• Title/Summary/Keyword: Motion study

Search Result 9,802, Processing Time 0.053 seconds

A Control Method for designing Object Interactions in 3D Game (3차원 게임에서 객체들의 상호 작용을 디자인하기 위한 제어 기법)

  • 김기현;김상욱
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.9 no.3
    • /
    • pp.322-331
    • /
    • 2003
  • As the complexity of a 3D game is increased by various factors of the game scenario, it has a problem for controlling the interrelation of the game objects. Therefore, a game system has a necessity of the coordination of the responses of the game objects. Also, it is necessary to control the behaviors of animations of the game objects in terms of the game scenario. To produce realistic game simulations, a system has to include a structure for designing the interactions among the game objects. This paper presents a method that designs the dynamic control mechanism for the interaction of the game objects in the game scenario. For the method, we suggest a game agent system as a framework that is based on intelligent agents who can make decisions using specific rules. Game agent systems are used in order to manage environment data, to simulate the game objects, to control interactions among game objects, and to support visual authoring interface that ran define a various interrelations of the game objects. These techniques can process the autonomy level of the game objects and the associated collision avoidance method, etc. Also, it is possible to make the coherent decision-making ability of the game objects about a change of the scene. In this paper, the rule-based behavior control was designed to guide the simulation of the game objects. The rules are pre-defined by the user using visual interface for designing their interaction. The Agent State Decision Network, which is composed of the visual elements, is able to pass the information and infers the current state of the game objects. All of such methods can monitor and check a variation of motion state between game objects in real time. Finally, we present a validation of the control method together with a simple case-study example. In this paper, we design and implement the supervised classification systems for high resolution satellite images. The systems support various interfaces and statistical data of training samples so that we can select the most effective training data. In addition, the efficient extension of new classification algorithms and satellite image formats are applied easily through the modularized systems. The classifiers are considered the characteristics of spectral bands from the selected training data. They provide various supervised classification algorithms which include Parallelepiped, Minimum distance, Mahalanobis distance, Maximum likelihood and Fuzzy theory. We used IKONOS images for the input and verified the systems for the classification of high resolution satellite images.

Ultrasound-Guided Local Steroid Injection Therapy for Acute Calcific Tendinitis of Shoulder (초음파를 이용한 급성 극상근 석회화 건염의 스테로이드 국소 주사 요법)

  • Kim, Jung-Man;Nam, Ho-Jin;Ra, Ki-Hang;Kang, Min-Ku
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.85-89
    • /
    • 2009
  • Purpose: To analyze the clinical outcome after ultrasound guided multiple dry needlings and local steroid injection for acute calcific tendinitis of shoulder. Materials and Methods: Twenty patients with acute episode of pain by calcific tendinitis of shoulder with average age 58.2 (50~70 years) and follow-up of 18 months in average (range, 12~24) were included in study. There were 18 patients with right and 2 with left sided involvement. All patients had calcific deposits in the supraspinatus tendon. All patients underwent standardized nonoperative treatment protocol, consisting of 5~12 MHz high resolution ultrasound guided multiple dry needlings with 18 guage needle, followed by 2% lidocaine 1cc and 40 mg/ml depomedrol 1cc injection at site of calcific tendinitis. The outcome was assessed by UCLA shoulder score, range of motion and VAS score. A statistical analysis with ANOVA and Tukey's post-hoc test with the significance level at 5% was performed using SAS 9.1 software (SAS Institute, Cary, NC). Results: All patients got continuous relief of pain right after the procedures until final follow-up. Before the procedures, the UCLA scores were fair in 15 patients and poor in 5. After the procedures, the UCLA scores were excellent in 16 patients and good in 4. All cases revealed no limitation of shoulder function. The average VAS score decreased from 8.9 before the procedures to 0.5 at final follow-up (p<0.0001). No complication was encountered. Conclusion: An ultrasound guided local steroid injections following multiple dry needlings would be one of the useful treatment modality for the acute calcific tendinitis of shoulder.

