• Title/Summary/Keyword: Motion Accuracy

Search Result 1,627, Processing Time 0.064 seconds

Experimental study on human arm motions in positioning

  • Shibata, S.;Ohba, K.;Inooka, H.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.212-217
    • /
    • 1993
  • In this paper, characteristics of the motions of a human arm are investigated experimentally. When the conditions of the target point are restricted, human adjusts its trajectory and velocity pattern of the arm to fit the conditions skillfully. The purpose of this work is to examine the characteristics of the trajectory, velocity pattern, and the size of the duration in the following cases. First, we examine the case of point-to-point motion. The results are consistent with the minimum jerk theory. However, individual differences in the length of the duration can be observed in the experiment. Second, we examine the case which requires accuracy of positioning at the target point. It is found that the velocity pattern differs from the bell shaped pattern explained by the minimum jerk theory, and has its peak in the first half of the duration. When higher accuracy of the positioning is required, learning effects can be observed. Finally, to examine the case which requires constraint of the arm posture at the target point, we conduct experiments of a human trying to grasp a cup. It is considered that this motion consists of two steps : one is the positioning motion of the person in order to start the grasping motion, the other is the grasping motion of the human's hand approaching toward the cup and grasping it. In addition, two representative velocity patterns are observed : one is the similar velocity pattern explained in the above experiment, the other is the velocity pattern which has its relative maximum in the latter half of the duration.

  • PDF

Scaled and unscaled ground motion sets for uni-directional and bi-directional dynamic analysis

  • Kayhan, Ali Haydar
    • Earthquakes and Structures
    • /
    • v.10 no.3
    • /
    • pp.563-588
    • /
    • 2016
  • In this study, solution models are proposed to obtain code-compatible ground motion record sets which can be used for both uni-directional and bi-directional dynamic analyses. Besides scaled, unscaled ground motion record sets are obtained to show the utility and efficiency of the solution models. For scaled ground motion sets the proposed model is based on hybrid HS-Solver which integrates heuristic harmony search (HS) algorithm with the spreadsheet Solver add-in. For unscaled ground motion sets HS based solution model is proposed. Design spectra defined in Eurocode-8 for different soil types are selected as target spectra. The European Strong Motion Database is used to get ground motion record sets. Also, a sensitivity analysis is conducted to evaluate the effect of different HS solution parameters on the solution accuracy. Results show that the proposed solution models can be regarded as efficient ways to develop scaled and unscaled ground motion sets compatible with code-based design spectra.

Stereo Visual Odometry without Relying on RANSAC for the Measurement of Vehicle Motion (차량의 모션계측을 위한 RANSAC 의존 없는 스테레오 영상 거리계)

  • Song, Gwang-Yul;Lee, Joon-Woong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.4
    • /
    • pp.321-329
    • /
    • 2015
  • This paper addresses a new algorithm for a stereo visual odometry to measure the ego-motion of a vehicle. The new algorithm introduces an inlier grouping method based on Delaunay triangulation and vanishing point computation. Most visual odometry algorithms rely on RANSAC in choosing inliers. Those algorithms fluctuate largely in processing time between images and have different accuracy depending on the iteration number and the level of outliers. On the other hand, the new approach reduces the fluctuation in the processing time while providing accuracy corresponding to the RANSAC-based approaches.

A Study on Performance of Linear Motor for Machine Tools (공작기계용 리니어모터의 운동성능 평가에 관한 연구)

  • 최헌종;강은구;정일용;이석우
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.215-220
    • /
    • 2002
  • Recently, linear motor has been developed for linear motion of machine tools. Linear motor is useful to design the linear motion, high speed and high accuracy, because of the simple system not required the additional mechanical part such as coupling and ballscrew. This paper tested performance of linear motor relevant to motioning and positioning table such as F.R.F., step response and positional accuracy Linear motion system using linear motor requires the effective cooling system because it cause to decrease the positional error and to protect the motor coil. Therefore the positional error measurement was made to evaluate the effect of the temperature variation.

  • PDF

New Imaging Techniques in Myocardial Perfusion SPECT (심근 관류 SOECT의 새로운 방법)

  • Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.1-9
    • /
    • 1998
  • Gated myocardial SPECT and attenuation correction gave birth to new insights into the pathophysiology of ischemic myocardial perfusion and function in clinical routine practice. Gated myocardial Tc-99m-compound SPECT improved diagnostic accuracy of coronary artery disease and enabled us to observe motion and thickening of myocardial walls as well as myocardial perfusion at the same time. Quantitative and qualitative assessment of myocardial performance and perfusion let us to understand the myocardial physiology in ischemia and infarction. In every patient who underwent gated perfusion SPECT, we will find ejection fraction, left ventricular volumes and regional wall motion. There are hopes to use gated TI-201 SPECT for the same purpose and to use gated SPECT for evaluation of wall motion and thickening at stress or immediate post-stress. Attenuation correction could improve diagnostic accuracy mainly by increasing normalcy ratio or performance of non-expert physicians. Both gated methods and attenuation correction improved specificity of non-expert physicians in diagnosing patients with moderate pretest likelihood. New imaging techniques will fill the desire of cardiologists to examine function and perfusion, and possibly metabolism in their clinical routine practice.

