• Title/Summary/Keyword: Motion simulator

Search Result 385, Processing Time 0.029 seconds

DEVELOPMENT OF CHEWING SIMULATOR (저작재현장치의 개발)

  • Park, Sung-Ho;Jung, Il-Young;Lee, Kwon-Yong
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.34-40
    • /
    • 2003
  • Chewing simulator, which can partly mimic the motion of chewing motion of human, has been successfully developed. The purpose of its development was to make a new machine which can anticipate the clinical results of restoration in the human teeth more accurately in vitro condition It is composed of 4 major parts, chewing part, motor part, water bath, controlling part. The controlling part control the chewing force, frequency, the temperature and running time of water. Additionally, the actual chewing force and remaining time is shown in the monitor of controlling part. At present, the chewing cycle is composed depending on the pre-published data of foreign people. Long term clinical data should be additionally collected for the simulator to mimic the clinical results more accurately.

Development of Hip Joint Simulator to Evaluate The Wear of Biomaterials Used in Total Hip Joint Replacement (인공고관절 생체재료 마멸평가를 위한 시뮬레이터 개발)

  • 이권용;윤재웅;전승범;박성길
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.265-270
    • /
    • 2001
  • Hip joint simulator which Is an essential device for evaluating the wear of biomaterials (ultrahigh molecular weight polyethylene, Co-Cr alloy, alumina, etc.) used in total hip joint replacement was developed. This hip joint simulator mimics the joint motion and joint loading of human gait by adapting the 4 degree of freedom in kinematic motion (flexing/extension, adduction/abduction, Internal rotation/external rotation) and axial loading, Four stations are operated by 8 servo-motors and harmony drives. Joint leading was imposed by displacement control from a ball screw, LM guide, and spring system. Each kinematic link system operates separately or coupled modes. A heater and a thermocouple were installed for keeping the body temperature in each station.

  • PDF

Development of a Simulator for the biped-walking robot using the open inventor (Open Inventor를 이용한 이족보행로봇의 시뮬레이터의 개발)

  • 최형식;김영식;전대원;우정재;김명훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.296-299
    • /
    • 2001
  • We developed a motion capture system to get angle data of human joints in the walking mode. The motion capture system is a pair of leg-shape device, which is composed of three links with ankle, knee and pelvis joints. The sensors for measurement of the joint angle are potentiometers. We used an A/D converter to get digital data from joint angles, and which are used to simulate and coordinate the biped-walking robot developed in our laboratory. To simulate and analyze walking motion, animation based on three-dimension motion is performed using the open inventor software.

  • PDF

Estimation of Rider's Action Force from Measurement of Motion Platform Control Force in the 6 DOF Bicycle Simulator (6 자유도 자전거 시뮬레이터의 운동 장치 제어력을 이용한 운전자의 작용력 추정)

  • 신재철;이종원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.842-847
    • /
    • 2002
  • One of the challenging problems with bicycle simulators is to deal with the inherent unstable bicycle dynamics that is coupled with rider's motion. For the bicycle dynamics calculation and the real time simulation, it is necessary to identify the control inputs from the rider as well as the virtual environments. The six control forces of the Stewart platform-based motion system are used for estimation of the rider's action force, which is one of the important control inputs, but of which the direct measurement is impractical. For the effective estimation of the rider's action force, the dynamics model of the motion system is derived incorporated with both analytical and experimental methods and the sliding mode controller with perturbation estimation is developed.

  • PDF

Design of Trajectory Generator for Performance Evaluation of Navigation Systems

  • Jae Hoon Son;Sang Heon Oh;Dong-Hwan Hwang
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.4
    • /
    • pp.409-421
    • /
    • 2023
  • In order to develop navigation systems, simulators that provide navigation sensors data are required. A trajectory generator that simulates vehicle motion is needed to generate navigation sensors data in the simulator. In this paper, a trajectory generator for evaluating navigation system performance is proposed. The proposed trajectory generator consists of two parts. The first part obtains parameters from the motion scenario file whereas the second part generates position, velocity, and attitude from the parameters. In the proposed trajectory generator six degrees of freedom, halt, climb, turn, accel turn, spiral, combined, and waypoint motions are given as basic motions with parameters. These motions can be combined to generate complex trajectories of the vehicle. Maximum acceleration and jerk for linear motion and maximum angular acceleration and velocity for rotational motion are considered to generate trajectories. In order to show the usefulness of the proposed trajectory generator, trajectories were generated from motion scenario files and the results were observed. The results show that the proposed trajectory generator can accurately simulate complex vehicle motions that can be used to evaluate navigation system performance.

