• 제목/요약/키워드: Motion Study

검색결과 9,669건 처리시간 0.034초

Immediate Effect of Sustained Stretching Exercises with Far Infrared on the Ankle Range of Motion and Muscle Tone in Patients with Stroke

  • Youn, Pong Sub;Park, Shin Jun
    • The Journal of Korean Physical Therapy
    • /
    • 제31권1호
    • /
    • pp.56-61
    • /
    • 2019
  • Purpose: The spasticity of stroke patients decreases the ankle range of motion and increases the gastrocnemius muscle tone. This study examined the effects of stretching exercise and far infrared irradiation on the ankle function in stroke patients with spasticity. Methods: This study was conducted on 20 stroke patients admitted to Jesaeng General Hospital, who were divided into a study group (stretching exercise with far infrared) and control group (stretching exercise only). The dorsiflexion range of motion was measured using a smartphone and the medial gastrocnemius muscle tone and stiffness were measured using a Myoton pro. Results: With the exception of the non-paretic gastrocnemius muscle tone in the control group, the medial gastrocnemius muscle tone and stiffness decreased significantly in both groups. In both groups, the dorsiflexion range of motion increased significantly. In addition, the experimental group had a significantly higher dorsiflexion range of motion than the control group. On the other hand, there was no significant difference between the two groups in terms of the medial gastrocnemius muscle tone and stiffness. Conclusion: For stroke patients with spasticity, stretching exercises increased the ankle's range of motion and decreased the gastrocnemius muscle tone. The addition of heat therapy further increased the ankle's range of motion. On the other hand, as the sample size was small, future studies should include more subjects.

Trends of Intellectual Property on Musculoskeletal Disorder, Motion Capture Technology and Ergonomics

  • Yoon, Sang-Young;Jung, Myung-Chul
    • 대한인간공학회지
    • /
    • 제34권5호
    • /
    • pp.437-445
    • /
    • 2015
  • Objective: The aims of this study are to investigate the trends of intellectual property in order to identify the ergonomic approaches on musculoskeletal disorders, harmful factors of musculoskeletal disorders, and to find the potential applicability of motion capture technology. Background: Ergonomic posture assessment tools often showed interrater variance, though the usage is easy and practical in industrial fields. Moreover new technologies such as motion capture showed the potential applicability in posture assessment. So ergonomists and practitioners became interested in the intellectual properties on musculoskeletal disorder and motion capture technology. Method: Intellectual properties were collected with the combination of keywords such as ergonomic, musculoskeletal disorder, and motion capture using the KIPRIS (Korea Intellectual Property Rights Information Service). Collected intellectual properties were classified into ergonomic area and non-ergonomic area, except unexamined intellectual properties. This study investigated the trend of application of intellectual properties and the probability of using motion capture technology. Results: Few intellectual properties with ergonomic approach on musculoskeletal disorders were founded, despite many products for rehabilitation and sports. One hundred twenty five patents in 1105 patents on musculoskeletal disorders and 138 patents in 1908 patents on motion capture technology were classified into the patents that ergonomic approach can be applied. The patents related to ergonomics area are rapidly increasing after 2010, and there are good opportunities for ergonomists to apply the patents. Conclusion: This study found opportunities on novel methodology in detecting the harmful factors of musculoskeletal disorders, and that the motion capture technology is applicable in ergonomic posture assessment. Application: The results of this study can help ergonomists prepare the ergonomic patents, and can show the potential use of motion capture technology in detecting the harmful posture of musculoskeletal disorders.

A Study on the Reliability and Validity of Measuring the Range of Motion of the Elbow Joint Using a Smartphone Application

  • Lee, Jun Cheol
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제10권3호
    • /
    • pp.65-72
    • /
    • 2018
  • The purpose of this study was to assess the intra-tester and inter-tester reliability and validity of elbow flexion range of motion using a smart phone used by the general public. Thirty-one general people participated in this study. The range of motion in active elbow flexion was measured with a goniometer and smart phone over two times by two observers. The intra-taster and inter-tester reliability were evaluated using the intraclass correlation coefficient(ICC). The validity was measured by Pearson's correlation coefficient. The intra-observer reliability was good in all measured items ICC>0.900. The inter-observer reliability was high with ICC>0.806. All correlation coefficients of android app and goniometer were greater than 0.868 and showed a significant positive correlation (p<0.01). The range of motion measurement with a smart phone showed acceptable reliability. Therefore, using a smartphone to measure the range of motion of the elbow joint could provide convenience and economic benefits.

