• Title/Summary/Keyword: Motion Ratio

Search Result 1,366, Processing Time 0.03 seconds

Development of a Human Motion Analyzer (인체 동작 분석기의 개발)

  • 김민기;김성호
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.217-222
    • /
    • 1995
  • We propose some applications of image processing techniques to extract quantitative measurements by using a camera system developed in Korea university and Catholic Medical School. From now on the system will be called as KCMOTION. The purpose of this study is to provide basic kinematic and kinetic data for the analysis of human movements and to find the clinical usefulness and reliability of the proposed motion analysis system. Two tests, sit-to-stand (STS) movements and pendulum test, are conducted by the system. The aims of the tests are to identify variability and reliability of KCMOTION to give some quantitative comparisons to the other systems. The result of STS movement are compared to the LOCUS IIID motion analyzer by the ratio of maximum flexion movement per body weight to the actual maximum flexion extension torque per body weight. That result in 29 % and 33 % for hip and knee joint, respectively in KCMOTION and 27 % and 30 % in LOCUS IIID System. The results of the pendulum movements are compared to that of using Cybex and Electrogoniometer with relaxation index, amplitude ratio, swing number and swing time. The results of relaxation index and amplitude ratio of the KCMOTION are between those of the Cybex and Electrogoniometer. We also observed that the KCMOTION detect more natural movement, from the results of swing number and time.

  • PDF

Filter Design to Eliminate Motion Artifact of Pulse Oximetery (펄스 옥시메터의 동잡음 제거 필터 설계)

  • 이주원;이종희;강익태;김경하;이건기
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.431-438
    • /
    • 2001
  • Oxygen saturation of blood is defined as ratio of total hemoglobins density to oxyhemoglobins density And the accuracy of pulse oxymeter that measures the oxygen saturation of blood by a noninvasive method is influenced by a measuring environment, breathing and motion of patient. Especially when patient moved his arms and fingers, it is difficult to eliminate motion artifact because the motion artifact signal has features that are overlap or closed at normal signal in frequency domain. We propose the filtering method that construct the filter banks and a matched falter to improve the Problem. When experimented by the proposed method, the ratio regulation of the proposed methods has 4.1% below than an adaptive filter (39.7%) and a moving average filter (11.2%). So. the Proposed method will be able to get a stable ratio of SpO2.

  • PDF

Effects of PNF Program on Neck Pain, Cervical Range of Motion, Pressure Pain, and Cervical Flexion-Relaxation Ratio in VDT Worker: a Case Study (VDT 직업 종사자의 목 통증, 목뼈 운동범위, 누름통증, 목뼈 굽힘-이완 비율에 PNF 프로그램이 미치는 영향: 증례보고)

  • Kim, Yong-Hun;Jung, Ju-Hyeon
    • PNF and Movement
    • /
    • v.13 no.4
    • /
    • pp.197-202
    • /
    • 2015
  • Purpose: This study aimed to examine the effects of a proprioceptive neuromuscular facilitation (PNF) program on neck pain, cervical range of motion, pressure pain, and the cervical flexion-relaxation ratio in a visual display terminal (VDT) worker. Methods: We recruited a 33-year-old VDT worker diagnosed with chronic VDT syndrome. The subject was treated using a PNF program for 20 minutes a day, three times a week for six weeks. All evaluations were performed every two weeks on the first test day. Results: The PNF program resulted in a significant improvement in the subject's neck pain, cervical range of motion, pressure pain, and the cervical flexion-relaxation ratio after six weeks, in comparison to the subject's condition before treatment. Conclusion: The PNF program can be used effectively to improve neck pain, cervical range of motion, pressure pain, and the cervical flexion-relaxation ratio in visual display terminal (VDT) workers.