  • PDF

The Follow-up Results of Anterior Cruciate Ligament Reconstruction Using The Flexible Reamer (유연성 연마기를 이용한 관절경적 전방 십자 인대 재건술의 추시 결과)

  • Chae, In-Jung;Wang, Joon-Ho;Choi, Gi-Won;Song, Dong-Ik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.18-23
    • /
    • 2008
  • Purpose: The purpose of this study is to evaluate the clinical results of the function and stability of ACL reconstruction using the flexible reamer. Materials and Methods: We reviewed 98 patients who taken ACL reconstruction using the flexible reamer from March, 1999 to May, 2004. And the follow-up period was more than 12 months in all cases. We used the subjective tests including Lysholm knee score and 2000 International Knee Documentation Committee(IKDC) subjective knee score, and the objective tests such as anterior drawer test, Lachman test, pivot shift test, and KT-2000 arthrometer to evaluate the clinical results. Results: In the range of motion of the affected knee, the extension deficit more than 5 degree was 8 cases preoperatively and 1 case postoperatively. The flexion deficit more than 5 degree was 12 cases preoperatively and 2 cases postoperatively. The mean Lysholm knee score was 61.3 point(${\pm}3.5$ SD) preoperatively and 87.7 point(${\pm}2.0$ SD) postoperatively. The mean 2000 International Knee Documentation Committee(IKDC) subjective knee score was 49 point(${\pm}3.3$ SD) preoperatively and 84 point (${\pm}2.2$ SD) postoperatively. 93 cases were more than grade II in Lachman test preoperatively and 5 cases postoperatively. 71 cases were more than grade II in pivot shift test preoperatively but 89 cases were negative postoperatively. The mean maximal manual difference by KT-2000 arthrometer was 6.8 mm(${\pm}1.9$ SD) preoperatively and 1.8 mm(${\pm}0.8$ SD) postoperatively. Conclusion: ACL reconstruction using the flexible reamer achieved the ideal isometric point of femur and anatomic graft placement, so we could obtain good results, especially in rotational stability.

  • PDF

Dosimetric Evaluation of Amplitude-based Respiratory Gating for Delivery of Volumetric Modulated Arc Therapy (진폭 기반 호흡연동 체적변조회전방사선치료의 선량학적 평가)

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Park, Jeong Hoon;Min, Chul Kee;Shin, Dong Oh;Choi, Sang Hyoun;Park, Seungwoo;Huh, Hyun Do
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.127-136
    • /
    • 2015
  • The purpose of this study is to perform a dosimetric evaluation of amplitude-based respiratory gating for the delivery of volumetric modulated arc therapy (VMAT). We selected two types of breathing patterns, subjectively among patients with respiratory-gated treatment log files. For patients that showed consistent breathing patterns (CBP) relative to the 4D CT respiration patterns, the variability of the breath-holding position during treatment was observed within the thresholds. However, patients with inconsistent breathing patterns (IBP) show differences relative to those with CBP. The relative isodose distribution was evaluated using an EBT3 film by comparing gated delivery to static delivery, and an absolute dose measurement was performed with a $0.6cm^3$ Farmer-type ion chamber. The passing rate percentages under the 3%/3 mm gamma analysis for Patients 1, 2 and 3 were respectively 93.18%, 91.16%, and 95.46% for CBP, and 66.77%, 48.79%, and 40.36% for IBP. Under the more stringent criteria of 2%/2 mm, passing rates for Patients 1, 2 and 3 were respectively 73.05%, 67.14%, and 86.85% for CBP, and 46.53%, 32.73%, and 36.51% for IBP. The ion chamber measurements were within 3.5%, on average, of those calculated by the TPS and within 2.0%, on average, when compared to the static-point dose measurements for all cases of CBP. Inconsistent breathing patterns between 4D CT simulation and treatment may cause considerable dosimetric differences. Therefore, patient training is important to maintain consistent breathing amplitude during CT scan acquisition and treatment delivery.

