• 제목/요약/키워드: Motion Range

검색결과 3,088건 처리시간 0.03초

정상 성인의 견, 고관절 가동범위에 대한 조사 (Shoulder and Hip Joint Range of Motion in Normal Adults)

  • 함용운
    • The Journal of Korean Physical Therapy
    • /
    • 제3권1호
    • /
    • pp.97-108
    • /
    • 1991
  • The purpose of this article is to know the standard figures of joint range of motion, in conjuction with age and sen, for normal adults. The results of assessment and analysis io shoulder and hip joint range of motion are as follows : 1) The average shoulder joint range of motion in normal adults are $160.5^{\circ}$ in flexion, $53.5^{\circ}$ in extension, $159.3^{\circ}$ in adduction, $62.3^{\circ}$ in internal rotation, $83.9^{\circ}$ in external rotation, The average hip joint range of motions are $116.8^{\circ}$ in flexion, $16.1^{\circ}$ in extension, $41.1^{\circ}$ in abduction, $33.8^{\circ}$ in abduction, $40.0^{\circ}$ in interne rotation, $41.2^{\circ}$ in external rotation. 2) There is no significant difference in shoulder and hip joint range of motion between male and female (p>0.05). 3) As to the inter-relation in age and range of motion, the left flexion and extension, internal rotation and right extension in shoulder joint is decreased gradually with increasing age, and left flexion (knee flexion, knee extension) and right flexion (knee extension) in hip joint is decreased with increasing age (p<0.01). 4) Relating to age and sex, the twenties male shows highest range of motion in shoulder and hip joint, with .the fifties female shows, lowest range of motion.

  • PDF

3차원 동작분석법을 활용한 골프웨어 평가를 위한 기초연구 - 상체 동작범위를 중심으로 - (Evaluation Method for Fit of Golf wears based on 3D Motion Analysis - Focus on motion range of upper body -)

  • 정혜원;신주영;남윤자
    • 한국의류산업학회지
    • /
    • 제18권3호
    • /
    • pp.338-350
    • /
    • 2016
  • The purpose of this study is to analyze joint angle for a range of swing motion derived through 3D motion analysis in order to design the ergonomic golf wear, use it for evaluation method of apparel fit to improve exercise functionality and provide the basic materials necessary for designing clothes. In order to do this, the subjects for this study were 3 men of age 20s. The data for a range of motion of golf swing were collected by using equipment for 3D motion analysis and then were used for analysis of joint angles and evaluation method of apparel fit. Range of motion was derived through 3D motion analysis of golf swing motion and joint angles for items of joint motion item and of X, Y, and Z-axis were calculated, respectively. In order to set the evaluation questions for evaluation of apparel fit, to find a range of motion at the maximal value and the minimal value of swing motion. As a result, during the swinging motion, neck extension, right shoulder extension, right/left elbow extension, right/left elbow supination did not appear. Items of joint motion showing the maximum at range of each swing motion were applied into 55 questions and consisted. The results of this study were meaningful as a basic study to apply 3D motion analysis to the fashion industry. It's expected to be used to design functional clothing.

Immediate Effect of Sustained Stretching Exercises with Far Infrared on the Ankle Range of Motion and Muscle Tone in Patients with Stroke

  • Youn, Pong Sub;Park, Shin Jun
    • The Journal of Korean Physical Therapy
    • /
    • 제31권1호
    • /
    • pp.56-61
    • /
    • 2019
  • Purpose: The spasticity of stroke patients decreases the ankle range of motion and increases the gastrocnemius muscle tone. This study examined the effects of stretching exercise and far infrared irradiation on the ankle function in stroke patients with spasticity. Methods: This study was conducted on 20 stroke patients admitted to Jesaeng General Hospital, who were divided into a study group (stretching exercise with far infrared) and control group (stretching exercise only). The dorsiflexion range of motion was measured using a smartphone and the medial gastrocnemius muscle tone and stiffness were measured using a Myoton pro. Results: With the exception of the non-paretic gastrocnemius muscle tone in the control group, the medial gastrocnemius muscle tone and stiffness decreased significantly in both groups. In both groups, the dorsiflexion range of motion increased significantly. In addition, the experimental group had a significantly higher dorsiflexion range of motion than the control group. On the other hand, there was no significant difference between the two groups in terms of the medial gastrocnemius muscle tone and stiffness. Conclusion: For stroke patients with spasticity, stretching exercises increased the ankle's range of motion and decreased the gastrocnemius muscle tone. The addition of heat therapy further increased the ankle's range of motion. On the other hand, as the sample size was small, future studies should include more subjects.

