Using Design of Experiments (실험계획법을 이용한 날개 없는 선풍기의 노즐 형상 최적 설계)

  • Jeong, Siyoung;Lee, Jongsoo;Yoon, Jaehyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.8
    • /
    • pp.711-719
    • /
    • 2017
  • Bladeless fan is becoming increasingly popular owing to its advantages, such as improved safety, easy to clean, and attractive shape. However, many people are reluctant to purchase it because of several disadvantages, such as noise and moderate wind; therefore, research on how improve wind generation without increasing the motor speed is required. This study investigates the optimization of the shape of the nozzle and nearby surface using CFD (Computational Fluid Dynamics) simulation, ANSYS fluent. The results are analyzed by ANOM (analysis of mean) and interaction analysis; therefore this study suggests the variables of affecting Coanda effect and satisfy the govern equation, the conservation of momentum. The optimal combination was found through a predictive equation. In this study, factors and levels that affect the mass flow rate were selected and experimental points were arranged using the orthogonal array table. The value of the mass flow rate was confirmed by ANSYS fluent, which is a CFD program. Through the ANOM, it was confirmed that the nozzle distance is the most influential parameter affecting the mass flow rate. Furthermore, the mass flow rate obtained from the predictive equation and the mass flow rate from the CFD correspond to the largest values. Results from this study confirmed that the mass flow rate is increased by a change in the shape, even if the motor speed did not increase.

Implementation of the Digital Current Control System for an Induction Motor Using FPGA (FPGA를 이용한 유도 전동기의 디지털 전류 제어 시스템 구현)

  • Yang, Oh
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.11
    • /
    • pp.21-30
    • /
    • 1998
  • In this paper, a digital current control system using a FPGA(Field Programmable Gate Array) was implemented, and the system was applied to an induction motor widely used as an industrial driving machine. The FPGA designed by VHDL(VHSIC Hardware Description Language) consists of a PWM(Pulse Width Modulation) generation block, a PWM protection block, a speed measuring block, a watch dog timer block, an interrupt control block, a decoder logic block, a wait control block and digital input and output blocks respectively. Dedicated clock inputs on the FPGA were used for high-speed execution, and an up-down counter and a latch block were designed in parallel, in order that the triangle wave could be operated at 40 MHz clock. When triangle wave is compared with many registers respectively, gate delay occurs from excessive fan-outs. To reduce the delay, two triangle wave registers were implemented in parallel. Amplitude and frequency of the triangle wave, and dead time of PWM could be changed by software. This FPGA was synthesized by pASIC 2SpDE and Synplify-Lite synthesis tool of Quick Logic company. The final simulation for worst cases was successfully performed under a Verilog HDL simulation environment. And the FPGA programmed for an 84 pin PLCC package was applied to digital current control system for 3-phase induction motor. The digital current control system of the 3 phase induction motor was configured using the DSP(TMS320C31-40 MHz), FPGA, A/D converter and Hall CT etc., and experimental results showed the effectiveness of the digital current control system.

  • PDF

Improving Fuel Efficiency of a Hybrid Excavator (하이브리드 굴삭기 연비 개선 연구)

  • Cho, Sungwoo;Yoo, Seungjin;Park, Cheol-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.2
    • /
    • pp.211-217
    • /
    • 2015
  • Emission gas regulations and constantly increasing fuel costs call for the worldwide use of environmentally friendly and energy-efficient machines in industry. To meet these requirements, a hybrid excavator prototype has been developed that incorporates an electric swing motor, engine assist motor, and ultra-capacitor module into a conventional hydraulic excavator of the 22-ton class. This paper mainly describes a few techniques to optimize its energy efficiency. These include 1) controlling the engine speed in proportion to the load torque, 2) controlling the pump displacement when driving the electric swing system, 3) managing the ultra-capacitor voltage to minimize the electrical energy loss, and 4) reducing the cooling fan speed to improve the energy efficiency of the system.