Analysis of the Female 500m Sprint Starting Motion in Short Track Speed Skating (여자 500m 쇼트트랙 스피드 스케이팅의 스타트 기술분석)

  • Back, Jin-Ho;Kwak, Chang-Soo;Chung, Nam-Ju
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.285-299
    • /
    • 2004
  • The purpose of this study is to identify female 500m sprint start motion by the center of gravity position in short track speed skating. The center of gravity position ratio was divided into three type(type A front : 80%-back : 20%, type B front : 70%-back 30%, type C front: 50%-back : 50%). Three video cameras were used for 3D motion analysis with DLT method and the results were as follows: The elapsed time in starting motion was appeared that type B was the shortest and type A was the longest. It was appear that the stroke length of type A was longer than that type B and C during starting phase. This result was similar to displacement of center of gravity. It was appeared that skill type of center of gravity position ratio type B' ankle and knee joint angle were lower than that of type A and C. Observing these results it was conclusion that skill type B of center of gravity position ratio was more faster than that of type A and C. But it is important that these skill type needed to verifying more subjects.

Slow Motion of a Circular Cylinder Near the Plane Interface of Viscous Fluids (점度 가 相異한 流體境界面 근처 에서 圓柱주위 의 二次元 低速流動 의 解析)

  • 오세훈;강신영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.7 no.2
    • /
    • pp.175-185
    • /
    • 1983
  • When a circular cylinder near the plane fluid-interface of different viscosities is in parallel and normal motion, solutions of the Oseen equation are obtained. Classical image method with Faxen's integral form is used to satisfy the boundary conditions on the plane interface. Coefficients of drag and lift increase as a cylinder approaches to the interface. But drag-coefficients of parallel motions with viscosity-ratio less than unity are decreased slightly. They show monotonic increase with Reynolds number in case of parallel motion, but minimum values of drag coefficients in normal motion are appeared. On the other hand Stokes' solution are obtained by taking limits of low Reynolds number except the case of parallel motion with viscosity-ratio not equal to infinity.

Object-oriented coder using pyramid structure and local residual compensation (피라미드 구조 및 국부 오차 보상을 이용한 물체지향 부호화)

  • 조대성;박래홍
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.12
    • /
    • pp.3033-3045
    • /
    • 1996
  • In this paper, we propse an object-oriented coding method in low bit-rate channels using pyramid structure and residual image compensation. In the motion estimation step, global motion is estimated using a set of multiresolution images constructed in a pyramid structure. We split an input image into two regions based on the gradient value. Regions with larte motions obtain observation points at low resolution level to guarantee robustness to noise and to satisfy a motion constraint equation whereas regions with local motions such as eye, and lips get observation points at the original resolution level. Local motion variations and intesity variations of an image reconstructed by the golbal motion are compensated additionally by using the previous residual image component. Finally, the model failure (MF) region is compensated by the pyramid mapping of the previous displaced frame difference (DFD). Computer simulation results show that the proposed method gives better performance that the convnetional one in terms of the peak signal to noise ratio (PSNR), compression ratio (CR), and computational complexity.

  • PDF

Motion Estimation and Compensation based on Advanced DCT (변환 영역에서 개선된 DCT를 기반으로 한 움직임 예측 및 보상)

  • Jang, Young;Cho, Hyo-Moon;Cho, Sang-Bock
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.38-40
    • /
    • 2007
  • In this paper, we propose a novel architecture, which is based on DCT (Discrete Cosine Transform), for ME (Motion Estimation) and MC (Motion Compensation). The traditional algorithms of ME and MC based on DCT did not suffer the advantage of the coarseness of the 2-dimensional DCT (2-D DCT) coefficients to reduce the operational time. Therefore, we derive a recursion equation for transform-domain ME and MC and design the structure by using highly regular, parallel, and pipeline processing elements. The main difference with others is removing the IDCT block by using to transform domain. Therefore, the performance of our algorithm is more efficient in practical image processing such as DVR (Digital Video Recorder) system. We present the simulation result which is compare with the spatial domain methods. it shows reducing the calculation cost. compression ratio. and peak signal to noise ratio (PSNR).