시간해상도 감소 트랜스코딩을 위한 ASW움직임벡터 정밀화 알고리즘에 관한 연구 (Efficient Motion Refinement Algorithm based on ASW for Reduced Frame-Rate Video Transcoder)

  • 서동완;권혁민;최윤식
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 Ⅳ
    • /
    • pp.2044-2047
    • /
    • 2003
  • In this paper, we propose efficient motion vector refinement algorithm for frame-rate reduction transcoding. The proposed algorithm is to set the search range for motion refinement based on the incoming motion vector. The algorithm calculates the importance of motion vector of the skipped frame and then selects two motion vector to set search range. Through this process, we determine the accuracy of incoming motion vector and set the search range lot refinement adaptively by means of the accuracy. In experiments, we show efficiency of our algorithm to reduce the search points for refinement.

  • PDF

관성측정장치를 이용한 경추 가동범위 측정에 대한 고찰 (A review on measuring cervical range of motion using an inertial measurement unit)

  • 임주혁;김현호;박영재;박영배
    • 대한한의학회지
    • /
    • 제38권1호
    • /
    • pp.56-71
    • /
    • 2017
  • Objectives: The purpose of this study was to review the article using an IMU(Inertial Measurement Unit) for measuring the cervical range of motion and to evaluate the feasibility of using an IMU for measuring the cervical range of motion. Method: Scopus was used to search for the articles relating to the inclusion criteria. Which is measuring the cervical range of motion using an IMU. A total of 15 articles were selected through discussion. Degree and the reliability of the cervical range of motion and the validity of the data within the articles were extracted. Results: The measurement of the cervical range of motion using an IMU were $92.25^{\circ}$ to $138.2^{\circ}$, $122.4^{\circ}$ to $154.9^{\circ}$, $73.75^{\circ}$ to $93.1^{\circ}$ on the sagittal plane, transverse plane, and coronal plane respectively. 38 of the 43 values showed good reliability. They were larger than 0.75. 5 of the 43 values showed reliability less than 0.75. They were measured by smart phone. 16 of the 21 values showed good validity. The remaining 5 were measured by smart phone. The lower reliability and validity of smart phone were related to the protocol. The IMU can measure the coupling motion and may be used in various situations. Conclusion: The IMU may become a gold standard for measuring the cervical range of motion. The IMU measured not only the cervical range of motion but also the coupling motion. Furthermore, IMU may be used in various situations. Therefore, IMU must be considered a valuable measurement device.

A Study on the Reliability and Validity of Measuring the Range of Motion of the Elbow Joint Using a Smartphone Application

  • Lee, Jun Cheol
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제10권3호
    • /
    • pp.65-72
    • /
    • 2018
  • The purpose of this study was to assess the intra-tester and inter-tester reliability and validity of elbow flexion range of motion using a smart phone used by the general public. Thirty-one general people participated in this study. The range of motion in active elbow flexion was measured with a goniometer and smart phone over two times by two observers. The intra-taster and inter-tester reliability were evaluated using the intraclass correlation coefficient(ICC). The validity was measured by Pearson's correlation coefficient. The intra-observer reliability was good in all measured items ICC>0.900. The inter-observer reliability was high with ICC>0.806. All correlation coefficients of android app and goniometer were greater than 0.868 and showed a significant positive correlation (p<0.01). The range of motion measurement with a smart phone showed acceptable reliability. Therefore, using a smartphone to measure the range of motion of the elbow joint could provide convenience and economic benefits.

2자유도 동작범위를 고려한 reach volume의 해석적 생성 (Analytic Generation of Reach Volume Based on Range of Two Degrees of Freedom Motion)

  • 기도형
    • 대한산업공학회지
    • /
    • 제23권1호
    • /
    • pp.147-162
    • /
    • 1997
  • When designing workplaces or arranging controls on panel, devices and controls should be placed within the reach of operator's arm or foot to guarantee effective performances. Most of the existing research on the reach volume were based on measurements of a few subject's arm reach, and limited to Caucasian and Chinese populations. Furthermore, reach volume considering foot or trunk motion have not been investigated. Range of human joint motion and that of two degrees of freedom motion are needed to generate reach volume analytically using the sweeping algorithm. However, range of two degrees of freedom motion has not been measured up to now. Therefore, range of two degrees of freedom motion was measured in this research, where 47 college students were participated voluntarily as subjects. The results showed that the motion of one joint can be limited by the motion of another motion, that is to say, the shoulder flexion was decreased significantly when the shoulder was adducted or abducted. Second, new approximate algorithms generating reach volumes were suggested, in which range of two degrees of freedom motion was used as input data. Depending upon the body segment included such as trunk, arm and leg, three types of reach volume were provided, in which the human body was modeled as a multilink system based on the robot kinematics and the sweeping method was employed. Reach volume generated analytically in this study showed statistically reasonable results when compared with that obtained from direct measurement.