Compensation of Periodic Magnetic Saturation Effects for the High-Speed Sensorless Control of PMSM Driven by Inverter Output Power Control-based PFC Strategy

  • Lee, Kwang-Woon
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1264-1273
    • /
    • 2015
  • An inverter output power control based power factor correction (PFC) strategy is being extensively used for permanent magnet synchronous motor (PMSM) drives in appliances because such a strategy can considerably reduce the cost and size of the inverter. In this strategy, PFC circuits are removed and large electrolytic DC-link capacitors are replaced with small film capacitors. In this application, the PMSM d-q axes currents are controlled to produce ripples, the frequency of which is twice that of the AC main voltage, to obtain a high power factor at the AC mains. This process indicates that the PMSM operates under periodic magnetic saturation conditions. This paper proposes a back electromotive-force (back-EMF) estimator for the high-speed sensorless control of PMSM operating under periodic magnetic saturation conditions. The transfer function of the back-EMF estimator is analyzed to examine the effect of the periodic magnetic saturation on the accuracy of the estimated rotor position. A simple compensation method for the estimated position errors caused by the periodic magnetic saturation is also proposed in this paper. The effectiveness of the proposed method is experimentally verified with the use of a PMSM drive for a vacuum cleaner centrifugal fan, wherein the maximum operating speed reaches 30,000 rpm.

A Study on the Fire Risk Assessment of Combustible Exhaust Duct-fume (가연성 배기덕트-흄 화재위험성 평가에 관한 연구)

  • Yoon, Yeo-Song;Lee, Young-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.1
    • /
    • pp.32-37
    • /
    • 2010
  • When back-out & firing Process applies heat, hume is piled up in exhaust duct by organic compound and it have high dangerousness. There by, the process is happening a lot of damage that is exhaust duct fire. However we do not have certain fire dangerousness estimation and digestion countermeasure. So we need preventive measure. Back-out & firing is a process which has fine structure, electrical and mechanical characteristics, such as firing kiln and back-out kiln which has pipe line and box type. The box oven is made of heating coil, fan motor and control panel. Back-out & firing process has air circulation institution of quick ventilation type. When we operate this process for long time, fire can break out easily. Duct is made by zinc shredder. If fire breaks out in duct inside, fire by deposit fume can be dispersed easily. Accordinglym, This project estimate danger for back-out & firing process exhaust duct through real fire test. And there is purpose of study to establish preventive measure.

Accelerated Life Test for Door Switch of Refrigerator (냉장고 도어스위치의 가속수명시험)

  • Ryu Dong Su;Kim Sang Uk;Jang Young Kee;Moon Chul Hui
    • Journal of Applied Reliability
    • /
    • v.5 no.2
    • /
    • pp.273-287
    • /
    • 2005
  • Accelerated life test models and procedure are developed to assess the reliability of Refrigerator door switch. The main function of door switch is to operate bulb lamp and fan motor in the refrigerating room. The accelerated life test method and test equipments are developed using the relationship between stresses and life characteristics of the products. Using the developed accelerated life test method, the parameters of the ALT model and life time distribution are estimated and the reliability of the Door S/W at use condition if assessed. The proposed accelerated life test method and procedure may be extended and applied to testing similar kinds of products to reduce test time and costs of the tests remarkably.

  • PDF

Inverter Motor Drive System Development for High Static Pressure Ventilation Fan (고정압용 프리미엄 환풍기를 위한 인버터형 모터 드라이브 시스템 개발)