  • PDF

Geometric error compensation of machine tools by geometry redesign (형상 재 설계에 의한 공작기계 기하오차 보정)

  • 서성교
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.367-372
    • /
    • 2000
  • Accuracy of a machined component is determined by the relative motion between the cutting tool and the workpiece. One of the important factors which affects the accuracy of this relative motion is the geometric error of machine tools. In this study, geometric error is modeled using form shaping motion of machine tool, where a form shaping function is derived from the homogeneous transformation matrix. Geometric errors are measured by laser interferometer. After that, the local positioning error can be estimated from the form shaping model and geometric error data base. From this information, we can remodel the part by shifting the design surface to the amount of positional error. By generating tool path to the redesigned surface, we can reduce the machining error.

  • PDF

Effects on the Rotational Error Motion of Air Bearing Spindle in High Speed Milling (공기베어링주축의 고속밀링에서 최전오차의 영향)

  • 안선일
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.227-230
    • /
    • 1999
  • In this paper, the machining characteristics of high speed ball end milling affected by the rotational error of high speed spindle using air bearing are investigated. The error motions of a spindle have generally influenced on the surface roughness, the form accuracy, the tool life, etc. in end milling. Experiments are carried out over a wide range of rotational speeds(10,000-50,000rpm). The rotational errors of the spindle are measured by the gap sensor mounted on the spindle shaft at various cutting speeds. The relations between the surface roughness and the spindle error motion are presented. Results show that the rotational accuracy of the spindle directly affects the surface roughness of the machined surface.

  • PDF

Study on the Time Increments in the Houblot Direct Integration Method (Houbolt 직접적분법의 시간증분에 관한 연구)

  • Son, Ju-Ri;Sin, Jung-Ho
    • 한국기계연구소 소보
    • /
    • s.18
    • /
    • pp.55-66
    • /
    • 1988
  • Many direct integration methods are used for numerical analyses of dynamic motion. In these methods, the governing equations of a dynamic system are integrated successively using a step-by-step numerical integration procedure. Time derivatives in the equations are generally approximated using difference formulas involving one or more increments of the time. Time increment has closely relationship with the accuracy of the motion analysis. In this paper, a 4th order Houbolt direct integration method is derived. For a spring-mass system, the motion of the system are analyzed from the 3rd order Houbolt and the 4th order Houbolt approaches respectively. Finally the paper proposes the optimal time-increment based on the accuracy of numerical analyses.

  • PDF

Drilling Characteristics Using the Helical Motion of Ball End Mill Tools (볼엔드밀 공구의 헬리컬 운동을 이용한 구멍가공 특성)

  • 김근오;박규열
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.6
    • /
    • pp.40-47
    • /
    • 1998
  • Drilling is an indispensable process in manufacturing of the die and mould and the other mechanical parts which needs high dimensional and surface accuracy. In this paper, a new type of drilling method was proposed in order to improve both processing efficiency and accuracy. Specifically, the helical motion using ball end mill tools, instead of normal drilling method, was applied to perform an effective hole machining. In this paper, an theoretical background of the new type of drilling method was established, and the feasibility of the proposed theory was proved by experiments, where proposed drilling process in the paper gave a different machining specification than general method did.

  • PDF

Development and Evaluation of 1 Layer Polar Motion Control System for Solar Tracker (태양광 추적장치용 1층 구조의 극좌표 운동기구 개발 및 평가)

  • Kim, Sun Ho;Kim, Byung Cheol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.1
    • /
    • pp.67-73
    • /
    • 2010
  • Finding sufficient supplies of clean energy for future is one of the society's most important challenges according to technologies. Alternative renewable energy source such as sun energy can be substituted for exceeding human energy need. The main factor affect to solar performance is a collective intensity. To enhance intensity, suitable equipment is a solar tracker. This paper presents design and evaluation of 1 layer polar motion control system for solar tracker suitable for building integrated system. To evaluation of tracking accuracy and adaptability, solar tracker with 64 links is implemented. In experimental results, the accuracy of tracking has under ${\pm}0.0287^{\circ}$ and the thickness has under 140mm.