Optimization of Image Tracking Algorithm Used in 4D Radiation Therapy (4차원 방사선 치료시 영상 추적기술의 최적화)

  • Park, Jong-In;Shin, Eun-Hyuk;Han, Young-Yih;Park, Hee-Chul;Lee, Jai-Ki;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.8-14
    • /
    • 2012
  • In order to develop a Patient respiratory management system includinga biofeedback function for4-dimentional radiation therapy, this study investigated anoptimal tracking algorithmfor moving target using IR (Infra-red) camera as well as commercial camera. A tracking system was developed by LabVIEW 2010. Motion phantom images were acquired using a camera (IR or commercial). After image process were conducted to convert acquired image to binary image by applying a threshold values, several edge enhance methods such as Sobel, Prewitt, Differentiation, Sigma, Gradient, Roberts, were applied. The targetpattern was defined in the images, and acquired image from a moving targetwas tracked by matching pre-defined tracking pattern. During the matching of imagee, thecoordinateof tracking point was recorded. In order to assess the performance of tracking algorithm, the value of score which represents theaccuracy of pattern matching was defined. To compare the algorithm objectively, we repeat experiments 3 times for 5 minuts for each algorithm. Average valueand standard deviations (SD) of score were automatically calculatedsaved as ASCII format. Score of threshold only was 706, and standard deviation was 84. The value of average and SD for other algorithms which combined edge detection method and thresholdwere 794, 64 in Sobel, 770, 101 in Differentiation, 754, 85 in Gradient, 763, 75 in Prewitt, 777, 93 in Roberts, and 822, 62 in Sigma, respectively. According to score analysis, the most efficient tracking algorithm is the Sigma method. Therefore, 4-dimentional radiation threapy is expected tobemore efficient if threshold and Sigma edge detection method are used together in target tracking.

Analysis of Test Items of Earth Science and the Applicants' Responses on the Items in the College Scholastic Ability Test (대학수학능력시험의 지구과학영역 문항 및 응시자 반응 분석)

  • Lee, Yang-Rak
    • Journal of the Korean earth science society
    • /
    • v.22 no.6
    • /
    • pp.469-479
    • /
    • 2001
  • This study investigated the trends in the number of applicants and mean score and applicants’ responses on the test items of Earth Science in the College Scholastic Ability Test (CSAT) implemented for 3 years (1999-2001). The percentage of applicants of science track were 43.14% in 1995, but reduced through 29.5% in 2001 to 26.92% in 2002 CSAT For elective subject, about 22% of science track students applied to Earth Science II which ranked third to Biology II and Chemistry II. In 1999, test items were developed to have the expected difficulty 40 ${\sim}$ 59% (6 items) to 60 ${\sim}$ 79% (10 items). But in 2001 every 16 items were developed to have difficulty 60 ${\sim}$ 79%, which was caused by the policy of so called ‘easy CSAT’. Thus the mean score of ‘Earth Science II’ was increased from 50.26 in 1999 through 64.47 in 2000, to 67.58 in 2001. Applicants were generally very good at solving test items focusing on process skills only and familar items but poor at solving test items related to the motion of the earth and planets and sea wave, especially items calling two or more concepts. Thus special measures to cope with the decrease in applicants of science track should be provided. And it is recommended to develop test items with wider range of difficulty and to reduce test items calling process skills only. And special consideration should be given to teaching the content area with poor achievement and high actual difficulty compared to the expected.

  • PDF

The Patterns of Students' Conceptual Changes on Force by Age (나이에 따른 학생들의 힘에 관한 개념 변화 특성)