  • Cha, Hyun-Rok;Lee, Sung-Ho;Kim, Kyung-Su;Lee, Kyu-Seok;Jun, Seong-Kyu;Song, Doo-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1193-1194
    • /
    • 2008
  • 본 논문은 주거환경 변화 및 공기 중 부유물질로 인한 피해를 보호하기 위해 제정된 공기질 관리법안에 적합한 대기 환경 조건을 구현하기 위한 고정압 환풍기용 모터 및 제어 알고리즘에 관한 논문이다. 외기에 압력이 변화하는 외란에도 일정한 풍량을 낼 수 있도록 하기 위해서 속도와 전류의 두 물리량을 곱의 형태로 취하여 profile을 만들고 이에 추종하는 방식을 본 논문에서 제안하였다. 제품의 상용화를 위해서 풍량센서가 없는 센서리스 방식을 구현하기 위해서 전류 값을 토대로 압력 변화량을 일정하게 제어하는 방식을 취하였다. 고정압제어를 위해서 Open-loop상태에서 모터의 P-Q(압력-풍량)data를 측정하고 이를 기초로 예상 구동 영역을 유추하고 이를 토대로 Profile을 만들고 이 Profile을 추종하는 제어를 통해서 고정압제어를 실현하였다. Reference로 속도를 기준으로 하였으며, 동일 속도에서 전류의 값을 비교하여 제어하고자 하는 전류 값이 되도록 함으로써 정압을 실현하였다.

  • PDF

Conceptual Design Study of a Low-Speed Wind Tunnel for Performance Test of Wind Turbine (풍력터빈 성능시험을 위한 풍동 개념연구)

  • Kang, Seung-Hee;Choi, Woo-Ram;Kim, Hae-Jeong;Kim, Yong-Hwi
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.431-434
    • /
    • 2009
  • Conceptual study of an open-circuit type low-speed wind tunnel for test of wind turbine blade is conducted. The tunnel is constituted of a settling chamber, a contraction, closed and open test sections, a diffuser, two corners, a cross leg and a fan and motor. For the performance test, the closed test section width of 1.8 m, height of 1.8 m and length of 5.25 m is selected. The open test section with dimension width of 1.8 m, height of 1.8 m and length of 4.14 m is adopted for aeroacoustic test. The contraction ratio is 9 to 1 and maximum speed in the closed test section is 67 m/sec. Input power in the tunnel is about 238 kW and its energy ratio is 3.6. The wind tunnel designed in present study will be an effective tool in research and development of wind turbine.

  • PDF

The Study about the Performance-Analysis of a Automotive Engine Cooling System (엔진 냉각시스템 성능해석에 관한 연구)

  • Shin, Chang-Hoon;Lee, Seung-Hee;Park, Warn-Gyu;Jang, Gi-Lyong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.2
    • /
    • pp.39-48
    • /
    • 2006
  • An engine cooling system affects overall performances of an engine which has been recently requested higher power in more confined engine room. The design of efficient cooling system demands a great effort to effectively correlate with each components, such as water jacket, radiator, coolant pump, cooling fan, etc. Thus, the aim of this study is to provide the design tool of the cooling system in the early design stage by enabling for the designer to accurately predict the engine cooling performances. This user-friendly design tool has various ways to assemble each components and control the running condition with related database. The present design tool was simulated and compared with experimental data. As a result, the inlet and outlet temperature of the radiator agree very well with experiments. It was concluded that the present design tool could be effectively used for the design of the engine cooling system.

A STUDY ON THE EXPLOSION SAFETY ASSESSMENT OF HYDROCARBON REFRIGERANT REFRIGERATOR

  • Oh, Kyu-Hyung;Kim, Min-Kyu;Chu, Euy-Sung;Lim, Byung-Han;Kim, Man-Hoe;Park, Yoon-Ser
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.289-296
    • /
    • 1997
  • This paper discribes an experimental explosion risk assessment study on refrigerators containing flammable hydrocarbon refrigerant. A refrigerator used in this study is a larder fridge type, 215 liter in volume. The hydrocarbon refrigerant used in the refrigerator is iso-butane(C$_4$H$_{10}$). For the explosion safety assessment of the refrigerator, temperature of compressor, cooling air circulation fan motor, defrost heater and inner lamp were measured during the operation. And to confirm the ignitablity of flammable gas by the electric spark of the switches of the refrigerator, ON-OFF test of all switches were conducted with compulsorily near the stoichiometric concentration atmosphere of iso-butane-air mixture. As the result of experiment above mentioned and another experiment for the explosion safety assessment, we can conclude that explosion hazard in connection with the use of hydrocarbon refrigerant was few.w.

  • PDF