A Study on MTL Device Design and Motion Tracking in Virtual Reality Environments

  • Oh, Am-Suk
    • Journal of information and communication convergence engineering
    • /
    • 제17권3호
    • /
    • pp.205-212
    • /
    • 2019
  • Motion tracking and localization devices are an important building block of motion tracking systems in a virtual reality (VR) environment. This study is about improving the accuracy of motion and location for enhancing user immersion in experience type VR environment to position tracking technique. In this study, we propose and test a design of such a device. The module data test of the attitude and heading reference system shows that the implementation with the MPU-9250 sensor is successful and adequate to be used with short operation time. We consider various sensor hardware dependencies of VR, and compare various correction methods and filtering methods to lower the motion to photon (MTP) time that user movement is fully reflected on the display using sensor devices. The Kalman filter is used to combine the accelerometer with the gyroscope in the sensing unit.

추계학적 점지진원 모델을 사용한 한반도 지반 운동의 경로 감쇠 효과 평가 (Estimation of Path Attenuation Effect from Ground Motion in the Korean Peninsula using Stochastic Point-source Model)

  • 지현우;한상환
    • 한국지진공학회논문집
    • /
    • 제24권1호
    • /
    • pp.9-17
    • /
    • 2020
  • The stochastic point-source model has been widely used in generating artificial ground motions, which can be used to develop a ground motion prediction equation and to evaluate the seismic risk of structures. This model mainly consists of three different functions representing source, path, and site effects. The path effect is used to emulate decay in ground motion in accordance with distance from the source. In the stochastic point-source model, the path attenuation effect is taken into account by using the geometrical attenuation effect and the inelastic attenuation effect. The aim of this study is to develop accurate equations of ground motion attenuation in the Korean peninsula. In this study, attenuation was estimated and validated by using a stochastic point source model and observed ground motion recordings for the Korean peninsula.

연직지반운동이 자립형 구조체의 Rocking 거동에 미치는 영향 (Effects of Vertical Ground Motion on Rocking Response of Free Standing Structure)

  • 최인길;전영선
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.169-176
    • /
    • 1997
  • In this study, vertical ground motion effects on rocking response of free standing structure are investigated. Based on the mathematical model, computer program is developed using Kutta's Fourth-Order Method. Using the program, several parametric studis are performed to predict the effects of vertical ground motion. From the results of this study, it can be found that the vertical ground motion may overturn the structure which is stable under the horizontal ground motion, stabilize the structure which overturns due to horizontal ground motion alone, and delay the time of overturning of the structure or greatly reduce the rocking of the structure. It is concluded that the effect of vertical ground motion on the rocking response of free standing structure is apparently not systematic.

  • PDF

Classification of Behavioral Lexicon and Definition of Upper, Lower Body Structures in Animation Character

  • Hongsik Pak;Suhyeon Choi;Taegu Lee
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제15권3호
    • /
    • pp.103-117
    • /
    • 2023
  • This study focuses on the behavioural lexical classification for extracting animation character actions and the analysis of the character's upper and lower body movements. The behaviour and state of characters in the animation industry are crucial, and digital technology is enhancing the industry's value. However, research on animation motion application technology and behavioural lexical classification is still lacking. Therefore, this study aims to classify the predicates enabling animation motion, differentiate the upper and lower body movements of characters, and apply the behavioural lexicon's motion data. The necessity of this research lies in the potential contributions of advanced character motion technology to various industrial fields, and the use of the behavioural lexicon to elucidate and repurpose character motion. The research method applies a grammatical, behavioural, and semantic predicate classification and behavioural motion analysis based on the character's upper and lower body movements.