  • PDF

Comparison of Ranges of Motion in The Thoracolumbar Region for Clinical Diagnoses of Patients with Chronic Low Back Pain (만성요통 환자의 질환명에 따른 흉요추부의 관절가동범위 비교)

  • Lee, Sang-Wook;Kim, Suhn-Yeop
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.3
    • /
    • pp.363-373
    • /
    • 2010
  • Purpose : The purpose of this study was to compare differences in thoracolumbar ranges of motions by comparing ratios among 4 type diagnosis for patient with chronic low back pain. Methods : The subjects were 58 chronic low back pain patients. A motion analysis program (Global Postural System) was used after photography for posture measurement. To analyze differences in mobility percentages and ratios of thoracolumbar ranges of motion, one-way ANOVA was used. Results : Regional difference spinal posture and movement were found to diagnosis patients with chronic low back pain. Comparison of thoracolumbar ranges of motion revealed significant differences in the thoracic region during forward-bending of the trunk (p<.05). In the upper thoracic region, the herniated intervertebral lumbar disc (HILD) group was significantly larger than the spinal stenosis/herniated intervertebral lumbar disc (SS/HILD) group (p<.05). In the lower thoracic region, chronic sprains (CS) were significantly greater than in the spinal stenosis (SS) group and in the (SS/HJLD) group (p<.05). Comparative analysis of thoracic/lumbar mobility ratio showed the CS group's ratio during forward bending was largest: 1.66, while the HILD group's ratio was smallest: 84 a significant difference between the two groups (p<.01). Diagnosis was not associated with difference in thoracolumbar backward-bending range of motion (p>.05). Conclusion : Theses results indicate the clinical efficacy of diagnosing for chronic low back pain by evaluating spinal mobility.

Design tables and charts for uniform and non-uniform tuned liquid column dampers in harmonic pitching motion

  • Wu, Jong-Cheng;Wang, Yen-Po;Chen, Yi-Hsuan
    • Smart Structures and Systems
    • /
    • v.9 no.2
    • /
    • pp.165-188
    • /
    • 2012
  • In the first part of the paper, the optimal design parameters for tuned liquid column dampers (TLCD) in harmonic pitching motion were investigated. The configurations in design tables include uniform and non-uniform TLCDs with cross-sectional ratios of 0.3, 0.6, 1, 2 and 3 for the design in different situations. A closed-form solution of the structural response was used for performing numerical optimization. The results from optimization indicate that the optimal structural response always occurs when the two resonant peaks along the frequency axis are equal. The optimal frequency tuning ratio, optimal head loss coefficient, the corresponding response and other useful quantities are constructed in design tables as a guideline for practitioners. As the value of the head loss coefficient is only available through experiments, in the second part of the paper, the prediction of head loss coefficients in the form of a design chart are proposed based on a series of large scale tests in pitching base motions, aiming to ease the predicament of lacking the information of head loss for those who wishes to make designs without going through experimentation. A large extent of TLCDs with cross-sectional ratios of 0.3, 0.6, 1, 2 and 3 and orifice blocking ratios ranging from 0%, 20%, 40%, 60% to 80% were inspected by means of a closed-form solution under harmonic base motion for identification. For the convenience of practical use, the corresponding empirical formulas for predicting head loss coefficients of TLCDs in relation to the cross-sectional ratio and the orifice blocking ratio were also proposed. For supplemental information to horizontal base motion, the relation of head loss values versus blocking ratios and the corresponding empirical formulas were also presented in the end.

Robust Motion Compensated Frame Interpolation Using Weight-Overlapped Block Motion Compensation with Variable Block Sizes to Reduce LCD Motion Blurs

  • Lee, Jichan;Choi, Jin Hyuk;Lee, Daeho
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.5
    • /
    • pp.537-543
    • /
    • 2015
  • Liquid crystal displays (LCDs) have slow responses, so motion blurs are often perceived in fast moving scenes. To reduce this motion blur, we propose a novel method of robust motion compensated frame interpolation (MCFI) based on bidirectional motion estimation (BME) and weight-overlapped block motion compensation (WOBMC) with variable block sizes. In most MCFI methods, a static block size is used, so some block artefacts and motion blurs are observed. However, the proposed method adjusts motion block sizes and search ranges by comparing matching scores, so the precise motion vectors can be estimated in accordance with motions. In the MCFI, overlapping ranges for WOBMC are also determined by adjusted block sizes, so the accurate MCFI can be performed. In the experimental results, the proposed method strongly reduced motion blurs arisen from large motions, and yielded interpolated images with high visual performance and peak signal-to-noise ratio (PSNR).