  • Kim, Yeoun-Soo;Kwon, Jae-Sool
    • Journal of The Korean Association For Science Education
    • /
    • v.20 no.2
    • /
    • pp.221-233
    • /
    • 2000
  • Many investigators have reported difficulties in changing the high school students' misconceptions on mechanics. By one possible solution to this problem, some researchers suggested that the students should be taught mechanics at a younger age to make conceptual changes possible. because as they get older they become less willing to change their ideas. The purpose of this study was to compare the patterns of students' conceptual changes on force by age, to find out whether older students were less ready to change their conceptions than younger students. Individual interviews were carried out with 35 students (average ages 13) in middle school class and 50 students (average ages 17) in high school class near by the middle school. Those students who held the misconcetpion that "motion-implies-force (Impetus conception)" were asked to read a student-centered refutational text (anomalous data). In the immediate and delayed posttest, the types of responses of the students were analyzed to find out the patterns of student's conceptual changes on force by age. In result, first, most of students had impetus conception. Some of the students aged 13 understood the force as terminologies related with everyday experiences, while the students aged 17 understood the force as scientific terminologies. Second, there was no evidence to suggest that conceptual change is more difficult for the students aged 17 than aged 13. Third, the students aged 13 showed diverse responses (plain acceptance, critical acceptance, plain rejection, critical rejection) to the refutational text, while the students aged 17 showed restricted responses (critical acceptance, critical rejection). A month later those students who showed the plain acceptance retrogressed unscientific conceptions, while those students who showed critical acceptance maintained scientific conceptions. We did not find out any evidence to suggest that conceptual change is more difficult for older students. These results need deeper investigation on the nature of the loss of plasticity in comparison with other important variables.

  • PDF

Outcomes of Diffuse-Type Pigmented Villonodular Synovitis (PVNS) after Open Total Synovectomy (미만형 색소 융모 결절성 활액막염의 관혈적 활막 전 절제술 후 경과)

  • Lee, Mo-Ses;Lee, Soo-Hyun;Suh, Jin-Suck;Yang, Woo-Ik;Shin, Kyoo-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.1
    • /
    • pp.27-36
    • /
    • 2010
  • Purpose: Pigmented villonodular synovitis (PVNS) is a rare soft tissue tumor, which usually arises in larger joints, such as the knee. It has a high recurrence rate after surgical treatment. The purpose of this study is to evaluate and analyze the clinical results of diffuse-type pigmented villonodular synovitis cases that were treated with open total synovectomy. Materials and Methods: Between 1994 and 2006, 21 patients who had diffuse-type pigmented villonodular synovitis were selectively reviewed. Among the 21 cases studied, 14 patients presented at the knee, 5 at the ankle, and 2 at the shoulder and elbow. The mean follow up period was 5.5 years (range, 36-157 months). The average age of the patients was 34 years consist of 7 men and 14 women. Clinical outcomes were analyzed retrospectively, including range of motion and complications. Results: Open total synovectomy and adjuvant electrocautrization were done in all cases except one. During the regular follow-up period after the surgery, two patients showed symptoms of recurrence. After re-operation, only one case was pathologically confirmed as a recurrence. The patient who had partial synovectomy and the other patient who had second operation due to recur rence received additional radiation therapy. Clinical outcome scores were improved in every aspect (p<0.0001). 2 out of 14 Patients who had pigmented villonodular synovitis at the knee developed stiff knee after the surgery. Conclusion: After the open total synovectomy with electrocautrization, a low recurrence rate and satisfactory clinical outcome was achieved, observed in a minimum of 3 years of follow-up.

Evaluation of Set-up Accuracy for Frame-based and Frameless Lung Stereotactic Body Radiation Therapy (폐암 정위체부방사선치료 시 고정기구(frame) 사용 유무에 따른 셋업 정확성 평가)