  • PDF

시·공간적 주변 블록들의 움직임을 이용하여 적응적으로 탐색 범위 조절을 하는 고속 움직임 추정 (Fast Motion Estimation with Adaptive Search Range Adjustment using Motion Activities of Temporal and Spatial Neighbor Blocks)

  • 이상학
    • 한국전자통신학회논문지
    • /
    • 제5권4호
    • /
    • pp.372-378
    • /
    • 2010
  • 시 공간적으로 인접한 주변 블록들의 움직임 정보들을 이용하여 적응적으로 탐색 범위를 조절하는 고속 움직임 추정 기법을 제안한다. 기존의 탐색 범위 조절을 통한 고속 움직임 추정 기법들은 참조 프레임에 있는 모든 블록들의 움직임 벡터들 중에서 최댓값을 이용하여 현재 블록의 탐색 범위 조절을 하기 때문에 움직임이 작은 블록들에 대해서는 최적의 탐색 범위 조절을 못할 수 있다. 본 논문에서는 참조 프레임과 현재 프레임에서 현재 블록과 인접한 주변 블록들의 움직임 정보를 동시에 고려하여 최적의 탐색 범위를 결정하여 움직임 추정을 고속으로 할 수 있는 움직임 추정 기법을 제안한다. 시간적으로 인접된 블록들 즉 참조 프레임에 있는 주변 블록들의 움직임 정보를 이용하면 움직임이 작은 블록의 탐색 범위의 크기를 적절하게 작게 할 수 있어 고속의 움직임 추정을 할 수 있다. 실험을 통하여 본 논문에서 제안한 시 공간적 주변 블록들의 움직임 정보를 이용하는 탐색 범위 조절을 통한 고속 움직임 추정 기법이 비트율과 움직임 추정 오차는 거의 비슷하게 유지하면서 기존의 방법인 Simple Dynamic Search Range(SDSR) 기법보다 탐색 점의 수를 약 15% 더 감소시킬 수 있음을 확인하였다.

소방용 방화복 및 방화 장비에 따른 상반신 관절 각도의 동작 범위 연구 (Impact of Firefighters' Protective Clothing and Equipment on Upper Body Range of Motion)

  • 김선영;박희주
    • 한국의류산업학회지
    • /
    • 제17권4호
    • /
    • pp.635-645
    • /
    • 2015
  • This study analyzed the range of motion of upper body in different configurations of firefighters' protective clothing and equipment. The purpose of this study was to understand the influence of firefighters' protective clothing and equipment over upper body motion in order to improve design of firefighters' protective clothing and equipment. 12 firefighters' upper body range of motion was analyzed while performing standing and walking trials in five different garment configurations including turnout ensemble, fire boots and the self-contained breathing apparatus. Analysis of upper body range of motion included spinal joints of L5S1, L4L3, T1C7, and C1Head. During standing trials, garment configurations caused a significant difference in range of motions at joints of L5S1, L4L3, T1C7, and C1Head. Analysis on the mean of range of motions at L5S1 and L4L3, showed that firefighters' waist bent forward significantly to a greater extent while they wore a self-contained breathing apparatus. A significantly increased range of motion was found for T1C7 and C1Head while carrying a self-contained breathing apparatus, which indicated an increase in the extension of the trunk and neck backward to stand upright and look squarely. A significant difference in range of motion was also found for L5S1 and L4L3 during walking trials.

Gliding-Mobilization이 견관절유착성관절낭염 환자의 관절가동범위에 미치는 영향 (The Effects on the range of motion of joint with Gliding-Mobilization of the patients of adhesive capsulitis of the shoulder)

  • 정병옥;마상렬;김근조;안병헌
    • 대한물리치료과학회지
    • /
    • 제13권4호
    • /
    • pp.27-34
    • /
    • 2006
  • Purpose : The purpose of this study is to prove the increasing range of motion of joint to the patients of adhesive capsulitis of the shoulder applied the gliding-mobilization. Subjects and methods : The subjects are patients of adhesive capsulitis of the shoulder who have limited range of motion due to capsular pattern on the shoulder. The subjects are volunteer patients without a history of neuromuscular problems and randomly distributed into two groups. 15 experimental subjects(4 male, 11 female) received therapy with gliding-mobilization applied on limited shoulder joint and a second group with 15 control subjects(6 male 9 female) was treated by physiological passive range of motion therapy. The data were analyzed with paired t-test to determine striking differences depending on the course of treatment. Result : 1) In the group treated by gliding-mobilization the range of motion in shoulder flexion was increased in accordance to the course of treatment, and paired t-test showed striking differences(p<.05). 2) The range of motion in shoulder extension was increased in accordance to the course of treatment, and paired t-test showed striking differences(p<0.05). 3) The range of motion in shoulder abduction was increased with serise of treatment, and paired t-test showed striking differences(p<0.05). Conclusion : The gliding-mobilization increases the range of motion of the patient of adhesive capsulitis of the shoulder.

  • PDF