2,30대 정상 성인남녀의 몸통 굽힘 시 골반의 기울임과 몸통 움직임 및 몸통 폄 근의 상관관계 연구 (Correlation between Pelvic Tilt Angle with Trunk Motion and Trunk Extensor during Trunk Forward Flexion in Adults Aged 2,30)

  • 박영주;이상열
    • 대한통합의학회지
    • /
    • 제7권1호
    • /
    • pp.81-88
    • /
    • 2019
  • Purpose : The purpose of this study was to examine if there is any correlation between pelvic tilt angle and trunk motion and trunk extensor during trunk forward flexion and to measure trunk motion, onset time of trunk motion, and onset time of trunk extensor activation. Methods : The subjects of this study were 42 healthy adults. The subjects had no back pain due to neurological disease and no experience of back surgery. After pelvic tilt angle was measured, each trunk forward flexion was performed three times. Trunk motion and onset time of trunk motion were measured using Myomotion. Four sensors were used, with one located at the upper thoracic (below $C_7$), the lower thoracic ($T_{12}-L_1$), the sacrum ($S_1$), and at the center of the anterior femur. Onset time of trunk extensors (spinalis, longissimus, gluteus medius, gluteus maximus, biceps femoris, and gastrocnemius) activation was measured using a wireless surface EMG. The EMG amplitude was normalized by using the reference voluntary contraction (RVC). The statistical significance of the results were evaluated using Pearson's correlation test. Results : The correlation between pelvic tilt angle and lumbar motion, onset time of pelvis motion, and onset time of gluteus medius activation was statistically significant in a positive direction (p<.05). The correlation between pelvic tilt angle with pelvis motion, onset time of lumbar motion, and onset time of longissimus activation showed a statistically significant negative correlation (p<.05). Conclusion : The study results provide a significant contribution to our understanding of the lumbar load at the initial stage of trunk flexion. Therefore, it may be possible to provide basic data for evaluation and treatment, such as orthodontic treatment for alignment of the spine and back pain. In addition, it is necessary to focus on normal exercise pattern reeducation as well as pelvic correction during exercise in daily life or in industrial fields.

움직임 벡터의 신뢰성 향상을 위한 스무딩 방법에 관한 연구 (A Study on Montion Vector Smoothing for Reliability Improvement)

  • 김진태;김기현;최종수
    • 전자공학회논문지B
    • /
    • 제31B권5호
    • /
    • pp.108-116
    • /
    • 1994
  • In this paper, we propose a new motion vector smoothing scheme which has high reliability and coding efficiency of motion vectors. In motion vector filed, groupings are made using angle and magnitude of the motion vectors. In each group, the unreliable motion vectors are corrected by the motion vector smoothing. In 3$\times$3 window, motion vector of the current block is made to group, and the motion vector smoothing is performed only in that group. Result of computer simulation shows much improvement of the reliability of motion vectors. Moreover, coding bits of the motion vector are diminished from 0.967 to 6.773 bits per block.

  • PDF

배드민턴 클리어와 드롭 동작에 대한 운동학적 분석 (A Kinematic Analysis on Clear & Drop Motion of Badminton)

  • 송주호
    • 한국운동역학회지
    • /
    • 제13권3호
    • /
    • pp.217-229
    • /
    • 2003
  • The purpose of this study was to present the basic data on improving the skills for 3 junior high school national badminton players in clear and drop motion through the 3-dimensional image analysis. Therefore, the results of this study are as follows: 1. In the duration times per phase, subject C relatively showed a similar time between clear and drop motion. Accordingly, C took a more effective motion than A and B. 2. In the velocities of racket head, subject A and C showed similar changes relatively. However, in case of subject B, the velocity was decreased before back swing(E2) and increased until impact(E3). 3. Regardless of clear and drop motion, the changing phases of joint angle for wrist and elbow showed similar changes comparatively. 4. In the angles of upper body, clear motion was average 85.0 degree and drop one was average 80.7 degree during the impact(E3). Hence, it showed that drop motion hit the ball bowing the upper body more than clear one. 5. In the angles of racket head, clear motion was average 87.7 degree and drop one was average 85.6 degree during the impact(E3). Consequently, drop motion was impacted forward more than clear one.