  • Ji, Yunseo;Chang, Kyung Hwan;Cho, Byungchul;Kwak, Jungwon;Song, Si Yeol;Choi, Eun Kyung;Lee, Sang-wook
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.286-293
    • /
    • 2015
  • The purpose of this study was to evaluate the set up accuracy using stereotactic body frame and frameless immobilizer for lung stereotactic body radiation therapy (SBRT). For total 40 lung cancer patients treated by SBRT, 20 patients using stereotactic body frame and other 20 patients using frameless immobilizer were separately enrolled in each group. The setup errors of each group depending on the immobilization methods were compared and analyzed. All patients received the dose of 48~60 Gy for 4 or 5 fractions. Before each treatment, a patient was first localized to the treatment isocenter using room lasers, and further aligned with a series of image guidance procedures; orthogonal kV radiographs, cone-beam CT, orthogonal fluoroscopy. The couch shifts during these procedures were recorded and analyzed for systematic and random errors of each group. Student t-test was performed to evaluate significant difference depending on the immobilization methods. The setup reproducibility was further analyzed using F-test with the random errors excluding the systematic setup errors. In addition, the ITV-PTV margin for each group was calculated. The setup errors for SBF were $0.05{\pm}0.25cm$ in vertical direction, $0.20{\pm}0.38cm$ in longitudinal direction, and $0.02{\pm}0.30cm$ in lateral direction, respectively. However the setup errors for frameless immobilizer showed a significant increase of $-0.24{\pm}0.25cm$ in vertical direction while similar results of $0.06{\pm}0.34cm$, $-0.02{\pm}0.25cm$ in longitudinal and lateral directions. ITV-PTV margins for SBF were 0.67 cm (vertical), 0.99 cm (longitudinal), and 0.83 cm (lateral), respectively. On the other hand, ITV-PTV margins for Frameless immobilizer were 0.75 cm (vertical), 0.96 cm (longitudinal), and 0.72 cm (lateral), indicating less than 1 mm difference for all directions. In conclusion, stereotactic body frame improves reproducibility of patient setup, resulted in 0.1~0.2 cm in both vertical and longitudinal directions. However the improvements are not substantial in clinic considering the effort and time consumption required for SBF setup.

Characteristic Findings of Exercise ECG Test, Perfusion SPECT and Coronary Angiography in Patients with Exercise Induced Myocardial Stunning (게이트 심근관류 SPECT상 운동 유발성 기절심근을 보이는 환자의 운동부하 심전도, 관류 SPECT 및 심혈관 조영술 소견)

  • Ahn, Byeong-Cheol;Seo, Ji-Hyoung;Bae, Jin-Ho;Jeong, Shin-Young;Park, Hun-Sik;Lee, Jae-Tae;Chae, Shung-Chul;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.225-232
    • /
    • 2004
  • Purpose : Transient wall motion abnormality and contractile dysfunction of the left ventricle (LV) can be observed in patients with coronary artery disease due to post-stress myocardial stunning. To understand clinical characteristics of stress induced LV dysfunction, we have compared the findings of exercise stress test, myocardial perfusion SPECT and coronary angiography between subjects with and without post-stress LV dysfunction. Materials and Methods : Among subjects who underwent exercise stress test, myocardial perfusion SPECT and coronary angiography within a month of interval, we enrolled 36 patients with post-stress LV election fraction (LVEF) was $\geq5%$ lower than rest (stunning group) and 16 patients with difference of post-stress and rest LVEF was lesser than 1 %(non-stunning group) for this study. Treadmill exercise stress gated myocardial perfusion SPECT was performed with dual head SPECT camera using 740 MBq Tc-99m MIBI and coronary angiography was also performed by conventional Judkins method. Results : Stunning group had a significantly higher incidence of hypercholesterolemia than non-stunning group(45.5 vs. 7.1%, p=0.01). Stunning group also had higher incidence of diabetes mellitus and lower incidence of hypertension, but these were not statistically significant. Stunning group had larger and more severe perfusion defect in stress perfusion myocardial SPECT than non-stunning group(extent 18.2 vs. 9.2%, p=0.029; severity 13.5 vs. 6.9, p=0.040). Stunning group also had higher degree of reversibility of perfusion defect, higher incidence of positive exercise stress test and higher incidence of having severe stenosis ($80{\sim}99%$) in coronary angiography than non-stunning group, but these were not statistically significant. In stunning group, all of 4 patients without perfusion defect had significant coronary artery stenosis and had received revascularization treatment. Conclusion : Patients with post-stress LV dysfunction had larger and more severe perfusion defect and severe coronary artery stenosis than patients without post-stress LV dysfunction. All of the patients without perfusion defect in stunning group had significant coronary artery stenosis and needed revascularization. Therefore, we suggest that invasive diagnostic procedures and therapeutic interventions might be needed in patients with post-stress LV dysfunction.