Analysis of the Contact Pressure Distribution and Kinetics of Knee Implant Using the Simulator (Simulator를 이용한 인공무릎관절 접촉면의 압력분포 및 운동성 분석)

  • 이문규;김종민;김동민;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.363-367
    • /
    • 2003
  • Contact area and pressure are important factors which directly influence a life of knee implants. Since implant's mechanical functions should be experimentally evaluated for clinical use, many studies using a knee simulator and a pressure sensor system have been conducted. However it has not been reported that the contact pressure's distribution of a knee implant motion was estimated in real-time during a gate cycle. Therefore. the objective of this study was to analyze the contact pressure distribution for the motion of a joint using the knee simulator and I-scan sensor system. For this purpose, we developed a force-controlled dynamic knee simulator to evaluate the mechanical performance of artificial knee joint. This simulator includes a function of a soft tissue and has a 4-degree-of-freedom to represent an axial compressive load and a flexion angle. As axial compressive force and a flexion angle of the femoral component can be controlled by PC program. The pressure is also measured from I-scan system and simulator to visualize the pressure distribution on the joint contact surfaces under loading condition during walking cycle. The compressive loading curve was the major cause for the contact pressure distribution and its center move in a cycle as to a flexion angie. In conclusion, this system can be used to evaluate to the geometric interaction of femoral and tibial design due to a measured mechanical function such as a contact pressure, contact area and a motion of a loading center.

A study on Estimation of Energy Expenditure using Horseback Riding Simulator (승마 시뮬레이터를 이용한 운동 시 에너지 소모량 추정에 관한 연구)

  • Park, Seongbin;Hyeong, Chun-Ho;Kim, Sayup;Chung, Kyung-Ryul
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.2
    • /
    • pp.193-198
    • /
    • 2013
  • The horseback riding simulator, an exercise training machine providing a simplified horse riding motion has been developed for aiming at healthcare. The purpose of this study was to estimate the energy expenditure without measuring bio-signals using the simulator. The test protocol was consisted of increase up to maximal intensity(Motion 9) and decrease down to minimal intensity(Motion 4) during 25 minutes, and energy expenditure was measured by portable cardiopulmonary exercise testing analyzer. There were significant differences in energy expenditure according to each riding motion. The result will be able to estimate energy expenditure using motion level, exercise time, age and gender during the riding.

Hardware-In-the-Loop Simulation for Development of Fin Stabilizer

  • Yoon, Hyeon Kyu;Lee, Gyeong Joong
    • International Journal of Ocean System Engineering
    • /
    • v.3 no.1
    • /
    • pp.10-15
    • /
    • 2013
  • A ship cruising in the ocean oscillates continuously due to wave action. In order to reduce the ship's roll, we developed a fin stabilizer as an anti-rolling device for a 500-ton-class high-speed marine vessel. During the development phase, it was necessary to set up control gains for the motion and hydraulic systems and assess the effectiveness of the anti-rolling performance on the ground. For this reason, a Target Simulator, which simulated the ship's motion, was given operator inputs such as the engine telegraph and waterjet deflection angle, and generated roll using a one-degree-of-freedom motion base. Hardware-In-the-Loop Simulation (HILS) was performed using the Target Simulator in order to confirm the various logics of the developed fin stabilizer, select initial control gains, and estimate the anti-rolling performance. In conclusion, it was confirmed that HILS was very helpful to develop the fin stabilizer because it could reduce the number of sea trial tests that were needed and could find many malfunctions in the factory a priori.